Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "atp6" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
The first evidence of a host-to-parasite mitochondrial gene transfer in Orobanchaceae
Autorzy:
Kwolek, Dagmara
Denysenko-Bennett, Magdalena
Góralski, Grzegorz
Cygan, Magdalena
Mizia, Patryk
Piwowarczyk, Renata
Szklarczyk, Marek
Joachimiak, Andrzej J.
Powiązania:
https://bibliotekanauki.pl/articles/952048.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
orobanche
hgt
horizontal gene transfer
atp6
mitochondrion
Opis:
Several parasitic plants are known to have acquired mitochondrial genes via a horizontal transfer from their hosts. However, mitochondrial gene transfer in this direction has not yet been found in the parasite-rich family Orobanchaceae. Based on a phylogenetic analysis of the mitochondrial atp6 gene in selected species of Orobanche s.l., we provide evidence of a host-to-parasite transfer of this gene in O. coerulescens, which is a Eurasiatic species that parasitises Artemisia (Asteraceae). We did not find the original Orobanche atp6 gene in this species, which suggests that it has been replaced by a gene that was acquired from Asteraceae. In addition, our data suggest the occurrence of a second HGT event in the atp6 sequence – from Asteraceae to Phelipanche. Our results support the view that the transfer of genetic material from hosts to parasites influences the mitochondrial genome evolution in the latter.
Źródło:
Acta Biologica Cracoviensia. Series Botanica; 2017, 59, 1
0001-5296
Pojawia się w:
Acta Biologica Cracoviensia. Series Botanica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie i analiza przepięć bardzo szybkozmiennych w elektroenergetycznych stacjach wysokiego napięcia izolowanych gazem SF6
Modeling and analysis of very fast transient overvoltages in high voltage gas insulated substations
Autorzy:
Raczek, R.
Pająk, P.
Powiązania:
https://bibliotekanauki.pl/articles/266923.pdf
Data publikacji:
2018
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
przepięcia bardzo szybko zmienne
stacja
izolowana gazem SF6
odłącznik
EMTP-ATP modelowanie
symulacje komputerowe
very fast transient overvoltages
gas insulated substation
disconnector
EMTP/ATP modeling
computer simulations
Opis:
W systemach elektroenergetycznych dla celów przesyłowych i dystrybucyjnych szerokie zastosowanie znalazły stacje izolowane gazem SF6 (ang. Gas Insulated Substations – GIS). Podlegają one narażeniom podczas występowania przepięć bardzo szybkozmiennych (ang. Very Fast Transient Overvoltages – VFTO). Generowana w wyniku łączenia styków odłącznika fala przepięciowa naraża układy izolacyjne oraz aparaturę w rozdzielni gazowej GIS. W artykule zostaną przedstawione zasady modelowania zjawisk przejściowych oraz wyniki symulacji komputerowych dla operacji zamykania odłącznika zainstalowanego w stacji GIS. Obliczenia zostaną przeprowadzone z wykorzystaniem programu Electromagnetics Transients Program – Alternative Transients Program (EMTP–ATP). Wyniki symulacji pozwolą na określenie maksymalnych wartości szczytowych przepięć, ich stromości oraz częstotliwości.
In electric power systems, for transmission and distribution purposes, gas insulated substations (GIS) are found a wide application. In case of various transient phenomena like switching operations and lighting, the GIS are subjected to the very fast transients overvolatages (VFTO). As a result of GIS disconnector opening or closing, an electromagnetic wave is generated. Such a wave endanger insulation systems and equipment installed in the gas switchgear, including cable lines, overhead transmission lines and transformers. Overvoltages analysis for insulation coordination studies is carried out while maintaing the acceptable value of Swithing Impulse Withstand Level (SIWL). This paper presents a state of the art modeling principles of transient phenomena and computer simulations results for closing operation of GIS disconnector installed in gas insulated substation. Calculations will be conduct by using computer simulation program like Electromagnetics Transients Program – Alternative Transients Program (EMTP–ATP). Simulation results will let to determine maximum overvoltages peak values, steepness and frequency range of this overvoltages.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2018, 60; 109-112
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cross-talk between the ATP and ADP nucleotide receptor signalling pathways in glioma C6 cells.
Autorzy:
Czajkowski, Rafał
Barańska, Jolanta
Powiązania:
https://bibliotekanauki.pl/articles/1043690.pdf
Data publikacji:
2002
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
ATP
cross-talk
glioma C6 cells
ADP
phospholipase C
nucleotide receptors
adenylyl cyclase
signalling pathways
adenosine
Opis:
In this review we summarize the present status of our knowledge on the enzymes involved in the extracellular metabolism of nucleotides and the receptors involved in nucleotide signalling. We focus on the mechanism of the ATP and ADP signalling pathways in glioma C6, representative of the type of nonexcitable cells. In these cells, ATP acts on the P2Y2 receptor coupled to phospholipase C, whereas ADP on two distinct P2Y receptors: P2Y1 and P2Y12. The former is linked to phospholipase C and the latter is negatively coupled to adenylyl cyclase. The possible cross-talk between the ATP-, ADP- and adenosine-induced pathways, leading to simultaneous regulation of inositol 1,4,5-trisphosphate and cAMP mediated signalling, is discussed.
Źródło:
Acta Biochimica Polonica; 2002, 49, 4; 877-889
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies