Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "coefficient performance" wg kryterium: Temat


Tytuł:
System of heat supply ’ad hoc’ with solar wall
Autorzy:
Shapoval, S.
Zhelykh, V.
Kapalo, P.
Venhryn, I.
Dacko, O.
Powiązania:
https://bibliotekanauki.pl/articles/104281.pdf
Data publikacji:
2018
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
solar wall
temperature
specific heat capacity
coefficient of performance system
Opis:
For the implementation of solar thermal installations it is necessary to optimize energy-efficient external enclosures due to the correct installation and design of these units at different orientations of external walls. Investigated the effectiveness of using solar energy in the conditions of shortage of energy in Ukraine. Ad hoc solar wall look at two modes of its operation. Given a variety of graphical, analytical expressions for understanding the operation of the proposed design. Given these changes of the heat carrier temperature solar wall income the amount of the specific instantaneous heat output through time. The article considers the possibility of using experimental models, solar wall under the influence of her unfavourable ad hoc factors. It is established that the proposed model is solar wall is quite effective and can be used in solar heating systems.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2018, 65, 4; 49-56
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A study of a heat pump ground collector
Badania wymiennika gruntowego pompy ciepła
Autorzy:
Szreder, M.
Powiązania:
https://bibliotekanauki.pl/articles/792689.pdf
Data publikacji:
2014
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
ground source heat pump
vertical collector
spiral compressor
heat source
coefficient performance
heating system
power consumption
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2014, 14, 3
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigations into the influence of functional parameters of a heat pump on its thermal efficiency
Badanie wpływu parametrów funkcjonalnych pompy ciepła na wydajność cieplną
Autorzy:
Szreder, M.
Powiązania:
https://bibliotekanauki.pl/articles/792384.pdf
Data publikacji:
2013
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
heat pump
functional parameter
vertical collector
thermal efficiency
scroll type compressor
evaporator
condenser
heat source
coefficient performance
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2013, 13, 1
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy efficiency of ground heat exchangers co-operating with a compressor heat pump
Efektywnosc energetyczna wymiennikow gruntowych wspolpracujacych ze sprezarkowa pompa ciepla
Autorzy:
Kurpaska, S.
Latala, H.
Powiązania:
https://bibliotekanauki.pl/articles/793577.pdf
Data publikacji:
2012
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
heat pump
compressor heat pump
heat exchanger
horizontal exchanger
vertical exchanger
coefficient performance
statistical analysis
variance analysis
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2012, 12, 1
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy efficiency of ground heat exchangers co-operating with a compressor heat pump
Efektywnosc energetyczna wymiennikow gruntowych wspolpracujacych ze sprezarkowa pompa ciepla
Autorzy:
Kurpaska, S.
Latala, H.
Powiązania:
https://bibliotekanauki.pl/articles/792483.pdf
Data publikacji:
2012
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
compressor heat pump
heat exchanger
horizontal exchanger
vertical exchanger
ground heat exchanger
coefficient performance
statistical analysis
energy efficiency
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2012, 12, 2
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Method of determining the COP coefficient for a cooling system
Sposób wyznaczenie współczynnika COP dla układu chłodniczego
Autorzy:
Rząsa, Mariusz
Pochwała, Sławomir
Szymaniec, Sławomir
Powiązania:
https://bibliotekanauki.pl/articles/1841357.pdf
Data publikacji:
2020
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
coefficient of performance
cooling system
inverter compressor
współczynnik COP
układ chłodniczy
sprężarka inwertorowa
Opis:
The basic metrological problem analyzed in this article is the experimental determination of the COP coefficient for arefrigerating system working in a stationary cooling chamber. This issue is because manufacturers of chillers provide the value of this coefficient in device technicaldata.In practice, after installing the refrigeration unit, the COP is often lower. The paper presents amethod of balancing cooling energy for a complete refrigeration system.
Podstawowym problemem metrologicznym, który autorzy pragną przedstawić jest eksperymentalne wyznaczenie współczynnika COP dla układu chłodniczego, pracującego w stacjonarnej komorze chłodniczej. Zagadnienie to jest istotne, ponieważ producenci agregatów chłodniczych najczęściej podają współczynnik COP dla agregatu chłodniczego. W praktyce po zamontowaniu agregatu chłodniczego w komorze chłodniczej współczynnik COP jest niejednokrotnie niższy. Trudność z wyznaczeniem współczynnika COP w układzie chłodniczym polega na koniczności zbilansowania mocy chłodniczej dla całego układu wraz z komorą chłodniczą. W pracy przedstawiono sposób bilansowania energii chłodniczej dla kompletnego układu chłodniczego oraz opisano budowę stanowiska do wyznaczania współczynnika COP.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2020, 10, 4; 69-72
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance analysis of multipurpose refrigeration system (MRS) on fishing vessel
Autorzy:
Ust, Y.
Karakurt, A.
Gunes, U.
Powiązania:
https://bibliotekanauki.pl/articles/258796.pdf
Data publikacji:
2016
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
refrigeration cycles
exergy analysis
exergetic performance coefficient
COP
exergy efficiency
Opis:
The use of efficient refrigerator/freezers helps considerably to reduce the amount of the emitted greenhouse gas. A two-circuit refrigerator-freezer cycle (RF) reveals a higher energy saving potential than a conventional cycle with a single loop of serial evaporators, owing to pressure drop in each evaporator during refrigeration operation and low compression ratio. Therefore, several industrial applications and fish storage systems have been utilized by using multipurpose refrigeration cycle. That is why a theoretical performance analysis based on the exergetic performance coefficient, coefficient of performance (COP), exergy efficiency and exergy destruction ratio criteria, has been carried out for a multipurpose refrigeration system by using different refrigerants in serial and parallel operation conditions. The exergetic performance coefficient criterion is defined as the ratio of exergy output to the total exergy destruction rate (or loss rate of availability). According to the results of the study, the refrigerant R32 shows the best performance in terms of exergetic performance coefficient, COP, exergy efficiency, and exergy destruction ratio from among the other refrigerants (R1234yf, R1234ze, R404A, R407C, R410A, R143A and R502). The effects of the condenser, freezerevaporator and refrigerator-evaporator temperatures on the exergetic performance coefficient, COP, exergy efficiency and exergy destruction ratios have been fully analyzed for the refrigerant R32.
Źródło:
Polish Maritime Research; 2016, 2; 48-56
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessing the Solar Power Plant Efficiency Degradation Resulting from Heating
Autorzy:
Lavrik, A.
Yakovleva, E.
Lеskov, A.
Powiązania:
https://bibliotekanauki.pl/articles/124651.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
photoelectric module
PEM
solar power plant
performance coefficient
heating
cooling
Opis:
Renewable power sources (RPS) play an ever growing role in power production. With the green power cost decreasing, the RPS share (including hydro power plants) in power production grows fast. Using RPS in supplying power to various facilities reduces the CO2 emission into atmosphere, thus reducing the greenhouse effect and being a fundamental factor in fighting the global warming. Every type of RPS possesses certain drawbacks that need to be eliminated. RPS units do have disadvantages, too, including low efficiency coefficient, and low specific power. However, there is the need for specific technological conditions. The present work describes the issue of photoelectric module heating. Photoelectric module heating results in both lower output voltage and module aging acceleration. The present work offers the method for assessing the practicability of development and implementation of solar power cell module active cooling systems, based on the photoelectric module daily performance schedules, drawing on statistic meteorological data collected over many years, and also it presents the brief description of various methods for cooling photoelectric modules.
Źródło:
Journal of Ecological Engineering; 2018, 19, 3; 115-119
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Method of determining the COP coefficient for a cooling system
Sposób wyznaczenie współczynnika COP dla układu chłodniczego
Autorzy:
Rząsa, Mariusz
Pochwała, Sławomir
Szymaniec, Sławomir
Powiązania:
https://bibliotekanauki.pl/articles/1841374.pdf
Data publikacji:
2020
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
coefficient of performance
cooling system
inverter compressor
współczynnik COP
układ chłodniczy
sprężarka inwertorowa
Opis:
The basic metrological problem analyzed in this article is the experimental determination of the COP coefficient for arefrigerating system working in a stationary cooling chamber. This issue is because manufacturers of chillers provide the value of this coefficient in device technicaldata.In practice, after installing the refrigeration unit, the COP is often lower. The paper presents amethod of balancing cooling energy for a complete refrigeration system.
Podstawowym problemem metrologicznym, który autorzy pragną przedstawić jest eksperymentalne wyznaczenie współczynnika COP dla układu chłodniczego, pracującego w stacjonarnej komorze chłodniczej. Zagadnienie to jest istotne, ponieważ producenci agregatów chłodniczych najczęściej podają współczynnik COP dla agregatu chłodniczego. W praktyce po zamontowaniu agregatu chłodniczego w komorze chłodniczej współczynnik COP jest niejednokrotnie niższy. Trudność z wyznaczeniem współczynnika COP w układzie chłodniczym polega na koniczności zbilansowania mocy chłodniczej dla całego układu wraz z komorą chłodniczą. W pracy przedstawiono sposób bilansowania energii chłodniczej dla kompletnego układu chłodniczego oraz opisano budowę stanowiska do wyznaczania współczynnika COP.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2020, 10, 4; 69-72
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficiency of the heat pump cooperating with various heat sources in monovalent and bivalent systems
Efektywnosc pompy ciepla wspolpracujacej z dolnymi zrodlami ciepla w systemie mono i biwalentnym
Autorzy:
Kurpaska, S.
Latala, H.
Lapczynska-Kordon, B.
Mudryk, K.
Powiązania:
https://bibliotekanauki.pl/articles/792536.pdf
Data publikacji:
2012
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
heat pump
heat source
heat distribution
monovalent system
bivalent system
compressor heat pump
vertical exchanger
horizontal exchanger
coefficient performance
heating system
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2012, 12, 1
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Review of mechanical vapour compression refrigeration system part 2: performance challenge
Autorzy:
Mahmood, R. A.
Ali, O. M.
Al-Janabi, A.
Al-Doori, G.
Noor, M. M.
Powiązania:
https://bibliotekanauki.pl/articles/2106451.pdf
Data publikacji:
2021
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
para
układ chłodniczy
współczynnik wydajności
vapour compression
refrigeration system
cycle
coefficient of performance COP
Opis:
Reducing energy consumption and providing high performance for a vapour compression refrigeration system are big challenges that need more attention and investigation. This paper provides an extensive review of experimental and theoretical studies to present the vapour compression refrigeration system and its modifications that can be used to improve system’s performance and reduce its energy consumption. This paper also presents the challenges that can be considered as a gab of research for the future works and investigations. Cooling capacity, refrigerant effect, energy consumption can be improved by using vapour injection technique, natural working fluid, and heat exchanger. Based on the outcome of this paper, vapour injection technique using natural refrigerant such as water can provide ultimate friendly refrigeration system. Future vision for the vapour compression refrigeration system and its new design technique using Computational Fluid Dynamic (CFD) is also considered and presented.
Źródło:
International Journal of Applied Mechanics and Engineering; 2021, 26, 3; 119--130
1734-4492
2353-9003
Pojawia się w:
International Journal of Applied Mechanics and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Portable heat pump testing device
Autorzy:
Kłosowiak, R.
Bartoszewicz, J.
Urbaniak, R.
Powiązania:
https://bibliotekanauki.pl/articles/265008.pdf
Data publikacji:
2015
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
heat pump
renewable energy
coefficient of performance (COP)
pompa ciepła
energia odnawialna
współczynnik wydajności
Opis:
The aim of this paper is to present the design and working principle of a portable testing device for heat pumps in the energy recirculation system. The presented test stand can be used for any refrigerating/reverse flow cycle device to calculate the device energy balance. The equipment is made of two portable containers of the capacity of 250 liters to simulate the air heat source and ground heat source with a system of temperature stabilization, compressor heat pump of the coefficient of performance (COP) of = 4.3, a failsafe system and a control and measurement system.
Źródło:
International Journal of Applied Mechanics and Engineering; 2015, 20, 3; 657-662
1734-4492
2353-9003
Pojawia się w:
International Journal of Applied Mechanics and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Air–water heat pump applied as water boiler in singlefamily house, coefficient of performance analysis under the real conditions
Autorzy:
Lisowska-Lis, A.
Leszczyński, R.
Powiązania:
https://bibliotekanauki.pl/articles/93094.pdf
Data publikacji:
2018
Wydawca:
Państwowa Wyższa Szkoła Zawodowa w Tarnowie
Tematy:
heat pump
air-water
coefficient of performance
COP
pompa ciepła
powietrze-woda
współczynnik wydajności
Opis:
The subject of the research was an air-water heat pump, model PCUW 2.5kW from HEWALEX, installed in a single-family house. The pump is only used for heating water. The research was carried out from 25-08-2017 to 18-09-2017 in the village of Zborowice, in Malopolska region, Poland. The data were recorded from the heat pump system: temperature of the lower heat source (external air), temperature of the upper heat source (water temperature in the tank), time of heat pump was calculated during the analysed cycle of work and electrical energy consumption. The Coefficient Of Performance (COP) of the analysed air-water heat pump was determined. The analysis of the results was carried out using the MATLAB and EXCEL statistical tools. The correlation between COP coefficient and external air temperature is strong: 0.67.
Źródło:
Science, Technology and Innovation; 2018, 3, 2; 58-61
2544-9125
Pojawia się w:
Science, Technology and Innovation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimization of thermo-electric coolers using hybrid genetic algorithm and simulated annealing
Autorzy:
Khanh, D. V. K.
Vasant, P.
Elamvazuthi, I.
Dieu, V. N.
Powiązania:
https://bibliotekanauki.pl/articles/230105.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermo-electric coolers
genetic algorithm
simulated annealing
coefficient of performance
rate of refrigeration
fitness function
Opis:
Thermo-electric Coolers (TECs) nowadays are applied in a wide range of thermal energy systems. This is due to their superior features where no refrigerant and dynamic parts are needed. TECs generate no electrical or acoustical noise and are environmentally friendly. Over the past decades, many researches were employed to improve the efficiency of TECs by enhancing the material parameters and design parameters. The material parameters are restricted by currently available materials and module fabricating technologies. Therefore, the main objective of TECs design is to determine a set of design parameters such as leg area, leg length and the number of legs. Two elements that play an important role when considering the suitability of TECs in applications are rated of refrigeration (ROR) and coefficient of performance (COP). In this paper, the review of some previous researches will be conducted to see the diversity of optimization in the design of TECs in enhancing the performance and efficiency. After that, single-objective optimization problems (SOP) will be tested first by using Genetic Algorithm (GA) and Simulated Annealing (SA) to optimize geometry properties so that TECs will operate at near optimal conditions. Equality constraint and inequality constraint were taken into consideration.
Źródło:
Archives of Control Sciences; 2014, 24, 2; 155-176
1230-2384
Pojawia się w:
Archives of Control Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Operation of an adsorption chiller in different cycle time conditions
Autorzy:
Szyc, M.
Nowak, W.
Powiązania:
https://bibliotekanauki.pl/articles/185219.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
adsorption chiller
coefficient of performance
silica gel adsorption
single stage system
adsorpcja
współczynnik wydajności
żel krzemionkowy
Opis:
This paper is devoted to application of adsorption process for cooling power generation in a cooling devices. Construction and working principle of a water-silica gel adsorption chiller has been presented and the basic refrigeration cycle has been discussed. The article outlines behavior of a single-stage adsorption system influenced by changes in cycle time. The effect of cycle time and inlet chilled water temperatures on the main system performance parameters has been analysed.
Źródło:
Chemical and Process Engineering; 2014, 35, 1; 109-119
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experience in modelling of a single-stage silica gel-water adsorption chiller
Autorzy:
Krzywański, J.
Szyc, M.
Nowak, W.
Kolenda, Z.
Powiązania:
https://bibliotekanauki.pl/articles/298154.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Warmińsko-Mazurski w Olsztynie
Tematy:
low grade thermal energy
waste heat recovery
adsorption chillers
silica gel
coefficient of performance
cooling capacity
Opis:
Heat utilization for cooling capacity production is nowadays a desirable challenge in several industrial applications. There are lots of industrial processes with low parameters of heat generated as by-product, which utilization is very important to improve theirs total energy efficiency. Waste heat driven chillers seem to be great competitors for mechanical chillers. Among them special attention should be paid to adsorption chillers, since they can be powered with low – temperature heat sources. The paper presents a model of a single-stage adsorption chiller with silica gel as adsorbent and water, acting as a refrigerant. The performed model allows to predict the behaviour of the adsorption chiller, among others the main energy efficiency factors, such as coefficient of performance (COP) and cooling capacity (CC) for different working conditions.
Źródło:
Technical Sciences / University of Warmia and Mazury in Olsztyn; 2016, 19(4); 367-386
1505-4675
2083-4527
Pojawia się w:
Technical Sciences / University of Warmia and Mazury in Olsztyn
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling the performance of water-zeolite 13X adsorption heat pump
Autorzy:
Kowalska, K.
Ambrożek, B.
Powiązania:
https://bibliotekanauki.pl/articles/240147.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
desorption
adsorption
mathematical simulation
heat pump
coefficient of performance
desorpcja
adsorpcja
symulacja matematyczna
pompa ciepła
współczynnik wydajności
Opis:
The dynamic performance of cylindrical double-tube adsorption heat pump is numerically analysed using a non-equilibrium model, which takes into account both heat and mass transfer processes. The model includes conservation equations for: heat transfer in heating/cooling fluids, heat transfer in the metal tube, and heat and mass transfer in the adsorbent. The mathematical model is numerically solved using the method of lines. Numerical simulations are performed for the system water-zeolite 13X, chosen as the working pair. The effect of the evaporator and condenser temperatures on the adsorption and desorption kinetics is examined. The results of the numerical investigation show that both of these parameters have a significant effect on the adsorption heat pump performance. Based on computer simulation results, the values of the coefficients of performance for heating and cooling are calculated. The results show that adsorption heat pumps have relatively low efficiency compared to other heat pumps. The value of the coefficient of performance for heating is higher than for cooling
Źródło:
Archives of Thermodynamics; 2017, 38, 4; 191--207
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efektywność pompy ciepła a zużycie CWU
Efficiency of heat pump in relation to domestic hot water consumption
Autorzy:
Gużda, A.
Szmolke, N.
Powiązania:
https://bibliotekanauki.pl/articles/2065482.pdf
Data publikacji:
2018
Wydawca:
Politechnika Częstochowska
Tematy:
cykle poboru CWU
efektywność
PN-EN 16147
współczynnik COP
tapping cycle
efficiency
EN 16147
coefficient of performance
Opis:
Omówiono jeden z obecnie najbardziej efektywnych sposobów wytwarzania ciepłej wody użytkowej (CWU), jakim jest zastosowanie powietrznej pompy ciepła ze zintegrowanym zasobnikiem wodnym. Przedstawiono zasadę działania takiego urządzenia w instalacji przygotowującej ciepłą wodę. Opisano także stanowisko badawcze ze wskazaniem wielkości mierzonych. W części analitycznej artykułu zawarto wybrane wyniki przeprowadzonych pomiarów, których celem było wyznaczenie wskaźników efektywności energetycznej i ekonomicznej zastosowania omawianego rozwiązania. Uzyskane wartości odniesiono do trzech cykli poboru wody, zbliżonych do cykli zalecanych w PN-EN 16147 do badań takich urządzeń.
This paper discusses one of the most effective ways of producing domestic hot water (DHW) based on air-source heat pump with an integrated tank. The principle of operating such equipment is also presented in a hot water installation. Moreover, the experimental set-up is described and values of measurements and reported. In the experimental part, measurements were conducted with the aim of determining the parameters representing the energy and economic efficiency of the proposed solution. The obtained values were compared to the values gained during three tapping cycles which were similar to the recommended reference in EN 16147.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2018, 7, 1; 31--36
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Powietrzne pompy ciepła w audytach energetycznych
Air source heat pump’s in energy audits
Autorzy:
Gużda, A.
Szmolke, N.
Powiązania:
https://bibliotekanauki.pl/articles/2065534.pdf
Data publikacji:
2018
Wydawca:
Politechnika Częstochowska
Tematy:
powietrzna pompa ciepła
audyt energetyczny
efektywność
współczynnik COP
air source heat pump
energetic audit
efficiency
coefficient of performance
Opis:
Pompy ciepła, ze względu na wysoki współczynnik efektywności działania (COP, ang. coefficient of performance), często wybierane są jako wariant przedsięwzięcia mającego na celu poprawę efektywności energetycznej w budynku. W niniejszym artykule przedstawiony został jeden z obecnie najbardziej efektywnych sposobów wytwarzania ciepłej wody użytkowej i ogrzewania budynków, jakim jest zastosowanie powietrznej pompy ciepła. Zaprezentowano zasadę działania takiego urządzenia w instalacji oraz główne parametry wpływające na ich efektywność. Ponadto omówiono zasadność stosowania pomp ciepła, w ujęciu wyboru ich jako wariant przedsięwzięcia termomodernizacyjnego. Omówione zostały zagadnienia związane z prawidłowym doborem urządzenia na etapie obliczeń audytorskich. W końcowej części pracy, autorzy przedstawili przykład obliczeniowy doboru powietrznej pompy ciepła w audycie energetycznym, wraz z określeniem efektu ekologicznego zastosowania tego przedsięwzięcia.
Paper presents one of the most efficient ways of producing hot water and heating of buildings is the present one, which is the use of an air heat pump. They are often chosen to improve energy efficiency in a building. The principle of operation and main parameters influencing their effectiveness were presented. In addition, the use of heat pumps has been discussed in terms of their choice as a variant in energetic audit. The problems related to the correct device selection at the stage of the audit calculations were discussed. In the final part of the paper, the authors presented a computational example of the air-to-water heat pump selection in the energy audit. Moreover the ecological analysis related to different source of energy in building was presented.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2018, 7, 2; 74--80
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Adsorptive solar refrigerators based on composite adsorbents 'silica gel – sodium sulphate'
Autorzy:
Belyanovskaya, Elena A.
Pustovoy, Grigoriy N.
Sukhyy, Kostyntyn M.
Sergiyenko, Yana O.
Yeromin, Oleksandr O.
Prokopenko, Elena .
Gubinsky, Mikhailo V.
Kizek, Ján
Lukáč, Ladislav
Powiązania:
https://bibliotekanauki.pl/articles/396041.pdf
Data publikacji:
2019
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
adsorptive refrigerator
composite adsorbent
coefficient of performance
adsorptive capacity
regeneration temperature
chłodziarka adsorpcyjna
adsorbent
współczynnik wydajności
zdolność adsorpcyjna
temperatura
Opis:
The operation processes of adsorptive solar refrigerators based on composite adsorbents ‘silica gel - sodium sulphate’ were studied. The correlation between the adsorbent composition and the coefficient of the energy performance of the device was stated. As a consequence of the decreasing of adsorbent mass, the coefficient of performance is increased when sodium sulphate content in the composite increased. Effect of the regeneration process parameters on the composite on the coefficient of performance of the adsorptive refrigenerator was stated. The growth of the coefficient of performance is shown to result from decreasing the difference between adsorbent temperature and regeneration temperature from 85 to 55°C. The maximum values of the coefficient of performance of studied solar adsorptive refrigenerator about of 1.14 are stated for composites containing about 20 wt. % silica gel and 80 wt. % sodium sulphate.
Źródło:
Civil and Environmental Engineering Reports; 2019, 29, 3; 200-208
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The use of a heat pump and solar energy in the heat demand
Autorzy:
Noch, T.
Powiązania:
https://bibliotekanauki.pl/articles/104452.pdf
Data publikacji:
2018
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
heat pump
solar energy
Coefficient of Performance
energy performance
heat losses and gains
heat power
heat source
heating
heating appliances
temperature
investment costs
heat demand
Opis:
The article presents the energy performance of a heat pump. The coefficient of performance was taken into account, which is the ratio of the heating energy obtained to the supplied electrical energy necessary for the compressor operation. The focus was on the issue of operating costs of using heat pumps. These costs are mainly influenced by two factors. Firstly, energy performance and the purchase price of electricity. The second factor is investment costs. Heat gains from solar energy were characterized. The value of the solar radiation transmission coefficient for the double glazing was assumed (TR = 0.7). Solar gains were shown in January for windows on the eastern and western facades. The analysis covered the seasonal heat demand for heating. The studies and calculations took into account the occurring heat losses and heat gains from the sun and internal sources with their utilization rate. Particular attention was paid to the fact that the peak power of heating appliances can be calculated by knowing the value of the annual energy demand for heating a building that takes into account the most severe external conditions prevailing in a given climate zone, i.e. the minimum outside temperature.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2018, 65, 1; 99-108
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie pompy ciepła typu powietrze/woda do ogrzewania pojemnościowego wody i chłodzenia powietrza
Application of air-to-water heat pump for domestic hot water preparation and air cooling
Autorzy:
Pater, S.
Ciesielczyk, W.
Powiązania:
https://bibliotekanauki.pl/articles/2073246.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pompa ciepła
dolne źródło ciepła
górne źródło ciepła
współczynnik efektywności pracy
heat pump
bottom heat source
heat sink
coefficient of performance
Opis:
Badano zastosowanie pompy ciepła typu powietrze/woda do ogrzewania wody w zasobniku o pojemności 160 l i jednoczesnego chłodzenia powietrza wewnątrz pomieszczenia laboratoryjnego Wydziału Inżynierii i Technologii Chemicznej Politechniki Krakowskiej. Omówiono wpływ takich parametrów jak temperatura powietrza, temperatura wody w zasobniku, przerwy w pracy pompy ciepła oraz częstotliwość pracy sprężarki na uzyskiwany współczynnik efektywność pracy pompy ciepła (COP). Średnia wartość współczynniki! COP w seriach pomiarowych zawierała się w przedziale od 2,1 do 2,7.
The paper presents the usage of air-to-water heat pump for heating domestic hot water (DHW) in a 160 l storage tank and simultaneous cooling of air inside a laboratory room of the Department of Chemical Engineering and Technology of the Cracow University o f Technology. An influence of such parameters as air temperature, storage tank temperature, heat pump interruptions and compressor operating frequency on the achieved coefficient of performance (COP) of the heat pump is discussed. The average values of COP in the measurement series ranged from 2.1 to 2.7.
Źródło:
Inżynieria i Aparatura Chemiczna; 2017, 3; 98--99
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Speech Intelligibility of the Callsign Acquisition Test in a Quiet Environment
Autorzy:
Blue, M.
Ntuen, C. A.
Letowski, T.
Powiązania:
https://bibliotekanauki.pl/articles/90010.pdf
Data publikacji:
2004
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
callsign test
speech intelligibility
performance intensity coefficient
komunikowanie się
dźwięk
akustyka
zrozumiałość mowy
komunikacja słowna
Opis:
This paper reports on preliminary experiments aimed at standardizing speech intelligibility of military Callsign Acquisition Test (CAT) using average power levels of callsign items measured by the Root Mean Square (RMS) and maximum power levels of callsign items (Peak). The results obtained indicate that at a minimum sound pressure level (SPL) of 10.57 dBHL, the CAT tests were more difficult than NU-6 (Northwestern University, Auditory Test No. 6) and CID-W22 (Central Institute for the Deaf, Test W-22). At the maximum SPL values, the CAT tests reveal more intelligibility than NU-6 and CID-W22. The CAT-Peak test attained 95% intelligibility as NU-6 at 27.5 dBHL, and with CID-W22, 92.4% intelligibility at 27 dBHL. The CAT-RMS achieved 90% intelligibility when compared with NU-6, and 87% intelligibility score when compared with CID-W22; all at 24 dBHL.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2004, 10, 2; 179-189
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Procedura optymalizacji doboru zbiornika buforowego współpracującego z pompą ciepła
Optimisation procedure of selection of the buffer bin cooperating with the heat pump
Autorzy:
Rutkowski, K.
Vogelgesang, J.
Latała, H.
Kempkiewicz, K.
Powiązania:
https://bibliotekanauki.pl/articles/287068.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
obiekt szklarniowy
wielkość zasobnika buforowego
pompa ciepła
współczynnik efektywności energetycznej
COP
greenhouse
size of a buffer bin
heat pump
coefficient of performance
Opis:
W pracy przedstawiono optymalizację doboru zbiornika buforowego dla pompy ciepła włączonej w układ grzejny obiektu szklarniowego. Badania oraz optymalizację przeprowadzono podczas pracy pompy współpracującej z trzema wybranymi pojemnościami zbiornika buforowego. Ustalenie wielkości zbiornika buforowego w systemie grunt – woda wymaga uwzględnienia wielu czynników zarówno od strony układu grzewczego szklarni, układu pobierania ciepła z gruntu, jak również samej pompy ciepła. Rozważano przypadek graniczny – zapotrzebowanie na ciepło, które jeszcze może dostarczyć pompa ciepła w systemie monowalentnym. Przyjęto, że nadrzędnym kryterium powinna być maksymalizacja efektywności COP, ale z równoczesnym zapewnieniem zdolności do generowania przez układ ustalonych, granicznych ilości ciepła. Uwzględniono różnice taryf cen energii elektrycznej, także sformułowano inne ograniczenia związane z doborem zbiornika buforowego. Wielkość zbiornika jest między innymi konsekwencją założeń dotyczących strategii eksploatacji dolnego źródła ciepła. Zagadnienie to w pracy rozszerzono. Stwierdzono, że wielkość zbiornika buforowego zależy od lokalnych własności źródła dolnego, które w skali kilku sezonów grzewczych nie ma stacjonarnego charakteru. Stąd zbiornik buforowy powinien posiadać możliwość wydzielania mniejszych objętości stosowanych w zależności od ilości energii pobieranej z jednego metra bieżącego dolnego źródła ciepła. Następnie korzystając z symulacji komputerowych, wykazano, że istnieją uzasadnione ograniczenia dla stosowania zbiorników zbyt małych lub zbyt dużych. W wytypowanym przedziale należy poszukiwać optymalnego zbiornika na drodze doświadczalnej, z uwagi na udział zbyt wielu zmiennych zmniejszających precyzję drogi obliczeniowej.
The paper presents optimisation of selection of the buffer bin for the heat pump connected to the heating system of a greenhouse. The research and optimisation was carried out during operation of the pump, which cooperated with three selected volumes of the buffer bin. Determination of the buffer bin size in the ground-water system requires including many factors both coming from the heating system of a greenhouse, the heat collection from the ground system as well as the heat pump itself. A boundary case of the heat demand, which still may be delivered by the heat pump in the monovalent system was considered. It was assumed that maximization of COP effectiveness should be a superior criterion but with simultaneous ensuring the ability to generate by the system determined, borderline amount of heat. Differences of price lists of electric energy were included; moreover, other limitations related to selection of the buffer bin were formulated. A bin size, inter alia, results from assumptions concerning the strategy of exploitation of a lower heat source. This issue was extended in the paper. It was found that the buffer bin size depends on the local properties of the lower source, which in the few heating seasons scale has no stationary character. Therefore, a buffer bin should have a possibility of separating smaller applied volumes depending on the amount of the collected energy from one current meter of the lower heat source. Then, using a computer simulation, it was proved that there are justified limitations for using too small or too big bins. In the selected range one should search for an optimal bin by means of an experiment, due to participation of too big number of variables, which decrease the cultivation precision.
Źródło:
Inżynieria Rolnicza; 2013, R. 17, nr 3, t. 1, 3, t. 1; 329-343
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hybrid cascade refrigeration systems for refrigeration and heating
Autorzy:
Megdouli, K.
Ezzaalouni, Y.
Nahdi, E.
Mhimid, A.
Kairouani, L.
Powiązania:
https://bibliotekanauki.pl/articles/240448.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ejector cycle
heat pump
comparison
refrigerant
coefficient of performance
irreversibility
exergy loss
second law efficiency
pompa ciepła
porównanie
czynnik chłodniczy
współczynnik
efektywność
nieodwracalność
Opis:
In this study a cooling ejector cycle coupled to a compression heat pump is analyzed for simultaneous cooling and heating applications. In this work, the influence of the thermodynamic parameters and fluid nature on the performances of the hybrid system is studied. The results obtained show that this system presents interesting performances. The comparison of the system performances with hydrofluorocarbons (HFC) and natural fluids is made. The theoretical results show that the a low temperature refrigerant R32 gives the best performance.
Źródło:
Archives of Thermodynamics; 2018, 39, 2; 73-95
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies