Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "animal veterinary practice" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Mycological Air Quality at Animal Veterinary Practice
Autorzy:
Bulski, Karol
Frączek, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/2069913.pdf
Data publikacji:
2021
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
bioaerosol
fungi
air quality
animal veterinary practice
Opis:
The objective of the study was to characterize the mycological quality of air at animal veterinary practice in Krakow. Bioaerosol measurements were performed during the summer season of 2017. The samples of outdoor and indoor air at animal veterinary practice were collected using a 6-stage Andersen`s air sampler. The highest concentration of fungal aerosol was observed in the treatment room. The analysis showed various fungal contamination in different measuring points at different measuring times of the day. Based on the analysis of bioaerosol particle size distribution it was found that the largest "load" of fungi, isolated form the air, can reach (in the human respiratory tract) to the region of the throat, trachei and primary bronchi. The predominant fungi in indoor air was Penicillium spp. and Cladosporium cladosporoides. Fungi that can cause dermatophytoses have also been isolated from indoor air: Microsporum canis and Trichophyton verrucosum. The study confirmed that the animal veterinary practice can be a workplace related to exposure to microbial agents.
Źródło:
Rocznik Ochrona Środowiska; 2021, 23; 168--179
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bacteriological Air Quality at Animal Veterinary Practice
Bakteriologiczna jakość powietrza w gabinecie weterynaryjnym
Autorzy:
Bulski, Karol
Frączek, Krzysztof
Cendrowska, Anna
Chmiel, Maria J.
Powiązania:
https://bibliotekanauki.pl/articles/1812012.pdf
Data publikacji:
2019
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
bioaerosol
bacteria
air
animal veterinary practice
bioaerozol
bakterie
powietrze
gabinet weterynaryjny
Opis:
Due to the nature of the work (animal treatment and care of animals) the environment of small animal veterinary practice can be contaminated by microorganisms. Therefore, veterinary practices or hospitals are facilities, where veterinarians, clients and animals can be exposed to biological agents. The objective of the study was to characterize the bacteriological quality of air in small animal veterinary practice in Krakow. Bioaerosol measurements were performed during the summer season of 2017. The samples of outdoor and indoor air at small animal veterinary practice were analyzed, using a 6-stage Andersen's air sampler. The highest concentration of bacterial aerosol was observed in the treatment room. There were statistically significant differences in the concentrations of bacterial aerosol between indoor and out-door air. Also, the analysis showed that there were significantly higher airborne microbial loads in different rooms at different measuring times of the day. Based on the analysis of bioaerosol particle size distribution it was found that the largest "load" of bacteria, isolated form the air, can reach (in the human respiratory system) to the region of the nasal and oral cavity, throat and trachea, as well as bronchioles. In the indoor air, the predominant groups of microorganisms were rods of the Bacillus genus and Gram-positive cocci from the Micrococcus and Staphylococcus genus. The study confirmed that the small animal veterinary practice can be a workplace related to exposure to microbial agents.
Ze względu na specyfikę pracy (leczenie oraz opieka nad zwierzętami) środowisko gabinetu weterynaryjnego może być zanieczyszczone mikrobiologicznie. Gabinety czy szpitale weterynaryjne są placówkami, w których weterynarze, klienci i zwierzęta mogą być narażeni na działanie czynników biologicznych. Celem badań była charakterystyka bakteriologicznej jakości powietrza w gabinecie weterynaryjnym w Krakowie. Pomiary bioaerozolu wykonano w okresie lata w 2017 r. Próbki powietrza zewnętrznego oraz wewnętrznego w gabinecie weterynaryjnym pobierano przy pomocy 6-stopniowego impaktora Andersena. Najwyższe stężenie aerozolu bakteryjnego obserwowano w pokoju zabiegowym. Odnotowano istotne statystycznie różnice w stężeniach aerozolu bakteryjnego pomiędzy powietrzem wewnętrznym, a tłem zewnętrznym. Analiza wykazała również istotnie wyższe stężenia mikroorganizmów w zależności od punktu pomiarowego i pory dnia. Analizując rozkłady ziarnowe bioaerozolu stwierdzono, że najwyższy „ładunek” bakterii może dotrzeć (w układzie oddechowym człowieka) do rejonu jamy nosowej i jamy ustnej, gardła i tchawicy, a także oskrzelików. W powietrzu wewnętrznym dominującymi grupami mikroorganizmów były laseczki z rodzaju Bacillus i Gram-dodatnie ziarniaki z rodzaju Micrococcus i Staphylococcus. Badanie potwierdziło, że gabinet weterynaryjny może być miejscem pracy związanym z narażeniem na czynniki mikrobiologiczne.
Źródło:
Rocznik Ochrona Środowiska; 2019, Tom 21, cz. 2; 841-854
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies