Determination of the Optimal Structure of Repowering a Metallurgical CHP Plant Fired with Technological Fuel Gases
Dobór optymalnej struktury elektrociepłowni gazowo-parowej opalanej hutniczymi gazami palnymi
Autorzy:
Ziębik, A.
Warzyc, M.
Gładysz, P.
Powiązania:
https://bibliotekanauki.pl/articles/352232.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
combined gas-and-steam cycle
metallurgical CHP plant
structure optimization
probabilistic approach
elektrociepłownia hutnicza
układ gazowo-parowy
optymalizacja struktury
podejście probabilistyczne
Opis:
CHP plants in ironworks are traditionally fired with low-calorific technological fuel gases and hard coal. Among metallurgical fuel gases blast-furnace gas (BFG) dominates. Minor shares of gaseous fuels are converter gas (LDG) and surpluses of coke-oven gas (COG). Metallurgical CHP plant repowering consists in adding a gas turbine to the existing traditional steam CHP plant. It has been assumed that the existing steam turbine and parts of double-fuel steam boilers can be used in modernized CHP plants. Such a system can be applied parallelly with the existing steam cycle, increasing the efficiency of utilizing the metallurgical fuel gases. The paper presents a method and the final results of analyzing the repowering of an existing metallurgical CHP plant fired with low-calorific technological fuel gases mixed with hard coal. The introduction of a gas turbine cycle results in a better effectiveness of the utilization of metallurgical fuel gases. Due to the probabilistic character of the input data (e.g. the duration curve of availability of the chemical energy of blast-furnace gas for CHP plant, the duration curve of ambient temperature) the Monte Carlo method has been applied in order to choose the optimal structure of the gas-and-steam combined cycle CHP unit, using the Gate Cycle software. In order to simplify the optimizing calculation, the described analysis has also been performed basing on the average value of availability of the chemical energy of blast-furnace gas. The fundamental values of optimization differ only slightly from the results of the probabilistic model. The results obtained by means of probabilistic and average input data have been compared using new information and a model applying average input data. The new software Thermoflex has been used. The comparison confirmed that in the choice of the power rating of the gas turbine based on both computer programs the results are similar.
Tradycyjnie elektrociepłownie hutnicze są opalane niskokalorycznymi palnymi gazami technologicznymi w mieszaninie z pyłem węgla kamiennego. W mieszaninie gazów dominujący jest udział gazu wielkopiecowego. Znacznie mniejsze są udziały gazu koksowniczego i konwertorowego. Modernizacja elektrociepłowni hutniczej (tzw. repowering) polega na dobudowaniu do istniejącej struktury członu gazowego. W analizie założono możliwość wykorzystania istniejących turbin parowych oraz części dwupaliwowych kotłów parowych. Układ gazowo-parowy zostanie połączony równolegle z istniejącym obiegiem parowym, zwiększając tym samym efektywność energetyczną wykorzystania niskokalorycznych gazów hutniczych. W artykule zaprezentowano metodologię oraz wyniki końcowe przeprowadzonej analizy modernizacji istniejącej elektro- ciepłowni hutniczej opalanej niskokalorycznymi gazami hutniczymi w mieszance z pyłem węgla kamiennego. Bazowano przy tym na zbiorze danych wejściowych z lat 1996-2000. Z uwagi na probabilistyczny charakter danych wejściowych (min. wykres uporządkowany dostępności energii chemicznej gazu wielkopiecowego oraz wykres uporządkowany temperatury zewnętrznej) wykorzystano metodę Monte Carlo w celu doboru optymalnej struktury kombinowanego gazowo-parowego układu elektrocie- płowni wykorzystując do tego oprogramowanie Gate Cycle. Obliczenia optymalizacyjne zostały również przeprowadzone w oparciu o uśrednioną wartość strumienia energii chemicznej gazu wielkopiecowego dostępnego dla elektrociepłowni. Wyniki obliczeń podstawowych parametrów z tej analizy różnią się w nieznacznym stopniu od wyników uzyskanych za pomocą modelu probabilistycznego. Wyniki uzyskane zarówno z metody probabilistycznej, jak i bazującej na wartościach średnich danych wejściowych zostały porównane z rezultatami obliczeń w oparciu o nowy zestaw danych (lata 2005-2008), jak również nowy model utworzony w programie Thermotlex oraz Engineering Equation Solver. Obliczenia zostały przeprowadzone w oparciu o uśredniony strumień energii chemicznej gazu wielkopiecowego dostępnego dla elektrociepłowni. Zastosowane do doboru struktury modernizowanej elektrociepłowni hutniczej programy komputerowe Gate Cycle i Thermoflex dały zbliżone rezultaty.
Źródło:
Archives of Metallurgy and Materials; 2014, 59, 1; 105-116
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance analysis of a new combined organic Rankine cycle and vapor compression cycle for power and refrigeration cogeneration
Autorzy:
Toujani, N.
Bouaziz, N.
Chrigui, M.
Kairouani, L.
Powiązania:
https://bibliotekanauki.pl/articles/175539.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
organic Rankine cycle
cogeneration
vapor compression cycle
new combined
Opis:
Organic Rankine cycle (ORC) is considered the most used technology in low temperature heat recovery units for cogeneration (electricity and cold). In this study, the effect of the operating parameters, in particular the condensation and the vaporization temperatures on the performance of the cycle are analyzed. In addition, we developed a new combination of organic Rankine cycle and vapor compresion cycle systems to make cogeneration with a negative cold (-10–0◦C), as well with a positive cold (0–10◦C). Three configurations are examined and studied in terms of energy efficiency, namely the performance of each configuration including net power, refrigeration capacity and overall efficiency, the thermal efficiency for ORC and the coefficient of performance for VCC. The used working fluids are n-hexane for the ORC and R600 for the VCC. We also try to apply this new system to have the cogeneration with congelation temperatures. The results show that, for cogeneration with negative cold, among the three configurations that we have developed, the cycle with recovery is preferable in which it has a better energy performance. For a hot spring of 1000 kW, this cycle can provide simultaneously, a maximum net work of 17 kW and a maximum net cooling capacity of 160 kW and an overall coefficient of the order of 0.3. For the production of positive cold, among the three configurations that we have developed, the basic cycle (without recovery) is the most suitable. With the same source of heat a maximum net work of 65 kW and a net cooling capacity in the order of 1000 kW with a global coefficient in the order of 1.05 is obtained. Our system is not only limited to be exploited for a temperature range between -10 ◦C and 10 ◦C, but can also be used with other fluids for lower temperatures (congelation temperatures).
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2018, 140; 39-81
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analysis of thermodynamic cycles of selected nuclear ship power plants with hightemperature helium- cooled nuclear reactor
Autorzy:
Szewczuk-Krypa, N.
Grzymkowska, A.
Głuch, J.
Powiązania:
https://bibliotekanauki.pl/articles/260189.pdf
Data publikacji:
2018
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
nuclear ship power plant
nuclear reactor
HTGR
gas turbine
steam turbine
combined cycle
Opis:
This paper presents a comparative analysis of thermodynamic cycles of two ship power plant systems with a hightemperature helium- cooled nuclear reactor. The first of them is a gas system with recuperator , in which classical gas chamber is substituted for a HTGR reactor (High Temperature Gas-cooled Reactor) . The second of the considered cycles is a combined gas-steam system where working medium flux from gas turbine outlet is directed into waste heat boiler and its heat is utilized for production of superheated steam to drive steam turbine. Preliminary calculations of the combine cycles showed that it is necessary to expand the system by adding to its steam part an inter-stage overheat for secondary steam, owing to that a required degree of steam dryness at outlet from the turbine can be reached, ensuring its correct operational conditions. The analyzed power systems were compared to each other with regard to efficiency of their thermodynamic cycles. Also, efficiency of particular cycles were subjected to optimization in respect to such parameters as : working gas temperature at outlet from reactor in gas system as well as steam pressure at outlet from waste heat boiler and partition pressure in steam part of combined system. Advantages of nuclear power plants compared with the classical power systems dominating currently in sea transport were also discussed.
Źródło:
Polish Maritime Research; 2018, S 1; 218-224
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Water management at CCGT unit
Optymalizacja gospodarki wodą w bloku gazowo-parowym
Autorzy:
Szaban, J.
Wawrzyński, I.
Powiązania:
https://bibliotekanauki.pl/articles/276594.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
optymalizacja
Ovation
SmartProcess
chłodnia wentylatorowa
Cykl Kombinowany w Wysokosprawnej Kogeneracji
optimization
power plant
cooling towers
Combined Cycle Gas Turbine
Opis:
This paper discusses a water management optimization of cooling towers. Description of a problem solution as well as its industrial application is included. The used software belongs to Emerson's SmartProcess products. It has been applied to two power plants as a part of the Ovation DCS (distributed control system).
W artykule omówiono optymalizacje gospodarki wodnej w chłodni wentylatorowej. Podano opis rozwiązania problemem jak również jego zastosowania w przemyśle. Zastosowano część oprogramowania z pakietu SmartProcess dostarczanego przez Emerson. Pakiet użyto w dwóch elektrowniach, jako uzupełnienie rozproszonego systemu sterowania Ovation.
Źródło:
Pomiary Automatyka Robotyka; 2013, 17, 2; 250-253
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Exergetic diagnostics of a gas-and-steam power plant
Diagnostyka egzergetyczna elektrowni gazowo-parowej
Autorzy:
Stanek, Wojciech
Simla, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/396720.pdf
Data publikacji:
2019
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
combined cycle power plant
exergetic analysis
mathematical model
elektrownia gazowo-parowa
diagnostyka egzergetyczna
model matematyczny
Opis:
Evaluation of thermodynamic efficiency of a power plant is usually performed using the method of so-called thermal diagnostics, based on energy balancing. Energetic analysis is however suitable only for a quantitative assessment and for comparing similar technologies. In order to properly assess the origins of energy losses in the given system, an exergetic analysis has to be applied. The paper describes the rules of exergetic diagnostics, which greatly extends the potential of classic thermal diagnostics. A calculation example of a combined cycle power plant is included. The example demonstrates the potential of exergetic diagnostics for locating exergy losses and explains the reasons for increased consumption of fuels by comparing two working conditions of the system: reference and operational.
W praktyce do oceny efektywności termodynamicznej działania elektrowni lub elektrociepłowni stosuje się narzędzia tak zwanej diagnostyki cieplnej opartej na bilansowaniu energetycznym. Analiza energetyczna nadaje się jednak wyłącznie do oceny ilościowej oraz porównywania podobnych technologii energetycznych. Dla prawidłowej oceny miejsc i przyczyn powstawania strat w systemach energetycznych konieczne jest zastosowanie analizy egzergetycznej. W artykule zaprezentowano zasady diagnostyki egzergetycznej, znacznie poszerzającej potencjał klasycznej diagnostyki cieplnej wraz z przykładem obliczeniowym dotyczącym elektrowni gazowo-parowej. Diagnostyka egzergetyczna jest techniką z zakresu zaawansowanej analizy egzegetycznej, pozwalającą na szczegółową detekcję przyczyn generowania strat w komponentach z uwzględnieniem tak zwanych przyczyn wewnątrzpochodnych i zewnątrzpochodnych. Procedury diagnostyki egzergetycznej, w połączeniu z technikami modelowania matematycznego, pozwalają na poszerzoną kontrolę eksploatacji procesów i systemów produkcyjnych. Ponadto umożliwiają one dekompozycję kosztu egzergetycznego pomiędzy składowe wynikające z wzajemnych powiązań pomiędzy komponentami systemu. Zaprezentowany przykład obliczeniowy dotyczący elektrowni gazowo-parowej prezentuje potencjał diagnostyki egzergetycznej w zakresie lokalizacji strat egzergii i wyjaśnia przyczyny zwiększonego zużycia zasobów zasilających system poprzez porównanie dwóch stanów: referencyjnego oraz dowolnego stanu eksploatacyjnego systemu.
Źródło:
Civil and Environmental Engineering Reports; 2019, 29, 1; 1-17
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Parametric analysis of the efficiency of the combined gas-steam turbine unit of a hybrid cycle for the FPSO vessel
Autorzy:
Serbin, Serhiy
Washchilenko, Nikolay
Dzida, Marek
Kowalski, Jerzy
Powiązania:
https://bibliotekanauki.pl/articles/2033277.pdf
Data publikacji:
2021
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
combined-cycle
gas turbine
steam turbine
power plant
Opis:
A thermal diagram of the combined gas‒steam turbine unit of a hybrid cycle, which is an energy complex consisting of a base gas turbine engine with a steam turbine heat recovery circuit and a steam-injected gas turbine operating with overexpansion, is proposed. A mathematical model of a power plant has been developed, taking into consideration the features of thermodynamic processes of simple, binary, and steam-injected gas‒steam cycles. Thermodynamic investigations and optimization of the parameters of a combined installation of a hybrid cycle for the generation of electrical energy have been carried out. Three-dimensional calculations of the combustion chamber of a steam-injected gas turbine were carried out, which confirmed the low emissions of the main toxic components.
Źródło:
Polish Maritime Research; 2021, 4; 122-132
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigating the Efficiency of Combined Cycle Power Plants with the Data Envelopment Analysis Process (with an Emphasis on Air Pollution)
Autorzy:
Sanjaranipour, Noushin
Atabi, Farideh
Momeni, Mansour
Ghodousi, Jamal
Lahijanian, Akramolmolok
Powiązania:
https://bibliotekanauki.pl/articles/2055783.pdf
Data publikacji:
2022
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
efficiency
Combined Cycle Power Plants
DEA
air pollution
Opis:
Performance management is one of the most significant strategies in promoting the efficiency of organizations and is highly sensitive. It is important to check the efficiency of combined cycle power plants because of their major contribution to power generation and air pollution. This study was conducted to evaluate the economic and environmental efficiency of Combined Cycle Power Plants (CCPPs). The inputs and outputs required to evaluate the performance of the power plants were determined according to expert opinions. Then, the 7-year statistics and information of the Qom, Neishabour, Shahid Rajaee, Yazd and Kerman power plants were collected as the desired CCPPs in Iran. The Window Data Envelopment Analysis (WDEA) method was used for evaluating the efficiency of the power plants. The 3-year window length showed that most of the power plants were efficient. Only the Rajaee, Neishabour and Yazd power plants were ineffective in some years. The mean efficiency of the power plants in the 4-year window length showed that the plants were efficient from 2008 to 2010.
Źródło:
Geomatics and Environmental Engineering; 2022, 16, 2; 111--125
1898-1135
Pojawia się w:
Geomatics and Environmental Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania wpływu struktury elektrowni gazowo-parowych na charakterystyki sprawności
The Influence of the Structure of a Gas-And-Steam Power Station on the Characteristics of Efficiency
Autorzy:
Kotowicz, J.
Chmielniak, T.
Powiązania:
https://bibliotekanauki.pl/articles/359427.pdf
Data publikacji:
2006
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
turbina gazowa
układy gazowo-parowe
EXPLO-SHIP 2006
gas turbine engine
combined cycle
Opis:
W artykule przedstawiono dwie metodologie określania sprawności elektrowni gazowo-parowych. Dla każdej metodologii przedstawiono przykłady obliczeniowe. Opracowane metodologie pozwalają wyznaczyć sprawność badanych układów w funkcji temperatury na wlocie do turbiny gazowej i stopnia sprężania przy optymalnej części parowej układu. Obliczenia wykonano dla różnych struktur elektrowni: z kotłem jednociśnieniowym, dwuciśnieniowym z przegrzewem i bez przegrzewu międzystopniowego oraz trójciśnieniowym z przegrzewem międzystopniowym.
The paper deals with two methods of determining the efficiency of combined gas-and-steam power stations. For each of them examples of calculations have been quoted. These two methods permit to determine the efficiency of investigated systems as a function of temperature at the inlet to the gas turbine and the compression ratio for the optimal steam part of the system. Calculations have been carried out concerning various structures of power stations with a single-pressure waste-heat boiler, a double-pressure waste-heat boiler with and without reheat and a triple-pressure waste-heat boiler and reheat.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2006, 10 (82); 273-286
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Maximisation of Combined Cycle Power Plant Efficiency
Maksymalizacja sprawności elektrowni gazowo-parowych
Autorzy:
Kotowicz, J.
Job, M.
Brzęczek, M.
Powiązania:
https://bibliotekanauki.pl/articles/397508.pdf
Data publikacji:
2015
Wydawca:
ENERGA
Tematy:
combined cycle power plant
turbine cooling
thermodynamic optimisation
elektrownia gazowo-parowa
chłodzenie turbiny
optymalizacja
Opis:
The paper presents concepts for increasing the efficiency of a modern combined cycle power plant. Improvement of gas turbine performance indicators as well as recovering heat from the air cooling the gas turbine’s flow system enable reaching gross electrical efficiencies of around 65%. Analyses for a wide range of compressor pressure ratios were performed. Operating characteristics were developed for the analysed combined cycle plant, for different types of open air cooling arrangements of the gas turbine’s expander: convective, transpiration and film.
W artykule przedstawiono koncepcje zwiększenia sprawności nowoczesnej elektrowni gazowo-parowej. Poprawa charakterystyk pracy turbiny gazowej oraz wykorzystanie ciepła powietrza chłodzącego układ przepływowy turbiny gazowej pozwalają na osiągnięcie sprawności elektrycznej brutto rzędu 65%. Analizy przeprowadzono w szerokim zakresie stopni sprężania w kompresorze. Sporządzono główne charakterystyki pracy analizowanego układu gazowo-parowego dla różnych typów chłodzenia otwartego powietrzem ekspandera turbiny gazowej: konwekcyjnego, transpiracyjnego oraz błonowego.
Źródło:
Acta Energetica; 2015, 4; 42-53
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The improvement of environmental characteristics of the combined cycle power plant by the implementation of the carbon capture installation
Autorzy:
Kotowicz, J.
Brzęczek, M.
Job, M.
Powiązania:
https://bibliotekanauki.pl/articles/134906.pdf
Data publikacji:
2015
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
combined cycle power plant
post-combustion technology
chemical absorption
carbon capture installation
power plant efficiency
ecological characteristics
Opis:
The paper describes a combined cycle power plant with carbon capture installation in a post-combustion technology. Carbon dioxide is separated from flue gas by using a chemical absorption method with monoethanolamine (MEA) as a sorbent. Separated carbon dioxide is compressed in order to prepare for transportation to the storage place. This paper identifies the electric efficiencies and other characteristic parameters of power plants before and after implementation of CO2 capture installation, as well as the power plant efficiency drop, and the improvement of ecological characteristics related to the implementation of this installation. The implementation of the installation described herein is associated with the efficiency loss caused by the auxiliary power for additional installations. The CO2 separation installation is powered by heat energy required for reclaiming the sorbent. This energy is taken in the form of steam extracted from the steam cycle, thus reducing the steam turbine power output, while the CO2 compression installation is powered by electric energy.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2015, 44 (116); 19-24
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermodynamic analysis of a new conception of supplementary firing in a combined cycle
Autorzy:
Kotowicz, J.
Bartela, Ł.
Balicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/239969.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
analiza termodynamiczna
dodatkowe systemy spalania
układ kombinowany
combined cycle
supplementary firing systems
thermodynamic analysis
Opis:
The paper analyzes a new concept of integration of combined cycle with the installation of supplementary firing. The whole system was enclosed by thermodynamic analysis, which consists of a gas-steam unit with triple-pressure heat recovery steam generator. The system uses a determined model of the gas turbine and the assumptions relating to the construction features of steam-water part were made. The proposed conception involves building of supplementary firing installation only on part of the exhaust stream leaving the gas turbine. In the proposed solution superheater was divided into two sections, one of which was located on the exhaust gases leaving the installation of supplementary firing. The paper presents the results of the analyses of which the main aim was to demonstrate the superiority of the new thermodynamic concept of the supplementary firing over the classical one. For this purpose a model of a system was built, in which it was possible to carry out simulations of the gradual transition from a classically understood supplementary firing to the supplementary firing completely modified. For building of a model the GateCycle[TM] software was used.
Źródło:
Archives of Thermodynamics; 2010, 31, 4; 15-24
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermodynamic and economic analysis of a gas turbine combined cycle plant with oxy-combustion
Autorzy:
Kotowicz, J.
Job, M.
Powiązania:
https://bibliotekanauki.pl/articles/240636.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
gas turbine combined cycle
oxy-combustion
blok gazowo-parowy
oksyspalanie
Opis:
This paper presents a gas turbine combined cycle plant with oxy-combustion and carbon dioxide capture. A gas turbine part of the unit with the operating parameters is presented. The methodology and results of optimization by the means of a genetic algorithm for the steam parts in three variants of the plant are shown. The variants of the plant differ by the heat recovery steam generator (HRSG) construction: the single-pressure HRSG (1P), the double-pressure HRSG with reheating (2PR), and the triple-pressure HRSG with reheating (3PR). For obtained results in all variants an economic evaluation was performed. The break-even prices of electricity were determined and the sensitivity analysis to the most significant economic factors were performed.
Źródło:
Archives of Thermodynamics; 2013, 34, 4; 215-233
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermodynamic analysis of an innovative steam turbine power plant with oxy-methane combustors
Autorzy:
Kindra, Vladimir Olegovich
Osipov, Sergey Konstantinovich
Zlyvko, Olga Vladimirovna
Shcherbatov, Igor Alexandrovich
Sokolov, Vladimir Petrovich
Powiązania:
https://bibliotekanauki.pl/articles/1955067.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Combined cycle power plant
carbon capture
storage system
precombustion capture
post-combustion capture
oxy-fuel combustion
Opis:
The Rankine cycle steam turbine power plants make a base for world electricity production. The efficiency of modern steam turbine units is not higher than 43–45%, which is remarkably lower compared to the combined cycle power plants. However, an increase in steam turbine power plant efficiency could be achieved by the rise of initial cycle parameters up to ultra-supercritical values: 700–780◦C, 30–35 MPa. A prospective steam superheating technology is the oxy-fuel combustion heating in a sidemounted combustor located in the steam pipelines. This paper reviews thermal schemes of steam turbine power plants with one or two side-mounted steam superheaters. An influence of the initial steam parameters on the facility thermal efficiency was identified and primary and secondary superheater parameters were optimized. It was found that the working fluid superheating in the side-mounted oxy-methane combustors leads to an increase of thermal efficiency higher than that with the traditional boiler superheating in the initial temperature ranges of 700–780◦C and 660–780◦C by 0.6% and 1.4%, respectively.
Źródło:
Archives of Thermodynamics; 2021, 42, 4; 123-140
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermodynamic analysis of cycle arrangements of the coal-fired thermal power plants with carbon capture
Autorzy:
Kindra, Vladimir Olegovich
Milukov, Igor Alexandrovich
Shevchenko, Igor Vladimirovich
Shabalova, Sofia Igorevna
Kovalev, Dmitriy Sergeevich
Powiązania:
https://bibliotekanauki.pl/articles/1955057.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
combined cycle power plant
carbon capture
storage system
precombustion capture
post-combustion capture
oxy-fuel combustion
Opis:
The electricity production by combustion of organic fuels, especially coal, increases the atmospheric CO2 content, which contributes to global warming. The greenhouse gas emissions by the power production industry may be reduced by the application of CO2 capture and storage systems, but it remarkably decreases the thermal power plant (TPP) efficiency because of the considerable increase of the auxiliary electricity requirements. This paper describes the thermodynamic analysis of a combined cycle TPP with coal gasification and preliminary carbon dioxide capture from the syngas. Utilization of the heat produced in the fuel preparation increases the TPP net efficiency from 42.3% to 47.2%. Moreover, the analysis included the combined cycle power plant with coal gasification and the CO2 capture from the heat recovery steam generator exhaust gas, and the oxy-fuel combustion power cycle with coal gasification. The coal-fired combined cycle power plant efficiency with the preliminary CO2 capture from syngas is 0.6% higher than that of the CO2 capture after combustion and 9.9% higher than that with the oxy-fuel combustion and further CO2 capture. The specific CO2 emissions are equal to 103 g/kWh for the case of CO2 capture from syngas, 90 g/kWh for the case of CO2 capture from the exhaust gas and 9 g/kWh for the case of oxy-fuel combustion.
Źródło:
Archives of Thermodynamics; 2021, 42, 4; 103-121
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of parallel hot windbox repowering on 387 MW fossil fuel power plant
Autorzy:
Harutyunyan, A.
Badyda, K.
Wołowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/175190.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
combined cycle power plant
fossil boiler
hot windbox repowering
CO2 emissions
Opis:
The paper presents the concept of repowering in existing power plant. Among technologies for existing steam power plants, the hot windbox repowering is the fastest way to respond to the energy demand, improve efficiency and reduce the pollutants emissions. Thermodynamic analysis of power plant model with fossil boiler before and after hot windbox repowering, has been investigated using commercial software. The purpose of this work is to understand and analyze the effect of hot windbox repowering on 387 MW fossil fuel power plant as well as the effect of additional heat exchangers, which have been installed parallel with regeneration system to use the heat of boiler exhaust gases. In this way, after repowering the summary power of power plant in base load is 615 MW, which has been reached adding gas turbine (176.9 MW). To analyze the model, calculations were performed in 3 stages: 1) calculation and comparison of the thermodynamic parameters as well as carbon dioxide emissions of power plant model before and after repowering, 2) analysis of the optimal value of feed water mass flow through heat exchangers installed after economizer, 3) calculation of thermodynamic parameters in values 100%, 90%, 80% and 75% of fossil boiler heat loads.
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2016, 131; 79-95
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies