Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "anodic oxidation" wg kryterium: Temat


Wyświetlanie 1-10 z 10
Tytuł:
Conversion Coatings Produced on AZ61 Magnesium Alloy by Low-Voltage Process
Autorzy:
Nowak, M.
Płonka, B.
Kozik, A.
Karaś, M.
Gawlik, M.
Powiązania:
https://bibliotekanauki.pl/articles/356921.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
AZ61 magnesium alloy
anodic oxidation
corrosion resistance
Opis:
The resultes of anodic oxide conversion coatings on wrought AZ61 magnesium alloy production are describe. The studies were conducted in a solution containing: KOH (80 g/l) and KF (300 g/l) using anodic current densities of 3, 5 and 10 A/dm2 and different process durations. The obtained coatings were examined under a microscope and corrosion tests were performed by electrochemical method. Based on these results, it was found that the low-voltage process produces coatings conferring improved corrosion resistance to the tested magnesium alloy.
Źródło:
Archives of Metallurgy and Materials; 2016, 61, 1; 419-424
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Utlenianie anodowe biostopu Ti6Al4V w aspekcie jego zastosowań w implantacji
Anodic oxidation of Ti6Al4V bioalloy in the aspect of its applications in implantation
Autorzy:
Chorzelska, M.
Jażdżewska, M.
Powiązania:
https://bibliotekanauki.pl/articles/112322.pdf
Data publikacji:
2018
Wydawca:
Indygo Zahir Media
Tematy:
Ti6Al4V
anodowanie
implanty
anodic oxidation
implants
Opis:
Stop tytanu z aluminium i wanadem jest jednym z najczęściej używanych stopów tytanu w implantologii. Ti6Al4V charakteryzuje się dobrymi właściwościami i jest względnie tani. Na stopie wytworzono warstwy metodą anodowania, przy zastosowaniu trzech różnych elektrolitów i różnych parametrów procesu. Na wszystkich próbkach otrzymano nanorurki.
Titanium alloy with aluminum and vanadium is one of the most commonly used titanium alloy in implantology. Ti6Al4V has good properties and is relatively cheap. Oxide layers on the alloy were made by anodising process using three different electrolytes and different process parameters. Nanotubes were obtained on all samples.
Źródło:
Inżynier i Fizyk Medyczny; 2018, 7, 5; 317-319
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of Corrosion Resistance of Titanium Alloys Used for Medical Implants
Autorzy:
Szewczenko, J.
Marciniak, J.
Kajzer, W.
Kajzer, A.
Powiązania:
https://bibliotekanauki.pl/articles/351507.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
metallic biomaterials
titanium alloys
corrosion resistance
mechanical processing
anodic oxidation
Opis:
The study presents the results of investigations of modeling the usable properties of implant surfaces made of Ti6Al7Nb alloy, using the example of a dynamic hip screw (DHS) applied in surgical treatment of intertrochanteric femoral neck fractures. Numerical simulation has been performed for the model load of femoral fixation with DHS screw. The load simulation results provided the basis to select mechanical properties of the fixator elements and to define those fixation areas which are mostly susceptible to development of corrosion. The surfaces of Ti6Al7Nb alloy were ground, vibro-abrasive machined, mechanically polished, sandblasted, anode oxidized at different voltage values and steam sterilized. Results of surface topography evaluation, resistance to pitting and crevice corrosion as well as degradation kinetics of the outer layer were presented. Usability of the formed passive layer in clinical applications was evaluated through wear and corrosion tests of the femoral fixation model. The test results proved usefulness of the proposed surface modification methods for clinical application of different size and shape implants.
Źródło:
Archives of Metallurgy and Materials; 2016, 61, 2A; 695-700
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wytwarzanie nanorurkowych warstw tlenkowych na stopie tytanu Ti13Nb13Zr
Preparation of nano-tubular oxide layers on titanium alloy Ti13Nb13Zr
Autorzy:
Ossowska, A.
Zieliński, A.
Supernak, M.
Powiązania:
https://bibliotekanauki.pl/articles/284514.pdf
Data publikacji:
2011
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
stopy tytanu
utlenienia
struktura nanorurkowa
titanium alloys
anodic oxidation
nano-tubular structure
Opis:
W pracy przedstawiono wyniki badań utleniania i testów korozyjnych przeprowadzonych na stopie tytanu Ti13Nb13Zr w różnych warunkach. Warstewkę tlenkową wytworzono metodą elektrochemiczną w środowisku 2M H3PO4+0.3%HF w czasie 30 min. i 1h, przy stałym napięciu 20V. Testy korozyjne przeprowadzano metodą potencjodynamiczną w środowisku roztworu Ringera. Stwierdzono obecność nonorurkowych warstw tlenkowych na stopie Ti13Nb13Zr zwiększających odporność korozyjną nawet w kwaśnym środowisku.
The article presents results of oxidation tests and corrosion investigations of titanium alloyTi13Nb13Zr performed at different conditions. The oxide layer shave been formed using electrochemical method in 2M H3HPO4+0.3%HF solution for 30 min. and 1h at 20V constant voltage. The corrosion tests have been made with potentiodynamic method in Ringer`s solution at pH ranged between 3and 7. It has been shown that the nano-oxide films, which improved corrosion resistance of titanium alloyTi13Nb13Zr even in acidic environment, have been formed.
Źródło:
Engineering of Biomaterials; 2011, 14, no. 109-111 spec. iss.; 66-68
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Can titanium anodization lead to the formation of antimicrobial surfaces?
Autorzy:
Jastrzębska, A.
Jastrzębski, K.
Jakubowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/105680.pdf
Data publikacji:
2018
Wydawca:
Centrum Badań i Innowacji Pro-Akademia
Tematy:
Ti6Al4V
anodic oxidation
antimicrobial properties
utlenianie anodowe
właściwości antybakteryjne
Opis:
In recent years, there has been observed a growing need for novel, multifunctional materials that would not only replace, but also heal the damaged tissues. In this paper, the titanium dioxide films manufactured by anodic oxidation method are investigated. The study of their structurization and antimicrobial properties of the coatings is presented. Samples anodized in water solutions of ethylene glycol exhibited various character -from structurized to porous ones. As the study revealed, all samples acted anti-adhesive in terms of bacterial (Escherichia coli) and fungal (Candida albicans) surface colonisation.
Źródło:
Acta Innovations; 2018, 26; 21-27
2300-5599
Pojawia się w:
Acta Innovations
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Morphology of the Alumina Films Formed tn The Anodization Process of Aluminium in the Orthophosphoric Acid Solution. The Co-Fe Alloys Electrodeposition Into Obtained Alumina Pores
Morfologia warstewek tlenku glinu otrzymanych w procesie anodowego utleniania aluminium w roztworze kwasu ortofosforowego. Elektroosadzanie stopów CoFe w porach otrzymanego tlenku
Autorzy:
Gumowska, W.
Dobosz, I.
Wrzoszczyk, B.
Powiązania:
https://bibliotekanauki.pl/articles/352773.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
anodic oxidation of aluminium
nanowires
Co-Fe alloy
anodowe utlenianie aluminium
nanodruty
stopy Co-Fe
Opis:
The optimal parameters of the anodic oxidation of aluminium in orthophosphoric acid solution was determined. In the pores of the obtained Al2O3 membranes with the ordered nanometric structure Co-Fe alloys were electrodeposited. The Al2O3 membranes were obtained in the two-stage anodic oxidation of aluminium in the 0.17 M H3PO4 solution in the temperature 1°C and at the electrolysis voltage 180 V. The influence of the anodizing process parameters on the thickness of oxide films and the diameter of pores and the distance between them in the alumina membranes were determined. The electrodeposition of Co-Fe alloys was carried out from sulphate baths containing sulphates (VI) of copper (II) and cobalt (II) of different composition, in potentiostatic conditions. The optimal electrolysis conditions were determined, where the cathodic deposits of the best quality were obtained. The conditions are: the electrolyte composition: 0.3 M Fe; 0.5 M Co; pH = 3, the potential: -0.760 V (vs. SHE)).
Określono optymalne parametry' anodowego utleniania aluminium w roztworze kwasu ortofosforowego W porach uzyska- nych membran AI2O3, o uporządkowanej strukturze nanometrycznej. osadzano elektrolitycznie stopy Co-Fe. Membrany AI2O3 otrzymywano w procesie dwuetapowego utleniania aluminium w roztworze 0.17 M H3PO4. w temperaturze 1°C, przy napięciu elektrolizy 180 V. Zbadano wpływ parametrów anodowania na grubość warstewek tlenkowych, średnicę porów i odległości między nimi w membranach tlenku glinu. Elektroosadzanie stopów Co-Fe prowadzono z roztworów siarczanowych (VI) zawierających jony miedzi (II) i kobaltu (U) o różnym składzie, w warunkach potencjostatycznych. Określono optymalne warunki elektrolizy, w których otrzymano osady katodowe najlepszej jakości. A mianowicie: skład elektrolitu : 0,3 M Fe: 0,5 M Co: pH = 3, potential: -0.760 V (wzgl. SEW).
Źródło:
Archives of Metallurgy and Materials; 2014, 59, 1; 137-143
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
On influence of anodic oxidation on thrombogenicity and bioactivity of the Ti-13Nb- 13Zr alloy
Autorzy:
Szymonowicz, M.
Kazek-Kęsik, A.
Sowa, M.
Żywicka, B
Rybak, Z.
Simka, W.
Powiązania:
https://bibliotekanauki.pl/articles/951810.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
stopy tytanu
utlenianie anodowe
modyfikacja powierzchni
krew
vanadium-free titanium alloys
anodic oxidation
surface modification
blood compatibility
Opis:
Purpose: This paper reports the results of investigations of the blood response of the modified titanium alloys surfaces. Methods: To enhance biocompatibility of the Ti-13Nb-13Zr alloy, anodisation was performed at 80 and 150 V. The oxidation process was carried out in a solution containing 4 mol dm−3 H3PO4 and 0.59 mol dm−3 Ca(H2PO2)2. Results: The haemolytic activity of the titanium alloy surface was not altered much by the anodisation. The obtained values of the percentage of haemolysis were well below the levels required for the materials intended for blood contact. The clotting time of the blood was similar for the as-ground sample and the sample anodised at 80 V. For the sample anodised at 150 V the clotting time was shorter. The differences between these samples were observed in partial thromboplastin time after activation, prothrombin time and thrombin time, after 24 h. Extracts taken from the samples were not toxic towards the L-929 mouse fibroblast cells. Conclusions: The proposed treatment might be appropriate for the preparation of the modified Ti-13Nb-13Zr surfaces intended for bone reconstruction or cardiovascular implants depending on process parameters.
Źródło:
Acta of Bioengineering and Biomechanics; 2017, 19, 2; 41-50
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ modyfikacji powierzchni na własności fizykochemiczne tytanu stosowanego na implanty do kontaktu z krwią
Influence of surface modification on physicochemical properties of titanium used for bloodcontacting implants
Autorzy:
Kajzer, A.
Paszenda, Z.
Basiaga, M.
Walke, W.
Kajzer, W.
Powiązania:
https://bibliotekanauki.pl/articles/284177.pdf
Data publikacji:
2014
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
tytan cpTi
utlenianie anodowe
zwilżalność
odporność korozyjna
obróbka powierzchniowa
titanium cpTi
anodic oxidation
wettability
corrosion resistance
surface treatment
Opis:
Celem prowadzonych badań było określenie wpływu procesu utleniania anodowego powierzchni na własności fizykochemiczne tytanu. Wyniki badań stanowią podstawę do doboru optymalnych warunków utleniania anodowego do zastosowań na implanty do kontaktu z krwią. W ramach badań dla próbek w stanie wyjściowym oraz poddanych procesowi utleniania przy potencjałach od 40 V do 100 V co 10 V przeprowadzono ocenę zwilżalności powierzchni, badania potencjodynamiczne oraz impedancyjne. Na podstawie analizy uzyskanych wyników stwierdzono, że niezależnie od zastosowanego potencjału anodyzacji proces ten spowodował korzystne zwiększenie się potencjału korozyjnego E/kor oraz zwiększenie oporu polaryzacyjnego Rp w odniesieniu do próbek w stanie wyjściowym. Natomiast optymalny wariant przygotowania powierzchni, która będzie kontaktowała się z płytkami krwi stanowi utlenianie anodowe przy potencjale 100 V. Spowodowało ono znaczny wzrost oporu przejścia jonów na granicy faz Rct oraz wyeliminowanie elementu Warburga z układu zastępczego w stosunku do pozostałych analizowanych wariantów, co świadczy o bardzo dobrych własnościach ochronnych wytworzonej w ten sposób warstwy tlenkowej. Dla tak przygotowanej powierzchni stwierdzono najmniejszą zwilżalność oraz największą odporność korozyjną, co zapewnia zmniejszoną aktywację oraz adhezję płytek krwi do podłoża oraz biotolerancję w analizowanym środowisku. Wiadomo, że materiał o wysokim potencjale trombogennym powoduje adsorpcję materiału biologicznego na powierzchni oraz aktywację układu trombocytarnego, w wyniku czego wzrasta ryzyko powstawania między innymi powikłań zatorowo-zakrzepowych. Dlatego też przeprowadzone badania stanowią etap wstępny do analizy trombogenności powierzchni metodą Impact-R.
The aim of the research carried out was the determination of the influence of surface anodic oxidation process to physiochemical properties of titanium. Results form a basis for selecting optimum conditions of anodic oxidation for implants to be in direct contact with blood. The evaluation of surface wettability, potentiodynamical and impedance tests were conducted for samples at their initial condition and after they were subjected to the anodic oxidation process from 40 to 100 V every 10 V. The results revealed that regardless of the anodizing parameters applied the process has caused an advantageous decrease in corrosion potential E/kor and an decrease in polarisation resistance Rp in comparison to samples at their initial state. The optimum variant of surface that is meant to exist in direct contact with blood consists of anodic oxidation at 100 V. It has caused a substantial increase in ions transition residence Rct, increase at the interphase as well as elimination of the Warburg element from a substitute system compared to the remaining variants being analysed. This demonstrates the very good protective properties of an oxide layer obtained in this way. In the case of a surface treated in such a way, the lowest wettability and the highest corrosion residence have been found thus assuring a decreased activation and blood platelets adhesion to the substrate as well as higher biotolerance in the environment. It is known that materials having a high thrombogenic potential cause the adsorption of biological matter on the surface and the activation of thrombocytic system causing the increase of the risk of embolic and clot complications. That is why researches make an initial stage for the analysis of thrombogenic properties of surfaces according to the Impact-R method.
Źródło:
Engineering of Biomaterials; 2014, 17, 126; 23-30
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modification of Ti-6Al-4V Alloy Surface by EPD-PEO Process in ZrSiO4 Suspension
Modyfikacja powierzchni stopu Ti-6Al-4V metodą PEO-EPDw zawiesinie ZrSiO4
Autorzy:
Krząkała, A.
Młyński, J.
Dercz, G.
Michalska, J.
Maciej, A.
Niużyła, Ł.
Simka, W.
Powiązania:
https://bibliotekanauki.pl/articles/356201.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Ti-6Al-4V alloy
suspension
anodic oxidation
zirconium silicate
stop Ti6Al4V
zawiesina
utlenianie anodowe
krzemian cyrkonu
Opis:
Investigations on the surface modification of the Ti-6Al-4V alloy by plasma electrolytic oxidation are reported here. The oxidation process was carried out in a solution containing a zirconium silicate (ZrSiO4) suspension and sodium hydroxide (NaOH). Anodising was realised at voltages in a range from 100 V to 250 V. It was found that the morphology of the sample surface did not change during the oxidation of the alloy at 100 V. Application of voltages higher than 100 V led to the incorporation of zirconium silicate into the formed oxide layer and to significant changes of the surface morphology.
W pracy przedstawiono wyniki badań nad modyfikacją powierzchni stopu Ti-6A1-4V metodą plazmowego utleniania elek- trochemicznego. Proces ten prowadzono w roztworze zawierającym zawiesinę krzemianu cyrkonu (ZrSiO4 oraz wodorotlenek sodu (NaOH). Anodowanie prowadzono w zakresie napięcia od 100 do 250 V. Stwierdzono, że zastosowanie napięcia 100 V nie powoduje zmian w morfologii powierzchni stopu. Natomiast zastosowanie napięcia wyższego od 100 V powoduje wbudowanie krzemianu cyrkonu w tworzącą się warstewką tlenową oraz znaczne zmiany w morfologii powierzchni stopu Ti-6A1-4V.
Źródło:
Archives of Metallurgy and Materials; 2014, 59, 1; 199-204
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ przygotowania powierzchni oraz parametrów procesu utleniania anodowego na zwilżalność i odporność korozyjną tytanu CPTI GRADE 2
Impact of surface modification and parameters of anodic oxidation on wettability and corrosion resistance of titanium CPTI Grade 2
Autorzy:
Krupanik, Roksana
Rogowska, Patrycja
Sarraj, Sara
Walke, Witold
Powiązania:
https://bibliotekanauki.pl/articles/2201491.pdf
Data publikacji:
2019
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
CPTI
obróbka wibracyjno-ścierna
polerowanie elektrochemiczne
utlenianie anodowe
zwilżalność powierzchni
odporność na korozję wżerową
vibratory-abrasive processing
electrochemical polishing
anodic oxidation
surface wettability
resistance to pitting corrosion
Opis:
Reakcje zachodzące na granicy implant-tkanka kostna determinują sukces procesu implantacji. Są one ściśle związane z cechami powierzchni biomateriału. Badania wskazują, że implanty stosowane w ortopedii i traumatologii powinny się wyróżniać właściwościami osteokonduktywnymi. Według doniesień literaturowych ma na to wpływ odpowiednia chropowatość i zwilżalność powierzchni. Stąd też celem pracy było określenie zależności pomiędzy chropowatością i zwilżalnością powierzchni wytworzonych warstw oraz wartością napięcia prądu (40 – 85V) w procesie ich kształtowania.
Reactions occurring on the implant-bone tissue border determine the success of the implantation process. They are closely related to the surface characteristics of the biomaterial. Research indicates that implants used in orthopedics and traumatology should be distinguished by osteoconductive properties. According to literature reports, it is affected by the appropriate surface roughness and wettability. Therefore, the purpose of the work was to determine the relationship between the roughness and wettability of the surface of the produced layers and the value of current voltage (40 – 85V) in the process of shaping them.
Źródło:
Aktualne Problemy Biomechaniki; 2019, 18; 5--12
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-10 z 10

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies