Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "body temperature" wg kryterium: Temat


Tytuł:
Changes in selected morphological parameters and body compositio, as well as mean body surface temperature assessed by thermal imaging, in women after abdominal liposuction
Autorzy:
Chudecka, Monika
Dmytrzak, Anna
Lubkowska, Anna
Powiązania:
https://bibliotekanauki.pl/articles/1055005.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Szczeciński. Wydawnictwo Naukowe Uniwersytetu Szczecińskiego
Tematy:
body component
body temperature
fat
liposuction
thermography
Opis:
The aim of this study was to assess changes in selected morphological parameters and body composition, as well as in the mean body surface temperature determined by thermal imaging, in women after abdominal liposuction. As abdominal tissue edema and inflammation often persist after liposuction, body composition and surface temperatures were analyzed 3 months after surgery, during a control visit to the clinic. The 12-week delay allowed to eliminate the confounding effects of post-surgical inflammation on our results. We found a statistically significant decrease in all the analyzed morphological parameters and a change in body composition. A reduction in the subcutaneous fat tissue in the abdomen resulted in upward trends in the surface temperature of most of the analyzed areas, with a highly significant increase in the abdominal area. These studies can be considered pioneering and significant in confirming the role of subcutaneous fat as a factor regulating the body surface temperature.
Źródło:
Central European Journal of Sport Sciences and Medicine; 2016, 14, 2; 21 - 26
2300-9705
2353-2807
Pojawia się w:
Central European Journal of Sport Sciences and Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Koncepcja monitoringu temperatury ciała cieląt
The concept of calf body temperature monitoring
Autorzy:
Jędruś, A.
Lipiński, M.
Powiązania:
https://bibliotekanauki.pl/articles/288554.pdf
Data publikacji:
2010
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
temperatura ciała
cielę
monitoring
calf
body temperature
Opis:
Przedstawiono wyniki badań pomiaru temperatury cieląt z zastosowaniem różnych narzędzi pomiarowych. Analizy wykazały, że zaproponowany dotykowy sposób pomiaru temperatury cieląt z użyciem termistora zainstalowanego w automatycznej stacji odpajania cieląt jest niepewny i nieefektywny. Może być on stosowany tylko jako źródło sygnałów alarmowych o podwyższonej temperaturze ciała cieląt. Z kolei najdokładniejszym sposobem pomiaru temperatury ciała cieląt jest stosowanie kamery termowizyjnej, ale jej wadą jest bardzo wysoka cena.
The work presents the research results for calf temperature measurement using various measuring tools. Completed analyses have shown that the proposed touch measurement method for calf temperature using a thermistor installed in automatic feeding stations is unreliable and ineffective. It may be used only as a source of alarm signals in case of high calf body temperature. As concerns the calf body temperature measurement, using a thermovision camera is the most precise method, however a very high price is its disadvantage.
Źródło:
Inżynieria Rolnicza; 2010, R. 14, nr 1, 1; 229-234
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie rozkładu temperatury powierzchniowej ciała kobiet i mężczyzn za pomocą termowizji
The comparison of surface body temperature distribution between men and women by means of thermovision
Autorzy:
Dębiec-Bąk, A.
Skrzek, A.
Powiązania:
https://bibliotekanauki.pl/articles/262089.pdf
Data publikacji:
2012
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
temperatura ciała
badania termowizyjne
termoregulacja
body temperature
thermovision examination
thermoregulation
Opis:
Utrzymanie stałej temperatury ciała jest warunkowane prawidłowymi funkcjami fizjologicznymi organizmu człowieka. Równowaga cieplna będąca fizyczną wypadkową między ciepłem wytworzonym przez organizm a ciepłem rozproszonym osiągana jest poprzez precyzyjną regulację biologiczną. Przekazywanie ciepła z narządów wewnętrznych do tkanek powierzchniowych, w tym do skóry, a także zjawisko odwrotne angażuje do termoregulacji krążenie skórne. Celem pracy jest analiza zróżnicowania rozkładu temperatury powierzchniowej w różnych obszarach ciała pomiędzy grupą młodych zdrowych kobiet i młodych zdrowych mężczyzn. Badanie objęło 240 zdrowych studentów Akademii Wychowania Fizycznego we Wrocławiu, obojga płci, w wieku 20–25 lat. Przebadanych zostało 154 kobiet w wieku 19,32–25,92 lat (średnia wieku 21,58 š 1,55) oraz 86 mężczyzn w wieku od 19,38 do 25,34 lat (średnia wieku 22,22 š 1,64). Wykonano rejestrację rozkładu temperatur 29 obszarów ciała kamerą termowizyjną Flir Systems ThermoVision A20M. Przeprowadzone badania termowizyjne wykazały duże zróżnicowanie temperatury powierzchniowej w zależności od badanego obszaru ciała. W większości analizowanych rejonów ciała stwierdzono niższe temperatury w grupie badanych kobiet niż mężczyzn.
Maintenance of a constant body temperature is determined by the propoer physiological functions of the human organism. The thermal balance, resulting from the heat produced by the organism and the diffusion of the heat, is achieved by the precise biological regulation. The heat flow from the internal parts of the organism towards the superficial body layers and skin and in the opposite direction, requires the activation of the skin circulation. The aim of the study was to compare the temperature distribution within various body regions between healthy young men and women. The examination included 240 young healthy students of the University School of Physical Education in Wroclaw, aged 20-25 years, among them 154 women aged 19,32- 25,92 years (mean age 21,58 š 1,55), as well as men aged 19,38-25,34 years (mean age 22,22 š 1,64). The temperature distribution in 29 regions was recorded by means of thermovision camera Flir Systems ThermoVision A20M. Examination revealed that there are significant differences in the temperature, depending on the examined body region. Prevalently, the lower temperatures were noticed in women than in men.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2012, 18, 1; 25-30
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Circadian rhythm of core body temperature. Part 2, Hyperbaric environment influence on circadian rhythm of core body temperature
Rytmika dobowych zmian temperatury głębokiej ciała. Cz.2, Wpływ środowiska hiperbarycznego na okołodobową zmienność temperatury głębokiej ciała
Autorzy:
Słomko, J.
Kozakiewicz, M.
Klawe, J. J.
Tafil-Klawe, M.
Siermontowski, P.
Zalewski, P.
Powiązania:
https://bibliotekanauki.pl/articles/366424.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Medycyny i Techniki Hiperbarycznej
Tematy:
circadian rhythm
body temperature
hyperbaric
rytmika okołodobowa
temperatura ciała
hiperbaria
Opis:
The aim of this study was to analyse dynamic fluctuations in the circadian rhythm of the core body temperature in healthy adults exposed to conditions in a hyperbaric chamber, using fully objective-telemetric measurement methods. The study group consisted of 13 healthy males (age 32±6.4 years, height 1.85±0.1 m, body weight 84.00±6.3 kg; BMI 24.7±1.2 kg/m2). The core body temperature (CBT) was measured with the Vital Sense telemetry system. The volunteers were placed in a hyperbaric chamber, exposed to compression of 400 kPa, with the exposure plateau of approx. 30 minutes, followed by gradual decompression. The mean core temperature was 36.71oC when registered within 10 minutes before the exposure, 37.20oC during the exposure, 37.27oC one hour after the exposure, 37.36oC 2 hours after the exposure, and 37.42oC three hours after the exposure. The conducted observations show that onehour stay in a hyperbaric chamber at a depth of 30 m results in an increase in the body temperature, particularly significant after the exposure ends, and maintained for at least 3 hours after the exposure.
Celem badań była analiza dynamicznych zmian okołodobowej rytmiki temperatury głębokiej ciała u osób zdrowych poddanych ekspozycji w komorze hiperbarycznej, wykorzystując w pełni obiektywne - telemetryczne metody pomiarowe. Grupę badaną stanowiło 13 zdrowych mężczyzn (wiek 32±6,4 lat; wysokość ciała 1,85±0,1 m, masa ciała 84,00±6,3 kg; BMI 24,7±1,2 kg/m2). Pomiaru temperatury głębokiej ciała (CBT – Core Body Temperature) badanych osób dokonywano przy użyciu telemetrycznego systemu pomiarowego Vital Sense. Ochotnicy zostali umieszczeni w komorze hiperbarycznej i sprężeni do ciśnienia 400kPa, plateau ekspozycji wynosiło ok. 30 minut po czym nastąpiła stopniowana dekompresja. Średnia temperatura wewnętrzna zarejestrowana w przedziale czasowym 10 min przed ekspozycją wyniosła Twew.=36,71oC, podczas ekspozycji Twew. = 37,20oC, godzinę po ekspozycji Twew. = 37,27oC, 2 godziny po ekspozycji Twew. = 37,36oC, 3 godziny po ekspozycji Twew. = 37,42oC. Z przeprowadzonych obserwacji wynika, że godzinny pobyt w komorze hiperbarycznej na głębokości 30 m wpływa na wzrost temperatury ciała, szczególnie istotny po zakończeniu i utrzymujący się przynajmniej 3 godziny po ekspozycji.
Źródło:
Polish Hyperbaric Research; 2016, 4(57); 19-28
1734-7009
2084-0535
Pojawia się w:
Polish Hyperbaric Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Verification of electronic device technology for measurement and evaluation of thermal exposure of fire fighters and members of rescue teams
Autorzy:
Bernatíková, Šárka
Tomášková, Hana
Bužga, Marek
Jirák, Zdeněk
Novák, Petr
Babjak, Ján
Kot, Tomáš
Krys, Václav
Jánošík, Ladislav
Powiązania:
https://bibliotekanauki.pl/articles/2162587.pdf
Data publikacji:
2017-12-05
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
heart rate
correlation
body temperature
fire fighter
physical strain
thermal load
Opis:
Background The work of members of rescue teams could be associated with very high physical and thermal loads. If not timely interrupted, any extreme labour-thermal load may lead to a failure of the body and fatal collapse. This risk may be significantly reduced by devices that monitor the response of the body during the intervention and inform rescuers about the need to interrupt the exposure when the critical value of the reference indicator is achieved. The aim of the study was to test the correlation between the data of the newly developed device for signaling the strain of rescuers and the indicators of physiological response of the body. Material and Methods The tests were performed on 2 physically fit fire fighters dressed in a protective rescue suit and using insulating breathing apparatus, over a wide range of heat load under a model load on a bicycle ergometer in a climatic chamber. Results The study provided a significant correlation between the body temperature measured in the ear canal and the temperature under the suit sensed by the tested device – the Safety Ambient Monitor (SAM) (R = 0.9007). The temperature under the suit also correlated with the temperature of the chest skin (R = 0.8928) and heart rate (R = 0.8613). Conclusions A statistically significant correlation was proven between the temperature sensed by the SAM and the body temperature. The technical solution of sensing the temperature under the suit using the verified SAM technology does not affect or limit fire fighters in their work and minimizes the possibility of damage to the sensor and signaling failures. Med Pr 2018;69(1):1–11
Źródło:
Medycyna Pracy; 2018, 69, 1; 1-11
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Exercise thermoregulation in Thai and Polish male subjects
Autorzy:
Tyka, A
Kubica, R.
Zuchowicz, A.
Szygula, Z.
Golab, S.
Czubala, M.
Cherdrungsi, P.
Powiązania:
https://bibliotekanauki.pl/articles/69354.pdf
Data publikacji:
1995
Wydawca:
Polskie Towarzystwo Fizjologiczne
Tematy:
body temperature
rectal temperature
human physiology
physical exercise
Thai male
body weight
thermoregulation
warm environment
acclimatization
Polish male
Źródło:
Journal of Physiology and Pharmacology; 1995, 46, 2
0867-5910
Pojawia się w:
Journal of Physiology and Pharmacology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Effect of Bright Light on Physiological Circadian Rhythms and Subjective Alertness of Shift Work Nurses in Iran
Autorzy:
Kakooei, H.
Ardakani, Z. Z.
Ayattollahi, M. T.
Karimian, M.
Saraji, G. B.
Owji, A. A.
Powiązania:
https://bibliotekanauki.pl/articles/90524.pdf
Data publikacji:
2010
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
circadian rhythms
shift work
nurse
bright light
alertness
melatonin
cortisol
body temperature
Opis:
In this study, the effects of bright light (BL) on the rhythms in body temperature, plasma melatonin, plasma cortisol and subjective alertness, in 34 shift work nurses at a university hospital were assessed. They were exposed to very BL (4 500 lx) during 2 breaks (21:15–22:00 and 3:15–4:00) or dim light (300 lx). The subjects were studied under 24 h of realistic conditions during which their plasma cortisol and melatonin were measured at 3-h intervals; their body temperature was also measured during and after night shift work. Subjective alertness was evaluated with the Karolinska sleepiness scale. Administration of BL significantly suppressed night-time melatonin levels. A one-way ANOVA revealed that BL tended to increase cortisol levels and body temperature and significantly improved alertness. These results demonstrate that photic stimulation in a hospital setting can have a powerful influence on the adjustment of the circadian system.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2010, 16, 4; 477-485
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rytmika dobowa temperatury głębokiej ciała (część I): zastosowanie nowoczesnych systemów telemetrycznych w monitorowaniu zmienności temperatury głębokiej ciała
The circadian rhythm of core body temperature (part I): the use of modern telemetry systems to monitor core body temperature variability
Autorzy:
Słomko, J.
Zalewski, P.
Powiązania:
https://bibliotekanauki.pl/articles/1359161.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Medycyny i Techniki Hiperbarycznej
Tematy:
temperatura ciała
rytmy okołodobowe
pomiar telemetryczny
body temperature
circadian rhythms
telemetric measurement
Opis:
Najlepiej poznane rytmy dobowe człowieka to: rytm sen–czuwanie, okołodobowa zmienność temperatury głębokiej ciała, dobowe zmiany ciśnienia tętniczego krwi oraz częstości skurczów serca, dobowe zmiany wydzielania hormonów: m.in. melatoniny, kortyzolu, hormonu wzrostu, prolaktyny. Temperatura głęboka ciała u ludzi ma swój charakterystyczny, sinusoidalny przebieg, z wartościami maksymalną około godz. 15:00-17:00 i minimalną, około godz. 03:00-05:00 rano. Analiza piśmiennictwa wskazuje, że na uzyskiwane wyniki dotyczące temperatury głębokiej ciała w dużej mierze ma rodzaj zastosowanej metody pomiaru. W literaturze można spotkać różne sposoby pomiaru temperatury głębokiej ciała, stosowane w zależności od protokołu badania. Jedną z nowszych metod pomiaru wewnętrznej i zewnętrznej temperatury ciała jest zastosowanie zdalnych czujników temperatury, transmitujących zmierzone wartości drogą radiową. Zaletami tej metody są: możliwość uzyskania ciągłego pomiaru temperatury głębokiej, obserwacja dynamicznych zmian temperatury głębokiej ciała zachodzących w cyklu okołodobowym oraz dokładność pomiaru, powtarzalność i wiarygodność uzyskanych wyników, co prezentowane jest w wielu doniesieniach naukowych.
The best known daily rhythms in humans include: the sleep-wake rhythm, the circadian core body temperature variability, daily fluctuations in arterial blood pressure and heartbeat frequency, and daily changes in hormone secretion: e.g. melatonin, cortisol, growth hormone, prolactin. The core body temperature in humans has a characteristic sinusoidal course, with the maximum value occurring between 3:00-5:00 pm and the minimum between 3:00-5:00 am. Analysis of literature indicates that the obtained results concerning core body temperature are to a large extent influenced by the type of method applied in the measurement. Depending on test protocols, we may apply various methodologies to measuring core body temperature. One of the newest methods of measuring internal and external body temperature consists in the utilisation of remote temperature sensors transmitting the obtained value via a radio signal. The advantages of this method includes the ability to perform: continuous core temperature measurement, observe dynamic changes in core body temperature occurring in circadian rhythm and the repeatability and credibility of the obtained results, which is presented in numerous scientific reports.
Źródło:
Polish Hyperbaric Research; 2016, 2(55); 79-83
1734-7009
2084-0535
Pojawia się w:
Polish Hyperbaric Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermovision analysis of surface body temperature changes after thermal stimulation treatments in healthy men
Autorzy:
Gruszka, K.
Szczuka, E.
Całkosiński, I.
Sobiech, K. A.
Chwałczyńska, A.
Powiązania:
https://bibliotekanauki.pl/articles/307175.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
termowizja
diagnostyka termowizyjna
kriostymulacja
temperatura ciała
thermovision
thermal imaging
cryostimulation
massage volcanic stone
men’s body temperature
Opis:
Among thermal stimulation treatments that have a beneficial effect on the human body general application of cold and various forms of massage are mentioned which can be assessed by means of thermovision analysis. The aim of the study was to evaluate changes in the distribution of surface body temperature under the influence of whole-body cryostimulation, classical massage and hot stone massage. Materials and methods: The study was conducted on a group of 40 men aged 20–24 years. They were subjected to a cryostimulation treatment at –120 °C and –140 °C, and to heat-stimulating treatments in the form of massages. Before the treatment, blood pressure and heart rate were measured. Temperature distribution in the 12 areas of the body surface was recorded using a Thermo Vision A20M Thermo Vision Camera with Therma CAM Researcher 2.8 software. Results: Statistically significant differences between cryostimulation treatments in the left upper limb and the back of the trunk were found. After heat-stimulating treatments, a statistically significant increase in temperature after classic massage was observed in the lower limbs, and a similar increase in temperature was noted in the rear of the pectoral girdle and of the trunk after hot stone massage. Conclusions: The thermovision analysis showed a great variation of body surface temperature depending on the body area. The higher changes in temperature, of up to 20%, were found within the upper and lower extremities in the group treated with cryostimulation. After heat-stimulating treatments, lower temperature differences, of 2–6%, were observed, the largest within the trunk and the lower limbs.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 2; 79-87
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie termowizji w ocenie zmian temperatury powierzchniowej ciała po kąpieli morsów (regular winter swimmer)
Application of thermovision to body surface temperature analysis at regular winter swimmers
Autorzy:
Sobiech, K. A.
Gruszka, K.
Chwałczyńska, A.
Jędrzejewski, G.
Powiązania:
https://bibliotekanauki.pl/articles/153672.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
termowizja
morsowanie
temperatura powierzchniowa ciała
thermovision
winter swimming
body surface temperature
Opis:
Przedstawiono wyniki badań, których celem było porównanie zmian temperatury powierzchniowej ciała u morsów zrzeszonych w Klubie „Wrocławskie Morsy”, poddanych kąpieli w lodowatej wodzie w styczniu 2013 i 2014 roku. W badaniach wzięło udział 10 mężczyzn-morsów w wieku około 39 lat, BMI około 26,5, którzy odbyli 15 kąpieli w cyklu rocznym. Przed i po trwającej około 3 minuty kąpieli w lodowatej wodzie rejestrowano rozkład temperatury na powierzchni ciała kamerą termowizyjną Thermo Vision A20M, współdziałającą z komputerem osobistym zaopatrzonym w program Therma Cam Researcher 2.8. Warunki klimatyczne obydwu ekspozycji na zimno różniły się temperaturą (około 12˚C), ciśnieniem i wilgotnością. Po kąpieli w wodzie o temperaturze 2°C i powietrza (-11°C) stwierdzono obniżenie temperatury kończyn dolnych o 90% oraz oziębienie kończyn górnych o 60%. Wykazano różnicę około 20% pomiędzy temperaturą kończyn górnych z przodu i z tyłu co można tłumaczyć budową i składem tego rejonu ciała. Różnice warunków klimatycznych mogą odpowiadać za około 30% różnice temperatur po kąpieli w lodowatej wodzie w latach 2013-2014.
The aim of the study was to compare the body surface temperature changes at winter swimmers associated in "Wrocławskie Morsy", Wroclaw regular swimmers club, who immersed themselves in ice-cold water in January in years 2013 and 2014. The study involved 10 male winter swimmers (about 39 years of age, with BMI around 26.5) who participated in 15 immersions during each year. The distribution of body surface temperature was registered with a ther-mographic camera before and after three-minute-long treatments (i.e. baths) in ice-cold water. The thermographic camera used for the research was Thermo Vision A20M connected to a personal computer equipped with the Therma Cam Researcher programme (2.8 version). The atmospheric conditions of the pre- and post-treatment expositions differed in temperature (around 12°C), pressure and humidity. After the treatment in water of temperature at 2°C, and air of temperature at -11°C, a temperature decrease of 90% was determined in lower limbs, and a drop of 60% was established in upper limbs. A 20% difference was noted between the anterior and posterior surface areas of upper limbs, which can be explained by the structure and composition of the discussed body parts. Inconsistency of atmospheric conditions may constitute a source of around 30% discrepancy in the temperatures measured after the treatment in years 2013 and 2014.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 12, 12; 1112-1115
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Can snails run a fever?
Autorzy:
Zbikowska, E.
Wrotek, S.
Kozak, W.
Powiązania:
https://bibliotekanauki.pl/articles/83928.pdf
Data publikacji:
2012
Wydawca:
Uniwersytet Mikołaja Kopernika. Wydział Biologii i Ochrony Środowiska. Stowarzyszenie Malakologów Polskich
Tematy:
snail
pathogen
invasion
body temperature
fever
microhabitat
behavioural fever
reptile
amphibian
fish
arthropod
annelid
molecular mechanism
homoiothermic animal
Źródło:
Folia Malacologica; 2012, 20, 1
1506-7629
Pojawia się w:
Folia Malacologica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An automated system for body temperature monitoring of children, people with disabilities and bedridden people using a continuous analysis
Autorzy:
Turakulov, Azambek
Mullajonova, Fotima
Powiązania:
https://bibliotekanauki.pl/articles/328015.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
human body temperature
human health monitoring software
automated data processing system
temperatura ciała
monitorowanie temperatury
zautomatyzowany system przetwarzania danych
Opis:
The article discusses one of the ways to monitor human health through a continuous comparative analysis of skin temperatures on various parts of the body. Comparing the temperatures of such parts as the armpit, limbs of the arms and legs, it is proposed to draw a conclusion about the state of blood circulation and blood density. A detailed algorithm for processing the measured temperatures is presented. An automated data processing and notification system is proposed. The description of the initial version of the device developed by the authors is given, where the assumptions about possible health problems are notified using light lamps and an audio signal. An inexpensive Arduino NANO microcontroller is proposed as a technical tool for an information processing device.. The research results can be applied in automated systems as hardware and software. The device can be useful in constant monitoring the health status of newborns, people with serious disabilities and people with limited ability to move independently.
Źródło:
Diagnostyka; 2020, 21, 3; 31-40
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmiany wybranych wskaźników fizjologicznych oraz ocena stresu cieplnego pod wpływem kąpieli w saunie suchej i mokrej u młodych zdrowych kobiet
Changes in selected physiological indicators and thermal stress assessment under the influence of baths in a dry and wet sauna in young healthy women
Autorzy:
Pilch, Wanda
Piotrowska, Anna
Czerwińska-Ledwig, Olga
Zuziak, Roxana
Maciejczyk, Marcin
Tota, Łukasz
Bawelski, Marek
Pałka, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2162643.pdf
Data publikacji:
2019-12-03
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
temperatura ciała
sauna sucha
sauna mokra
stres cieplny
odczuwanie temperatury
obciążenie fizjologiczne
body temperature
dry sauna
wet sauna
heat stress
temperature sense
physiological strain
Opis:
Wstęp Kąpiele w saunie suchej i w łaźni parowej ze względu na różny stopień obciążenia cieplnego wywołują też różne reakcje organizmu. Duża wilgotność powietrza w saunie mokrej utrudnia parowanie potu ze skóry. Ponadto dynamika pocenia się jest różna u kobiet i mężczyzn. Celem pracy była analiza zmian wskaźników fizjologicznych oraz porównanie wpływu sauny suchej i mokrej na odczucie komfortu cieplnego ocenianego w skali termicznej Bedforda, a także zbadanie wielkości obciążenia fizjologicznego (physiological strain index – PSI) i skumulowanego wskaźnika obciążeń cieplnych (cumulative heat stress index − CHSI) u młodych zdrowych kobiet. Materiał i metody W badaniach wzięło udział 10 kobiet w wieku 22−24 lat. Pomiary w obu typach sauny prowadzono w fazie folikularnej cyklu miesięcznego. Każda sesja trwała 60 min i składała się z trzech 15-minutowych ekspozycji cieplnych z 5-minutowymi przerwami na odpoczynek i schłodzenie wodą. Temperatura w saunie suchej wynosiła 91±1,2°C, w mokrej – 59±1,3°C; wilgotność powietrza, odpowiednio: 18±0,7% i 60,5±0,8%. Dokonano pomiarów masy ciała, ciśnienia skurczowego (systolic blood pressure − SBP) i rozkurczowego (diastolic blood pressure − DBP), częstości skurczów serca (heart rate − HR), temperatury rektalnej ($ \text{T}_\text{re} $) i odczuć termicznych według skali Bedforda. Wyliczono współczynniki obciążenia fizjologicznego: PSI oraz CHSI. Wyniki Po saunie suchej średnie ubytki masy ciała badanych kobiet były istotnie wyższe niż po kąpieli w saunie mokrej. Po zabiegu w saunie mokrej zaobserwowano istotnie większe przyrosty $ \text{T}_\text{re} $ oraz HR. Oba zabiegi powodowały wzrost SBP. Podczas obu kąpieli ciśnienie rozkurczowe ulegało obniżeniu. Subiektywne odczucie uciążliwości zabiegu oraz PSI i CHSI było większe podczas kąpieli w saunie mokrej. Wnioski Ekspozycja cieplna w saunie mokrej stanowi większe obciążenie dla organizmu młodych kobiet niż taki sam zabieg w saunie suchej, a zmiany badanych cech są większe od tych, które zaobserwowano u mężczyzn poddanych podobnym obciążeniom termicznym. Med. Pr. 2019;70(6):701–710
Background There are differences between dry and wet sauna baths because of the heat load and human body’s reactions. High humidity in a wet sauna makes evaporation of sweat from the skin surface more difficult. In addition, the dynamics of sweating is different in men and women. The aim of the study was to assess changes in physiological indicators and to compare the impact of dry and wet saunas on the thermal comfort feeling, which was assessed using the Bedford thermal scale, and the physiological strain index (PSI) and the cumulative heat stress index (CHSI) in young healthy women. Material and Methods Ten women aged 22−24 years took part in the study. A session in each sauna lasted 60 min and consisted of 3 thermal 15-min exposures, in 5-min intervals for rest and cooling with water. The temperature in the dry sauna was 91±1.2°C and in the wet sauna 59±1.3°C, while the humidity was 18±0.7% and 60.5±0.8%, respectively. Body weight, systolic blood pressure (SBP), diastolic blood pressure (DBP), heart rate (HR), rectal temperature ($ \text{T}_\text{re} $) and the thermal sensation (Bedford scale) were also measured. The PSI and CHSI values were both calculated. Results The average weight loss after a dry sauna bath was significantly higher than after a wet sauna bath. Significantly higher increases in $ \text{T}_\text{re} $, as well as in HR were observed after treatment in the wet sauna, compared to the dry sauna. Both treatments resulted in an increase in SBP and a decrease in DBP. The arduousness of thermal discomfort and the levels of PSI and CHSI were skurgreater in the wet sauna bathing than in the dry sauna. Conclusions Heat exposure in the wet sauna creates a greater burden for young women’s bodies than the same dry sauna treatment, and the changes observed in the examined traits were higher than in men subjected to similar thermal loads. Med Pr. 2019;70(6):701–10
Źródło:
Medycyna Pracy; 2019, 70, 6; 701-710
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of sodium nitroprusside NO-donor on psychotropic activity of angiotensin II
Autorzy:
Wisniewski, K
Holy, Z.
Powiązania:
https://bibliotekanauki.pl/articles/70848.pdf
Data publikacji:
1995
Wydawca:
Polskie Towarzystwo Fizjologiczne
Tematy:
body temperature
sodium nitroprusside
psychomotor activity
brain
psychotropic activity
nitric oxide
pituitary hormone
rat
passive avoidance
angiotensin II
blood pressure
hormone
Źródło:
Journal of Physiology and Pharmacology; 1995, 46, 2
0867-5910
Pojawia się w:
Journal of Physiology and Pharmacology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Test of Firefighter’s Turnout Gear in Hot and Humid Air Exposure
Autorzy:
Holmer, I.
Kuklane, K.
Gao, C.
Powiązania:
https://bibliotekanauki.pl/articles/90221.pdf
Data publikacji:
2006
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
body temperature
heat stress
physiological strain
protective clothing
odzież ochronna
straż pożarna
pożar
temperatura powietrza
temperatura ciała
stres
zagrożenia zawodowe
strażak
Opis:
Five students of a rescue training school cycled at 50 W for 20 min at 20 oC before walking at 5 km/hr up to 30 min in a climatic chamber at 55 oC and 30% relative humidity. 4 different types of clothing ensembles differing in terms of thickness and thermal insulation value were tested on separate days. All subjects completed 28–30 min in light clothing, but quit after 20–27 min in 3 firefighter ensembles due to a rectal temperature of 39 oC or subjective fatigue. No difference in the evolution of mean skin or rectal temperature was seen for the 3 turnout ensembles. Sweat production amounted to about 1000 g in the turnout gears of which less than 20% evaporated. It was concluded that the small differences between the turnout gears in terms of design, thickness and insulation value had no effect on the resulting heat physiological strain for the given experimental conditions.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2006, 12, 3; 297-305
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies