Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "ball–on–flat" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Friction coefficient determination based on the results of ball – on - flat test
Autorzy:
Szymczyk, E.
Jachimowicz, J.
Prasek, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/248003.pdf
Data publikacji:
2012
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
friction coefficient
ball-on-flat test
FFT
Opis:
The interaction of contacting surfaces in relative motion is basic for every engineering design. The transmission of load from one rubbing surface to its mating surface under conditions of dry contact is taken into account. Microlocal or global models of friction are used to describe this phenomenon. In global approach, frictional force is proportional to normal load. A coefficient of external friction depends on the type, shape, and precision of finishing the surfaces of mating elements. The aim of the paper is analysis of a friction coefficient for 2024T3 aluminium alloy during cyclic tangential loading. Experimental tests are carried out on a ball-on-flat wear-testing machine Ducom. Tests of reciprocating friction are carried out using the following friction pairs of specimens: the ball specimen is made of high strength aluminium alloy PA25 and the plane specimen is made of 2024T3 alloy. Finally, graphs of temporary friction coefficients versus time in the form of fluctuated periodical functions are obtained. Two phases of friction are detected. However, during the first stage, the friction coefficient is relatively small while in the second period it rapidly increases and tends to become more irregular. Static and dynamic friction coefficients are estimated. In order to determine the dynamic coefficient the Discrete Fourier Transformation is used. The calculation of the dominant amplitude (corresponding to test frequency) of the studied functions is possible due to this method. An increase of the friction coefficient with an increase of normal load is observed. A cladding layer also causes an increase of friction, especially in the second phase.
Źródło:
Journal of KONES; 2012, 19, 1; 415-422
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wear of Si or B doped amorphous carbon coatings
Zużycie amorficznych powłok węglowych domieszkowanych Si lub B
Autorzy:
Druet, K.
Łubiński, J.
Neyman, A.
Powiązania:
https://bibliotekanauki.pl/articles/188910.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
DLC coatings
wear testing
biomedical tribology
ball–on–flat
distributed contact
powłoki DLC
badania zużycia
tribologia biomedyczna
kula–płaszczyzna
styk konforemny
Opis:
The paper describes a complex wear research on DLC (amorphous carbon) doped with boron (B) and silicone (Si). The tests were carried out in two different sliding systems: flat–on–flat (ring contact, unidirectional sliding) and ball–on–flat (reciprocating sliding). Water and medical saline solutions were used as lubricants. A comparative analysis of the results revealed differences in the initiation and progress of wear and the endurance with regard to coating’s composition, lubricant and contact geometry. The results obtained from the tests show the influence of the additive element on the wear resistance and the high dependency of coatings’ performance in the type of contact and of the lubricant used. In all cases analysed, the use of medical saline solution resulted in accelerated wear or an increased result scatter in comparison to pure water lubrication.
W artykule przedstawiono wyniki kompleksowych badań zużycia powłok DLC domieszkowanych borem (B) oraz krzemem (Si). Zadanie zrealizowano w dwóch konfiguracjach styku ślizgowego: płaszczyzna – płaszczyzna (styk o kształcie pierścieniowym, ruch jednokierunkowy) i kula – płaszczyzna (ruch prostoliniowy, zwrotny). Jako smary wykorzystano wodę destylowaną i sól fizjologiczną. Analiza porównawcza wyników wykazała różnice w przebiegu inicjacji zużycia oraz w trwałości powłok w zależności od składu chemicznego powłoki, substancji smarowej i geometrii styku. Wyniki wskazują na wpływ wszystkich uwzględnionych czynników na zużycie. We wszystkich przypadkach zastosowanie soli fizjologicznej jako smaru skutkowało przyspieszonym zużyciem.
Źródło:
Tribologia; 2016, 268, 4; 55-67
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies