Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "base flow" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
Assessment of the SWAT Model and the Parameters Affecting the Flow Simulation in the Watershed of Oued Laou (Northern Morocco)
Autorzy:
Aqnouy, Mourad
El Messari, Jamal Eddine Stitou
Ismail, Hilal
Bouadila, Abdelmounim
Moreno Navarro, Jesús Gabriel
Loubna, Bounab
Mansour, Mohammed Reda Aoulad
Powiązania:
https://bibliotekanauki.pl/articles/125375.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
SWAT
flow
Laou watershed
sub-humid
semi-arid
base flow
Opis:
This study evaluated the Soil and Water Assessment Tool (SWAT) model performance for modeling the portioning of rainfall in the Laou watershed (area: 940 km2) that extended over two different climatic settings in Morocco, (the Mediterranean sub-humid and the semi-arid). This research also investigated the significant parameters that affect the stream flow simulation. SWAT model was constructed during the period from 2004 to 2011. The modeled stream flow data was manually calibrated using flow gauges daily from 2004 to 2008 and validated for the volumetric flows from 2009 to 2011. SWAT model results indicate that 60% of the stream is provided by the base flow. The sensitivity analysis showed that out of 28 parameters, only 6 revealed meaningful effects on the flow simulation (CN2, ESCO, SOL_AWC, ALPHA_BF, CH_N2, CH_k2) and have the most significant influence. The model proved to be very sensitive to the base flow. Furthermore our outcome indicates that SWAT can successfully replicate the daily stream flows in Laou watershed with Nash-Sutcliffe (NSE) coefficients in the range of 0.76–0.84, R2 of 0.74–0.82, RSR of 0.52–0.41 and PBIS of 12.24–8.93 respectively. In addition SWAT was found to be suitable for both climatic regions in Laou watershed. These results reinforced the multi-functionality and reliability of SWAT as a hydrological model and a relevant tool for water resources management and controls.
Źródło:
Journal of Ecological Engineering; 2019, 20, 4; 104-113
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Podziemny odpływ jednostkowy w Bieszczadach Wysokich
Specific base flow in the High Bieszczady Mountains
Autorzy:
Plenzler, J.
Bajorek, J.
Jaśkowiec, B.
Kołodziej, A.
Rzonca, B.
Siwek, J.
Wójcik, S.
Powiązania:
https://bibliotekanauki.pl/articles/2074754.pdf
Data publikacji:
2010
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
podziemny odpływ jednostkowy
Bieszczady Wysokie
specific base flow
High Bieszczady Mts.
Opis:
The paper presents spatial distribution of base flow in the High Bieszczady Mts. (the Outer Carpathians). Discharges in 30 investigated catchments were measured in October 2009 during low flow period. Differences observed in unit base flow were varying from 0.9 dm>sup>3 s-1 km-2 in the Niedźwiedzi catchment to 6.8 dm3 s-1 km-2 in the Hulski catchment. Occurrence of colluviums is conducive to high values of base flow. On the other hand, low values of base flow are common to catchments drained by short and shallow streams. Correlations between unit base flow and stream density, altitude or geological unit were not proved.
Źródło:
Przegląd Geologiczny; 2010, 58, 12; 1147-1151
0033-2151
Pojawia się w:
Przegląd Geologiczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of the impact of small bridges on the ditch capacity of the drainage system
Ocena wpływu oddziaływania małych mostów na przepustowość rowu systemu odwadniającego
Autorzy:
Michalec, Bogusław
Lubowicz, Stanisław
Powiązania:
https://bibliotekanauki.pl/articles/1429483.pdf
Data publikacji:
2020
Wydawca:
Uniwersytet Rolniczy im. Hugona Kołłątaja w Krakowie
Tematy:
damming
small bridge
base flow
drainage system
spiętrzenie
mały most
przepływ miarodajny
przepustowość
system melioracyjny
Opis:
The objective of the present study was to determine the impact of two small bridges located within the main ‘R’ ditch of the Łączany drainage system on the capacity of the selected fragment of this ditch. A fragment of the ‘R’ ditch was selected for the study, 311.7 m long, with two small bridges (bridge No. 1 at km 3 + 455 and bridge No. 2 at km 3 + 365) and 11 crosssections. Having conducted hydraulic calculations, the capacity of the selected fragment of the ditch was ascertained, assuming the base flow (reliable discharge) determined in the detailed design of the drainage system. The base flow, amounting to 9.77 m3 ∙ s–1, was also used to determine water damming in the examined bridges in accordance with the Regulation by the Minister of Transport and Maritime Economy. As a result of geodetic measurements, changes in the shape of the cross-sections of the ditch and changes to the bottom slope within the tested segment of the ditch were found. It was established that under the conditions of proper maintenance of the ditch, its capacity is not lower than the base flow. However, if the maintenance is neglected, the area before bridge No. 1 will be flooded, which is the result of the lowered capacity of the ditch. It was also found that the examined bridges did not contribute to the deterioration of the conditions of the base flow water through the ditch in the analysed fragment thereof.
Celem pracy było określenie wpływu dwóch małych mostów na głównym rowie „R” systemu odwadniającego Łączany na przepustowość wytypowanego fragmentu tego rowu. Do badań wytypowano fragment rowu „R” o długości 311,7 m, na którym zlokalizowane są dwa małe mosty (most nr 1 w km 3+455 i most nr 2 w km 3+365) i 11 przekrojów poprzecznych. W ramach obliczeń hydraulicznych określono przepustowość wytypowanego fragmentu rowu, przyjmując w obliczeniach przepływ miarodajny ustalony w projekcie wykonawczym systemu odwadniającego. Przepływ miarodajny, wynoszący 9,77 m3•s-1, posłużył również określeniu spiętrzenia w badanych mostach zgodnie z Rozporządzeniem Ministra Transportu i Gospodarki Morskiej. W wyniku pomiarów geodezyjnych stwierdzono zmiany kształtu przekrojów poprzecznych rowu i zmiany spadku dna na badanym odcinku rowu. Stwierdzono, że w warunkach konserwacji rowu jego przepustowość nie jest mniejsza od przepływu miarodajnego. Natomiast w przypadku zaniedbania konserwacji nastąpi zatopienie terenów znajdujących się przed mostem nr 1, co jest wynikiem mniejszej przepustowości rowu. Stwierdzono również, że badane mosty nie przyczyniają się pogorszeniu warunków przepływu wody miarodajnej przez rów na analizowanym jego fragmencie.
Źródło:
Geomatics, Landmanagement and Landscape; 2020, 4; 63-76
2300-1496
Pojawia się w:
Geomatics, Landmanagement and Landscape
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Gospodarka wodna jako dyscyplina naukowa w służbie rolnictwa
Water management as a scientific discipline serving agriculture
Autorzy:
Mioduszewski, W.
Szymczak, T.
Kowalewski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/339532.pdf
Data publikacji:
2011
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
gospodarka wodna
przepływ nienaruszalny
zasoby dyspozycyjne
zasoby wodne
available resources
base flow
water management
water resources
Opis:
W artykule przedstawiono gospodarkę wodną jako dyscyplinę naukową, dostarczającą informacji i podstaw metodycznych, niezbędnych do prawidłowego zarządzania zasobami wodnymi w rolnictwie i wspomagającą rozwiązywanie problemów z tym związanych. Przeanalizowano potrzeby wodne kraju i rolnictwa oraz wykorzystanie zasobów wód powierzchniowych i gruntowych. Wykazano, że duże znaczenie dla prawidłowej oceny dostępnych zasobów wód powierzchniowych ma sposób obliczania gwarantowanych zasobów dyspozycyjnych, które powinny być określane z uwzględnieniem sezonowej nieregularności odpływu rzecznego i analizy krzywych sum czasów trwania przepływów wyznaczanych oddzielnie dla poszczególnych miesięcy. Przedstawiono przykładowe obliczenia dla trzech zlewni nizinnych: Mławki, Sony Zachodniej i Moszczenicy. Dwie pierwsze zlewnie są położone w dorzeczu Wkry, a trzecia w dorzeczu Bzury. Z przedstawionych danych wynika, że analizowane zlewnie bardzo różnią się pod względem wielkości zasobów dyspozycyjnych i ich sezonowego rozkładu. Cechą wspólną jest natomiast niewystarczająca ilość lub całkowity brak tych zasobów w okresie letnim. Jak wynika z przedstawionych przykładów, bezpośrednie zagospodarowanie powierzchniowych zasobów wodnych przez rolnictwo w okresach największego zapotrzebowania na wodę jest praktycznie niemożliwe bez jej retencjonowania, a niezależnie należy ograniczać ilość wody na produkcję żywności. Powinno się to odbywać poprzez minimalizację nieproduktywnych strat, np. parowania z powierzchni gleby oraz poprzez dobór roślin o mniejszych potrzebach wodnych.
The paper presents water management as a scientific discipline providing information and methodological background for the proper management of water resources in agriculture and supporting solution of associated problems. Water demands of the country and of agriculture and the use of surface and ground water resources were analysed. It was demonstrated that the method of calculating guaranteed available resources is important for appropriate assessment of available resources of surface waters. These resources should be determined with the consideration of seasonal irregularity of the river outflow and the analysis of flow-duration curves estimated separately for particular months. Examples of calculations are presented for three lowland catchments of the Mławka, Sona Zachodnia and Moszczenica rivers. The first two are situated in the catchment basin of the Wkra River, the third - in the catchment of the Bzura River. Presented data show that the analysed catchments differ much with respect to available resources and their seasonal distribution. Their common feature is, however, an insufficient amount or a total lack of these resources in the summer period. As seen from presented examples, direct management of surface water resources by agriculture in the periods of highest demand for water is practically impossible without its retention. Moreover, the amounts of water for food production should be limited by minimizing non-productive losses (evaporation from the soil surface) and by selecting plants of lower water demands.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2011, 11, 1; 179-202
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Accidents of loss of flow for the ETTR-2 reactor: deterministic analysis
Autorzy:
El-Messiry, M.
Powiązania:
https://bibliotekanauki.pl/articles/146728.pdf
Data publikacji:
2000
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
design base accidents
LOFA
loss of flow
pump coastdown
reactor transients
Opis:
The main objective for reactor safety is to keep the fuel in a thermally safe condition with adequate safety margins during all operational modes (normal-abnormal and accidental states). To achieve this purpose an accident analysis of different design base accident (DBA) as loss of flow accident (LOFA), is required for assessing reactor safety. The present work concerns this transients applied to Egypt Test and Research Reactor ETRR-2 (new reactor). An accident analysis code FLOWTR is developed to investigate the thermal behaviour of the core during such flow transients. The active core is simulated by two channels: 1 - hot channel (HC), and 2 - average channel (AC) representing the remainder of the core. Each channel is divided into four axial sections. The external loop, core plene, and core chimney are simulated by different dynamic lumps. The code includes modules for pump coast down, flow regimes, decay heat, temperature distributions, and feedback coefficients. FLOWTR is verified against results from RETRAN code, THERMIC code and commissioning tests for null transient case. The comparison shows a good agreement. The study indicates that for LOFA transients, provided the scram system is available, the core is shutdown safely by low flow signal (496.6 kg/s) at 1.4 s where the HC temperature reaches the maximum value of 45.64°C after shutdown. On the other hand, if the scram system is unavailable, and at t=47.33 s, the core flow decreases to 67.41 kg/s, the HC temperature increases to 164.02°C, and the HC clad surface heat flux exceeds its critical value of 400.00 W/cm2 resulting from the fuel burnout.
Źródło:
Nukleonika; 2000, 45, 4; 229-233
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of base oil type on the rheological properties of ecological lubricating greases
Wpływ rodzaju bazy olejowej na właściwości reologiczne ekologicznych smarów plastycznych
Autorzy:
Kozdrach, Rafał
Powiązania:
https://bibliotekanauki.pl/articles/2143532.pdf
Data publikacji:
2021
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
lubricating grease
base oil
rheological properties
flow curve
yield point
rotational rheometer
smar plastyczny
olej bazowy
właściwości reologiczne
krzywa płynięcia
granica płynięcia
reometr rotacyjny
Opis:
The article presents the results of research on the influence the type of base oil in lubricating compositions has on the rheological parameters of selected lubricants. Vegetable, mineral, and synthetic dispersion phases were used to produce lubricating greases. The modified amorphous silica was used as the dispersed phase. However, as a modifying additive was used a substance containing the antioxidants, corrosion inhibitors, and EP/AW additives. The experiments on rheological properties were carried out using a Physica MCR 101 rotational rheometer (manufactured by Anton Paar), equipped with a diffusion air bearing and connected to a pneumatic supply – an oil-free Jun-Air compressor and air drying block. The device is equipped with a Peltier system for temperature control in the range of –20°C to 200°C and an external thermostatic VISCOTHERM V2 system, working in the temperature range of –20°C to 200°C. The rheometer control and measurement data analysis were performed using Rheoplus software. The tests were carried out using a cone-plate measuring system with a shear rate range of 0.01–100 s-1 at 20°C for lubricating compositions prepared on various oil bases. To evaluate the value of rheological parameters, the results of tests of the dependence between shear stress and shear rate (flow curves) were used. For the theoretical determined on the flow curves, the following rheological models were used: Bingham, Herschel–Bulkley, Casson, and Tscheuschner. The values of the shear stress (yield point) in depending on the type of dispersion phase has changed. This proves that the use of a base oil with the appropriate functional properties does not weaken, but reinforces the spatial structure of a lubricating grease. It has an important meaning when selecting construction parameters when designing a central lubrication system with grease made from a vegetable oil base (Abyssinian oil). The rheological properties of the lubricating grease are influenced by the type of base oil and thickener, any additives in the grease, the production technology of the grease, and the conditions in which it is used. The tests revealed an important influence of the base oil on the rheological parameters that describe the behaviour of lubricating compositions subjected to stresses and strains in a lubricating system.
W artykule przedstawiono wyniki badań wpływu rodzaju bazy olejowej kompozycji smarowych na wartości parametrów reologicznych badanych środków smarowych. Do wytworzenia smarów plastycznych zastosowano roślinną, mineralną i syntetyczną fazę dyspergującą. Jako fazę zdyspergowaną wykorzystano modyfikowaną krzemionkę amorficzną. Natomiast jako dodatku modyfikującego użyto substancji zawierającej w swoim składzie przeciwutleniacze, inhibitory korozji oraz dodatki EP/AW. Badania doświadczalne właściwości reologicznych wykonano za pomocą reometru rotacyjnego Physica MCR 101 (prod. Anton Paar), zawierającego dyfuzyjne łożysko powietrzne, podłączone do zasilania pneumatycznego – bezolejowego kompresora Jun-Air oraz bloku osuszającego powietrze. Aparat wyposażony jest w układ Peltiera kontroli temperatury w zakresie od −40 do –200°C oraz w zewnętrzny układ termostatujący Viscotherm V2, pracujący w zakresie temperatur od –20 do –200°C. Sterowanie reometrem oraz analizę danych pomiarowych przeprowadzono za pomocą oprogramowania Rheoplus. Badania wykonywano, stosując układ pomiarowy stożek–płytka, w zakresie szybkości ścinania 0,01–100 s−1 w temperaturze 20°C dla kompozycji smarowych wytworzonych na różnych bazach olejowych. Do oceny wartości parametrów reologicznych wykorzystano wyniki badań zależności naprężenia ścinającego od szybkości ścinania (tzw. krzywe płynięcia). Do teoretycznego wyznaczenia krzywych płynięcia zastosowano następujące modele reologiczne: Binghama, Herschela–Bulkleya, Cassona oraz Tscheuschnera. Wartość naprężenia ścinającego (granicy plastyczności) ulegała zmianie w zależności od rodzaju użytej fazy dyspersyjnej. Dowodzi to, że zastosowanie w smarze bazy olejowej o odpowiednich właściwościach użytkowych nie osłabia, ale wzmacnia jego strukturę przestrzenną. Ma to istotne znaczenie w doborze parametrów konstrukcyjnych przy projektowaniu układu centralnego smarowania z kompozycjami smarnymi na bazie oleju roślinnego. Na właściwości reologiczne smaru plastycznego wpływa zarówno rodzaj oleju bazowego i zagęszczacza, jak i dodatek dodawany do smaru, technologia jego wytwarzania, a także warunki, w jakich smar był stosowany. Przeprowadzone badania wykazały istotny wpływ bazy olejowej na wartości parametrów reologicznych opisujących zachowanie badanych kompozycji smarowych poddanych naprężeniom i odkształceniom w układzie smarowniczym.
Źródło:
Nafta-Gaz; 2021, 77, 2; 127-135
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies