Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "analiza objętościowa" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
U-Net based frames partitioning and volumetric analysis for kidney detection in tomographic images
Autorzy:
Les, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2090740.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
kidney detection
medical image processing
U-net
frames partitioning
volumetric analysis
wykrywanie nerek
przetwarzanie obrazu medycznego
partycjonowanie ramek
analiza objętościowa
Opis:
This work presents an automatic system for generating kidney boundaries in computed tomography (CT) images. This paper presents the main points of medical image processing, which are the parts of the developed system. The U-Net network was used for image segmentation, which is now widely used as a standard solution for many medical image processing tasks. An innovative solution for framing the input data has been implemented to improve the quality of the learning data as well as to reduce the size of the data. Precision-recall analysis was performed to calculate the optimal image threshold value. To eliminate false-positive errors, which are a common issue in segmentation based on neural networks, the volumetric analysis of coherent areas was applied. The developed system facilitates a fully automatic generation of kidney boundaries as well as the generation of a three-dimensional kidney model. The system can be helpful for people who deal with the analysis of medical images, medical specialists in medical centers, especially for those who perform the descriptions of CT examination. The system works fully automatically and can help to increase the accuracy of the performed medical diagnosis and reduce the time of preparing medical descriptions.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 3; e137051, 1--9
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
U-Net based frames partitioning and volumetric analysis for kidney detection in tomographic images
Autorzy:
Les, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2173575.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
kidney detection
medical image processing
U-net
frames partitioning
volumetric analysis
wykrywanie nerek
przetwarzanie obrazu medycznego
partycjonowanie ramek
analiza objętościowa
Opis:
This work presents an automatic system for generating kidney boundaries in computed tomography (CT) images. This paper presents the main points of medical image processing, which are the parts of the developed system. The U-Net network was used for image segmentation, which is now widely used as a standard solution for many medical image processing tasks. An innovative solution for framing the input data has been implemented to improve the quality of the learning data as well as to reduce the size of the data. Precision-recall analysis was performed to calculate the optimal image threshold value. To eliminate false-positive errors, which are a common issue in segmentation based on neural networks, the volumetric analysis of coherent areas was applied. The developed system facilitates a fully automatic generation of kidney boundaries as well as the generation of a three-dimensional kidney model. The system can be helpful for people who deal with the analysis of medical images, medical specialists in medical centers, especially for those who perform the descriptions of CT examination. The system works fully automatically and can help to increase the accuracy of the performed medical diagnosis and reduce the time of preparing medical descriptions.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 3; art. no. e137051
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Quantifying the influence of variations in rock mass properties on stope stability
Autorzy:
Shnorhokian, Shahé
Mitri, Hani
Powiązania:
https://bibliotekanauki.pl/articles/2201418.pdf
Data publikacji:
2022
Wydawca:
Główny Instytut Górnictwa
Tematy:
stope stability
rock mass variations
numerical modelling
footwall stability
volumetric analysis
brittle shear ratio
stabilność przodka
drgania górotworu
modelowanie numeryczne
stateczność spągu
analiza objętościowa
współczynnik ścinania kruchego
Opis:
Variations in rock mass properties are well-established in rock mechanics and underground mining. The literature is replete with methods of assessing them and determining values that are used in design or numerical analysis. In this paper, a simplified 3D model is constructed for a tabular orebody in the Canadian Shield and instability is quantified using the ”brittle shear ratio” criterion to calculate the volume at risk. A 1-4-7 stope pillar sequence is implemented on four active levels, and three variations in the properties of the host formation are assessed. It is observed that the locations of ore at risk follow the formations of stope pillars and are then transferred to the sill pillars above and below. Instability in the footwall and the hanging wall is observed to be lesser in volume but remains persistent. With the allocation of weak properties to the host rock, at-risk volumes increase in the orebody, footwall, and hanging wall, and the reverse trend occurs with strong greenstone properties. It is concluded that the stress increase in the orebody is due to transfers from the weaker host rock, while that in the greenstone formation is due to the use of a lower compressive strength value.
Źródło:
Journal of Sustainable Mining; 2022, 21, 4; 334--345
2300-1364
2300-3960
Pojawia się w:
Journal of Sustainable Mining
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiar gamma-gamma oraz komputerowa tomografia rentgenowska na rdzeniach wiertniczych skał osadowych
Gamma–gamma measurements and X-ray computed tomography applied to sedimentary rock cores
Autorzy:
Skupio, R.
Dohnalik, M.
Powiązania:
https://bibliotekanauki.pl/articles/1835472.pdf
Data publikacji:
2017
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
promieniowanie gamma
gęstość objętościowa
tomografia komputerowa
analiza rdzeni wiertniczych
skały osadowe
gamma radiation
bulk density
computed tomography
core analyze
sedimentary rocks
Opis:
Metody badawcze wykorzystujące absorpcję promieniowania elektromagnetycznego zostały zastosowane do ciągłych pomiarów gęstości rdzeni wiertniczych pobranych ze skał różniących się litologią oraz właściwościami petrofizycznymi. Pomiary gamma-gamma oraz tomografia komputerowa pozwalają na rejestrację profilu zmian gęstości z dużą rozdzielczością, bez ingerencji w analizowany materiał – metody nieinwazyjne. Zastosowanie badań całych rdzeni pozwoli na wprowadzenie oszczędności w budżetach firm poszukiwawczych, które często ograniczają rdzeniowanie, a przez to pomiary laboratoryjne do minimum. W przypadku występowania w badanych rdzeniach cienkich wkładek skał o odmiennej litologii, szczelin oraz żyłek kalcytowych – analizy wykonane na całym dostępnym materiale znacznie zwiększą możliwości interpretacyjne geofizyki otworowej. Do przeprowadzenia badań wykorzystano spektrometr gamma z aplikacją do pomiarów gęstości elektronowej (gamma logger core density – GLCD) oraz medyczny tomograf komputerowy z aplikacją konwertującą pliki graficzne na ciągły profil zmian gęstości wyrażonej w jednostkach Hounsfielda (computed tomography core density – CTCD). W pracy przedstawiono metodykę rejestracji parametrów oraz interpretację otrzymanych wyników.
Methods based on electromagnetic radiation absorption were applied to continuous density measurements, on rock cores of diverse lithology and petrophysical properties. Non-destructive techniques such as gamma-gamma and computed tomography measurements, allow for high resolution density core logging. Application of the proposed methods to whole core studies, helps with saving budget of companies, that reduces coring and laboratory measurements to minimum. In case of the occurrence of thin layers with different lithology, fractures or calcium veins, analysis performed on the entire available material will significantly increase the capabilities of well logging interpretation. To perform the tests, gamma spectrometer with bulk density application (gamma logger core density – GLCD) and medical tomography with an application which converts image files to continuous profile of density changes expressed in Hounsfield units (computed tomography core density – CTCD) were used. In this study the measurement method and the results interpretation technique were presented.
Źródło:
Nafta-Gaz; 2017, 73, 8; 571-582
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies