Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "architectural acoustic" wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
Analysis of the Room Acoustic with Impedance Boundary Conditions in the Full Range of Acoustic Frequencies
Autorzy:
Prędka, Edyta
Brański, Adam
Powiązania:
https://bibliotekanauki.pl/articles/176668.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
architectural acoustic
meshless method
radial bases functions
impedance boundary condition
Opis:
An efficiency of the nonsingular meshless method (MLM) was analyzed in an acoustic indoor problem. The solution was assumed in the form of the series of radial bases functions (RBFs). Three representative kinds of RBF were chosen: the Hardy’s multiquadratic, inverse multiquadratic, Duchon’s functions. The room acoustic field with uniform, impedance walls was considered. To achieve the goal, relationships among physical parameters of the problem and parameters of the approximate solution were first found. Physical parameters constitute the sound absorption coefficient of the boundary and the frequency of acoustic vibrations. In turn, parameters of the solution are the kind of RBFs, the number of elements in the series of the solution and the number and distribution of influence points. Next, it was shown that the approximate acoustic field can be calculated using MLM with a priori error assumed. All approximate results, averaged over representative rectangular section of the room, were calculated and then compared to the corresponding accurate results. This way, it was proved that the MLM, based on RBFs, is efficient method in description of acoustic boundary problems with impedance boundary conditions and in all acoustic frequencies.
Źródło:
Archives of Acoustics; 2020, 45, 1; 85-92
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Significance of Binaural Synthesis on the Spatial Acoustic Impression of Enclosures
Autorzy:
Alonso, A.
Murillo-Gómez, D. M.
Powiązania:
https://bibliotekanauki.pl/articles/176512.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
architectural acoustics
acoustic simulation
auralization
listening test
spatial impression
Opis:
Listening tests have been carried out to quantify the significance of binaural auralization over monaural auralization in accordance with the acoustic properties of the enclosure. To this end, acoustic rendering of three different rooms were generated based on synthesized monaural (two channels with the same audio material) and binaural room impulse responses. The auralizations were evaluated by means of subjective tests using headphones with non-individualized equalization. Parameters, such as localization, spatial impression and realism, were taken into consideration to determine the relevance of providing binaural information for the auralization of a given room. The analysis of the data has been conducted following a statistical approach based on ANOVA and Pearson correlation. The results indicate that spatial perception is strongly dependent on the acoustic characteristics of the rooms and on the listening condition of the audio material. Furthermore, as expected, advantages of binaural rendering in terms of source localization was also confirmed.
Źródło:
Archives of Acoustics; 2018, 43, 4; 613-624
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effects of the environmental factors in call centre interiors: a case study
Autorzy:
Jabłońska, Joanna
Ceylan, Salih
Powiązania:
https://bibliotekanauki.pl/articles/27314451.pdf
Data publikacji:
2023
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
open plan
open office
environmental factors
acoustic room comfort
architectural acoustics
physical workplace
healthy architecture
workspace
Opis:
Environmental factors in workspaces affect employee productivity and satisfaction, particularly in call centres. One of the most challenging issues in contemporary offices is overcoming the problems of concentration on work, despite adverse effects such as insufficient lighting, inappropriate acoustics, or inadequate ventilation. The challenges increase in open-plan solutions. This paper presents a case study from Turkey that elaborates on strategies to improve environmental performance in call centres. It is inspired by a questionnaire conducted among employees of a call centre, identifying existing design lacks. Based on the results, acoustic quality calculations of the physical workspace follow, and initial computing outcomes reveal that the conditions do not meet the standards for call centres. The authors propose strategies to improve acoustic performance in the workspace and apply them to a virtual model. Results reveal that the proposed solutions allow for meeting the standards. Based on the findings, the authors suggest several other strategies for improving the physical environmental quality of the place, thus forming a guideline for the architectural design of call centres. The study derives information from a specific case and context to propose universally applicable solutions. It fills a gap in the literature as it exemplifies the characteristics of call centres in Turkey, which have not been studied before.
Źródło:
Budownictwo i Architektura; 2023, 22, 4; 127--146
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zależności pomiędzy kształtem, a akustyką w prostopadłościennych ("pudełkowatych") salach koncertowych
Influence of shape on acoustics of "shoe-box" type concert halls
Autorzy:
Kłosak, A. K.
Powiązania:
https://bibliotekanauki.pl/articles/362772.pdf
Data publikacji:
2009
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
akustyka architektoniczna
komfort akustyczny
przestrzenność dźwięku
sale koncertowe
symulacje akustyczne
architectural acoustics
acoustic comfort
dolby surround
concert halls
acoustics simulation
Opis:
Praca opisuje wyniki komputerowych analiz akustycznych przeprowadzonych w 24 modelach sal koncertowych typu „pudełkowego". Przedstawione wyniki dotyczą trzech z opisanych w normie PN-EN ISO 3382 parametrów: Przejrzystości Brzmienia (C80), Siły Dźwięku (G) oraz Miary Wczesnej Energii Bocznej (LF80). Wyniki przeprowadzonych symulacji zostały ponadto porównane do opisanych w literaturze liniowych modeli regresyjnych, stworzonych na podstawie pomiarów w istniejących salach.
24 rectangular ,,shoe-box" type concert halls were simulated and analyzed using Odeon software. In this paper the influence of room shape and proportions on room averaged objective measures of Cg0, G and LFgo are presented.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2009, T. 4; 103-108
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania możliwości poprawy izolacyjności akustycznej ściany drewnianej
Measurement of possibility of sound insulation improvement of wood wall
Autorzy:
Dulak, L.
Żuchowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/362978.pdf
Data publikacji:
2007
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
akustyka budowlana
ściana szkieletowa drewniana
izolacyjność akustyczna od dźwięków powietrznych
wskaźniki oceny izolacyjności akustycznej właściwej
architectural acustics
wood wall
acoustic insularity
Opis:
Wyniki badaiń terenowych izolacyjności akustycznej ścian w budynku drewnianym, przeprowadzonych w ramach działalności naukowej Katedry Procesów Budowlanych [1], skłoniły autorów artykułu do kontynuacji tematu i poszerzenia wiedzy z tego zakresu o badania laboratoryjne wariantowych rozwiązań ścian drewnianych. Przedstawione wyniki badań próbują odpowiedzieć na pytanie jak przeprowadzone adaptacje ściany szkieletowej drewnianej wpływają na zmianę jej parametrów akustycznych.
Results of field measurement of sound insulation described in article [1 ], encourage to continuation of the work. Authors executed laboratory measurement of sound insulation of engineered wood wall framing. This paper presents results for elementary exterior wall, wall with additional thermal insulation and 3 walls with acoustics adaptations. After made adaptations, weighted apparent sound reduction index Rw increase from 35 dB to 56+59 dB. The results prove how strongly index value is depend on range frequencies. Evidently range 50+5000 Hz is proper for definition exterior wall acoustics parameters.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2007, T. 2; 25-28
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies