Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "biodegradable implants" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Degradation Characterization and Mechanisms of Warm Rolled Mg-1.6Gd with 95% Reduction Ratio for Biodegradable Implant Applications
Autorzy:
Zakiyuddin, Ahmad
Irawan, Arya Abietta
Susanti, Oknovia
Harjanto, Sri
Powiązania:
https://bibliotekanauki.pl/articles/356740.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
biodegradable implants
Mg-1.6Gd
warm rolling
Mg-RE
EIS
Opis:
Mg-1.6Gd binary alloy was subjected to uniaxial warm rolling at a unidirectional and cross-sectional with a reduction ratio of 95% in order to observe the relationship between its microstructural changes to the degradation behavior. The warm rolling was performed at a temperature range of its recrystallization temperature, which were 400°C and 560°C, and a feed rate of 10 mm/min. Degradation behaviors of Mg-1.6Gd binary alloy was evaluated by means of potentiodynamic polarization and hydrogen evolution test in modified Kokubo’s SBF solution at temperature of 37 ± 1ºC. The lowest corrosion rate of 0.126 mm/year derived from potentiodynamic polarization test was showed by unidirectional-rolled specimen at temperature of 560°C. Hydrogen evolution test results showed the lowest hydrogen gas formed during 24 hours of immersion was found on unidirectional-rolled specimen at temperature of 560°C with a rate of 0.268 cc/cm2/hours. While cross rolled specimens showed a high corrosion and hydrogen evolution rate of 20 mm/year and 0.28 cc/cm2/hours.
Źródło:
Archives of Metallurgy and Materials; 2020, 65, 3; 1015-1018
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowe biodegradowalne pierścienie do zespalania jelita grubego
New biodegradable rings for large intestine integration
Autorzy:
Drop, R.
Mazurkiewicz, S.
Szaraniec, B.
Woźny, Z.
Gryń, K.
Cygan, R.
Powiązania:
https://bibliotekanauki.pl/articles/285186.pdf
Data publikacji:
2013
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
implanty
biomateriały
pierścienie zespalające
implants
biomaterials
biodegradable rings
Opis:
Próby łączenia jelit za pomocą implantów sięgają początków XIX w, kiedy to opracowane zostały pierwsze pierścienie zespalające przez Denansa (1827) i Henroza (1826). Kolejna konstrukcja zaproponowana przez Murphyego, tzw. guzik Murphyego, stała się inspiracją dla komercyjnych implantów, ulegających fragmentacji pierścieni Valtrac® (Biofragmentable Anastomotic Ring) do zespoleń jelitowych, których produkcję w latach osiemdziesiątych XX wieku rozpoczęła firma Davis & Geck. Równocześnie rozwijane były techniki zespalania jelit za pomocą staplerów (Hültl 1908, Petz 1924, Androsov 1950), które również w latach osiemdziesiątych XX wieku stały się jednym ze standardów postępowania w chirurgii jelita grubego. Prace nad opracowaniem skutecznego, łatwego w aplikacji i ulegającego w pełni biodegradacji implantu do zespoleń jelit nadal trwają. Zakładają one dążenie do możliwie najmniejszego uszkodzenia tkanek, zapewnienia szczelności zespolenia i odpowiedniej wielkości jego światła, przy zachowaniu prawidłowego ukrwienia i niewywoływaniu nadmiernego napięcia w jelitach. Jedną z propozycji nowoczesnego rozwiązania problemu związanego z zespalaniem jelita grubego może stanowić w pełni biodegradowalny układ pierścieni wykonany z poliestrów alifatycznych mocowanych bezszwowo. Aplikacja pierścieni zakłada odwinięcie zespalanych części jelita na zewnątrz jego światła, a następnie ich połączenie przez docisk dzięki odpowiedniemu systemowi blokującemu. Prototypy implantów do zespalania jelit otrzymano metodą wtrysku przy użyciu wtryskarki ślimakowej Multiplas. Temperatura wtrysku wynosiła 160-170°C, a ciśnienie w układzie 60-90 kg/cm2. Prototypy implantów wykonano z polimeru resorbowalnego - polilaktydu PLA firmy NatureWork, USA (PLA Ingeo 3251D). Pierwsze doświadczenia prowadzone in vitro i in vivo wskazują, że wykonane implanty mogą z powodzeniem spełniać wspomniane powyżej założenia i dodatkowo dzięki łatwej aplikacji znacznie skrócić czas trwania operacji. Zaproponowana konstrukcja układu pierścieni oraz właściwości fizyko-mechaniczne zastosowanego materiału polimerowego pozwoliły w prosty sposób zespolić jelito uzyskując jednakowy regulowany docisk na jego obwodzie.
The attempts at integrating intestines by means of implants date back to the beginning of the 19th century, when integrating rings were developed by Denans (1827) and Henroz (1826). Another construction, proposed by Murphy, the, so called, Murphy’s button, became an inspiration for commercial implants – the Valtrac® fragmentable rings (Biofragmentable Anastomotic Rings) for intestine integration, whose production was initiated in 1980s by Davis & Geck. Simultaneously developed were techniques of intestine integration with the use of staplers (Hültl 1908, Petz 1924, Androsov 1950), which, also in the 1980s, became one of the standards for large intestine surgery procedures. Works on the development of an effective, easily applicable and fully biodegradable implant for intestine integration are still being conducted. The main goal, providing a minimal tissue damages, is to obtain a leakproof anastomosis with a proper size of its inner diameter along with the preservation of the adequate blood supply and no excessive tensions in the intestines. One of the proposals of a modern solution to the problem connected with large intestine integration can be a fully biodegradable system of rings made of seamless-mounted aliphatic polyesters. The applying procedure assumes turning parts of the intestine, which are meant to be integrated, inside-out and stretching their edges on the rings. Next, rings are joined together by pressing them “face to face” and locking with the appropriate seamless blocking system. Prototypes of large intestine integration implants were obtained by the injection moulding (screw injection moulding machine Multiplas). The injection temperature was 160-170°C and the pressure in the system was 60-90 kg/cm2. The implant prototypes were prepared from a polymer – the PLA polylactide by NatureWork, USA (PLA Ingeo 3251D). The initial in vitro and in vivo experiments show that the elaborated implants can successfully meet the above mentioned assumptions and, additionally, because of their easy application, significantly shorten the time of the surgical procedure. The proposed construction of the ring system and the physico-mechanical properties of the applied polymer material made it possible to easily integrate the intestine and achieve a similar, regulated, pressure on its circumference.
Źródło:
Engineering of Biomaterials; 2013, 16, no. 122-123 spec. iss.; 56-57
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie działania antybakteryjnego kompozytów na bazie poli(L-laktydu) przeznaczonych na biodegradowalne gwoździe śródszpikowe
Antibacterial activity study of poly(L-lactide) composites for novel biodegradable intramedullary nails
Autorzy:
Domalik-Pyzik, P.
Morawska-Chochół, A.
Rzewuska, M.
Szaraniec, B.
Chłopek, J.
Powiązania:
https://bibliotekanauki.pl/articles/283976.pdf
Data publikacji:
2015
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
działanie antybakteryjne
biodegradowalne kompozyty
implanty dla ortopedii
polilaktyd
antibacterial activity
biodegradable composites
orthopaedic implants
polylactide
Opis:
Implantacja gwoździ śródszpikowych wiąże się z ryzykiem wystąpienia poważnej infekcji kości spowodowanej zakażeniem bakteryjnym. Tradycyjna antybiotykoterapia w tym przypadku ma wiele ograniczeń. Rozwiązaniem tego problemu może być lokalne dostarczanie leku bezpośrednio do miejsca implantacji. Jednym ze sposobów na realizację takiego rozwiązania jest stosowanie pokryć tradycyjnych gwoździ metalowych pokrytych degradowalnym materiałem polimerowym pozwalającym na kontrolowane uwalnianie substancji leczniczej. Autorzy poszli o krok dalej proponując wytworzenie nowatorskich gwoździ śródszpikowych z materiału degradowalnego, któremu nadano właściwości antybakteryjne poprzez wprowadzenie do resorbowalnej matrycy polimerowej antybiotyku w postaci siarczanu gentamycyny (GS). Dodatkowo osnowę z poli(L-laktydu) (PLA) zmodyfikowano wprowadzając druty ze stopów magnezu (MG), włókna węglowe (CF), włókna alginianowe (ALG) oraz nanocząstki fosforanu trójwapnia (TCP) w różnych układach. Test aktywności antybakteryjnej przeprowadzono z użyciem szczepu metycilino-wrażliwego Staphylococcus pseudintermedius. Dokonano analizy ilościowej i jakościowej stref zahamowania wzrostu bakterii utworzonych wokół badanych fragmentów gwoździ. Wykazano, że wszystkie zaproponowane materiały kompozytowe z dodatkiem gentamycyny wykazują działanie hamujące wzrost i namnażanie bakterii, najsilniejsze w przypadku układów PLA/CF/ ALG/GS oraz PLA/CF/ALG/TCP/GS. Działanie to utrzymuje się nawet po 12 dniach od pierwszego wysiewu. Ponadto badania wykazały, że gwóźdź PLA/MG również wykazuje słabe oddziaływanie antybakteryjne pomimo braku dodatku w postaci antybiotyku, jednak działanie to zostaje zablokowane po wprowadzeniu TCP do matrycy polimerowej.
Intramedullary nails implantation carries a risk of a serious bone infection caused by bacteria. In this case traditional antibiotic therapy has many limitations. A good solution to the problem can be local drug delivery directly to the implantation site. One of the ways to implement such solution is to use, on the surface of traditional metallic nails, degradable polymer coatings that enable controlled drug release. Authors went a step further by proposing to fabricate novel intramedullary nails entirely from degradable material that has been endowed with antibacterial properties. Antibacterial protection was provided by the introduction of an antibiotic - gentamicin sulphate (GS) to the poly(L-lactide) (PLA) matrix. Into the resorbable matrix the following modifying phases were also introduced: magnesium alloy wires (MG), carbon fibers (CF), alginate fibers (ALG) and tricalcium phosphate nanoparticles (TCP), in various systems. Antibacterial activity test was carried out using methicillin-sensitive strain Staphylococcus pseudintermedius. Qualitative and quantitative analysis of bacteria growth inhibition zones formed around studied nails’ samples were performed. It has been proven that all of the proposed composite materials with gentamicin addition showed inhibitory effect on growth and proliferation of bacteria, with the strongest in the case of PLA/CF/ALG/GS and PLA/CF/ALG/TCP/GS systems. The inhibitory effect was maintained even after 12 days since the first inoculation. Moreover, the study proved that PLA/MG nails also showed some antibacterial activity, despite lack of the antibiotic addition. However, after introduction of TCP to the matrix, this action has been blocked.
Źródło:
Engineering of Biomaterials; 2015, 18, 133; 7-13
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies