Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "capacity method" wg kryterium: Temat


Tytuł:
Simulation and discretization of random field in the slip-line method
Autorzy:
Przewłócki, J.
Powiązania:
https://bibliotekanauki.pl/articles/240960.pdf
Data publikacji:
2003
Wydawca:
Polska Akademia Nauk. Instytut Budownictwa Wodnego PAN
Tematy:
bearing capacity
method of characteristics
random field
Opis:
The paper deals with the problem of bearing capacity of a strip footing based on the random subsoil. The solution has been obtained in a framework of the slip-line method. In order to include randomness of the soil medium, a modification of the method of characteristics is proposed. In such an approach, the stochastic finite difference method based on the Monte Carlo technique has been adopted. It enables including a spatial variability of soil properties into the analysis and to determine its influence on the variance of the ultimate collapse load. It is assumed that the soil medium is purely cohesive and only its cohesion can be considered as a random field. The simulation algorithm of multi-dimensional random field, based on the diagonalisation of the covariance matrix by a transformation using a lower-triangle matrix is described. The problems of the medium discretization and stabilization of the solution are discussed.
Źródło:
Archives of Hydro-Engineering and Environmental Mechanics; 2003, 50, 4; 343-358
1231-3726
Pojawia się w:
Archives of Hydro-Engineering and Environmental Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Określanie parametrów termofizycznych polimetakrylanu metylu, polistyrenu oraz stali stopowej 1H18N9T metodą chwilowego źródła ciepła
Identification of thermophysical parameters (PMMA), extruded polystyrene (XPS) and alloy steel 1H18N9T by using a heat pulse method
Autorzy:
Zmywaczyk, J.
Koniorczyk, P.
Gaj, J.
Powiązania:
https://bibliotekanauki.pl/articles/209633.pdf
Data publikacji:
2007
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
nieustalone przewodzenie ciepła
przewodność cieplna
dyfuzyjność cieplna
pojemność cieplna
materiały termoizolacyjne
kompleksowe badania właściwości termofizycznych
metoda chwilowego źródła ciepła
heat transfer
thermal conductivity
thermal diffusivity
heat capacity
thermal insulation
heat pulse method
Opis:
W pracy przedstawiono metodę chwilowego źródła ciepła do jednoczesnego określania trzech parametrów termofizycznych przewodności cieplnej k, dyfuzyjności a oraz ciepła właściwego cp w czasie jednego pomiaru. Metoda jest obecnie stosowana na świecie nie tylko dla materiałów termoizolacyjnychale również dla stopów metali. Cechuje ją krótki czas pomiaru. Szczególnie ważna jest metodologia badań. W ostatnich latach dokonał się w tym zakresie duży postęp. W pracy przedstawiono wyniki badań k, a i cp dla polimetakrylanu metylu, tzw. pleksiglasu (PMMA), polistyrenu ekstrudowanego firmy BASF (XPS 3035 CS) oraz stali stopowej 1H18N9T. Badania k, a i cp w funkcji grubości próbki przeprowadzono w temperaturze pokojowej dla próbek w kształcie walca o średnicy 50 mm dla PMMA, 1H18N9T i 200 mm dla XPS. Grubości próbek zawierały się w granicach od 2 mm do 30 mm.
A heat pulse method is presented for simulatneous determination of three thermophysical parameters, i. e., the thermal conductivity k, the thermal diffusivity a, and the specific heat cp. All of the thermophysical parameters were determined during a single measurement for a given sample thickness. The method is now commonly used not only for hear insulating materials but also for metal alloys as well. As advantages of the method one can include its wide application possibilities and a short time of measurement duration. The methodology is of vital importance. The paper presents the measurement results of k, a, and cp for plexiglass (PMMA), extruded polystyrene (XPS), and alloy steel 1H18N9T.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2007, 56, 3; 243-256
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The meaning of different limiters relations for defining public transport routes capacity
Znaczenie powiązania różnych ograniczników dla określania przepustowości tras komunikacyjnych
Autorzy:
Molecki, A.
Powiązania:
https://bibliotekanauki.pl/articles/375156.pdf
Data publikacji:
2007
Wydawca:
Politechnika Śląska. Wydawnictwo Politechniki Śląskiej
Tematy:
system komunikacyjny
przepustowość drogi
ogranicznik przepustowości
metoda Monte Carlo
transportation system
road capacity
limiter of capacity
Monte Carlo method
Opis:
The mutual affecting of different limiters of capacity is a very important feature, which makes difficult the right appreciation of the transport systems. In most cases, there is no way to use procedures which define relations by correlation coefficients etc. Completely divergent character of limiters induce that only way of effective appreciation is modeling by Monte Carlo simulations.
Wzajemne oddziaływanie różnych ograniczników przepustowości jest bardzo ważną cechą utrudniającą właściwą ocenę układów komunikacyjnych. W większości przypadków procedury określające powiązania za pomocą współczynników korelacji nie mają zastosowania itp. Całkowicie rozbieżny charakter występujących ograniczników powoduje, że jedyną drogą prowadzącą do skutecznej oceny staje się modelowanie symulacyjne Monte Carlo.
Źródło:
Transport Problems; 2007, 2, 1; 95-100
1896-0596
2300-861X
Pojawia się w:
Transport Problems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of 2,5-dichloro-1,4-benzoquinone on jack bean urease activity. Inhibitory effect, total reducing capacity and DPPH radical scavenging activity
Autorzy:
Kot, Mirosława
Olech, Zofia
Powiązania:
https://bibliotekanauki.pl/articles/1039867.pdf
Data publikacji:
2011
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
reducing capacity
inhibition
urease
Folin-Ciocalteu method
2,5-dichloro-1,4-naphthoquinone
DPPH scavenging activity
Opis:
Inhibition of jack bean activity by 2,5-dichloro-1,4-benzoquinone (DCBQ) was studied in phosphate buffer, pH 7.0. It was found that DCBQ acted as a strong, time and concentration dependent inactivator of urease. Under the experimental conditions obeyed the terms of pseudo-first-order reaction, urease was totally inactivated. Application of Wilson-Kitz method proved that the urease-DCBQ interaction followed a simple bimolecular process and the presence of intermediate complex was undetectable. The determined second order rate constant of the inactivation was 0.053 (μM min)-1. Thiols such as l-cysteine, glutathione and dithiothreitol (DTT) protected urease from inhibition by DCBQ but DCBQ-modified urease did not regain its activity after DTT application. The thiol protective studies indicated an essential role of urease thiol(s) in the inhibition. The irreversibility of the inactivation showed that the process was a result of a direct modification of urease thiol(s) by DCBQ (DCBQ chlorine(s) substitution). The decomposition of DCBQ in aqueous solution at natural light exposure was monitored by visible spectrophotometry, determination of the total reducing capacity (Folin-Ciocalteu method) and DPPH (2,2-diphenyl-1-picrylhydrazyl) radical scavenging ability. The DCBQ conversion resulted in a decrease of the inhibition power and was well correlated with the increase of the total reducing capacity and DPPH scavenging ability. These findings were attributed to DCBQ transformation by photolysis and the hydrolysis effect was found to be negligible.
Źródło:
Acta Biochimica Polonica; 2011, 58, 4; 627-633
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nośność prefabrykowanych rur betonowych
Capacity of precast concrete pipes
Autorzy:
Kmita, A.
Wróblewski, R.
Powiązania:
https://bibliotekanauki.pl/articles/163069.pdf
Data publikacji:
2011
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
rura żelbetowa
rura prefabrykowana
nośność
metoda obliczeń
reinforced concrete pipe
prefabricated pipe
load bearing capacity
calculation method
Opis:
Z uwagi na obserwowane duże rozbieżności pomiędzy wynikami badań doświadczalnych a wynikami obliczeń przedstawiono propozycję metody obliczania nośności rur wykonywanych z betonu niezbrojonego. W metodzie połączono badania laboratoryjne rur z dostępnymi metodami analitycznymi. Umożliwia to bardziej kompleksową ocenę nośności.
Significant discrepancies between experimental and computational results of pure concrete pipes are observed. Due to that fact a load bearing capacity calculation method is presented. This method combines experimental verification of the pipe type with available analytical methods. In a result more realistic capacity evaluation is achieved.
Źródło:
Przegląd Budowlany; 2011, R. 82, nr 6, 6; 83-85
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena nośności pali na podstawie badań sondą statyczną CPT
Evaluation of the bearing capacity of piles based on CPT test
Autorzy:
Konderla, H.
Powiązania:
https://bibliotekanauki.pl/articles/350490.pdf
Data publikacji:
2011
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
nośność pali
sondowanie statyczne CPT
metoda Philipponnat
metoda Energopolu
bearing capacity of piles
CPT test
Philipponnat's method
Energopol's method
Opis:
W artykule przedstawiono możliwości oceny nośności pali na podstawie wyników badań sondą statyczną CPT. Omówiono metodę pośrednią wyznaczania nośności opartą na polskiej normie palowej. Opisano szczegółowo dwie metody bezpośrednie, które zostały wykorzystane w przykładzie liczbowym. Zamieszczono wyniki sondowania CPT wraz z interpretacją. W przykładzie liczbowym porównano wyniki obliczeń nośności fundamentu palowego za pomocą rozważanych metod.
The possibilities evaluation of the bearing capacity of piles based on the static penetration test has been presentation in the paper. The indirect method of the bearing capacity calculate based on the Polish pile norm was discussed. Two direct methods were described in detail and used in the numerical example. One example of CPT result with their interpretation was included in the paper. The results calculation of the bearing capacity pile foundation were compared for considered methods.
Źródło:
Górnictwo i Geoinżynieria; 2011, 35, 2; 367-374
1732-6702
Pojawia się w:
Górnictwo i Geoinżynieria
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza porównawcza nośności wyznaczanych na podstawie norm PN-B/PN-E i PN-EN oraz badań w skali rzeczywistej słupów kratowych linii elektroenergetycznych
Comparative analysis of load-bearing capacities determined on the basis of PN-B/PN-E and PN-EN standards, and full-scale testing of latticed electricity transmission towers
Autorzy:
Lewiński, P.
Czyż, R.
Wojciechowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/163615.pdf
Data publikacji:
2012
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
słup kratowy
linia elektroenergetyczna
specyfikacja techniczna
nośność
ugięcie
zniszczenie
badanie doświadczalne
wyniki badań
obliczanie
metoda elementów skończonych
lattice pole
electricity power line
technical specification
load-bearing capacity
deflection
destruction
experimental research
test results
calculation
finite element method
Opis:
Badania słupów obejmowały: dobór ich geometrii, obciążenia próbne słupów z pomiarami wielkości fizycznych oraz analizę ugięć i zachowania się słupów aż do zniszczenia. W artykule porównano wyniki analityczne wyznaczane na podstawie norm PN-B / PN-E i PN-EN z uzyskanymi w badaniach niszczących, formułując odpowiednie wnioski.
Testing of the towers included selection of their geometry, trial loading with measurements of physical parameters, and analysis of deflections and the behaviour of the towers up to destruction. The authors compare the analytical results determined on the basis of the PN-B/PN-E and PN-EN standards with those obtained in destruction testing, and draw appropriate conclusions.
Źródło:
Przegląd Budowlany; 2012, R. 83, nr 5, 5; 100-103
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Definition of alloy substitute thermal capacity using the simple macrosegregation models
Autorzy:
Mochnacki, B.
Powiązania:
https://bibliotekanauki.pl/articles/380456.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
technologia informatyczna
przemysł odlewniczy
proces krzepnięcia
zastępcza pojemność cieplna
metody numeryczne
information technology
foundry industry
solidification process
one domain method
substitute thermal capacity
numerical methods
Opis:
Mathematical description of alloys solidification in a macro scale can be formulated using the one domain method (fixed domain approach). The energy equation corresponding to this model contains the parameter called a substitute thermal capacity (STC). The analytical form of STC results from the assumption concerning the course of the function fs = fs (T) describing the changes of solid state volumetric fraction and the temperature at the point considered. Between border temperatures Ts , Tl the function fs changes from 1 to 0. In this paper the volumetric fraction fs (more precisely fl = 1- fs) is found using the simple models of macrosegregation (the lever arm rule, the Scheil model). In this way one obtains the formulas determining the course of STC resulting from the certain physical considerations and this approach seems to be closer to the real course of thermal processes proceeding in domain of solidifying alloy.
Źródło:
Archives of Foundry Engineering; 2012, 12, 4; 113-116
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Method of a choice of parameters of the air cooling machine of a cascade pressure exchange
Metod vybora parametrov vozdushnojj kholodilhojj mashiny kaskadnogo obmena davleniem
Autorzy:
Krajniuk, A.
Starcheous, Y.
Danileychenko, A.
Bryantsev, M.
Powiązania:
https://bibliotekanauki.pl/articles/791920.pdf
Data publikacji:
2012
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
cascade pressure exchanger
mass exchange
air cooling machine
refrigerating capacity
mechanical energy
thermal energy
algorithm
calculation method
calculation
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2012, 12, 4
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Statistical relationship between methane desorption rate index and coalbed methane content on the basis of coal mine "Zofiówka" measurements
Zależność statystyczna pomiędzy wartościami wskaźnika intensywności desorpcji a metanonośnością na podstawie pomiarów wykonanych w kopalni "Zofiówka"
Autorzy:
Wierzbicki, M.
Powiązania:
https://bibliotekanauki.pl/articles/348653.pdf
Data publikacji:
2012
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
metanonośność
desorpcja metanu
zagrożenie metanowe
methane capacity
desorbometric method
methane danger
Opis:
This paper presents the results of coalbed methane content (Mn) and methane desorption rate index (dp) in the mine "Zofiówka". These results were used to assess the quality of coalbed methane content using the indirect method - desorbometric method. Application of the Langmuir equation to describe the relation Mn = f (dp) allows the determination of methane content with the uncertainty of the measurement similar to that obtained in the method of direct hole.
W pracy przedstawiono wyniki badania metanonośności (Mn) pokładów węgla oraz wskaźnika intensywności desorpcji (dp) w kopalni "Zofiówka". Wyniki te zostały wykorzystane do oceny jakości wyznaczania metanonośności metodą pośrednią-desorbometryczną. Zastosowanie równania Langmuira do opisu zależności Mn = f (dp) pozwala na oznaczanie metanonośności z niepewnością zbliżoną do niepewności pomiarowej uzyskiwanej w metodzie bezpośredniej otworowej.
Źródło:
AGH Journal of Mining and Geoengineering; 2012, 36, 3; 395-404
1732-6702
Pojawia się w:
AGH Journal of Mining and Geoengineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The analysis of estimation the pile bearing capacity on the CPTU
Analiza nośności pali ustalonych na podstawie wyników badań sondą statyczną CPTU
Autorzy:
Orabczuk, Ł.
Bagińska, I.
Powiązania:
https://bibliotekanauki.pl/articles/348671.pdf
Data publikacji:
2012
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
nośność pala
projektowanie pali gruntowych
metody oszacowania nośności pali
piles bearing capacity
soil piles designing
method for estimating pile bearing capacity
Opis:
The paper presents estimation of the pile bearing capacity based on actual findings of the CPTU static probe. The calculations were performed by the methods of Adamczyk, Gwizdała, Energopol, Wiłun, Gianeselle i Bustamante and Philipponant, Kłos. Design methods were divided into four groups in terms of their suitability for specific pile manufacture technologies. For the estimation of bearing capacity a pile dimension was assumed, and for the particular capacity a length was sought, at which the capacity would be ensured. All results were compared to the method derived from Eurocode 7.
W pracy przedstawiono oszacowania nośności pala wciskanego na podstawie wyników badań sondą statyczną CPTU. Obliczenia analityczne wykonano dla rzeczywistych warunków gruntowych w miejscu planowanego posadowienia obiektu inżynierskiego. W pracy przedstawiono zarejestrowane podczas sondowania statycznego pomiary oporu wciskania na stożku q/c, oporu tarcia na tulei ciernej f/s i ciśnienia porowego u/2 oraz wyznaczony profil geologiczny wg klasyfikacji normowej PN-B-04452:2002. Oszacowanie nośności wykonano ośmioma metodami: Adamczyka, Gwizdały, Energopolu, Wiłuna, Gianesellego i Bustamantego oraz Philipponanta, Kłosa, a także normowymi PN-83/B-02482 i PN-EN 1997-2:2009 (Eurokod 7).
Źródło:
AGH Journal of Mining and Geoengineering; 2012, 36, 2; 247-258
1732-6702
Pojawia się w:
AGH Journal of Mining and Geoengineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of viscosity and compressibility of aerated oil on determination of volumetric losses in a variable capacity piston pump
Autorzy:
Koralewski, J.
Powiązania:
https://bibliotekanauki.pl/articles/260047.pdf
Data publikacji:
2013
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
hydrostatic drive
variable capacity displacement pump
liquid aeration
method of determining the degree of liquid aeration
Opis:
Modulus B of the liquid volume elasticity of non-aerated and aerated oil is defined in the paper as relation to the indicated increase of pressure in the pump working chambers, with the change of oil temperature and degree of aeration. In evaluation of the losses due to oil compressibility in a variable capacity displacement pump, the volume of compressed liquid at each pump setting is taken into account. Volumetric losses have been divided into leakage losses in the pump chambers and losses due to liquid compressibility. The need of accounting for only the leakage losses for pump evaluation is pointed out.
Źródło:
Polish Maritime Research; 2013, 4; 3-17
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Laboratory experimental analysis on encapsulated stone column
Autorzy:
Tandel, Y. K.
Solanki, C. H.
Desai, A. K.
Powiązania:
https://bibliotekanauki.pl/articles/230339.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
kolumna kamienna
hermetyzacja
geosyntetyk
eksperyment
metoda elementów skończonych
nośność
odkształcenie promieniowe
kształt zdeformowany
stone column
encapsulation
geosynthetic
experiment
finite element method
load carrying capacity
radial deformation
deformed shape
Opis:
The application of stone column technique for improvement of soft soils has attracted a considerable attention during the last decade. However, in a very soft soil, the stone columns undergo excessive bulging, because of very low lateral confinement pressure provided by the surrounding soil. The performance of stone column can be improved by the encapsulation of stone column by geosynthetic, which acts to provide additional confinement to columns, preventing excessive bulging and column failure. In the present study, a detailed experimental study on behavior of single column is carried out by varying parameters like diameter of the stone column, length of stone column, length of geosynthetic encapsulation and stiffness of encapsulation material. In addition, finite-element analyses have been performed to access the radial deformation of stone column. The results indicate a remarkable increase in load carrying capacity due to encapsulation. The load carrying capacity of column depends very much upon the diameter of the stone column and stiffness of encapsulation material. The results show that partial encapsulation over top half of the column and fully encapsulated floating column of half the length of clay bed thickness give lower load carrying capacity than fully encapsulated end bearing column. In addition, radial deformation of stone column decreases with increasing stiffness of encapsulation material.
Źródło:
Archives of Civil Engineering; 2013, 59, 3; 359-379
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Method of determining the degree of liquid aeration in a variable capacity displacement pump
Autorzy:
Paszota, Z.
Powiązania:
https://bibliotekanauki.pl/articles/258874.pdf
Data publikacji:
2013
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
hydrostatic drive
variable capacity displacement pump
liquid aeration
method of determining the degree of liquid aeration
Opis:
The Author concludes, that there is a possibility of determining a concrete value of the liquid aeration coefficient ε during the pump operation by finding such value of ε with which the increase ΔMPm|ΔpPi = pn, qPgv of torque of mechanical losses is proportional to the indicated torque MPi|ΔpPi = pn, qPgv determined with a fixed value ΔpPi = cte of increase of pressure in the pump working chambers. The fixed value ΔpPi assumed in searching the liquid aeration coefficient ε equals to the nominal pump operation pressure pn (ΔpPi = cte = pn ). The increase ΔMPm|ΔpPi = pn, qPgv of torque of mechanical losses with a fixed value of ΔpPi (ΔpPi = cte) is proportional to the pump geometrical working capacity qPgv , therefore: only with taking into account the aeration coefficient ε of liquid displaced by the pump the relation ΔMPm|ΔpPi = pn, qPgv ~ qPgv can be obtained from tests. The method, proposed by the Author, of determining the working liquid aeration coefficient ε, is presented in this paper and has been practically applied for the first time by Jan Koralewski in his investigations of the influence of viscosity and compressibility of aerated hydraulic oil on volumetric and mechanical losses in a pump of HYDROMATIK A7V.58.1.R.P.F.00 type [8, 9].
Źródło:
Polish Maritime Research; 2013, 3; 3-13
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reliability assessment of bearing capacity of layered soils using High Dimensional Model Representation (HDMR)
Autorzy:
Suska, M.
Puła, W.
Powiązania:
https://bibliotekanauki.pl/articles/178931.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
nośność podłoża
metoda HDMR
bearing capacity
HDMR method
Opis:
HDMR (High Dimensional Model Representation) is a relatively new method that is used to form response surface based on results obtained through laboratory experiments or through numerical calculations. So far the method has been used mainly in chemistry, although a few studies conducted in recent years show that it can be considered a useful tool in soil mechanics and foundation engineering. The subject matter of this paper is the application of HDMR method to reliability assessment of bearing capacity of layered soils. Madej’s method, widely recognized and used by Polish engineers, is applied to conduct the calculations. In the analysed case bearing capacity is not expressed by means of an explicit formula. To fit the approximate functions of bearing capacity, its values are calculated on a grid of points equally spread on ranges of variables. Finding the relation between input and output data is conducted by means of assessing each variable’s influence on response’s mean value within a given scope. Approximate functions have been used to calculate reliability indices by means of FORM, SORM and Monte Carlo methods.
Źródło:
Studia Geotechnica et Mechanica; 2013, 35, 1; 233-243
0137-6365
2083-831X
Pojawia się w:
Studia Geotechnica et Mechanica
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies