Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "biomechanics" wg kryterium: Temat


Tytuł:
Problems related to mechanics in the design of external osteosynthesis
Wybrane zagadnienia mechaniki w projektowaniu ortopedycznych stabilizatorów zewnętrznych
Autorzy:
Jasińska-Choromańska, D. E.
Powiązania:
https://bibliotekanauki.pl/articles/280043.pdf
Data publikacji:
2010
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
biomechanics
modelling
osteosynthesis
Opis:
The external osteosynthesis is one of the methods of healing bone fractures. The idea of external fixators design consists in inserting into the bone fragments elements, which are coupled outside the limb by an element, called the frame of the fixator, having the fracture set. The external fixation is based on the principle of "load transfer". The design of a new generation of external fixators ought to employ some methods of mechanical analysis. Selected problems related to the modelling and simulation of physical performance of the unilateral external mechatronic orthopaedic fixator-bone system are presented. The majority of works makes use of the rigid finite element method for analysing the rthopaedic devicebone system. The paper presents some problems regarding mechanics applied in the external osteosynthesis design.
Stabilizacja zewnętrzna jest jedną z metod leczenia złamanych kończyn. Konstrukcja stabilizatorów zewnętrznych składa się z ramy nośnej umieszczonej po zewnętrznej stronie złamanej kończyny oraz wkrętów kostnych zamocowanych w odłamach złamanej kończyny i zablokowanych jednocześnie w ramie nośnej. Ideą konstrukcji stabilizatorów zewnętrznych jest "przenoszenie obciążenia" podczas procesu zrostu złamanych odłamów kostnych przez ramę nośną, a tym samym odciążenie szczeliny zrostu kostnego. W projektowaniu stabilizatorów nowej generacji wykorzystywane są wybrane zagadnienia mechaniki, które umożliwiają analizę układów biomechanicznych, takich jakim w prezentowanym artykule jest system stabilizator zewnętrzny-odłam kostny. Artykuł prezentuje zastosowanie wybranych zagadnień mechaniki w projektowaniu ortopedycznych stabilizatorów zewnętrznych nowej generacji.
Źródło:
Journal of Theoretical and Applied Mechanics; 2010, 48, 2; 453-463
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamic behavior of bone-implant substitute systems. Numerical and experimental study
Dynamika układów zastępczych połączenia kość-implant. Badania numeryczne i eksperymentalne
Autorzy:
Nowak, B.
Kaczmarek, M.
Kubik, J.
Powiązania:
https://bibliotekanauki.pl/articles/279424.pdf
Data publikacji:
2009
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
dynamics
biomechanics
bone
implant
Opis:
In this paper, a study of substitute systems of an implanted bone was presented from the point of view of elaboration of a method for dia- gnosing the state of integrity of the bone-implant attachment based on vibrational techniques. Dynamic parameters of the systems were esha- blished as sets of eigenfrequencies/resonance frequencies using numerical procedures and experimental modal analysis. The shifts of values of the parameters were discussed in relation to the loosening of contact between the bone and implant. The numerical and experimental results were compared and their consequences for application of vibrational techniques to real anatomical systems discussed.
W pracy przedstawiono badania układów zastępczych zaimplantowanej kości udowej, które dotyczą rozwijania nowych metod diagnostycznych opartych na technikach drganiowych. Wyznaczono zbiory parametrów dynamicznych układów w postaci częstotliwości własnych i rezonansowych dla badań numerycznych i eksperymentalnych. Zmiany parametrów dynamicznych przedyskutowane zostały w kontekście odspajania implantu od kości. Porównano także wyniki badań numerycznych i eksperymentalnych oraz przeanalizowano możliwości zastosowania tej metody w układach anatomicznych.
Źródło:
Journal of Theoretical and Applied Mechanics; 2009, 47, 3; 617-628
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Differences in Limb and Joint Stiffness during the Fencing Lunge
Autorzy:
Sinclair, Jonthan
Bottoms, Lindsay
Powiązania:
https://bibliotekanauki.pl/articles/1054734.pdf
Data publikacji:
2015
Wydawca:
Uniwersytet Szczeciński. Wydawnictwo Naukowe Uniwersytetu Szczecińskiego
Tematy:
biomechanics
fencing
limb stiffness
Opis:
The aim of the current investigation was to examine gender differences in limb and joint stiffness characteristics during the fencing lunge. Ten male and ten female fencers completed simulated lunge movements. Lower limb kinematics were collected using an eight camera optoelectric motion capture system which operated at 250 Hz. Measures of limb and joint stiffness were calculated as a function of limb length and joint moments divided by the extent of limb and joint excursion. Gender differences in limb joint stiffness parameters were examined statistically using independent samples t-tests. The results showed firstly that both limb (male = 64.22 ±19.12, female = 75.09 ±22.15 N.kg.m) and hip stiffness (male = 10.50 ±6.00, female = 25.89 ±15.01 Nm.kg.rad) were significantly greater in female fencers. In addition it was also demonstrated that knee moment (male = 1.64 ±0.23, female = 2.00 ±0.75 Nm.kg) was significantly larger in females. On the basis of these observations, the findings from the current investigation may provide further insight into the aetiology of the distinct injury patterns observed between genders in relation to fencing.
Źródło:
Central European Journal of Sport Sciences and Medicine; 2015, 11, 3; 39-44
2300-9705
2353-2807
Pojawia się w:
Central European Journal of Sport Sciences and Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biomechanical Assessment of Three Rebar Tying Techniques
Autorzy:
Albers, J. T.
Hudock, S. D.
Powiązania:
https://bibliotekanauki.pl/articles/90340.pdf
Data publikacji:
2007
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
construction
biomechanics
reinforcing ironwork
Opis:
The National Institute for Occupational Safety and Health (NIOSH) conducted a study of ironworkers to evaluate their risk for developing back and hand injuries from hand-tying reinforcing steel bar and to investigate whether power tying tools can be an effective intervention for the prevention of work-related musculoskeletal disorders. A field investigation of biomechanical loading when using 3 techniques to tie together rebar was conducted. Researchers measured employees’ wrist and forearm movement with goniometers and videotaped and analyzed trunk postures. Manually tying rebar at ground level involved sustained deep trunk bending and rapid, repetitive, and forceful hand–wrist and forearm movements. Using a power tier significantly reduced the hand–wrist and forearm movements and allowed the ironworkers to use one free hand to support their trunk posture while tying. Adding an extension handle to the power tier allowed the ironworkers to tie rebar while standing erect, minimizing sustained trunk flexion.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2007, 13, 3; 279-289
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Significance of Preventive Behaviour in the Context of a Correct Body Posture in Violin Students
Autorzy:
Kruszyńska-Szwedo, Joanna
Miller-Banaś, Anna
Guzik-Kopyto, Agata
Michnik, Robert
Powiązania:
https://bibliotekanauki.pl/articles/29520740.pdf
Data publikacji:
2024-03-31
Wydawca:
Wydawnictwo Adam Marszałek
Tematy:
musical education
violin
biomechanics
Opis:
One of the important elements of musical education is correct body posture and the ability to properlay use the motor organ to play. This work presented the possibility of applying biomechanical tests to support and enhance the education of playing instruments. The results showed that it is possible to perform such an assessment based on measurements of the body’s centre mass (COM) and loads exerted on the feet. The measurement data collected in this way enables quantitative evaluation of the body posture and the COM movement during the playing activity.
Źródło:
The New Educational Review; 2024, 75; 164-175
1732-6729
Pojawia się w:
The New Educational Review
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza biomechaniki kręgosłupa w jeździectwie
The analysis of spine biomechanics in equine sports in use of progressive measure technologies
Autorzy:
Szypielewicz, S.
Andryszczyk, M.
Siemianowski, P.
Topoliński, T.
Powiązania:
https://bibliotekanauki.pl/articles/99037.pdf
Data publikacji:
2017
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
biomechanika sportu
biomechanika kręgosłupa
sEMG
jeździectwo
sport biomechanics
spine biomechanics
equestrian sport
Opis:
Niniejsza praca przedstawia możliwości analizy motoryki jeźdźca podczas jazdy konnej oraz doskonalenia treningu jeździeckiego poprzez wykorzystanie pomiarów zmian kątów kręgosłupa oraz potencjałów elektrycznych mięśni pleców jeźdźca.
The following research shows the possibilities of motorics analysis of horse-rider in equine sports and improvement of equine training throughout using the progressive measure technologies. Researches includes EMG potential measures of back muscles and measures of angle changes between spine segments.
Źródło:
Aktualne Problemy Biomechaniki; 2017, 13; 57-62
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
What can normal gait biomechanics teach a designer of lower limb prostheses
Autorzy:
Pitkin, M.
Powiązania:
https://bibliotekanauki.pl/articles/306996.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
biomechanics
prosthetics
anthropomorphicity
biomechanika
protetyka
Opis:
Compensating a limb loss with prosthesis is a challenging task due to complexity of the human body which cannot be fully matched by the available technical means. Designer of lower limb prostheses wants to know what specification of the device could provide the best approximation to the normal locomotion. Deep understanding of the latter is essential, and gait analysis may be a valuable tool for this. Once prosthesis is built, gait analysis may help in comparing the wearer’s performance with the new device and with the prior art, and in verification of the hypotheses being put forward during the development process. In this lecture, we will discuss some synergies of normal gait. We will focus on the required biomechanical properties of a prosthetic leg that can allow the prosthesis’s inclusion in normal gait synergy without demanding excessive compensatory movements. We will consider contribution of leg joints to generation of propulsion for adequate design of lower limb prostheses especially those with power supply.
Źródło:
Acta of Bioengineering and Biomechanics; 2013, 15, 1; 3-10
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Finite element method in car compatibility phenomena
Autorzy:
Lisiecki, M.
Powiązania:
https://bibliotekanauki.pl/articles/246189.pdf
Data publikacji:
2010
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
compatibility
crash
biomechanics
simulation
transport
Opis:
The main aim of the study is the side impact of the truck into the passenger car, which is one of the possible variants in compatibility case. The compatibility problem has direct influence at biomechanical injuries of the passengers travelling by the cars and also at deformation of the structure. This research should assign critical configurations of the truck and the car during side impact. Critical criteria of compatibility problem are biomechanical injuries structure deformation. The research was performed with Chrysler Neon mode, automotive seating (metal construction), Hybrid III dummy model and moving barrier with changed mass (equals to the mass of the heavy truck KAMAZ) and equipped with front underrun protection barrier (FUP - based on the geometry of the Mercedes ACTROS front structure). Interaction between car and heavy truck is at the driver side. During the research different location and angles of the barrier against the car has been taken into account. Two speeds were used to investigate the barrier influence to the car. The results of the simulation allow predicting the biomechanical coefficients such as: HIC, 3 ms, TTI, e.g., which give the overview of the passenger injuries. The other set of the data is plastic deformations which are visible at the Front Underrun Protection (FUP) barrier and also at the passenger car construction. The results of research allows to assign the direction ofthe changes which should be proposed to the truck manufactures in order to reduce passengers biomechanical injuries and intrusion into car during side impact.
Źródło:
Journal of KONES; 2010, 17, 1; 241-247
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelling muscle force distributions during the front and back squat in trained lifters
Autorzy:
Sinclair, Jonathan
Atkins, Stephen
Hayley, Vincent
Richards, James D.
Powiązania:
https://bibliotekanauki.pl/articles/1054989.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Szczeciński. Wydawnictwo Naukowe Uniwersytetu Szczecińskiego
Tematy:
Biomechanics
resistance training
weight lifting
Opis:
The barbell squat is a fundamental strength and conditioning exercise, with two principal variants; back and front. Whilst previous studies have examined the mechanical differences of the front and back squat, there is no information comparing the distributions of muscle forces between these variants. This study aimed to compare estimated forces developed by the primary skeletal muscles used in the front and back squat. Twenty-five male participants were recruited with 6.24 ±2.21 years of experience in squat lifting and 1 repetition maximum values of 127.5 ±18.8 and 90.6 ±14.4 kg for the back and front squat lifts. Participants completed both back and front squats at 70% of their front squat 1 repetition maximum. Muscle forces were determined during dynamic situations using motion capture data, in addition to sagittal plane kinematics. Differences between squat conditions were examined using a multivariate analysis of variance. The kinematic analysis showed that the back squat was associated with significantly (p < 0.05) greater flexion of the trunk. Examination of muscles forces indicated that erector spinae forces were also significantly (p < 0.05) larger in the back squat. No significant differences were identified for skeletal muscle forces elsewhere (p > 0.05). Our results indicate that neither the front nor back squat provides any marked difference in muscle force production, aside from that isolated to the lower back. These findings lead the conclusion that neither the front nor back squat conditions confer any additional benefits over the other in terms of the skeletal muscle force output.
Źródło:
Central European Journal of Sport Sciences and Medicine; 2016, 14, 2; 13 - 20
2300-9705
2353-2807
Pojawia się w:
Central European Journal of Sport Sciences and Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Integrated Dynamometric, Kinematic And Electromyographic Characterisation Of A Swimming Track Start Block Phase – A Pilot Study
Autorzy:
Vitor, Manuel
de Jesus, Karla
Mourão, Luís
Tribuzi, Sara
Gonçalves, Pedro
Marques, Mariana
Roesler, Hélio
Vaz, Mário
Vilas-Boas, João Paulo
Fernandes, Ricardo J.
Powiązania:
https://bibliotekanauki.pl/articles/1054777.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Szczeciński. Wydawnictwo Naukowe Uniwersytetu Szczecińskiego
Tematy:
biomechanics
dynamometry
kinematics
electromyography
swimming
Opis:
This study presents a complete biomechanical analysis of the block phase of a swimming modified track start. Kinetic, kinematic and electromyography (EMG) data were collected. The forces produced by the swimmer on the block, the EMG of eight muscles and the kinematics of the centre of mass (CM) were recorded. A national-level swimmer performed three repetitions of a track start in a dynamometric starting block. Temporal instants ‘reaction time’, ‘hands take-off’, ‘rear foot take-off’ and ‘front foot take-off’ were identified. Results show the peak forces (Fmax) produced by the most dynamic limb in each sub-phase delimited by mentioned instants (right hand take-off: Fmaxvertical = 103 N; rear foot take-off: Fmaxantero-posterior = 524 N; front foot take-off: Fmaxvertical = 634 N). The CM revealed a descendent vertical trajectory along the block phase. Mean resultant speed at front foot take-off was 4.092m/s. The muscles with highest values of integral EMG (iEMG) were the tibialis anterior during hands take-off, Biceps Femoris and Gluteus Maximus during rear foot take-off, respectively 41.17%, 52.96% and 36.37% of the maximum isometric voluntary contraction (%MIVC). The study demonstrates an effective characterisation of the block phase in swimming starts with potential to evaluate the swimmers performance in the track start, using different back plate positioning.
Źródło:
Central European Journal of Sport Sciences and Medicine; 2016, 15, 3; 5-14
2300-9705
2353-2807
Pojawia się w:
Central European Journal of Sport Sciences and Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Finite element method in car compatibility phenomena
Autorzy:
Lisiecki, M.
Powiązania:
https://bibliotekanauki.pl/articles/247204.pdf
Data publikacji:
2011
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
compatibility
crash
biomechanics
simulation
transport
Opis:
The main aim of the study is the side impact of the truck into the passenger car, which is one of the possible variants in compatibility case. The compatibility problem has direct influence at biomechanical injuries of the passengers travelling by the cars and also at deformation of the structure. This research should assign critical configurations of the truck and the car during side impact. Critical criteria of compatibility problem are biomechanical injuries structure deformation. The research was performed with Chrysler Neon mode, automotive seating (metal construction), Hybrid III dummy model and moving barrier with changed mass (equals to the mass of the heavy truck KAMAZ) and equipped with front under run protection barrier (FUP - based on the geometry of the Mercedes ACTROS'front structure). Interaction between car and heavy truck is at the driver side. During the research different location and angles of the barrier against the car has been taken into account. Two speeds were used to investigate the barrier influence to the car. The results of the simulation allow predicting the biomechanical coefficients such as: HIC, 3ms, TTI, e.g., which give the overview of the passenger injuries. The other set of the data is plastic deformations which are visible at the Front Underrun Protection (FUP) barrier and also at the passenger car construction. The results of research allows to assign the direction of the changes which should be proposed to the truck manufactures in order to reduce passengers biomechanical injuries and intrusion into car during side impact.
Źródło:
Journal of KONES; 2011, 18, 4; 234-241
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Use of criminalistics and forensic sciences at ensuring the population security
Autorzy:
Porada, Viktor
Straus, Jiří
Powiązania:
https://bibliotekanauki.pl/articles/1878657.pdf
Data publikacji:
2014
Wydawca:
Wyższa Szkoła Bezpieczeństwa Publicznego i Indywidualnego Apeiron w Krakowie
Tematy:
criminalistics
forensic science
security
biomechanics
Opis:
In paper there are well-ordered given present directions of development forensic biomechanics. The author carried out the analysis of 100 expert opinions performed since 1994 in professional field “Criminalist, subject field forensic biomechanics” in cases that were concluded by court authority. According to analysis of needs of practice and expert investigations the author gives real prediction of further directions of research in forensic biomechanics. Forensic biomechanics invokes in investigation process, particularly violent criminal acts; by expert investigation it may come to conclusion on mechanisms of criminal act, action of extrinsic force and expression to consequences of this extrinsic force. Directions of development of forensic biomechanics are given by author in following applications - biomechanics of fall from high, judgment of extreme dynamic burden of organism, biomechanical analysis of fall from stand on a ground or fall from stairs, biomechanical analysis of walk and analysis of conflict combat. These directions represent 90% of all processed expert opinion.
Źródło:
Security Dimensions; 2014, 11(11); 106-114
2353-7000
Pojawia się w:
Security Dimensions
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Validity of an Inertial Measurement Unit System to Assess Lower-limb Kinematics during a Maximal Linear Deceleration
Autorzy:
Jordan, Alastair R.
Carson, Howie J.
Wilkie, Brett
Harper, Damian J.
Powiązania:
https://bibliotekanauki.pl/articles/1339723.pdf
Data publikacji:
2021
Wydawca:
Uniwersytet Szczeciński. Wydawnictwo Naukowe Uniwersytetu Szczecińskiego
Tematy:
biomechanics
braking
IMU
stopping
Xsens
Opis:
This study examined the validity of an inertial measurement unit system for measuring lower-limb joint kinematics during linear decelerations. A male team athlete (age 36 years, stature 1.75 m, mass 80.0 kg) performed multiple linear decelerations, following 20 m runs at 50%, 75% and 100% self-perceived effort. Inertial measurement unit sensors were strapped to lower-limb segments and retroreflective markers were adhered to the lower-limbs for 3D optical motion analysis. Ground contact time, foot to centre of mass displacement (foot-COM), peak and minimum angle, mean angular velocity and range of motion at the ankle, knee and hip during the contact phases of each deceleration were determined. Measures were valid if a very large correlation (r ≥ 0.7) and small bias (effect size < 0.6) were evident. Following 50% effort, ground contact time, foot-COM and most hip and knee kinematics were valid. Ground contact time, foot-COM and knee flexion velocity and range of motion were valid following 75% efforts. Ground contact time and knee flexion velocity were valid following 100% effort. Therefore, the inertial measurement unit system tested can be used to assess temporal-spatial parameters during a deceleration regardless of the preceding effort, and hip and knee kinematics following low intensity running.
Źródło:
Central European Journal of Sport Sciences and Medicine; 2021, 33, 1; 5-16
2300-9705
2353-2807
Pojawia się w:
Central European Journal of Sport Sciences and Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement of Angular Parameters and Velocities of the Upper Limb Segments in Tennis Using Inertial Motion Sensors for the Purposes of the Didactic Process
Autorzy:
WOŁOSZYN, FILIP
Powiązania:
https://bibliotekanauki.pl/articles/455647.pdf
Data publikacji:
2019
Wydawca:
Uniwersytet Rzeszowski
Tematy:
biomechanics
motioncaputre
IMU
tennis
didactics
Opis:
The aim of the study is to show differences in accurate and missed forehand and backhand strokes in tennis, as a feedback for coaches, teachers and players. The main assumptions of the study are to show the values of angular parameters and velocity, as well as to analyse every phase of a stroke. The priority in the study is to show how the abovementioned parameters affect the accuracy and velocity of forehand and backhand strokes. Material and research methods: A professional tennis player was tested using the individual case method and kinematic analysis. The motion capture system (MCS) was used for research purposes using inertial motion sensors. Results: Strokes were analysed to demonstrate the angular parameters and velocities of selected upper limb segments. Three upper limb segments were taken into account, i.e. the right hand, the right forearm and the right shoulder. The results of the angles and velocities achieved by individual segments were analysed in three axes of the body: X, Y, Z. The results concern the beginning of the acceleration phase, the end of the acceleration phase, i.e. the moment of impact, and the final, follow-through phase. Conclusion: The results show that a stroke can be accurate despite a significant change in angle and velocity. This situation applies to both forehand and backhand strokes.
Źródło:
Edukacja-Technika-Informatyka; 2019, 10, 1; 302-309
2080-9069
Pojawia się w:
Edukacja-Technika-Informatyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nanostructured bone-like scaffolds for restoration of trabecular bone remodeling capability
Autorzy:
Nowak, M.
Firkowska, I.
Giersig, M.
Powiązania:
https://bibliotekanauki.pl/articles/202376.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
bone remodeling
biomechanics
nanostructured scaffolds
Opis:
This paper presents the theoretical study about carbon nanotube substrates for tissue engineering and its applications. Because the replacement of bone tissue with artificial tissue can violate the remodeling process completely, the artificial material should not only consist of the same material properties, but also exhibit other characteristics which are equally important and need to be taken into consideration. These are above all the mechanosensation. Besides replacing natural tissue, the nanostructured scaffolds presented in the paper can help the tissue growth by stimulating this process. The developed trabecular bone remodeling simulation method responsible for the nanostructured scaffold behavior is implemented here. Thus, the nanostructured bone-like scaffolds reflect the remodeling capability of the biological system, not only due to their application as replacement of natural tissue, but also due to their effects in the field of mechanosensation.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2011, 59, 1; 57-61
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Upper limb analysis measured by inertial measurement unit tool: a case report
Autorzy:
Wołoszyn, Filip
Czmi, Anna
Powiązania:
https://bibliotekanauki.pl/articles/454678.pdf
Data publikacji:
2019
Wydawca:
Uniwersytet Rzeszowski. Wydawnictwo Uniwersytetu Rzeszowskiego
Tematy:
biomechanics
IM
tenni
timing
upper limb
Opis:
Introduction. This article reports differences in accurate and inaccurate forehand and backhand strokes in tennis. The tests were carried out on a professional tennis player. The duration of a stroke, the heights of the individual segments of the right upper limb and differences in the heights of the segments at the beginning and at the end of every phase of stroke were examined. Aim. The major aim of the work was to expose upper limb disparity in stokes. Description of the case report. The research tool was inertial motion sensors (IMS) based on an accelerometer, a gyroscope and a magnetometer. A professional tennis player was examined using the individual case method and kinematic analysis. Results. The analysis concerned the average time to perform forehand and backhand strokes during all phases of the stroke, i.e. preparation, acceleration and follow-through phases. The average heights of the individual upper limb segments during a stroke were also taken into account. The results of the study are meant to show how the movement of the upper limb affects the accuracy and velocity of a stroke. Conclusion. The movements of individual segments in some accurate strokes were similar to those in inaccurate strokes.
Źródło:
European Journal of Clinical and Experimental Medicine; 2019, 1; 94-100
2544-2406
2544-1361
Pojawia się w:
European Journal of Clinical and Experimental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The structural and mechanical properties of the bone
Budowa i własności mechaniczne tkanki kostnej
Autorzy:
Karpiński, R.
Jaworski, Ł.
Czubacka, P.
Powiązania:
https://bibliotekanauki.pl/articles/101784.pdf
Data publikacji:
2017
Wydawca:
Politechnika Lubelska. Polskie Towarzystwo Promocji Wiedzy
Tematy:
bones
biomechanics
cartilage
kości
biomechanika
chrząstki
Opis:
The work contains basic information on the anatomy and physiology of bone tissue. Basic concepts related to the structure of bone tissue are presented. General issues related to bone reconstruction processes and biomechanical structural adaptations processes were described. Mechanical parameters of bone tissue were presented.
Praca zawiera podstawowe informacje z zakresu anatomii i fizjologii tkanki kostnej. Przedstawiono podstawowe pojęcia związane ze strukturą tkanki kostnej. Opisano podstawowe zagadnienia związane z procesami przebudowy tkanki kostnej oraz biomechaniczne procesy dostosowawcze. Zaprezentowano parametry mechaniczne tkanki kostnej.
Źródło:
Journal of Technology and Exploitation in Mechanical Engineering; 2017, 3, 1; 43-51
2451-148X
Pojawia się w:
Journal of Technology and Exploitation in Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
BIomechanical aspects of artificial joint implantation in a lower limb
Autorzy:
Będziński, R.
Bernakiewicz, M.
Ścigała, K.
Powiązania:
https://bibliotekanauki.pl/articles/280285.pdf
Data publikacji:
1999
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
biomechanics
implantation
hip joint
knee joint
Opis:
One of the most important trends in engineering biomechanics is experimental and numerical analysis of the stress and strain state existing in organs subject to a heavy load; e.g., the knee and hip joints. Clinical tests experimental and numerical studies on design of implants replacing damaged organs are also of crucial importance in development of biomechanics. The research is focused on determination of loads, experimental techniques as well as on simplifications assumed in measurements and applied models. The conducted investigations were concerned with estimation of mechanical behaviour of hip and knee implants after arthoplasty. The experimental tests on both the real objects and models were performed. Numerical simulation was made by using the finite element method. The tests have proved that from the biomechanical point of view proper selection of endoprothesis is of crucial importance for achieving positive long-term results of alloplasty.
Jednym z najważniejszych kierunków badań w dziedzinie biomechaniki inżynierskiej jest doświadczalna i numeryczna analiza stanu odkształceń i naprężeń w organach ludzkich poddanych znacznym obciążeniom, jak chociażby staw biodrowy i kolanowy. Badania kliniczne, doświadczalne i numeryczne poświęcone konstrukcji elementów zastępujących uszkodzone elementy ciała ludzkiego stanowią jeden z najważniejszych kierunków biomechaniki. Dyskusje na tym tle skoncentrowane są na problemach beterminacji występującego stanu obciążenia, stosowanych technik pomiarowych oraz uproszczeń warunków pomiaru i przyjmowanych modeli. Przeprowadzone badania poświęcone zostały ocenie mechanicznej współpracy sztucznych elementów stawu biodrowego i kolanowego w warunkach modelowych, jak i metodą symulacji numerycznej, metodą elementów skończonych. Badania udowodniły duże znaczenie prawidłowej selekcji endoprotez z punktu widzenia biomechaniki układu na długoterminowe powodzenie alloplastyk.
Źródło:
Journal of Theoretical and Applied Mechanics; 1999, 3; 455-479
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical investigation of a new type of artificial lumbar disc
Komputerowo wspomagane projektowanie nowego typu protezy krążka międzykręgowego
Autorzy:
Borkowski, P.
Kędzior, K.
Krzesiński, G.
Skalski, K. R.
Wymysłowski, P.
Zagrajek, T.
Powiązania:
https://bibliotekanauki.pl/articles/282071.pdf
Data publikacji:
2004
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
spine biomechanics
implants
FEM
disc prosthesis
Opis:
The replacement of a damaged lumbar disc by an artificial organ is still not satisfactorily solved problem of surgery. In the study, the finite element method together with CAD programs and experimental validation was used in investigations of a new type of artificial disc for lumbar spine. The present 3D parametrical FE models take into account nonhomogenous properties of tissues, contact with friction between the parts of the analysed systems, large strains and large displacements. The stress analyses were performed for the prostheses being in clinical use and for some new designs. The conclusions concern most important determinants of the mechanical quality of the intervertebral disc prosthesis.
Zastąpienie lędźwiowego krążka miedzykręgowego przez protezę jest wciąż nie w pełni rozwiązanym problemem chirurgii. W pracy zastosowano metodę elementów skończonych, techniki CAD oraz metody weryfikacji eksperymentalnej do poszukiwania konstrukcji nowego typu sztucznego krążka dla odcinka lędźwiowego kręgosłupa. Prezentowane modele metody elementów skończonych uwzględniają niejednorodne właściwości tkanek, występowanie dużych deformacji oraz oddziaływania między poszczególnymi częściami analizowanej struktury. Analizy przeprowadzono dla protez stosowanych obecnie w praktyce klinicznej oraz dla kilku nowych propozycji konstrukcji. Wnioski dotyczą najważniejszych czynników o charakterze mechanicznym, które wpływają na jakość sztucznych krążków międzykręgowych.
Źródło:
Journal of Theoretical and Applied Mechanics; 2004, 42, 2; 253-268
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The impact of the safety belt used for chairs used in buses and minibuses with small-speed collisions
Autorzy:
Jaśkiewicz, M.
Więckowski, D.
Powiązania:
https://bibliotekanauki.pl/articles/906239.pdf
Data publikacji:
2014
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
safety belts
collisions
biomechanics of injuries
Opis:
The article presents the analysis of the impact of the safety belt used onto a man sitting in a chair. The tests were conducted for small-speed collisions for three centile groups: 5, 50 and 95-centile group respectively. Each of those groups comprised men between 20 to 35 years of age. The tests were conducted on the inclined plane type device simulating the collision of a vehicle with the speed of approx. 12 km/h. Three types of safety belts were used for the tests: two-point, three-point and four-point belts. The results of analyses are presented in this article.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2014, 39 (111); 74-81
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hip joint implants - survey of numerical modeling
Autorzy:
Bajer, C.
Małdyk, P.
Kowalczewski, J.
Powiązania:
https://bibliotekanauki.pl/articles/280281.pdf
Data publikacji:
1999
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
biomechanics
hip joints
numerical modeling
FEM
Opis:
In the paper the discussion of the modeling of hip joint implants is presented. the historical attempts to implant construction finally led to complex solutions. To date almost all experiences have learned from clinic observation and rather tests and trial methods than systematic research. Numerical simulations have been limited to simple stress analysis. All phenomena responsible for the damage in the treated joint are not fully explained. The comlexity of the problem is presented in the paper. The stress concentration in the region of rigid inclusion is pointed as one of the mechanical destructive factors. The change of the stem form and material rigidity cuuld reduce extremal stresses by 10-20%.
W pracy omówiono modelowanie implantów stawu biodrowego. Historyczne próby ich konstruowania doprowadziły do bardzo złożonych rozwiązań. Dotąd niemal wszystkie doświadczenia zdobywano w obserwacjach klinicznych i próbach, a nie w wyniku systematycznych badań. Numeryczne symulacje ograniczono do prostej analizy stanu naprężenia. Większość zjawisk odpowiedzialnych za uszkodzenia badanych stawów nie jest w pełni wyjaśniona. W pracy zwrócono uwagę na złożoność zagadnienia. Za jeden z czynników niszczących uznano koncentracje naprężeń w strefach sztywnych wtrąceń. Zmiana kształtu trzpienia i sztywności materiału pozwala zmniejszyć ekstremalne naprężenia o 10-20%.
Źródło:
Journal of Theoretical and Applied Mechanics; 1999, 3; 435-454
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Amphibious-like minirobot
Minirobot naśladujący płaza ziemnowodnego
Autorzy:
Bodnicki, M.
Sęklewski, M.
Grzelak, R.
Powiązania:
https://bibliotekanauki.pl/articles/159287.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
nauczanie
mikrorobot
biomechanika
education
microrobot
biomechanics
Opis:
A subject of presented work ware design and building a prototype of microrobot, which can imitate behavior of an amphibian, (e.g. salamander). Robot, which has been built, generates both types of the amphibian movement: walk on four legs and imitation of the swimming gait. Modular structure is one of its features, and constructed modules are fully interchangeable. The commercial DC servos controlled by microprocessor unit were used as actuators (for leg and thorax movement). The master software is installed in PC microcomputer. Operator controls main parameters of the movement (straight on or turn) and sequences of commands for servos are generated automatically.
Większość praktycznie wykorzystywanych robotów mobilnych porusza się na kołach lub gąsienicach. Rozwijany jest jednak także wątek mikrorobotów naśladujących naturalne (występujące w przyrodzie) formy ruchu – chód, pełzanie lub pływanie na wzór zwierząt żyjących w środowisku wodnym. Praca [7] przedstawia szeroko problematykę robotów kroczących, w tym bezpośrednio inspirowanych przez organizmy żywe. Bezpośrednią inspiracja autorów były prace grupy badawczej BIRG [8], w szczególności przedstawiające analizę mechanizmów ruchu płazów ziemnowodnych (rodzina salamandrowate) i opis matematyczny sposobu generacji chodu i pływania [1, 3-5]. Z wyżej wymienionych prac zaczerpnięto wzory (1-3), zaimplementowane następnie w opracowanym urządzeniu. Opracowany minirobot ma strukturę modułową. Jego ciało składa się z głowy, korpusu i ogona oraz czterech łap. Struktura całego systemu jest przedstawiona na rysunku 1. Konstrukcja mechaniczna składa się z dwóch typów modułów. Modułem bazowym jest tzw. segment A będący elementem korpusu urządzenia. Moduł ten może skręcać się względem elementu poprzedzającego (następującego) – rys. 1. Na bazie tego rozwiązania skonstruowano moduł osadzenia łap (moduł B), którego kinematyka umożliwia dodatkowo unoszenie łap oraz ich składanie przy zmianie trybu ruchu od chodu do pływania (przy czym konstrukcja prototypu nie jest jednak przystosowana do pracy w środowisku wodnym). Siłownikami są popularne modelarskie serwomechanizmy prądu stałego, sterowane za pośrednictwem specjalizowanego układu SK18 (z wykorzystaniem techniki PWM) z mikrokomputera PC – poprzez złącze RS232. Nadrzędny program sterujący jest zaimplementowany w mikrokomputerze PC. Panel główny programu przedstawiono na rysunku 2. Poszczególne przyciski panelu umożliwiają zmianę trybu ruchu, zmianę parametrów chodu lub "pływania" (np. szybkości lub promienia skrętu). Prowadzona jest również bieżąca wizualizacja układu ciała "salamandry". Główne algorytmy pracy urządzenia podano w pozycji literaturowej [2]. Robot może być zasilany z akumulatorów wbudowanych w poszczególne modułu, jednak w bieżącej fazie prac zdecydowano się na zmniejszenie masy (i autonomiczności) poprzez zastosowanie zasilania za pośrednictwem przewodów. Projektowanie struktury wykonawczej rozpoczęto od opracowania modeli trójwymiarowych (rys. 3). Umożliwiły one analizę zachowania robota w różnych warunkach oraz wygenerowanie dokumentacji konstrukcyjnej prototypu. Zbudowano następnie dwie wersje prototypu (różniące się wielkością i momentem serwomechanizmów. Zdjęcia prototypu przedstawia rysunku 4. Urządzenie zostało uruchomione i przetestowane. Obecnie trwają prace związane z zabudową sieci czujników (w tym mikrokamery wideo).
Źródło:
Prace Instytutu Elektrotechniki; 2009, 240; 9-17
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Countermovement depth – a variable which clarifies the relationship between the maximum power output and height of a vertical jump
Autorzy:
Gajewski, J.
Michalski, R.
Buśko, K.
Mazur-Różycka, J.
Staniak, Z.
Powiązania:
https://bibliotekanauki.pl/articles/306825.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
ćwiczenia
biomechanika
alometria
exercise
biomechanics
regression
allometry
Opis:
The aim of this study was to identify the determinants of peak power achieved during vertical jumps in order to clarify relationship between the height of jump and the ability to exert maximum power. Methods: One hundred young (16.8±1.8 years) sportsmen participated in the study (body height 1.861 ± 0.109 m, body weight 80.3 ± 9.2 kg). Each participant performed three jump tests: countermovement jump (CMJ), akimbo countermovement jump (ACMJ), and spike jump (SPJ). A force plate was used to measure ground reaction force and to determine peak power output. The following explanatory variables were included in the model: jump height, body mass, and the lowering of the centre of mass before launch (countermovement depth). A model was created using multiple regression analysis and allometric scaling. Results: The model was used to calculate the expected power value for each participant, which correlated strongly with real values. The value of the coefficient of determination R2 equalled 0.89, 0.90 and 0.98, respectively, for the CMJ, ACMJ, and SPJ jumps. The countermovement depth proved to be a variable strongly affecting the maximum power of jump. If the countermovement depth remains constant, the relative peak power is a simple function of jump height. Conclusions: The results suggest that the jump height of an individual is an exact indicator of their ability to produce maximum power. The presented model has a potential to be utilized under field condition for estimating the maximum power output of vertical jumps.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 1; 127-134
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Parallel mesh generator for biomechanical purpose
Autorzy:
Hausa, H.
Nowak, M.
Powiązania:
https://bibliotekanauki.pl/articles/279979.pdf
Data publikacji:
2014
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
parallel processing
finite element mesh generator
biomechanics
Opis:
The analysis of a biological structure with numerical methods based on engineering approach (i.e. Computational Solid Mechanics) is becoming more and more popular nowadays. The examination of complex, well reproduced biological structures (i.e. bone) is impossible to perform with a single workstation. The mesh for Finite Element Method (FEM) of the order of 106 is required for modeling a small piece of trabecular bone. The homogenization techniques could be used to solve this problem, but these methods require several assumptions and simplifications. Hence, effective analysis of a biological structure in a parallel environment is desirable. The software for structure simulation at cluster architecture are available; however, FEM generator is still inaccessible in that environment. The mesh generator for biological applications – Cosmoprojector – developed at Division of Virtual Engineering, Poznan University of Technology has been adapted for the parallel environment. The preliminary results of complex structure generation confirm the correctness of the proposed method. In this paper, the algorithm of computational mesh generation in a parallel environment has been presented. The proposed system has been tested at biological structure.
Źródło:
Journal of Theoretical and Applied Mechanics; 2014, 52, 1; 71-80
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A preliminary study on the optimal choice of an implant and its orientation in ventral hernia repair
Autorzy:
Lubowiecka, I.
Szepietowska, K.
Szymczak, C.
Tomaszewska, A.
Powiązania:
https://bibliotekanauki.pl/articles/281053.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
biomechanics
surgical mesh
finite element modelling
optimisation
Opis:
This paper addresses the problem of ventral hernia repair. The main goals are to find an optimal surgical mesh for hernia repair and to define its optimal orientation in the abdominal wall to minimise the maximum force at the tissue-implant juncture. The optimal mesh is chosen from a set of orthotropic meshes with different stiffness ratios for typical hernia placement in the abdominal area. The implant is subjected to an anisotropic displacement field, different for the selected hernia placements. The assumed displacement fields correspond to regular human activity. Proper implantation of the mesh may determine the success of hernia repair and/or the postoperative comfort of patients. The proposed solution is based on FEM simulations of different surgical meshes behaviour. In typical hernia placements, the optimal orientation of the stiffer direction of the implant is perpendicular to the spine. However, the presented results show some cases that an oblique direction may be the optimum one.
Źródło:
Journal of Theoretical and Applied Mechanics; 2016, 54, 2; 411-421
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies