Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "clothing microclimate" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
A Comparison of Skin Temperatures and Clothing Microclimate During Moderate Intermittent Exercise in the Cold Between One and Two Layers of Cotton and Polypropylene Underwear
Autorzy:
Ha, M.
Tokura, H.
Yoden, K.
Holmer, I.
Powiązania:
https://bibliotekanauki.pl/articles/90615.pdf
Data publikacji:
1998
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
mean skin temperature
clothing microclimate
cotton
polypropylene
underwear
średnia temperatura skóry
bawełna
ubranie
polipropylen
Opis:
The purpose of this study was to compare the effects of 2 kinds of underwear made from hydrophobic and hydrophilic fabrics on the mean skin temperatures and clothing microclimate (temperature, humidity) in participants performing intermittent exercise in cold environmental conditions. One or 2 layers of cotton underwear (C1, C2) with a 2-piece long-sleeved shirt and long-legged trousers, and 1 or 2 layers of polypropylene underwear (P1, P2) with a 2-piece long-sleeved shirt and long-legged trousers were used as experimental underwear. In addition, the participants wore a 2-piece ski suit as 100% polyester clothing including 100% polyester padding. Ten young adult females volunteered as participants. The experiments were performed in a climatic chamber at an ambient temperature (Ta) of 0°C and an air velocity of 0.26 m s-1. The major findings are summarized as follows: (a) Although the clothing microclimate humidity was not different within the ski suit of outer clothing between C1 and P1, it was significantly higher in P2 than in C2; (b) Clothing microclimate temperature inside the ski suit did not differ between C1 and P1, whereas it was significantly higher in P2 than in C2; (c) The thermal gradient between innermost and outermost of clothing microclimate at back level did not show any difference between C1 and P1, but it was significantly higher in C2 than in P2. These results are discussed in terms of thermal physiology and clothing sciences.
Źródło:
International Journal of Occupational Safety and Ergonomics; 1998, 4, 3; 347-362
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Effects of Local Cooling on Thermophysiological Response in Participants Wearing Dust-Free Garments
Autorzy:
Kwon, O. K.
Kwon, A. H.
Kato, M.
Hayashi, C.
Tokura, H.
Powiązania:
https://bibliotekanauki.pl/articles/90860.pdf
Data publikacji:
1998
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
dust-free garment
frozen gel strip
skin temperature
heart rate
clothing microclimate
odzież bezpyłowa
temperatura ciała
obciążenie cieplne
Opis:
This study was designed to find the effects of two kinds of dust-free garments with (A) and without (B) frozen gel strip (FGS), and half-naked clothing (brassiere and shorts; C) on thermophysiological parameters and on temperature and humidity within clothing. The heart rate, rectal, and skin temperatures as well as sweat rate and clothing microclimate were measured during 140 min in 9 healthy females. Inquiries were also made into the subjective rating of thermal, humidity, and comfort sensations. The main findings in our experiments are as follows: (a) Physiological parameters such as rectal and skin temperatures (chest and forehead), heart rate, and sweat rate were clearly lowest in garb C, intermediate in garb A, and highest in garb B throughout the experiment; (b) Temperature and humidity within clothing were lower in garb A than in garb B; (c) More than half of the 9 participants decreased thermal sensation by wearing garb A. These results suggest that the usage of FGS could improve the heat load in lightly working participants wearing dust-free garments.
Źródło:
International Journal of Occupational Safety and Ergonomics; 1998, 4, 1; 57-67
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of Clothing Comfort Properties Using the Cycloergometer Test
Ocena właściwości odpowiadających za komfort odzieży z zastosowaniem badania z udziałem cykloergometru
Autorzy:
Witkowska, Beata
Jasińska, Izabela
Powiązania:
https://bibliotekanauki.pl/articles/232424.pdf
Data publikacji:
2020
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
biophysical comfort
clothing comfort
humidity balance
microclimate
sports underwear
komfort biofizyczny
komfort odzieży
równowaga wilgotności
mikroklimat
bielizna sportowa
Opis:
The aim of study was to present an evaluation of sports underwear under different conditions and applying two measurement techniques. The test was performed on a ergometer simulating real conditions of wearing clothes. Moreover, the material parameters of knitted fabric selected were evaluated according to standards. The utility tests performed by the ergometer allow one to assess fabric under the action of the human thermoregulation mechanism. and therefore such tests more effectively characterise the article under testing. Test results of the underclothing micro-climate of sports underwear showed a statistically significant dependence on the person participating in the tests.
Publikacja miała na celu prezentację analizy i oceny bielizny sportowej poddanej badaniu z zastosowaniem dwóch technik pomiarowych w zróżnicowanych warunkach prowadzenia badania. Pomiary były wykonane z udziałem cykloergometru, co pozwoliło symulować rzeczywiste warunki użytkowania odzieży. Ponadto dokonano oceny wybranych właściwości dzianin z których skonfekcjonowana była bielizna. Badania użytkowe wykonane z zastosowaniem cykloergometru pozwoliły dokonać oceny badanych wyrobów w rzeczywistych warunkach, gdy podlegają one oddziaływaniu mechanizmu termoregulacji człowieka uczestniczącego w teście. Powyższe podejście pozwoliło na efektywną ocenę przedmiotowych wyrobów. Wyniki badania warunków panujących w mikroklimacie pododzieżowym dla badanej bielizny sportowej wykazały statystycznie istotną zależność od cech osobniczych osoby uczestniczącej w teście.
Źródło:
Fibres & Textiles in Eastern Europe; 2020, 4 (142); 101-106
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Odzież ciepłochronna w aspekcie zmian wymagań w normie PN-EN 342
Clothing protecting against cold in terms of changes in the requirements of the PN-EN 342 standard
Autorzy:
Młynarczyk, Magdalena
Dąbrowska, Anna
Powiązania:
https://bibliotekanauki.pl/articles/2202787.pdf
Data publikacji:
2020
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
odzież ciepłochronna
środowisko zimne
mikroklimat zimny
izolacyjność cieplna
normy polskie
clothing protecting against cold
cold environment
cold microclimate
thermal insulation
Polish standards
Opis:
Zgodnie z obowiązującymi w Polsce przepisami prawa pracodawca zobowiązany jest zapewnić pracownikowi bezpieczne warunki pracy. W przypadku narażenia pracownika na szkodliwe oddziaływanie środowiska zimnego, pracodawca musi zapewnić mu odpowiednio dobraną ciepłochronną odzież, spełniającą wymagania zapisów normy PN-EN 342:2018-01. Z uwagi na istotne zmiany, jakie zostały wprowadzone w nowym wydaniu wymienionego dokumentu, w szczególności w aspekcie metodyki badań izolacyjności cieplnej z wykorzystaniem manekina termicznego, w artykule zamieszczono informacje nt. różnic pomiędzy wydaniami normy PN-EN 342 z 2006 r. oraz 2018 r. Wyjaśniono również pojęcia związane z oceną skuteczności ochrony odzieży przed zimnem.
In accordance with the Polish law, employers are expected to provide employees with safe working conditions. In case of the possible exposure of the employees to the harmful influence of the cold environment, the employer has to provide them with properly selected protective clothing against cold, and in this instance "properly" equals meeting the requirements of PN-EN 342:2018-01. Due to significant changes that were introduced in the new edition of the above-mentioned document, in particular in relation to methodology of testing of thermal insulation with a use of a thermal manikin, the following publication contains Information about the differences between the editions of the PN-EN 342 standard from 2006 and 2018. The concepts related to the assessment of the performance of clothing protecting against cold were also explained.
Źródło:
Bezpieczeństwo Pracy : nauka i praktyka; 2020, 11; 10-13
0137-7043
Pojawia się w:
Bezpieczeństwo Pracy : nauka i praktyka
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies