Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "building failure" wg kryterium: Temat


Tytuł:
Monitoring of a historic sacral building on an example Basilica St. Nicholas in Gdańsk
Autorzy:
Majewski, Tomasz
Niedostatkiewicz, Maciej
Powiązania:
https://bibliotekanauki.pl/articles/24201300.pdf
Data publikacji:
2023
Wydawca:
Centrum Rzeczoznawstwa Budowlanego Sp. z o.o.
Tematy:
object monitoring
construction diagnostics
monument
sacral building
failure of brick building
failure of monument
Basilica of St. Nicholas in Gdańsk
monitorowanie obiektów
diagnostyka konstrukcji
pomnik
budynek sakralny
awaria budynku ceglanego
awaria pomnika
Bazylika św. Mikołaja w Gdańsku
Opis:
The paper describes the case of monitoring the technical condition of a historic sacral building after a failure and during renovation works. In order to monitor the condition of the building, safely conduct diagnostic work, identify the causes of failures and safely carry out renovation works, a detailed Facility Monitoring Program has been developed, which has been implemented, is operational and is a source of valuable data used to assess the current condition of the facility.
Źródło:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych; 2023, 3; 30--42
2450-1859
2450-8721
Pojawia się w:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza pracy balustrady zamocowanej w zawilgoconej konstrukcji murowej budynków z początku lat 80. XX w.
Analysis of the work of the fixed railing in a damp structure masonry of buildings from the beginning of the years 1980s
Autorzy:
Ksit, Barbara
Powiązania:
https://bibliotekanauki.pl/articles/2160677.pdf
Data publikacji:
2022
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
balustrada
zamocowanie
loggia
konstrukcja murowa
zawilgocenie
awaria
budynek wielkopłytowy
błąd wykonawstwa
błąd projektowania
model obliczeniowy
analiza statyczna
balustrade
fastening
masonry structure
moisture content
failure
large-panel building
execution fault
design fault
calculation model
static analysis
Opis:
Materiały budowlane absorbują kapilarnie wilgoć, gdy mają z nią bezpośrednią styczność. W artykule przedstawiono analizę statyczną mocowania zabezpieczających barier w uszkodzonych loggiach budynków 5-kondygnacyjnych, wykonanych w technologii uprzemysłowionej z elementami technologii tradycyjnej, zrealizowanych w latach osiemdziesiątych XX w. Źle wyprofilowane zabezpieczenie połączenia elementów stalowych balustrad z konstrukcją murową wielokrotnie jest głównym transporterem wody w strukturę muru, a co za tym idzie powoduje pogorszenie parametrów wytrzymałościowych i statycznych zaprojektowanych połączeń. W analizie wytrzymałościowej przedstawiono wykorzystanie programów MES oraz role poprawnie przeprowadzonych badań in situ.
Building materials absorb moisture by capillary action when in direct contact with it. The article presents a static analysis of fastening of protective barriers in damaged logs of 5-storey buildings, made in industrialized technology with elements of traditional technology, implemented in the 1980s. Badly profiled protection of the connection of steel railings with the masonry structure, many times it is the main transport of water into the wall structure and thus causes deterioration of the strength and static parameters of the designed connections. The use of MES programs and the roles of correctly conducted In situ tests were presented in the strength analysis.
Źródło:
Przegląd Budowlany; 2022, 93, 7-8; 107--109
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bezpieczeństwo prac budowlanych w pobliżu podziemnych sieci elektroenergetycznych
Safety of construction works in the vicinity of underground power networks
Autorzy:
Ciszewski, Jan
Powiązania:
https://bibliotekanauki.pl/articles/2202737.pdf
Data publikacji:
2022
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
roboty budowlane
bezpieczeństwo
budowa
sieć elektroenergetyczna
sieć podziemna
uszkodzenie
wypadek przy pracy
zdarzenie potencjalnie wypadkowe
przyczyna
building works
safety
construction
electric power network
underground network
failure
work accident
near miss
cause
Opis:
W artykule przedstawiono jedno z większych wyzwań, jakie czeka na wykonawców, podczas realizacji większości prac budowlanych - praca w pobliżu podziemnych sieci elektroenergetycznych. Uszkodzenia sieci elektroenergetycznych wiążą się z ogromnym ryzykiem. Zdarza się, że są one przyczyną poważnych wypadków, w tym również ciężkich, zbiorowych i śmiertelnych. Statystyki zaraportowanych zdarzeń potencjalnie wypadkowych w latach 2015-2021 w badanym przedsiębiorstwie budowlanym pokazują, że zdarzenia, związane z uszkodzeniami podziemnych sieci elektrycznych, stanowią znaczący procent wszystkich raportowanych zdarzeń.
The article presents one of the major challenges that await contractors during the implementation of most construction works - work in the vicinity of underground power grids. Damage to power grids carries enormous risks. It happens that they cause serious accidents, including serious, group and fatal ones. Statistics of reported near misses in the years 2015-2021 in the surveyed construction company show that events related to damage to underground electrical networks constitute a significant percentage of all reported events.
Źródło:
Przegląd Budowlany; 2022, 93, 9-10; 94--97
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zabytkowe budynki w stanie awaryjnym
Historical buildings in an emergency technical condition
Autorzy:
Hulimka, Jacek
Powiązania:
https://bibliotekanauki.pl/articles/2081881.pdf
Data publikacji:
2022
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
obiekt zabytkowy
stan techniczny
ekspertyza
ruina
przykład
ryzyko awarii
historic building
technical condition
expertise
ruin
example
failure risk
Opis:
Ideą artykułu jest pytanie - czy zabytkowy obiekt budowlany pozostaje nim niezależnie od stanu technicznego, czy też pewien stopień zrujnowania uprawnia do starania się o wykreślenie go z rejestru zabytków? Pokrótce odniesiono się do stanu prawnego uznania obiektów budowlanych za zabytki, a następnie przedstawiono wybrane przykłady budynków zabytkowych, które z czasem uległy daleko posuniętej destrukcji. Przedstawiono tu, ilustrując fotografiami, podstawowe uszkodzenia elementów konstrukcyjnych i wykończeniowych, a następnie opisano dalsze losy przedmiotowych obiektów. Zwrócono też uwagę na problem odpowiedzialności za obiekt zagrożony katastrofą budowlaną, a niemożliwy do likwidacji.
The main idea of the article is whether a historical building remains a monument regardless of the technical condition or is there a certain degree of destruction that entitles its removal from the register of monuments? The legal status of recognizing buildings as monuments has been briefly referred, then selected examples of historical buildings that have been badly damaged over time were presented. The basic damages to construction and finishing elements are presented and illustrated on photographs, then the further fate of the objects in question is described. The problem of the responsibility for the facility at risk of a construction disaster that cannot be demolished has also been highlighted.
Źródło:
Przegląd Budowlany; 2022, 93, 3-4; 28--33
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Najważniejsze problemy poprawy projektowania elementów i obiektów budowlanych
The most important problems of design improvement elements and construction objects
Autorzy:
Runkiewicz, Leonard
Sieczkowski, Jan
Powiązania:
https://bibliotekanauki.pl/articles/1848323.pdf
Data publikacji:
2021
Wydawca:
PWB MEDIA Zdziebłowski
Tematy:
zagrożenie
awaria
katastrofa budowlana
przyczyna
błąd projektowania
safety assessment
failure risk
building damage
reason
design fault
Opis:
W artykule przedstawiono szacunkowe zestawienia wyników analiz zagrożeń, awarii i katastrof, jakie wystąpiły na terenie Polski w latach 1962–2019. Wyniki zestawiono w zależności od charakteru obiektów, rodzaju uszkodzeń lub zniszczeń oraz rodzaju materiałów. Wskazano również najbardziej powszechne błędy projektowe wpływające na zagrożenia, awarie i katastrofy oraz wymieniono elementy, których powinna dotyczyć poprawa projektowania. Wnioski z analiz powinny stanowić podstawy do innowacyjnych rozwiązań w pracach badawczo-wdrożeniowych.
The paper presents the estimated results of the analyzes risk of failure and building damage that occurred in Poland in the years 1962-2019. The results were compiled depending on the nature of the objects, the type of damage or destruction and the type of materials. The most common design errors affecting failures and disasters were also indicated, and elements that should be improved in design were listed. Conclusions from the analyzes should constitute the basis for innovative solutions in research and implementation works.
Źródło:
Builder; 2021, 25, 5; 21-24
1896-0642
Pojawia się w:
Builder
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Najważniejsze zagadnienia związane z poprawą wykonawstwa elementów i obiektów budowlanych
The most important issues related to the improvement of the execution of elements and erection of buildings
Autorzy:
Runkiewicz, Leonard
Runkiewicz, Maciej
Sieczkowski, Jan
Powiązania:
https://bibliotekanauki.pl/articles/1860613.pdf
Data publikacji:
2021
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
obiekt budowlany
katastrofa budowlana
awaria budowlana
zagrożenie awarią
przyczyna awarii
błąd człowieka
technologia budowlana
stan techniczny
błąd wykonawstwa
błąd projektowania
baza danych
Instytut Techniki Budowlanej
building object
building disaster
building failure
safety hazard
failure cause
human error
construction technology
technical condition
execution error
design error
data base
Building Research Institute
Opis:
W artykule przedstawiono szacunkowe zestawienia wyników analiz zagrożeń, awarii i katastrof, jakie wystąpiły na terenie Polski w ostatnich 50 latach. Wyniki zestawiono w zależności od charakteru obiektów, technologii wykonania, rodzaju uszkodzeń lub zniszczeń, rodzaju elementów i ich funkcji w konstrukcjach oraz rodzaju materiałów. Wskazano również przyczyny techniczne powstawania zagrożeń, awarii i katastrof wynikające z błędów projektowych i wykonawstwa. Wnioski z analiz powinny stanowić podstawy do innowacyjnych rozwiązań w pracach badawczo-wdrożeniowych.
The paper presents the estimated results of the analyzes risk of failure and building damage that occurred in Poland in the last 50 years. The results were compiled depending on the nature of the objects, technology of execution, the type of damage or destruction, the type elements and their functions in the structures and the type of materials. The technical reasons of risk of failure and building damage resulting from design and execution errors were also indicated. Conclusions from the analyzes should constitute the basis for innovative solutions in research and implementation works.
Źródło:
Przegląd Budowlany; 2021, 92, 4; 11-17
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przyczyny powstawania zagrożeń, awarii i katastrof obiektów budowlanych
Reasons for threats, failures and catastrophes of construction objects
Autorzy:
Runkiewicz, Leonard
Powiązania:
https://bibliotekanauki.pl/articles/161667.pdf
Data publikacji:
2020
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
obiekt budowlany
ryzyko awarii
awaria
katastrofa
błąd projektowania
błąd wykonawstwa
błąd eksploatacji
building object
failure risk
structural failure
collapse
design error
execution fault
incorrect usage
Opis:
W artykule przedstawiono przyczyny powstawania zagrożeń, awarii i katastrof obiektów budowlanych. Są to generalnie czynniki losowe niezależne od uczestników procesów budowlanych oraz czynniki zależne od błędów popełnionych przez uczestników procesów budowlanych i eksploatacyjnych.
The article presents the causes of threats, failures and building catastrophes. These are generally random factors independent of participants in building processes. Factors depending on the mistakes made by participants in building and operating processes has also been shown.
Źródło:
Przegląd Budowlany; 2020, 91, 5; 15-19
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wzmocnienie konstrukcji stropu budynku wysokościowego
Strengthening of ceiling structure in the multi-storey building
Autorzy:
Rowiński, Sławomir
Dudkiewicz, Jacek
Ignatowicz, Rajmund
Powiązania:
https://bibliotekanauki.pl/articles/129241.pdf
Data publikacji:
2020
Wydawca:
PWB MEDIA Zdziebłowski
Tematy:
awaria
strop żelbetowy
budynek wysokościowy
błąd projektowy
błąd wykonawstwa
wzmocnienie konstrukcji
failure
reinforced concrete ceiling
multi-storey building
design mistake
executive mistake
structure strengthening
Opis:
Postęp cywilizacyjny miast generuje potrzebę zwiększania komfortu społeczeństwa w każdej dziedzinie jego działalności, między innymi handlu, komunikacji, jak i warunków mieszkania. To z kolei tworzy potrzebę wznoszenia budynków wielokondygnacyjnych oraz potrzebę bardziej efektywnego wykorzystywania parametrów wytrzymałościowych stosowanych materiałów. W tym ciągłym procesie pokonywane są kolejne bariery techniczne i technologiczne, które do tej pory mogły ograniczać rozwój budownictwa. Jednak poszukiwanie nowych rozwiązań, a następnie ich wdrażanie, może doprowadzić do zmniejszenia bezpieczeństwa i stanów awaryjnych konstrukcji. W artykule przedstawiono przykład awarii stropu żelbetowego budynku wysokościowego spowodowanej zarówno błędami projektowymi, jak i wykonawczymi. Zaprezentowano rozwiązania wzmocnienia konstrukcji.
The progress of civilization of cities generates need to increase the comfort of society in every field of its activities, including trade, transport, and living conditions. This in turn creates the need of building multi-storey buildings and the need of more efficient using of the strength parameters of the materials. In this continuous process are overcome the technical and technological barriers, which until now could limit the development of the construction industry. However, the searching for new solutions and their implementation can lead to reducing the safety of constructions and failure conditions in structures. The paper is an example of failure of reinforced concrete ceiling in the multi-storey buildings due to design and executive mistakes. In this paper authors presented solutions of strengthening the structure.
Źródło:
Builder; 2020, 24, 4; 61-63
1896-0642
Pojawia się w:
Builder
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Najczęściej popełniane błędy w projektowaniu konstrukcji budowlanych
The most common mistakes made in the design of building structures
Autorzy:
Runkiewicz, Leonard
Sieczkowski, Jan
Powiązania:
https://bibliotekanauki.pl/articles/163315.pdf
Data publikacji:
2019
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
konstrukcja budowlana
projektowanie
posadowienie budynku
awaria
katastrofa
analiza zagrożeń
building construction
designing
building foundation
structural failure
disaster
threats analysis
Opis:
Każda działalność człowieka, w tym także związana z budownictwem, obarczona jest możliwością popełnienia błędów. Awarie i katastrofy budowlane występowały „od zawsze”, tzn. od początku działalności budowlanej człowieka i niekiedy pociągały za sobą wiele ofiar śmiertelnych i duże straty materialne. W artykule omówiono ogólne zasady projektowania konstrukcji, przedstawiono wnioski z wieloletnich analiz zagrożeń, awarii i katastrof budowlanych oraz przyczyny techniczne ich powstawania, a także wybrane, często popełniane błędy projektowe.
Every human activity, including those related to construction, is burdened with the possibility of making mistakes. Construction failures and disasters have always occurred, i.e. from the beginning of human construction, and sometimes resulted in many fatalities and large material losses. The article discusses general principles of structural design and presents conclusions from many years of analysis of hazards, breakdowns and construction disasters, technical reasons for their formation, as well as selected, often made design errors.
Źródło:
Przegląd Budowlany; 2019, 90, 5; 18-24
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ występujących zagrożeń i awarii budowlanych na potrzeby rewitalizacji i rekonstrukcji obiektów budowlanych
The influence of risks and failures on the needs for revitalization and reconstruction of building constructions
Autorzy:
Runkiewicz, Leonard
Sieczkowski, Jan
Powiązania:
https://bibliotekanauki.pl/articles/161037.pdf
Data publikacji:
2019
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
obiekt budowlany
awaria budowlana
zagrożenie
katastrofa
rekonstrukcja
rewitalizacja
przykład
building object
construction failure
danger
disaster
reconstruction
revitalization
example
Opis:
Uszkodzenia, awarie oraz katastrofy budowlane są analizowane, a wnioski z tych prac wprowadzane do praktyki budowlanej. W artykule przedstawiono wyniki analiz wieloletnich zbiorów danych o awariach i katastrofach budowlanych oraz wykazy przyczyn złego projektowania i wykonawstwa.
Damage and structural failures are analyzed and conclusions from these works are introduced to the construction practice. The paper presents the results of analyzes of long-term datasets of data on damage and structural failures as well as lists of the causes of poor design and execution.
Źródło:
Przegląd Budowlany; 2019, 90, 9; 30-35
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Awarie w budynkach spowodowane błędnymi rozwiązaniami konstrukcyjnymi
Failures in building caused by incorrect construction solutions
Autorzy:
Wesołowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/161170.pdf
Data publikacji:
2017
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
awaria budynku
spękanie
przyczyna awarii
rozwiązanie konstrukcyjne
błąd projektowania
building failure
cracking
failure cause
structural solution
design error
Opis:
W pracy przedstawiono stany awaryjne dwóch budynków: mieszkalno-usługowego oraz mieszkalnego, w których doszło do niekontrolowanych zarysowań ścian wewnętrznych, skutkujących utrudnieniami eksploatacyjnymi dla użytkowników mieszkań. Przeprowadzona analiza wykazała, że w obydwu przypadkach doszło do poważnych błędów na etapie projektowania obiektów, gdzie dość pobieżnie i bezrefleksyjnie projektanci podeszli do analizy stanu granicznego użytkowalności w aspekcie ugięć stropów.
This thesis presents the emergency situations of two buildings: residential & commercial, and residential, where uncontrolled scratches of internal walls occurred, resulting in operational difficulties for the users of apartments. The analysis showed, that in both cases, there were serious errors in the design of the objects, where the designers in a sketchy and unreflective way, approached the serviceability limit state analysis in the aspect of deflection of the ceiling.
Źródło:
Przegląd Budowlany; 2017, 88, 6; 46-50
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Failure and deformation of full-scale light frame poplar and spruce walls under vertical compression and shear load
Autorzy:
Pasztory, Z.
Rebek-Nagy, P.
Powiązania:
https://bibliotekanauki.pl/articles/52315.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Drewna
Tematy:
failure
deformation
light frame building
poplar
spruce
vertical compression
wall compression test
shear load
wall shear test
building material
mechanical property
Źródło:
Drewno. Prace Naukowe. Doniesienia. Komunikaty; 2017, 60, 200
1644-3985
Pojawia się w:
Drewno. Prace Naukowe. Doniesienia. Komunikaty
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Awaria budynku zabytkowego w wyniku realizacji prac budowlanych w sąsiedztwie
The failure of the listed building as result of the realization of construction work in the neighbourhood
Autorzy:
Błaszczyński, T.
Powiązania:
https://bibliotekanauki.pl/articles/390099.pdf
Data publikacji:
2016
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
budynek zabytkowy
awaria
stan awaryjny
prace budowlane
listed building
failure
failure state
construction work
Opis:
W związku z projektowaną budową wielofunkcyjnego budynku biurowo-usługowego w Poznaniu, a także w związku z przewidywaną modernizacją technicznej infrastruktury podziemnej, powinna zachodzić potrzeba inwentaryzacji i oceny stanu technicznego istniejących obiektów sąsiednich. Także zgodnie z wymogami sformułowanymi w decyzji o warunkach zabudowy oraz zgodnie z uwagami zawartymi we wcześniejszych ekspertyzach, powinno się wykonać te prace. Inwentaryzacja i ocena stanu technicznego istniejących obiektów sąsiednich powinna być wykonana pod kątem wpływu budowy na nie i przeciwdziałania ewentualnym skutkom związanym z realizacją projektowanych robót w sąsiedztwie. Niestety inwestor takich prac nie podjął, a realizowane prace doprowadziły do stanu awaryjnego w analizowanym budynku zabytkowym.
In connection with new designed construction of retail-office building in Poznań, and also in connection with the foreseen modernization of the technical underground infrastructure, it should happened the necessity of inventory and the estimation of the technical state of existing neighbouring objects. Also formally with formulated in the decision land development and in accordance with the references contained in earlier expertises, these works should be execute. The inventory and the estimation of the technical state of existing neighbouring objects should be performed in the connection with the influence of new construction in the vicinity on these objects and with counteractions to possible results connected with the realization of designed works in the neighbourhood. Unfortunately the investor did not undertake such works, and realized works brought to the failure state in analysed listed building.
Źródło:
Budownictwo i Architektura; 2016, 15, 2; 79-86
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ korozji na zagrożenia i awaryjność obiektów budowlanych
Impact of corrosion on dangers and fault rate in building structures
Autorzy:
Runkiewicz, L.
Powiązania:
https://bibliotekanauki.pl/articles/163573.pdf
Data publikacji:
2016
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
konstrukcja budowlana
oddziaływanie środowiska
korozja
bezpieczeństwo konstrukcji
trwałość
niezawodność
awaryjność
building structure
environment impact
corrosion
structure safety
durability
reliability
failure rate
Opis:
Obiekty budowlane w czasie eksploatacji narażone są często na niekorzystne działanie środowiska i korozji. Procesy niekorzystnego działania korozji na tworzywa konstrukcyjne wpływają na bezpieczeństwo, niezawodność i użyteczność konstrukcji. Obniżają one też trwałość konstrukcji tych obiektów. W zależności od rodzaju konstrukcji oraz warunków eksploatacji występują bezpośrednie i pośrednie oddziaływania korozyjne. Powodują one duże zniszczenia konstrukcji, a nawet wywołują ich awarie i katastrofy.
Buildings, during use, are often exposed to a number of detrimental environmental factors and corrosion. The detrimental impact corrosion has on construction materials has an influence on safety, reliability and usability of the given structure. It also diminishes the structural durability of the said buildings. Depending on the type of the structure, and on the array of the conditions of use, direct and indirect corrosion factors emerge. They lead to major damage of the structure, failures and disasters.
Źródło:
Przegląd Budowlany; 2016, R. 87, nr 12, 12; 32-37
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyparcie ścianki szczelnej na budowie jazu w nurcie rzeki
Failure of sheet piling in course the building of diversion weir in a river midstream
Autorzy:
Parylak, K.
Antoniszyn, G.
Powiązania:
https://bibliotekanauki.pl/articles/40107.pdf
Data publikacji:
2016
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
Nysa
rzeka Nysa Klodzka
budowle hydrotechniczne
budowle pietrzace
jazy
scianka szczelna
badania geotechniczne
rozpoznanie geotechniczne
przebicie hydrauliczne
awarie budowlane
Nysa town
Nysa Klodzka River
hydrotechnical structure
dam building
weir
geotechnical research
geotechnical investigation
internal erosion
construction failure
Opis:
Na rzece Nysie Kłodzkiej w mieście Nysie zaprojektowano trzyprzęsłowy jaz piętrzący wodę na potrzeby energetyczne. Dokumentacja projektowa nie zawierała przewidzianego Eurokodem 7 projektu geotechnicznego, a w tym badań podłoża gruntowego, spełniających wymagania III kategorii geotechnicznej. Wykonano jedynie niewystarczające wiercenia geologiczne i sondowania dynamiczne. W konsekwencji do projektu przyjęto niezgodny z rzeczywistością układ warstw i parametry geotechniczne niemogące być podstawą do poprawnego posadowienia i wykonania jazu. Nie wykazano także, że pod dnem szerokoprzestrzennego wykopu fundamentowego zamiast podanych w dokumentacji gruntów spoistych w stanie twardoplastycznym występowały tylko ich nieliczne przewarstwienia w sufozyjnych piaskach drobnych i pylastych o miąższości ponad 4,5 m. Przyjęcie do projektowania tych nieprawdziwych cech podłoża spowodowało, że ściankę szczelną zakończono w piaskach zaledwie 2,5 m poniżej poziomu posadowienia jazu. W wykonywanym początkowo w żwirach, a następnie w warstwie gruntów spoistych wykopie na głębokości 7 m powstało przebicie hydrauliczne. Nastąpiło gwałtowne wyparcie dolnego końca ścianki, jej deformacja, a wykop zapełnił się sufozyjnym gruntem. Spowodowało to także rozluźnienie podłoża pod zaprojektowanym fundamentem budowli.
For the purposes of the construction of a new diversion weir on the Nysa Kłodzka River in Nysa, instead of geotechnical investigations required by Construction Law, only geological investigations were performed. The depth of subsoil recognition was too small and the number of boreholes, probing as well as the scope of the laboratory test did not meet the requirements of the third geotechnical category. Consequently, the layers arrangement and geotechnical parameters contained in the engineering - geological documentation were inconsistent with the reality. This caused incorrect design of the weir. In addition, according to the documentation, below the bottom of the wide foundation excavation, the cohesive soils in stiff state were located. In fact, there were suffosive fine and silty sands with a thickness more than 4.5 m with a few interbeddings of cohesive soil. Design based on the incorrect subsoil characteristics caused that sheet piling was ended in the sands only 2.5 m below the weir foundation level. While excavation, at a depth of 7 m, the piping took place. The rapid displacement of the lower end of the sheet piling has occurred, and excavation was filled with soil. It caused the total loosening of soil below foundation of the designed structure.
Źródło:
Acta Scientiarum Polonorum. Architectura; 2016, 15, 2
1644-0633
Pojawia się w:
Acta Scientiarum Polonorum. Architectura
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies