Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "automated test stand" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Experimental research on velocity profiles in selected flow systems
Autorzy:
Kabaciński, M.
Powiązania:
https://bibliotekanauki.pl/articles/1933977.pdf
Data publikacji:
2012
Wydawca:
Politechnika Gdańska
Tematy:
velocity profiles
air flow measurement
closed conduits
automated test stand
differential pressure flowmeter
Opis:
A problem of measuring of velocity profiles with the use of a fully automated test stand is presented in this paper. Due to the installed measurement equipment and various software alternatives it is possible to assess the inlet effect and distribution of velocities in the vicinity of averaging Pitot tubes in order to determine the phenomena occurring in their vicinity (recirculation, main stream direction) and verify the numerical models of turbulence. Due to the stream recirculation in the vicinity of the probes tested in a wind tunnel, a two-way probe was used instead of a Pitot tube. A linear module with a stepper motor formed an integral part of the measurement system whereby it was possible to determine the position of the measurement probe with a precision of 0.1mm. The measuring anemometer location, the possibility of adjusting the stream mean velocities and data acquisition were established by means of an original program. As far as the research in pipelines is concerned - the resulting characteristics allow the uncertainty of measurement to be precisely determined, which should be accounted for during the determination of air fluxes at locations which are not included in the technical documentation of a flowmeter.
Źródło:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk; 2012, 16, 3-4; 185-201
1428-6394
Pojawia się w:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Flow averaging tube geometry improvement for K-factor stability increase
Autorzy:
Kabaciński, M.
Pospolita, J.
Powiązania:
https://bibliotekanauki.pl/articles/114099.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
velocity profiles
air flow measurement
closed conduits
automated test stand
flow averaging Pitot tube
Opis:
Fluid flow around two-profile averaging differential pressure sensor was investigated in this paper. Research concentrated particularly on fluid movement direction and velocity over the investigated flow sensor. Analysis was conducted experimentally in low velocity wind tunnel. Because of large number of measuring points placed very close to each other, it was decided that velocity profile measurement will be performed by means of fully automated test stand. Due to a recirculation of the stream in the vicinity of the probe tested in the wind tunnel, an original two-direction probe was used. A linear module with a stepper motor formed an integral part of the measurement system. The location of the measuring probe, the possibility of adjusting stream mean velocities and data acquisition was undertaken by means of a dedicated program. The above mentioned investigation method helped to improve the metrological properties of the flowmeter applying non symmetrical probe cross-section forced air stream to be redirected in the desired direction. This modification significantly increased K-factor value and stability of air flow through the contraction of the flowmeter.
Źródło:
Measurement Automation Monitoring; 2017, 63, 1; 2-5
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of disturbed flow after an elbow on metrological properties of a Flow Averaging Tube
Autorzy:
Kabaciński, M.
Powiązania:
https://bibliotekanauki.pl/articles/114498.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
velocity profile measurement system
averaging Pitot tube
Flow Averaging Tube K-factor
elbow flow
automated test stand
Opis:
Experimental results of air velocity profiles and Flow Averaging Tubes (FAT®) K-factor measured behind an elbow are presented in this paper. The pipeline diameter was D=150 mm, while the range of mean velocities w=9…30 m/s. Velocity profiles were determined both in the vertical and horizontal plane in the respective distances L/D of a pipeline from 3 to 18. In the places of the measured velocity profiles, three cross-sections of flow averaging tubes (circular, streamlined and two-profile) were placed to determine the characteristics of K-factor. Moreover, a fully automated test stand is presented in this paper. The completed experiment allows shortening the distance between an elbow and a flowmeter installation place and informing about the value of a correction factor, which can be used to minimize the measurement uncertainty of the air flow rate. It was stated that the horizontal plane is better to install a probe because of the velocity profile and better results of repeatability.
Źródło:
Measurement Automation Monitoring; 2016, 62, 1; 7-16
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies