Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "barrier structure" wg kryterium: Temat


Wyświetlanie 1-9 z 9
Tytuł:
Electro-optical performance and anisotropic transport study of a Ga-free type-II superlattice barrier structure
Autorzy:
Bouschet, Maxime
Arounassalame, Vignesh
Ramiandrasoa, Anthony
Perez, Jean-Philippe
Péré-Laperne, Nicolas
Ribet-Mohamed, Isabelle
Christol, Philippe
Powiązania:
https://bibliotekanauki.pl/articles/2204222.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Elektryków Polskich
Tematy:
infrared photodetector
type-II superlattice
barrier structure
Ga-free
transport
anisotropy
Opis:
In the past ten years, InAs/InAsSb type-II superlattice has emerged as a promising technology for high-temperature mid-wave infrared photodetector. Nevertheless, transport properties are still poorly understood in this type of material. In this paper, optical and electro-optical measurements have been realised on InAs/InAsSb type-II superlattice midwave infrared photodetectors. Quantum efficiency of 50% is measured at 150 K, on the front side illumination and simple pass configuration. Absorption measurement, as well as lifetime measurement are used to theoretically calculate the quantum efficiency thanks to Hovel’s equation. Diffusion length values have been extracted from this model ranging from 1.55 μm at 90 K to 7.44 μm at 200 K. Hole mobility values, deduced from both diffusion length and lifetime measurements, varied from 3.64 cm²/Vs at 90 K to 37.7 cm²/Vs at 200 K. The authors then discuss the hole diffusion length and mobility variations within temperature and try to identify the intrinsic transport mechanisms involved in the superlattice structure.
Źródło:
Opto-Electronics Review; 2023, 31, Special Issue; art. no. e144549
1230-3402
Pojawia się w:
Opto-Electronics Review
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ kładki "Bernatka" na strukturę funkcjonalno-przestrzenną krakowskiego Kazimierza i Podgórza
The influence of Bernatka footbridge on the functional and spatial structure of Cracows Kazimierz and Podgórze
Autorzy:
Sarga, A.
Powiązania:
https://bibliotekanauki.pl/articles/369512.pdf
Data publikacji:
2014
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
kładka piesza
most pieszy
struktura przestrzenna
bariera
rewitalizacja
footbridge
pedestrian bridge
spatial structure
barrier
revitalization
Opis:
W niniejszym artykule autorka przedstawia realizację pieszo–rowerowej kładki na Wiśle w Krakowie oraz jej wpływ na zmianę znaczenia struktury przestrzennej po obu jej stronach. Autorka pragnie jednocześnie wykazać, że kładka im. Ojca Bernatka nie jest jedy-nie elementem służącym przekroczeniu bariery jaką stanowi rzeka, ale przez oryginalną architekturę stała się identyfikatorem przestrzeni miasta, przyczyniając się jednocześnie do zmiany przestrzeni behawioralnej.
In this article the author presents the implementation of footbridge over the Vistula River in Cracow and its impact on changing the meaning of the spatial structure on both sides. The author intends to show that Bernatka footbridge is not merely a means to cross a barrier which is the river, but with its original architecture it becomes the identifier of urban space and also it changes behavioural space.
Źródło:
Przestrzeń i Forma; 2014, 21; 473-482
1895-3247
2391-7725
Pojawia się w:
Przestrzeń i Forma
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przepływ ciepła i ruch wilgoci w przegrodzie budowlanej
Autorzy:
Kowalik, M.
Powiązania:
https://bibliotekanauki.pl/articles/2068414.pdf
Data publikacji:
2009
Wydawca:
Politechnika Częstochowska
Tematy:
przepływ ciepła
struktura porowata
przegroda budowlana
ruch wilgoci
heat transfer
porous structure
building barrier
mass transfer
Opis:
Dokonano analizy przepływu ciepła i ruchu wilgoci w porowatej strukturze. Opisano podstawy teoretyczne problemu. Przedstawiono system równań rządzących procesem przepływu ciepła i ruchem wilgoci. Praca ma charakter przeglądowy.
Heat and mass transfer in porous structure is investigated. The theoretical formulation of the problem is described. A system of partial differential equations is discussed. The paper has a review character.
Źródło:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo; 2009, 15 (165); 119-125
0860-7214
Pojawia się w:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of barrier on the hydraulic response of composite weir-gate structure
Autorzy:
Quasim, Rafi M.
Abdulhussein, Ihsan A.
Al-Asadi, Khalid
Powiązania:
https://bibliotekanauki.pl/articles/1849769.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
struktura hydrauliczna
przegroda
bariera
jaz kompozytowy
poziom wody
odpowiedź hydrauliczna
hydraulic structure
baffle
barrier
composite weir-gate
water level
hydraulic response
Opis:
The composite weir-gate structure is considered an important hydraulic structure. This is because of its widely used in civil engineering hydraulic works especially in an irrigation system to measure, control, divert and keep the required water level. This study focuses on the influence of barrier existence on the hydraulic parameters that described the hydraulic characteristics of composite weir-gate hydraulic structure. In this study, several experimental runs were conducted to determine the effect of barrier's location, spacing and number on the water level and depth at the downstream region of flume, discharge coefficient of composite hydraulic structure, and flow rate throughout the flume. Our experiments indicated that the turbulence intensity, inlet effect, and position, gap, and number of barriers have affected the hydraulic behavior of weir-gate structure. This appears clearly by obtaining different results of discharge coefficient and flow rate that cross the weir-gate structure comparing with same cases without barriers. Also this study gives some insights on the significance roles of fluid separation, eddies generation near the barrier, fluid resistance and overlap between overflow and underflow velocities and their effects on hydraulic factors that dominate the problem. These hydraulic factors must be considered in the design and construction of barrier/barriers in open channel to prevent any fluctuation or drop in discharge, water elevation and the required water depth at downstream region.
Źródło:
Archives of Civil Engineering; 2020, 66, 4; 97-118
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Afforestations structure in the context of requirements for biogeochemical barriers in an agricultural catchment
Struktura zadrzewień w kontekście zapotrzebowania na bariery biogeochemiczne w zlewni o charakterze rolniczym
Autorzy:
Szyszkiewicz-Golis, M.
Powiązania:
https://bibliotekanauki.pl/articles/85718.pdf
Data publikacji:
2004
Wydawca:
Polska Asocjacja Ekologii Krajobrazu
Tematy:
afforestation structure
biogeochemical barrier
agricultural catchment
Directive 91-676-EEC
Wyskoc catchment
Koscian Obra Canal
Lake Morka catchment
landscape process
protection level
Źródło:
Problemy Ekologii Krajobrazu; 2004, 13
1899-3850
Pojawia się w:
Problemy Ekologii Krajobrazu
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Atopic eczema: genetics or environment?
Autorzy:
Wuthrich, B
Cozzio, A.
Roll, A.
Senti, G.
Kundig, T.
Schmid-Grendelmeier, P.
Powiązania:
https://bibliotekanauki.pl/articles/49593.pdf
Data publikacji:
2007
Wydawca:
Instytut Medycyny Wsi
Tematy:
inflammatory skin disease
environmental factor
food
atopy patch test
non-atopic eczema
Staphylococcus aureus
contact allergen
chronic disease
human disease
genetic condition
therapy
Malassezia sympodialis
skin disease
immunological deviation
atopic eczema
skin structure
skin infection
skin barrier
Opis:
Atopic eczema (AE) is a multifactorial skin disease caused by a variety of factors such as genetic conditions, alterated skin structure, immunologic deviations and environmental factors, among others. There are two main subtypes of AE, i.e. the IgE-associated (“atopic eczema”) and the non-IgE-associated type (“nonatopic eczema”) with different prognosis concerning the development of respiratory diseases (“atopy march”). Recently, it was demonstrated that Filaggrin (= fi lament-aggregating protein, FL) is a major gene for atopic eczema. Filaggrin binds to and aggregates the keratin cytoskeleton in the epidermis. Homozygous FLG mutation leads to complete loss of fi laggrin expression in skin. Half or more of children with moderate to severe AE carry FLG mutations. Moreover, fi laggrin loss-of-function mutations predispose to phenotypes involved in the atopy march. The altered skin structure and a defi ciency in antimicrobial peptides favour colonization with Staphylococcus aureus and yeasts (Malassezia sp.). Sensitization to the yeast occurs almost exclusively in AE patients. S. aureus enterotoxins with superantigenic activity stimulate activation of T cells and macrophages. So far, AE skin lesions are orchestrated by the local tissue expression of proinfl ammatory cytokines and chemokines with activation of T lymphocytes, dendritic cells, macrophages, keratinocytes, mast cells, and eosinophils which lead to the skin infl ammatory responses. From the therapeutic point of view, besides emollients and local corticosteroids, topic immunomodulatory drugs (tacrolimus and pimecrolimus) have substantially improved the treatment of AE.
Źródło:
Annals of Agricultural and Environmental Medicine; 2007, 14, 2
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przeglądy i diagnostyka balkonów
Balcony inspections and diagnostics
Autorzy:
Ślusarczyk, Jacek
Wójcik, Artur
Powiązania:
https://bibliotekanauki.pl/articles/1860628.pdf
Data publikacji:
2021
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
balkon
przegląd techniczny
wymagania techniczne
wymagania cieplno-wilgotnościowe
konstrukcja żelbetowa
otulina zbrojenia
hydroizolacja balkonu
odprowadzenie wody
badanie diagnostyczne
uszkodzenie
balcony
technical inspection
technical requirements
hygrothermal requirements
reinforced concrete structure
reinforcement cover
waterproof barrier
water disposal
diagnostic test
damage
Opis:
W pracy przedstawiono tematykę związaną z wykonywaniem przeglądów i diagnostyki balkonów o konstrukcji żelbetowej. W sposób zwięzły przypomniano wybrane warunki stawiane tego typu konstrukcjom. Następnie omówiono, co należy ocenić w czasie przeglądu. W sytuacjach wymagających przeprowadzania diagnostyki zostały omówione typowe badania oraz stosowana aparatura. Na podstawie doświadczeń własnych autorzy przedstawili przykłady typowych stanów technicznych od mających naturę estetyczno-użytkową aż po zagrażające bezpieczeństwu konstrukcji nośnej.
The paper presents the subjects related to inspections and diagnostics of balconies with a reinforced concrete structure. Selected conditions for this type of construction are briefly mentioned. Then the paper discusses what should be assessed during the review. Typical tests and equipment used are discussed for situations requiring diagnostic procedures. Based on their own experience, the authors present examples of typical technical states, from those of an aesthetic and functional nature to those that threaten the safety of the load-bearing structure.
Źródło:
Przegląd Budowlany; 2021, 92, 2; 15-20
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Odporność ogniowa konstrukcji słupowych zabezpieczonych okładzinami z gipsu syntetycznego
Fire resistance of pole structures protected with synthetic plastering
Autorzy:
Kania, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2055957.pdf
Data publikacji:
2021
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
konstrukcja prętowa
słup stalowy
zabezpieczenie ogniochronne
okładzina gipsowa
gips syntetyczny
odporność ogniowa
ściana gipsowa
izolacyjność ogniowa
pomiar temperatury
klasyfikacja ogniowa
bar structure
steel column
fire barrier
gypsum panel cladding
synthetic gypsum
fire resistance
gypsum wall board
fire insulation
temperature measurement
fire classification
Opis:
Konstrukcje prętowe, do jakich zaliczamy słupy, nie pełnią zwykle funkcji oddzielającej, w związku z czym powinny spełniać jedynie kryterium nośności ogniowej (R). Jednak w sytuacji, gdy słup tworzy ciągłą przegrodę z przylegającą do niego ścianą, wymagane są w stosunku do niego także dwa pozostałe kryteria: szczelności (E) oraz izolacyjności ogniowej (I). w artykule przedstawiono rozwiązanie zabezpieczeń przeciwpożarowych stalowych słupów konstrukcyjnych z wykorzystaniem okładzin z gipsu syntetycznego, materiału odpadowego uzyskanego w procesie odsiarczania spalin z paliw kopalnych metodą mokrą wapienną.
Bar structures, which include columns, usually do not have a separating function, and therefore should only meet the fire resistance (R) criterion. However, when a column forms a continuous partition with an adjacent wall, two other criteria are also required: tightness (E) and fire insulation (I). The article presents a fire protection solution for structural steel columns with the use of synthetic gypsum cladding, a waste material obtained in the process of desulphurization of fossil fuels using the wet lime method.
Źródło:
Przegląd Budowlany; 2021, 92, 11-12; 119--121
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Odporność ogniowa konstrukcji słupowych zabezpieczonych okładzinami z gipsu syntetycznego
Fire resistance of pole structures protected with synthetic plastering
Autorzy:
Kania, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2055983.pdf
Data publikacji:
2021
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
konstrukcja prętowa
słup stalowy
zabezpieczenie ogniochronne
okładzina gipsowa
gips syntetyczny
odporność ogniowa
ściana gipsowa
izolacyjność ogniowa
pomiar temperatury
klasyfikacja ogniowa
bar structure
steel column
fire barrier
gypsum panel cladding
synthetic gypsum
fire resistance
gypsum wall board
fire insulation
temperature measurement
fire classification
Opis:
Konstrukcje prętowe, do jakich zaliczamy słupy, nie pełnią zwykle funkcji oddzielającej, w związku z czym powinny spełniać jedynie kryterium nośności ogniowej (R). Jednak w sytuacji, gdy słup tworzy ciągłą przegrodę z przylegającą do niego ścianą, wymagane są w stosunku do niego także dwa pozostałe kryteria: szczelności (E) oraz izolacyjności ogniowej (I). W artykule przedstawiono rozwiązanie zabezpieczeń przeciwpożarowych stalowych słupów konstrukcyjnych z wykorzystaniem okładzin z gipsu syntetycznego, materiału odpadowego uzyskanego w procesie odsiarczania spalin z paliw kopalnych metodą mokrą wapienną.
Bar structures, which include columns, usually do not have a separating function, and therefore should only meet the fire resistance (R) criterion. However, when a column forms a continuous partition with an adjacent wall, two other criteria are also required: tightness (E) and fire insulation (I). The article presents a fire protection solution for structural steel columns with the use of synthetic gypsum cladding, a waste material obtained in the process of desulphurization of fossil fuels using the wet lime method.
Źródło:
Przegląd Budowlany; 2021, 92, 11-12; 119--121
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies