- Tytuł:
- Anatomical protocol for gait analysis: joint kinematics measurement and its repeatability
- Autorzy:
-
Żuk, M.
Trzeciak, M. - Powiązania:
- https://bibliotekanauki.pl/articles/281538.pdf
- Data publikacji:
- 2017
- Wydawca:
- Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
- Tematy:
-
joint kinematics
gait analysis protocol
repeatability
anatomical protocol
marker-set
motion capture system - Opis:
- International Society of Biomechanics has proposed a general reporting standard for joint kinematics based on anatomical reference frames. Nevertheless, the gait analysis protocols based on this standard are still poorly reported. The purpose of the current study is to propose and preliminarily assess the potential of an anatomically based ISB 6-DOF protocol, which combines the ISB reporting standard together with a marker cluster technique. The proposed technical marker set enables full description of the lower limb kinematics (including three-dimensional ankle-foot complex rotations) according to the current biomechanical recommendation. The marker set provides a clinically acceptable inter-trial repeatability and minimal equipment requirements.
- Źródło:
-
Journal of Theoretical and Applied Mechanics; 2017, 55, 1; 369-376
1429-2955 - Pojawia się w:
- Journal of Theoretical and Applied Mechanics
- Dostawca treści:
- Biblioteka Nauki