contact problems with friction, adhesion and wear in orthopaedic biomechanics. Part I - general developments
Autorzy:
Rojek, J.
Telega, J. J.
Powiązania:
https://bibliotekanauki.pl/articles/279902.pdf
Data publikacji:
2001
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
bone-implant interface
contact
adhesion
friction
Opis:
The present paper is a continuation of the contribution by Rojek and Telega (1999). An alternative adhesion law is used to the study of the bone-implant interface. Various problems related to the bone-implant interface are discussed.
Zagadnienia kontaktowe z tarciem, adhezją i zużyciem w biomachanice ortopedycznej. Część I - Rozważania ogólne. Niniejsza praca stanowi kontynuację wcześniejszej pracy autorów, por. Rojek i Telega (1999). Zastosowano alternatywny model adhezji dla opisu interfazy kość-implant. Przedyskutowano równierz szereg zagadnień związanych z tą interfazą.
Źródło:
Journal of Theoretical and Applied Mechanics; 2001, 39, 3; 655-677
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stanowisko do badań jakości osadzenia trzpienia implantu w kości
Quality research workstation for the mandrel implant mounting in bone tissue
Autorzy:
Zaczyk, M
Jasińska-Choromańska, D
Miśkiewicz, A
Powiązania:
https://bibliotekanauki.pl/articles/99177.pdf
Data publikacji:
2010
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
implant kości
badanie eksperymentalne
stanowisko pomiarowe
bone implant
experimental study
measuring position
Opis:
W poniższej pracy przedstawiono rozwiązanie konstrukcyjne stanowiska do eksperymentalnej oceny jakości osadzenia implantu w tkance kostnej. Praca opisuje sposób realizacji badań eksperymentalnych, których wyniki mogą stanowić bazę do oceny jakości rozwiązania konstrukcyjnego implantu dobieranego według indywidualnych cech pacjenta. Jako główne zadanie stanowiska przewiduje się możliwość weryfikacji, różnych rozwiązań konstrukcyjnych trzpienia implantu osadzonego w kości.
There is presented the design solution of a workstation for experimental estimation of quality implant mounting in bone tissue. The publication describes a manner of realization of experimental research. The results of research will be a base of quality estimation for implant design solution, which is selected on base of individual characteristics of patient. The main workstation task became a capability of verification design solution of mandrel implant mounting in bone tissue.
Źródło:
Aktualne Problemy Biomechaniki; 2010, 4; 279-284
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pediatric and adolescent bone-anchored implant. Skin changes and complications
Autorzy:
Wolfovitz, Amit
Grobman, Ariel
Snapp, Hillary A
Telischi, Fred F
Powiązania:
https://bibliotekanauki.pl/articles/1398941.pdf
Data publikacji:
2021
Wydawca:
Index Copernicus International
Tematy:
adolescent
bone-anchored implant
local complications
skin changes
Opis:
Objective: To assess the contributing factors for development of skin changes and local complications in the pediatric and adolescent population who underwent bone-anchored implantation (BAI). Methods: Retrospective chart review of pediatric and adolescent patients (age 0–17 years) who underwent BAI for mixed hearing loss, conductive hearing loss, and single-sided deafness, at a tertiary care academic center. Demographic, clinical, implant type and surgical variables were collected and analyzed to identify their contribution to the development of skin changes and local complications. Results: Thirty-nine BAI surgeries were performed in 28 subjects during the review period. The mean age of implantation was 10.5 ± 3.4 years (5–16 years). Skin changes and local complications occurred in 61.5% (24/39) of BAIs performed. In total, 75% (18/24) were attributed to local complications, and 25% (6/24) to skin changes. Revision surgery was required in 41.0% (16/39) of cases. The mean age upon revision with either skin changes or local complications, local complications alone, and skin changes alone was 14.6 ± 3.3 years (7.25–19), 13.4 ± 4.0 years (7.3–17), and 16.1 ± 1.2 years (13.8–17) respectively with no difference between the groups. Among implants with skin changes and local complications the abutment survival was found to be 33.3% at 6.75 years following implantation. No significant difference of demographic and clinical factors was noted when looking at cases with and without skin changes and local complications. Higher rates of skin changes and local complications were noted in two-stage techniques, non-linear incision and the use of absorbable sutures. Conclusion: Fewer skin changes/local complications were observed with linear incision/punch technique, single stage, and non-absorbable skin sutures. Abutment survival with skin changes and local complications plateaus at 6.75 years following implantation. The potential need for revision surgery and longer abutment replacement during puberty, presumably when scalp soft tissue thickens, should be considered prior to initial implantation of younger children, with information given to their care givers
Źródło:
Polski Przegląd Otorynolaryngologiczny; 2021, 10, 1; 1-8
2084-5308
2300-7338
Pojawia się w:
Polski Przegląd Otorynolaryngologiczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mechanical response at peri-implant mandibular bone for variation of pore characteristics of implants: A Finite Element Study
Autorzy:
Sarkar, Sulagna
Sahu, Tikeshwar Prasad
Datta, Arijit
Chandra, Nimesh
Chakraborty, Arindam
Datta, Pallab
Majumder, Santanu
Chowdhury, Amit Roy
Powiązania:
https://bibliotekanauki.pl/articles/307131.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
implant stomatologiczny
uszczelnianie
FEM
porous dental implant
pore size
percentage porosity
bone-implant interface
finite element analysis
stress and strain
Opis:
In this paper, the mechanical response of generic dental implants having calculated porosities with varying pore-sizes has been evaluated. The purpose of this study was to compare the developed stress-strain of designed porous implants (i.e., stress at the implant and strain at the peri-implant bone) with that of the non-porous implant. Methods: 3D model of a mandible was prepared from CT scan data and nine generic dental implant models have been designed having 10%, 20%, and 30% porosity with 500, 700, and 900 micron pore size along with a non-porous model for carrying out FE analyses. First, failure analyses of implants, under a biting force of 250 N have been performed. Next, the remaining implants have been further evaluated under average compressive chewing load of 100 N, for mechanical responses at bone-implant interface. Results: Von Mises strain at the peri-implant mandibular bone increases with the increase in percentage porosity of the implant material and maximum implant stress remained much below the yield stress level. Conclusion: Implant stiffness and compressive strength vary as a function of porosity and pore size. Strain obtained on the peri-implant bone is sufficient enough to facilitate better bone growth with the 700 micron pore size and 30% porosity, thus reducing the effect of stress shielding.
Źródło:
Acta of Bioengineering and Biomechanics; 2019, 21, 2; 83-93
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mikrogranule hydroksyapatytowe pokrywane poli(D,L-laktydem) jako implant kostny i nośnik antybiotyku
Hydroxyapatite microspheres coated with poly(D,L-lactide) as bone filler and antibiotic delivery system
Autorzy:
Jelonek, A.
Skórska-Stania, A.
Myciński, P.
Zarzecka, J.
Powiązania:
https://bibliotekanauki.pl/articles/284446.pdf
Data publikacji:
2013
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
granule hydroksyapatytowe
polilaktyd
kompozyt
kontrolowane uwalnianie leków
implant kostny
hydroxyapatite granules
polylactide
composite
controlled drug release
bone implant
Opis:
Wciąż nie udało się otrzymać implantu kostnego, który charakteryzowałby się wysoką biozgodnością i bioaktywnością, osteokonduktywnością, odpowiednimi właściwościami mechanicznymi oraz dobrą poręcznością chirurgiczną. Dodatkową zaletą tego typu materiału powinna być możliwość dostarczenia antybiotyku w wybrane miejsce ludzkiego organizmu w celu zapobiegania rozwojowi potencjalnych infekcji związanych z jego wszczepianiem. Opracowano nowy kompozytowy nośnik leku, składający się z porowatych granul hydroksyapatytowych pokrywanych poli(D,L-laktydem) z klindamycyną, mający znaleźć zastosowanie jako implant kostny w chirurgii szczękowo-twarzowej. Właściwości materiałów wykorzystanych do produkcji implantu zostały zbadane z użyciem metodXRD, FTIR, BET oraz DSC. Rozmiar i morfologię granul (250-1000μm) określono za pomocą mikroskopii SEM. Technika ta posłużyła także do określenia rozmiaru (10-40 μm) oraz rozmieszczenia porów. Udział objętościowy porów został oszacowany za pomocą metody hydrostatycznej. Przygotowano cztery grupy granul z różną zawartością klindamycyny. Zbadano właściwości uwalniania (trwającego 15-22 dni) leku z warstwy polimerowej. Od pierwszej godziny, aż do końca eksperymentu, obserwowano aktywność bakteriobójczą uwolnionej klindamycyny. W przypadku dwóch grup granul przez pierwszych pięć dni szczep bakteryjny gronkowca złocistego wykazywał wrażliwość lub średnią wrażliwość na uwolniony lek. Przedstawione w niniejszej pracy wyniki badań dowodzą, że opisywany kompozyt może znaleźć zastosowanie jako potencjalny implant kostny i nośnik leków. Prowadzone są dalsze badania nad zaprezentowanym materiałem.
The problem of developing the bone implant, characterized by high biocompatibility, bioactivity, osteoconductivity, suitable mechanical properties and good surgical handiness, is still not solved. Additional advantage of such material should be the capability of delivering an antibiotic to a chosen part of the human body in order to prevent occurrence of post-operative infections. A novel drug delivery system, composed of porous hydroxyapatite granules with poly(D,L-lactide) coating incorporating clindamycin, was engineered for use as a bone filler in oral and maxillofacial surgery. The properties of the materials, used to obtain the implant, were examined by the use of XRD, FTIR, BET and DSC methods. The size (250-1000μm) and morphology of granules were determined with SEM. This technique was also applied to investigate the size (10-40 μm) and distribution of pores. The solvent accessible pore volume was evaluated by the hydrostatic method. Four groups of granules with different concentrations of clindamycin were prepared. The properties of drug release (lasting 15 to 22 days) from the polylactide layer were studied. The antimicrobial activity of the released clindamycin was observed from the first hour till the end of the experiment. The Staphylococcus aureus strain was susceptible or intermediately susceptible to the released drug during first 5 days for two studied groups. These experimental results indicate that the studied composite material may be used as a potential bone implant and drug carrier. The described system is still under investigation.
Źródło:
Engineering of Biomaterials; 2013, 16, 120; 19-29
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mock-up in hip arthroplasty pre-operative planning
Autorzy:
Zanetti, E. M.
Bignardi, C.
Powiązania:
https://bibliotekanauki.pl/articles/306839.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
hip steam
primary stability
finite element method
bone-implant interface
kości
współpraca na powierzchni kość-implant
metoda elementów skończonych
Opis:
The correct estimation of stem boundary conditions in hip arthroplasty cannot be performed simply by subtracting the prosthesis volume from the bone volume: the stem implant path needs to be taken into account. Digital mock-up is a technique commonly applied in the automotive field which can be used for this aim. Given a certain femur, a stem, and an implantation path, the volume of the removed bone stock can be evaluated, as well as the final contact area between the bone and the stem, and, section by section, the residual cortical bone thickness. The technique proved to be useful: if the stem implant path is not considered, the removed bone stock volume can be underestimated up to 6%, while the contact area extension can be overestimated up to 28%. On the whole, a new methodology has been set up and tested, which can be usefully employed to accurately establish stem boundary conditions in the pre-operative planning stage, and in order to perform a reliable structural stress analysis. The methodology implemented here by experienced researchers can be made available to surgeons, setting up an apposite software suite.
Źródło:
Acta of Bioengineering and Biomechanics; 2013, 15, 3; 123-128
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nanocząstki w biokompozytach polimer – ceramika do regeneracji tkanki kostnej
Nanoparticles in polymer – ceramic biocomposites for bone tissue regeneration
Autorzy:
Bartolewska, Magdalena
Powiązania:
https://bibliotekanauki.pl/articles/36108384.pdf
Data publikacji:
2021
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Ceramiki i Materiałów Budowlanych
Tematy:
nanocząstka
nanomateriał
implant kostny
kompozyt
metal
inżynieria tkankowa
medycyna regeneracyjna
nanoparticle
nanomaterial
bone implant
composite
tissue engineering
regenerative medicine
Opis:
Medycyna regeneracyjna staje się szybko rozwijającą techniką w współczesnej biomedycynie. Coraz częściej na świecie są wykorzystywane nanocząstki do naprawiania i leczenia uszkodzonych komórek. Ten artykuł przeglądowy przedstawia wiedzę na temat kompozytów, składających się z polimeru oraz hydroksyapatytu, modyfikowanych nanocząstkami i ich zastosowaniami w medycynie regeneracyjnej.
Regenerative medicine is becoming a rapidly developing technique in modern biomedicine. Nanoparticles are used increasingly to repair and heal damaged cells. The paper presents knowledge about the use of nanoparticles in the modification of polymer and hydroxyapatite composites and their applications in regenerative medicine.
Źródło:
Szkło i Ceramika; 2021, 72, 4; 28-30
0039-8144
Pojawia się w:
Szkło i Ceramika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative studies of various methods of mounting the implant mandrel within the bone
Autorzy:
Zaczyk, M.
Jasińska-Choromańska, D.
Powiązania:
https://bibliotekanauki.pl/articles/385143.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
mounting of an implant mandrel within the osseous tissue
endoprosthesis
implant-bone contact
Opis:
The paper presents results of studies pertaining to evaluation of a quality (compressive strength of mounting the implant within the bone) of mounting the implant mandrel within the osseous tissue for various relevant techniques. The presented results are related to selected techniques of mounting the implant mandrel within a bone. The comparison has been carried out for cement-less mandrels with a smooth mandrel of the endoprosthesis, porous cementless endoprostheses as well as mandrels made of bioactive materials.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2012, 6, 3; 33-36
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tissue engineering of bone: the role of osteoblasts in osteogenesis and peri-implant bone healing
Autorzy:
Wróbel, E.
Witkowska-Zimny, M.
Powiązania:
https://bibliotekanauki.pl/articles/284980.pdf
Data publikacji:
2013
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
bone tissue engineering
osteoblasts
human bone-derived cells
peri-implant bone healing
osteogenesis
cell culture
Opis:
Osteoblasts are cells of mesenchymal origin, which rebuild resorbed bone by synthesizing bone matrix proteins and by inducing bone matrix mineralization. Osteoblasts play a crucial role in creating and maintenance of healthy bone architecture, bone repair, and peri-implant bone healing (osseointegration). These bone-forming cells are also involved in regulation of osteoclasts function, and hence bone resorption in osteoclastogenesis process. We have presented our own studies on the subsequent stages of differentiation of Human Bone-Derived Cells (HBDCs) that could be a good candidate as an autogenous source for reconstruction and rebuilding of own patient's bone using tissue engineering methods. In this review we discussed the biology of osteoblasts, compared with the HBDCs cultures, under the influence of growth factors (FGF-2, TGF-ß, IGF, PDGF) and hormones (PTH, 1,25-dihydroxyvitamin D3, leptin). Our review is also focused on the participation of intercellular adhesion proteins (cadherins, claudins, connexin, 'OsteoMacs'), transcription factors (Cbfal, Msx-2, Osx, ATF4), and others molecules (RANKL, OPG, BMP2, lactofferin, PPARY) in modulating osteoblasts functions on the basis of current reports, throwing new light on the involvement of osteoblasts during osteogenesis and peri-implant bone healing.
Źródło:
Engineering of Biomaterials; 2013, 16, 119; 2-7
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena dokładności wyników eksperymentalnego badania połączenia implant-kość
Result accuracy evaluation of experimental studies of an implant-bone connection
Autorzy:
Zaczyk, M.
Jasińska-Choromańska, D.
Kołodziej, D.
Powiązania:
https://bibliotekanauki.pl/articles/153013.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiary biomechaniczne
eksperymentalne badania połączenia implant-kość
jakość osadzenia implantu w tkance kostnej
biomechanical measurement
experimental tests implant-bone
implant fixation quality in the bone
Opis:
Praca zawiera opis metodyki wyznaczenia niepewności dla pomiarów biomechanicznych realizowanych podczas badań eksperymentalnych osadzenia implantu w tkance kostnej. Przedstawiona procedura szacowania niepewności pozwoliła określić, które z etapów procesu pomiarowego eksperymentu miały znaczący wpływ na błędy wyników i z jaką ufnością można podchodzić do wartości liczbowych, opisujących badaną własność biomechaniczną.
The paper presents a methodology of determining uncertainty in biomechanical measurements realized during experimental studies of an implant mounting within an osseous tissue. The presented procedure of evaluating the uncertainty allows one to determine which of the stages of the measurement process of the experiment had a significant influence on the errors of the obtained results, and how much is a confidence level corresponding to the numerical values describing a studied biomechanical property. Values of biomechanical properties are usually obtained in an experimental way. A unification of the analysis of the studies is a decisive factor with respect to the reliability and usability of the results, as well as a possibility of comparing these values for a given property obtained in other experiment. Analysis of the sources of the measurement uncertainties with respect to the realized process of recording the given numeric values of the properties searched for, provided it has been carried out reliably, allows one to create a mathematical equation of the related process. Analysis of evaluating uncertainty related to the presented experiment proved that both the measurement equipment and the methodology of experimental studies were selected correctly, and the most significant influence on the resultant errors had its source in biomechanical properties of the materials used for building the object of experiments. It was impossible to eliminate error sources related to the applied osseous material, since each bone used for building a sample originated from a different specimen, having at the same time its own individual characteristics.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 6, 6; 579-582
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies