Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "capture system" wg kryterium: Temat


Tytuł:
Anatomical protocol for gait analysis: joint kinematics measurement and its repeatability
Autorzy:
Żuk, M.
Trzeciak, M.
Powiązania:
https://bibliotekanauki.pl/articles/281538.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
joint kinematics
gait analysis protocol
repeatability
anatomical protocol
marker-set
motion capture system
Opis:
International Society of Biomechanics has proposed a general reporting standard for joint kinematics based on anatomical reference frames. Nevertheless, the gait analysis protocols based on this standard are still poorly reported. The purpose of the current study is to propose and preliminarily assess the potential of an anatomically based ISB 6-DOF protocol, which combines the ISB reporting standard together with a marker cluster technique. The proposed technical marker set enables full description of the lower limb kinematics (including three-dimensional ankle-foot complex rotations) according to the current biomechanical recommendation. The marker set provides a clinically acceptable inter-trial repeatability and minimal equipment requirements.
Źródło:
Journal of Theoretical and Applied Mechanics; 2017, 55, 1; 369-376
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zasobometr - przyrząd nowej generacji do badań nad chodem człowieka
Motion resources apparatus - new generation for investigation of human gait
Autorzy:
Jaworek, K. P.
Piwnik, J.
Powiązania:
https://bibliotekanauki.pl/articles/275513.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
biomechanika chodu człowieka
systemy rejestracji ruchu
biomechanics of human gait
motion capture system
Opis:
W pracy podano nowe pojęcia, dotychczas nie stosowane w biomechanice chodu człowieka, zwane przez autorów pracy zasobami ruchu. Zasoby ruchu kończyn dolnych człowieka pozwalają - nie tylko na podstawie pomiarów kinematycznych dokonanych w czasie rzeczywistym - monitorować, kontrolować i oceniać w sposób dynamiczny(!) stan i zmianę zasobu ruchu kończyn dolnych człowieka w warunkach klinicznych jak i polowych (na stadionach po różnorodnej powierzchni np. błocie, śniegu, trawie, schodach itp.). W pracy zaproponowano innowacyjną aparaturę nowej generacji, do badania chodu człowieka zwaną zasobometrem. Pracuje on w trybie on-line i pozwala oceniać chód człowieka - równocześnie dla obu kończyn dolnych. Cena rynkowa zasobometru jest kilkanaście razy mniejsza aniżeli systemów rejestracji ruchu jak np. włoski system optoelektroniczny ELITE-3D - produkowany przez włoską firmę BTS z Mediolanu.
On this paper a new notion, which has never been applied in investigation of human gait, is described. This is MOTION RESOURCES COEFFICENT named in polish language ZASOBY RUCHU. A new Motion Resources Apparatus (the MRA) for research, investigation and assessing human gait - in natural condition - has been presented. The MRA is an apparatus of a new generation which allows to reduce significantly cost of investigation multistep of human gait - in natural condition.
Źródło:
Pomiary Automatyka Robotyka; 2010, 14, 2; 527-538
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zakażenia wirusem brodawczaka ludzkiego – współczesne metody diagnostyczne
Human papillomavirus infection – current diagnostic techniques
Autorzy:
Skrajna, Adrianna
Maździarz, Agnieszka
Reinholz-Jaskólska, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/1030768.pdf
Data publikacji:
2010
Wydawca:
Medical Communications
Tematy:
Hybrid Capture System
PCR
cervical cancer
human papillomavirus
mRNA
rak szyjki macicy
wirus brodawczaka ludzkiego
Opis:
Human papillomavirus (HPV) belongs to the family of DNA viruses. Infection by HPV is associated with the development of benign or malignant lesions within mucosal membrane and skin of the genitals, anus, head and neck. Presence of the virus, particularly of the highly oncogenic variants in epithelial cells of uterine cervix directly influences the development of cervical cancer. In a considerable proportion of cases, HPV infections are asymptomatic and this is probably associated with lack of proliferation phase of viral life cycle, or may be transient, which greatly complicates early detection of the virus. Diagnostic techniques enabling diagnosis of HPV infection include: cytological exam (PAP smear), colposcopy, histological study, as well as increasingly sophisticated molecular techniques, enabling detection of viral DNA when other indices of infection are lacking. These techniques include Southern Blot, Dot Blot, in situ hybridization, polymerase chain reaction (PCR) and Hybrid Capture System I and II (HCI, HCII). Increasingly often authors refer to tests based on isolation of viral mRNA (PreTect HPV-Proofer test). These techniques detect integrated form of HPV, the so-called episomal form of the virus. In general opinion, the presence of HPV in this form is directly associated with progression of lesions developing as a result of this infection. While the PreTect HPV-Proofer test detects a smaller number of cases of HPV infection, its use enables selection of patients most at risk of developing cervical cancer.
Wirus brodawczaka ludzkiego (HPV) należy do grupy DNA wirusów. Infekcje wirusem brodawczaka ludzkiego wiążą się z występowaniem łagodnych lub złośliwych zmian w obrębie błon śluzowych i skóry narządów płciowych, odbytu, jak również głowy i szyi. Obecność wirusa, szczególnie typów wysokoonkogennych, w komórkach nabłonka szyjki macicy bezpośrednio wpływa na rozwój raka szyjki macicy. Zakażenia HPV w dużym odsetku przebiegają bezobjawowo i jest to najprawdopodobniej związane z niewystąpieniem fazy proliferacyjnej cyklu życiowego wirusa, a także mają charakter przejściowy, co znacznie utrudnia wczesną identyfikację wirusa. Wśród metod diagnostycznych umożliwiających rozpoznanie zakażenia wymienia się badanie cytologiczne, kolposkopię, badanie histologiczne, a także coraz doskonalsze metody molekularne, które pozwalają wykryć wirusowe DNA w przypadkach braku innych wykładników zakażenia. Do metod tych zalicza się: Southern Blot, Dot Blot, hybrydyzacje in situ, polymerase chain reaction (PCR), Hybrid Capture System I i II (HCI, HCII). Coraz częściej wspomina się o testach opartych na izolacji mRNA wirusa HPV (PreTect HPV-Proofer test). Metody te wykrywają zintegrowaną formę HPV, tzw. formę episomalną wirusa. Uważa się, że obecność wirusa HPV w tej postaci jest bezpośrednio związana z progresją zmian powstałych na podłożu tego zakażenia. Co prawda przy pomocy testu PreTect HPV-Proofer wykrywa się mniejszą liczbę zakażeń HPV, ale stosując go, można wyodrębnić grupę pacjentek najbardziej narażonych na raka szyjki macicy.
Źródło:
Current Gynecologic Oncology; 2010, 8, 1; 40-46
2451-0750
Pojawia się w:
Current Gynecologic Oncology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficiency of Supercritical Coal Power Stations with Integrated CO2 Capture and Compression Systems Based on Oxy-combustion Technology
Efektywność nadkrytycznych elektrowni węglowych zintegrowanych z instalacjami wychwytu i sprężania CO2 w technologii oxy-combustion
Autorzy:
Kotowicz, J.
Brzęczek, M.
Job, M.
Powiązania:
https://bibliotekanauki.pl/articles/397478.pdf
Data publikacji:
2016
Wydawca:
ENERGA
Tematy:
supercritical coal power stations
oxy-combustion technology
CO2
capture system
nadkrytyczne elektrownie węglowe
technologia oxy-spalania
instalacja wychwytu CO2
Opis:
This paper presents supercritical coal-fired power stations integrated withCO2 capture and compression systems based on oxy-combustion. The efficiency and key performance indicators of analysed units with different oxygen generation methods have been compared. The following methods are presented: cryogenic, cryogenic-membrane based on polymer membranes, and membrane methods with three-end and four-end HTM membranes. Loss of efficiency in reference to a plant operating in classic arrangement (without CO2 capture) is given for all analysed systems. The main thermodynamic parameters of the considered power units were presented. The paper is a summary of results of the strategic programme ”Development of oxygen combustion technology for pulverised- and fluidised-bed boilers with integrated CO2 capture” carried out by the authors.
W artykule przedstawiono nadkrytyczne elektrownie węglowe zintegrowane z instalacjami wychwytu i sprężania CO2 w technologii oxy-spalania. Porównano efektywność oraz główne parametry pracy analizowanych bloków dla różnych metod produkcji tlenu. Przedstawiono metody: kriogeniczną, kriogeniczno-membranową wykorzystującą membrany polimerowe i metody membranowe wykorzystujące membrany ceramiczne HTM typu three-end oraz four-end. Pokazano utratę sprawności wszystkich analizowanych układów względem elektrowni pracującej w trybie klasycznym (bez instalacji wychwytu CO2). Przedstawiono główne parametry termodynamiczne rozpatrywanych bloków. Praca jest syntezą rezultatów w realizowanym przez autorów projekcie strategicznym „Opracowanie technologii spalania tlenowego dla kotłów pyłowych i fluidalnych zintegrowanych z wychwytem CO2”.
Źródło:
Acta Energetica; 2016, 1; 69-76
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermodynamic analysis of cycle arrangements of the coal-fired thermal power plants with carbon capture
Autorzy:
Kindra, Vladimir Olegovich
Milukov, Igor Alexandrovich
Shevchenko, Igor Vladimirovich
Shabalova, Sofia Igorevna
Kovalev, Dmitriy Sergeevich
Powiązania:
https://bibliotekanauki.pl/articles/1955057.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
combined cycle power plant
carbon capture
storage system
precombustion capture
post-combustion capture
oxy-fuel combustion
Opis:
The electricity production by combustion of organic fuels, especially coal, increases the atmospheric CO2 content, which contributes to global warming. The greenhouse gas emissions by the power production industry may be reduced by the application of CO2 capture and storage systems, but it remarkably decreases the thermal power plant (TPP) efficiency because of the considerable increase of the auxiliary electricity requirements. This paper describes the thermodynamic analysis of a combined cycle TPP with coal gasification and preliminary carbon dioxide capture from the syngas. Utilization of the heat produced in the fuel preparation increases the TPP net efficiency from 42.3% to 47.2%. Moreover, the analysis included the combined cycle power plant with coal gasification and the CO2 capture from the heat recovery steam generator exhaust gas, and the oxy-fuel combustion power cycle with coal gasification. The coal-fired combined cycle power plant efficiency with the preliminary CO2 capture from syngas is 0.6% higher than that of the CO2 capture after combustion and 9.9% higher than that with the oxy-fuel combustion and further CO2 capture. The specific CO2 emissions are equal to 103 g/kWh for the case of CO2 capture from syngas, 90 g/kWh for the case of CO2 capture from the exhaust gas and 9 g/kWh for the case of oxy-fuel combustion.
Źródło:
Archives of Thermodynamics; 2021, 42, 4; 103-121
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermodynamic analysis of an innovative steam turbine power plant with oxy-methane combustors
Autorzy:
Kindra, Vladimir Olegovich
Osipov, Sergey Konstantinovich
Zlyvko, Olga Vladimirovna
Shcherbatov, Igor Alexandrovich
Sokolov, Vladimir Petrovich
Powiązania:
https://bibliotekanauki.pl/articles/1955067.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Combined cycle power plant
carbon capture
storage system
precombustion capture
post-combustion capture
oxy-fuel combustion
Opis:
The Rankine cycle steam turbine power plants make a base for world electricity production. The efficiency of modern steam turbine units is not higher than 43–45%, which is remarkably lower compared to the combined cycle power plants. However, an increase in steam turbine power plant efficiency could be achieved by the rise of initial cycle parameters up to ultra-supercritical values: 700–780◦C, 30–35 MPa. A prospective steam superheating technology is the oxy-fuel combustion heating in a sidemounted combustor located in the steam pipelines. This paper reviews thermal schemes of steam turbine power plants with one or two side-mounted steam superheaters. An influence of the initial steam parameters on the facility thermal efficiency was identified and primary and secondary superheater parameters were optimized. It was found that the working fluid superheating in the side-mounted oxy-methane combustors leads to an increase of thermal efficiency higher than that with the traditional boiler superheating in the initial temperature ranges of 700–780◦C and 660–780◦C by 0.6% and 1.4%, respectively.
Źródło:
Archives of Thermodynamics; 2021, 42, 4; 123-140
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie systemów przestrzennej analizy ruchu na przykładzie systemów optycznych i akcelerometrycznych
Comparison of spatial motion analysis on the example of optical and accelerometric systems
Autorzy:
Zaborska, K.
Jochymczyk-Woźniak, K.
Wodarski, P.
Bieniek, A.
Powiązania:
https://bibliotekanauki.pl/articles/98710.pdf
Data publikacji:
2015
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
system do analizy ruchu
motion capture
Xsens
system for motion analysis
Opis:
Artykuł prezentuje wyniki porównania dwóch systemów służących do analizy ruchu człowieka- optycznego DTrack2 oraz akcelerometrycznego Xsens. Badania przeprowadzono w Wirtualnej Jaskini (zwanej systemem Cave) znajdującej się w Centrum Nowych Technologii w Gliwicach. Porównania dokonano na podstawie wielkości czasowo - przestrzennych wyznaczonych podczas badań doświadczalnych i obliczonych w programie Matlab. Porównanie danych przedstawiono na podstawie obliczonego błędu średniokwadratowego oraz współczynnika korelacji Pearsona.
The paper presents the results of a comparison of two human motion analysis systems - optical DTrack2 and accelerometric Xsens. The study was conducted in Technopark Virtual Cave (called Cave system) in Gliwice. The comparison was made on the time-space basis, which were designated during the experiment and calculated in Matlab. Comparison of the data was presented on the basis of the calculated mean square error and the Pearson correlation coefficient.
Źródło:
Aktualne Problemy Biomechaniki; 2015, 9; 129-134
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena wpływu nieprawidłowego rozmieszczenia znaczników ruchu na wyniki pomiarów wielkości kinematycznych w systemie APAS
Estimation of influence of incorrect marker location on results of kinematic quantities measurements carried out in the APAS system
Autorzy:
Michnik, R.
Jurkojć, J.
Sacha, E.
Powiązania:
https://bibliotekanauki.pl/articles/99079.pdf
Data publikacji:
2008
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
biomechanika
analiza ruchu
pomiar ruchu
system APAS
biomechanics
gait analysis
motion capture
APAS system
Opis:
W ramach pracy przedstawiono wyniki badań pozwalających na ocenę wpływu nieprawidłowego rozmieszczenia znaczników ruchu na wyniki pomiarów wielkości kinematycznych w systemie APAS. Analizę ruchu przeprowadzono umieszczając na ciele badanej osoby 15 markerów zgodnie z modelem Vaughan’a oraz dwa dodatkowe markery w pobliżu stawu kolanowego oraz stawu skokowego przesunięte do przodu o 3 cm w płaszczyźnie strzałkowej w stosunku do prawidłowo naklejonych markerów. Otrzymane wyniki pomiarów zarejestrowane dla chodu z prawidłowo i nieprawidłowo rozmieszczonymi markerami porównano ze sobą.
Results of research enabling assessment of influence of incorrect marker location on results of kinematic quantities measurements, carried out by APAS system, are presented in the paper. Motion analysis was conducted with the use of 15 markers placed on the body in accordance with Vaughan model. Additionally two another markers were situated 3 cm forward in saggital plane (with respect to correctly situated markers) on the knee and ankle joints. For all obtained results the comparative analysis was carried out.
Źródło:
Aktualne Problemy Biomechaniki; 2008, 2; 105-110
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Np-237 incineration study in various beams in ADS setup QUINTA
Autorzy:
Kilim, S.
Strugalska-Gola, E.
Szuta, M.
Bielewicz, M.
Tyutyunnikov, S. I.
Furman, W. I.
Adam, J.
Stegailov, V. I.
Powiązania:
https://bibliotekanauki.pl/articles/146295.pdf
Data publikacji:
2018
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
Np-237
accelerator-driven system
ADS
gamma-ray spectrometry
fission
neutron capture
Opis:
Neptunium-237 samples were irradiated in a spallation neutron fi eld produced in accelerator-driven system (ADS) setup QUINTA. Five experiments were carried out on the accelerators at the JINR in Dubna – one in carbon (C6+), three in deuteron, and one in a proton beam. The energy in carbon was 24 GeV, in deuteron 2, 4 and 8 GeV, respectively, and 660 MeV in the proton beam. The incineration study method was based on gamma-ray spectrometry. During the analysis of the spectra several fi ssion products and one actinide were identifi ed. Fission product activities yielded the number of fi ssions. The actinide (Np-238), a result of neutron capture by Np-237, yielded the number of captures. The main goal of this work was to fi nd out if and how the incineration rate depended on parameters of the accelerator beam.
Źródło:
Nukleonika; 2018, 63, 1; 17-22
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System effects of primary energy reduction connected with operation of the CHP plants
Autorzy:
Ziębik, A.
Gładysz, P.
Powiązania:
https://bibliotekanauki.pl/articles/240054.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cogeneration
trigeneration
amine CO2 capture
system effects
kogeneracja
trójgeneracja
aminy
wychwyt CO2
efekty systemowe
Opis:
The paper is devoted to explication of one of the advantages of heat and electricity cogeneration, rarely considered in technical literature. Usually attention is paid to the fact that heat losses of the heat distribution network are less severe in the case of cogeneration of heat in comparison with its separate production. But this conclusion is also true in other cases when the internal consumption of heat is significant. In this paper it has been proved in the case of two examples concerning trigeneration technology with an absorption chiller cooperating with a combined heat and power (CHP) plant and CHP plant integrated with amine post-combustion CO2 processing unit. In both considered cases it might be said that thanks to cogeneration we have to do with less severe consequences of significant demand of heat for internal purposes.
Źródło:
Archives of Thermodynamics; 2017, 38, 2; 61-79
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies