Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "alpha shape" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Verification and updating of the Database of Topographic Objects with geometric information about buildings by means of airborne laser scanning data
Autorzy:
Mendela-Anzlik, M.
Borkowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/1396875.pdf
Data publikacji:
2017
Wydawca:
Politechnika Warszawska. Wydział Geodezji i Kartografii
Tematy:
airborne laser scanning
Database of Topographic Objects
alpha shape
lotnicze skanowanie laserowe
baza danych obiektów topograficznych
kształt alfa
Opis:
Airborne laser scanning data (ALS) are used mainly for creation of precise digital elevation models. However, it appears that the informative potential stored in ALS data can be also used for updating spatial databases, including the Database of Topographic Objects (BDOT10k). Typically, geometric representations of buildings in the BDOT10k are equal to their entities in the Land and Property Register (EGiB). In this study ALS is considered as supporting data source. The thresholding method of original ALS data with the use of the alpha shape algorithm, proposed in this paper, allows for extraction of points that represent horizontal cross section of building walls, leading to creation of vector, geometric models of buildings that can be then used for updating the BDOT10k. This method gives also the possibility of an easy verification of up-to-dateness of both the BDOT10k and the district EGiB databases within geometric information about buildings. For verification of the proposed methodology there have been used the classified ALS data acquired with a density of 4 points/m2. The accuracy assessment of the identified building outlines has been carried out by their comparison to the corresponding EGiB objects. The RMSE values for 78 buildings are from a few to tens of centimeters and the average value is about 0,5 m. At the same time for several objects there have been revealed huge geometric discrepancies. Further analyses have shown that these discrepancies could be resulted from incorrect representations of buildings in the EGiB database.
Źródło:
Reports on Geodesy and Geoinformatics; 2017, 103; 22-37
2391-8365
2391-8152
Pojawia się w:
Reports on Geodesy and Geoinformatics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Algorytm modelowania 2D zabudowy na podstawie danych lotniczego skanowania laserowego z projektu ISOK
An algorithm of 2D building modeling in airborne laser scanning point cloud of the ISOK project
Autorzy:
Sochiera, K.
Borkowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/341191.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Przyrodniczy we Wrocławiu
Tematy:
lotniczy skaning laserowy
alpha shape
ogólny model wyrównawczy
ISOK
modelowanie 2D
airborne laser scanning
total least squares
2D modelling
Opis:
Dane lotniczego skanowania laserowego (ALS) pozyskiwane są najczęściej na potrzeby budowy numerycznych modeli wysokościowych. W Polsce dane takie pozyskane zostały dla obszaru niemal całego kraju w ramach projektu ISOK, związanego z osłoną przed zagrożeniami naturalnymi. Dane te zostały wykorzystane w niniejszej pracy do modelowania obrysów budynków. W tym celu zaproponowano algorytm będący kombinacją algorytmu α-shape do detekcji konturów budynków oraz iteracyjnego ogólnego modelu wyrównawczego do aproksymacji rzutów ortogonalnych ścian budynków. Identyfikację punktów reprezentujących obrysy budynków wykonano na podstawie chmury punktów, z której odrzucono punkty powyżej zadanej wysokości progowej. Identyfikacja obrysów budynków jako otoczki pustych powierzchni reprezentujących budynki dokładniej przybliża rzeczywiste położenie przyziemi ścian budynków. Do weryfikacji algorytmu wykorzystano chmurę punktów o gęstości 12 pkt/m2 reprezentującą miejski obszar zurbanizowany o zabudowie regularnej. Wyniki modelowania 2D budynków porównano z ich reprezentacją w bazie Ewidencji Gruntów i Budynków oraz obliczono odchyłki liniowe odpowiadających sobie narożników. Otrzymano średnią wartość odchyłki liniowej na poziomie 0,56 m. Wartość ta jest zgodna z nominalną dokładnością sytuacyjną danych ALS projektu ISOK. Błąd średniokwadratowy policzony na podstawie odchyłek liniowych wynosi 0,64 m. Otrzymane wyniki modelowania spełniają wymagania dokładnościowe Bazy Danych Obiektów Topograficznych 1:10000 (BDOT10k) i mogą być wykorzystane do jej weryfikacji, aktualizacji bądź zasilania.
Airborne laser scanning data (ALS) are acquired mostly for the purpose of digital elevation models generation. In Poland, ALS data have been obtained for the whole country within the ISOK project, established for natural hazards risk mitigation. These data were used in this study to model the outlines of buildings. For this purpose an algorithm is proposed, that is a combination of α-shape algorithm and iterative total least squares adjustment. α-shape is used to detect points representing building outlines while the total least squares method is performed to receive regularized 2D building vector models. Identification of points representing outlines of buildings was performed on the point cloud thresholded at the given height with rejection of points above that height. Identification of a building as a gap (internal hull) in ALS data set is a better approximation of real building shape. For the algorithm verification a point cloud with a density of 4 points /m2 is utilized. This point cloud represents a city urban area, covering 21 large buildings. The results of 2D modeling of buildings have been compared with their representation in the cadaster data base. The linear deviation between corresponding corners of modeled and represented in cadaster data base buildings have been measured. The received mean value of the deviation equal 0.56 m is consistent with the nominal planar accuracy of ISOK ALS data. RMSE of building outline modelling calculated on the basis of linear deviations was equal 0,64 m. The results of modeling meet the requirements of Topographic Database Objects 1: 10000 (BDOT10k) and can be used for verification and updating of this data base.
Źródło:
Acta Scientiarum Polonorum. Geodesia et Descriptio Terrarum; 2016, 15, 1-4; 19-33
1644-0668
Pojawia się w:
Acta Scientiarum Polonorum. Geodesia et Descriptio Terrarum
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An application of LSC method for the measurement of gross alpha and beta activities in spiked water and drinking water samples
Autorzy:
Çakal, G. Ö.
Güven, R.
Yücel, H.
Powiązania:
https://bibliotekanauki.pl/articles/146427.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
alpha activity
beta activity
drinking water
liquid scintillation counting (LSC)
pulse shape analysis (PSA) calibration
quench
Opis:
In this study, after the pulse shape calibration of a liquid scintillation counting (LSC) spectrometer (Quantulus 1220), the efficiency was determined depending on sample quenching parameters. Then, gross alpha and beta activities in two spiked water samples obtained from International Atomic Energy Agency (IAEA) were used for the validation of the ASTM D7283-06 method, which is a standard test method for alpha and beta activity in water by LSC. Later, the drinking water samples (35 tap water and 9 bottled water) obtained from different districts of Ankara, Turkey, were measured. The maximum gross alpha activities are measured to be 0.08 Bq/L for tap waters and 0.13 Bq/L for bottled waters, whereas the maximum gross beta activities are found to be 0.18 Bq/L for tap waters and 0.16 Bq/L for bottled waters. These results indicate that these drinking water samples are below the required limits, which are 0.1 Bq/L for alpha emitting radionuclides and 1 Bq/L for beta emitting radionuclides. As a result, gross alpha and beta activities in drinking water of Ankara were determined accurately by this validated LSC method. It is also worth noting that LSC is a rapid and accurate method for the determination of gross alpha and beta activities without requiring a tedious sample preparation.
Źródło:
Nukleonika; 2015, 60, No. 3, part 2; 637-642
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies