Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "application of chromatography" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Zastosowania chromatografii wykluczania (SEC) w analityce technicznej i preparatyce - część l-sza
Applications of Size Exclusion Chromatography (SEC) in technical analytics and preparative scalę separations - l-st part
Autorzy:
Boczkaj, G.
Fokt, A.
Momotko, M.
Kamiński, M.
Powiązania:
https://bibliotekanauki.pl/articles/92271.pdf
Data publikacji:
2014
Wydawca:
Uniwersytet Przyrodniczo-Humanistyczny w Siedlcach
Tematy:
chromatografia wykluczania
chromatografia żelowa
zastosowanie chromatografii
asfalteny
rozkład masy cząsteczkowej
size exclusion chromatography
gel permeation chromatography
application of chromatography
asphaltene
molecular weight distribution
Opis:
W pracy scharakteryzowano założenia teoretyczne oraz mechanizm rozdzielania w warunkach chromatografii wykluczania (SEC). Przeanalizowano wady i zalety tej techniki rozdzielania. Przedstawiono przegląd zastosowań obejmujący wykorzystanie SEC w analityce technicznej oraz w preparatyce. SEC w warunkach liofilowych znajduje zastosowanie do rozdzielania mieszanin polimerów t.j. polistyren, polibutadien, poliizopren, poli(dimetylosiloksan), poliamidy(np. nylon 6), poliakrylonitryl, poliolefiny, polialkohol winylowy), polichlorek winylu. W warunkach niewodnych rozdzieleniu ulegają także substancje nisko-, średnio- i wysokocząsteczkowe, takie ropa naftowa, oleje, asfalty, smoły, żywice. Główne zastosowania dla mieszanin substancji niskocząsteczkowych to rozdzielanie sacharydów, tłuszczów (grupowo na TAG, DAG, MAG i WKT), środków powierzchniowo czynnych, dodatków w polimerach, antybiotyków, węglowodorów aromatycznych. W warunkach hydrofilowych rozdzielaniu ulegają bardzo polarne polimery, biopolimery polisacharydy, białka, nukleotydy, czasami także w połączeniach z substancjami chemicznymi o niższej polarności, rozpuszczalnymi w wodzie. W drugiej części pracy opisane zostaną specyficzne zastosowania SEC w rozdzielaniu wielowymiarowym oraz preparatyce.
The paper describe the theoretical basis and the separation mechanism in size exclusion chromatography (SEC). Advantages and disadvantages of the process are highlighted. This work contain a review of applications in technical analytics and preparative separations. SEC in lipophilic conditions is used for separation of polymer mixtures including polystyrene, polybutadiene, polyisoprene, poły (dimethylsiloxane), polyamides (eg. nylon 6), polyacrylonitrile, polyolefins, poły (winyl alcohol), polywinyl chloride. In non-aqueous conditions also other mixtures can be separated including Iow-, medium- and high-molecular components such as crude oil, olls, bitumen, tar, resins. Main applications regarding to low-molecular substances include separations of saccharides, fats (group-type separation as TAG, DAG, MAG and FFA), surfactants, polymer additiwes, antibiotics, aromatic hydrocarbons. In hydrophilic SEC conditions a mixtures containing polar polymers, biopolymers as polysaccharides, proteins, nucleotides sometimes also with connection with other Iow polarlty chemical substances soluble in water. The second part of this paper will include a specific applications of SEC in multidimentional and preparatiwe separations.
Źródło:
Camera Separatoria; 2014, 6, 2; 87-105
2083-6392
2299-6265
Pojawia się w:
Camera Separatoria
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Environmental aspects of using gas chromatography for determination of pharmaceutical residues in samples characterized by different composition of the matrix
Środowiskowe aspekty zastosowania chromatografii gazowej do oznaczania pozostałości farmaceutyków w różnych matrycach
Autorzy:
Sadkowska, J.
Caban, M.
Chmielewski, M.
Stepnowski, P.
Kumirska, J.
Powiązania:
https://bibliotekanauki.pl/articles/205418.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
GC analyses
GC-MS analyses
gas chromatography
pharmaceutical residues
sector application of gas chromatography
chromatografia gazowa
GC
aspekt środowiskowy
oznaczanie leków
pozostałości farmaceutyczne
Opis:
This paper aims at presenting the possibilities of applying gas chromatography for the determination of pharmaceutical residues in different matrices. Section one of the study underscores the environmental advantages of employing GC for such analyses. Section two presents the innovative methods for determining pharmaceuticals in the environment. The last section discusses the results of the analysis of the GC and GC-MS market in Poland. According to the literature data, the described methods were applied for the analysis of real samples: wastewaters, surface waters, soil samples. The samples were collected from the Pomerania region and the Gulf of Gdańsk. The pharmaceuticals were determined in various environmental samples. The highest concentrations were found in raw wastewater, medium-in a treated wastewater, and the lowest-in surface water. The most frequently detected pharmaceuticals were: ibuprofen, paracetamol, diclofenac and naproxen, all belonging to NSAIDs. Furthermore, the results of the study of the Polish GC market indicate that a very limited number of entities are currently using chromatographic techniques, and pharmaceutical residues tests are exceptions, mainly due to the lack of the legal requirements in this field and the lack of own laboratories.
W artykule przedstawiono możliwości wykorzystania chromatografii gazowej (GC, GC-MS) do oznaczania pozostałości farmaceutyków w różnych matrycach. W części pierwszej opisano środowiskowe aspekty zastosowania techniki chromatografii gazowej do takich analiz; w części drugiej innowacyjne sposoby oznaczania leków w środowisku; w części trzeciej wyniki analizy rynku w Polsce pod kątem wykorzystania techniki GC i GC-MS do takich badań. Zgodnie z danymi literaturowymi, prezentowane tu metody zostały wykorzystane do analizy próbek rzeczywistych: ścieków, wód powierzchniowych, gleby, pochodzących z Pomorza i Zatoki Gdańskiej. Najwyższe stężenia leków stwierdzono w ściekach surowych, średnich – w ściekach oczyszczonych, a najniższe – w wodach powierzchniowych. Najczęściej wykrywanymi farmaceutykami były leki należące do grupy NLPZ: ibuprofen, paracetamol, diklofenak i naproksen. Wyniki badań polskiego rynku GC wskazują wyraźnie, że nieznaczna liczba podmiotów gospodarczych stosuje obecnie technikę GC do oznaczania leków w różnorodnych matrycach. Dzieje się tak na skutek braku przepisów prawnych w tej dziedzinie oraz braku własnych laboratoriów.
Źródło:
Archives of Environmental Protection; 2017, 43, 3; 3-9
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preparatywna chromatografia cieczowa, podstawowe zasady efektywnego stosowania, elementy praktyki
Preparative liquid chromatography, principles and examples of application in practice
Autorzy:
Bylina, A.
Kamiński, M.
Powiązania:
https://bibliotekanauki.pl/articles/92332.pdf
Data publikacji:
2010
Wydawca:
Uniwersytet Przyrodniczo-Humanistyczny w Siedlcach
Tematy:
preparatywna chromatografia cieczowa
zasady ogólne stosowania
dobór sorbentu
rozpuszczalno próbki
preparative liquid chromatography
general principles of application
sorbent selection
sample solubility
Opis:
Preparatywna chromatografia cieczowa jest techniką używaną do wyodrębniania pojedynczej, lub kilku substancji z mieszaniny kilku, albo bardzo wielu substancji, szczególnie o bardzo zbliżonych strukturach molekularnych, w tym, także do rozdzielania i otrzymywania izomerów optycznych. W pracy zamieszczono ogólne zasady optymalnego stosowania. Szczególną uwagę zwrócono na wybór sorbentu, ekonomi i problem rozpuszczalności próbki. Te problemy zostały opisane w oparciu o rzeczywiste procedury rozdzielania, stosowane w praktyce w laboratorium przemysłu farmaceutycznego.
Preparative liquid chromatography has been used as a tool for isolation of pure substances from a crude material first of all for separation of very complex mixtures and mixtures of similar compounds, e.g. isomers, optical isomers etc.. The general principles of PLC application, sorbent selection, economy and sample solubility problems are described based on the fragments of the real experiments and procedures.
Źródło:
Camera Separatoria; 2010, 2, (monographs No. 122); 57-70
2083-6392
2299-6265
Pojawia się w:
Camera Separatoria
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies