Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "alarm" wg kryterium: Temat


Tytuł:
Theoretical Investigation of Different Diversity Combining Techniques in Cognitive Radio
Autorzy:
Agarwal, R.
Srivastava, N.
Katiyar, H.
Powiązania:
https://bibliotekanauki.pl/articles/309425.pdf
Data publikacji:
2018
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
cognitive radio
complementary ROC
post examining selection
probability of detection
probability of false alarm
switch combining
examine combining
Opis:
In this paper, the performance of an energy detector in cognitive radio, using different diversity combining techniques, is evaluated. Among many diversity combining techniques, maximal ratio combining (MRC) gives the best results but at the cost of the highest complexity. To design a simpler receiver, it is suggested to use less complex combining techniques, i.e. switched diversity, which provides one of the least complex solutions to combat fading. The paper analyzes two switched diversity schemes, switch examine combining (SEC), and switch examine combining with post examining selection (SECp). A closed form expression determining the probability of detection using MRC, SEC and SECp is derived for various numbers of branches. Detection performance with different diversity combining techniques is compared and the complexity trade-off is observed.
Źródło:
Journal of Telecommunications and Information Technology; 2018, 3; 64-69
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
On Evaluation and Localization of Auditory Warning Devices for Adequate Audibility
Autorzy:
Asawarungsaengkul, K.
Nanthavanij, S.
Powiązania:
https://bibliotekanauki.pl/articles/91033.pdf
Data publikacji:
2013
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
multi-alarm location problem
auditory warning device
audibility evaluation
industrial noise hazard
droga ewakuacyjna
słyszalność
ewakuacja
urządzenia ostrzegające
hałas w przemyśle
lokalizacja urządzeń alarmowych
Opis:
This paper presents an analytic procedure to assist safety practitioners in evaluating the audibility of an existing auditory warning system in their workplaces. Two alarm location models are described: (a) a model with an unknown signal sound level, and (b) a model with a known signal sound level. A heuristic algorithm to determine a minimum number of alarm devices and their locations so that the warning signals can be clearly heard by workers is also proposed. The algorithm considers the ambient noise level, noise levels generated by individual machines, locations where workers are likely to be present, and noise levels at worker locations. From the numerical examples and the computation experiment, both the optimization and heuristic approaches yield solutions that satisfy the 15-dBA constraints. The heuristic approach is efficient in solving large alarm location problems due its capability to find near-optimal solutions within reasonable computation time.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2013, 19, 3; 355-369
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of firearms in the Polish law
Autorzy:
Babiński, Aleksander
Powiązania:
https://bibliotekanauki.pl/articles/1878629.pdf
Data publikacji:
2014
Wydawca:
Wyższa Szkoła Bezpieczeństwa Publicznego i Indywidualnego Apeiron w Krakowie
Tematy:
firearm
definition of a firearm
dangerous objects
combat weapons
hunting weapons
sporting guns
gas guns
alarm guns and signal guns
Opis:
Firearms are subject plays a greater or lesser role in our lives, and above all in the area of our security. Discussion on the need for surveillance of both access to firearms, as well as forms that it has taken must be based on the establishment of the Polish legislation defines as firearms. The concept is caused and causes a lot of controversy in doctrine and jurisprudence. Seeing the need in the article, the author presents the determination of firearms, paying particular attention to the importance of its legal determination in the law on firearms and ammunition and its evolution. Indicates the impact that EU law has had in its shape in the current content. The author presents the elements, the occurrence of which causes that we are dealing with firearms. Draws attention to the achievements of the doctrine, the necessary technical expertise conditioning knowledge of the subject which is the weapon. This indicates that they are necessary for the proper determination of its designations. The result indicates the elements that determines the occurrence of that we have to deal with weapons under Polish law. The author presents and attempts to unravel the dilemmas which arise as a result of a literal reading of the recognition of firearms in the law on firearms and ammunition. Not based upon the definition of substance only firearms, but also emphasizes the importance of determining the span of her discussing succession weapon: fighting, hunting, sporting, gas alarm and signaling. It also draws attention to how problematic recognition as a firearm finished or machined significant part of the weapon. Presented in the development of firearms issues certainly will deepen their knowledge in the stated range, and in the future accurately evaluate the behavior of the perpetrators as criminal acts or not prohibited.
Źródło:
Security Dimensions; 2014, 11(11); 12-22
2353-7000
Pojawia się w:
Security Dimensions
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowe wymogi dla autonomicznych czujek dymu
New Requirements for Smoke Alarm Devices
Autorzy:
Bakanov, V.
Mazur, J.
Powiązania:
https://bibliotekanauki.pl/articles/373834.pdf
Data publikacji:
2018
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
prEN 14604
autonomiczne czujki dymu
wymagania dla funkcji fakultatywnych
kompensacja zmian czułości
smoke alarm devices
requirements for optional functions
sensitivity fluctuation compensation
Opis:
Cel: Celem artykułu jest przedstawienie opóźnienia procesu standaryzacji w zakresie autonomicznych czujek dymu w stosunku do obecnego poziomu technologicznego tych urządzeń, a także identyfikacja błędów i nieścisłości w zapisach projektu normy prEN 14604. Dodatkowo celem artykułu jest zaproponowanie kierunków oceny ilościowej szeregu parametrów czujek dymu. Wprowadzenie: W artykule krótko przedstawiono historię rozwoju autonomicznych czujek dymu (od pierwszej jonizacyjnej czujki dymu typu 710 do miniaturowej autonomicznej czujki dymu i czujki multidetektorowej), a także historię międzynarodowych norm w tym zakresie (od pierwszej normy międzynarodowej ISO 12239 do projektu normy prEN 14604:2016). Metody: Omówiono główne założenia projektu normy prEN 14604, które są inne niż występujące w obecnie stosowanej normie EN 14604:2005. Zwrócono uwagę na niedopuszczalne używanie różnej terminologii w dokumencie normatywnym dla tego samego pojęcia. Ujawniono błędy techniczne w materiałach graficznych. Zaproponowano treść niektórych rozdziałów normy oraz uzupełnienie wymagań technicznych dla autonomicznych czujek dymu o parametry ilościowe. Zarekomendowano metodę sprawdzenia mechanizmu kompensacji zmian czułości autonomicznych czujek dymu poprzez utrzymanie wysokiej stabilności i niezbędnej prędkości wzrostu określonej gęstości optycznej powietrza w ograniczonej objętości. Wyniki: Zaproponowano wprowadzenie skrótu literowego SAD (Smoke Alarm Devices) i używanie go w całym tekście. Przedstawiono błędy w rysunkach znajdujących się w załącznikach G oraz I. Zaprezentowano nowe brzmienie rozdziału 3.1.6. Wystąpiono z propozycją dokonania zmian w rozdziałach 4.2.1.1 i 4.2.1.5. Zalecono uzupełnienie rozdziału 3.1.7. Przytoczono dowody na nietożsamość pojęć response value i sensitivity. Zasygnalizowano możliwość stworzenia stanowiska do sprawdzenia mechanizmu kompensacji zmian czułości autonomicznych czujek dymu. Potwierdzono konieczność wprowadzenia ilościowej oceny siły działającej na podzespoły urządzenia w celu ujednoznacznienia wniosków z badań. Wskazano na potrzebę zmiany wymagań technicznych w zakresie instalacji czujek autonomicznych na ścianie. Wnioski: Uwzględnienie przedstawionych propozycji zmian w normach zarówno europejskich, jak i krajowych pozwoli opracować dokumenty normatywne, które będą jednoznacznie interpretowane podczas prowadzenia badań autonomicznych czujek dymu w laboratoriach badawczych oraz w warunkach produkcyjnych.
Objective: The objective of this article is to present delays in the standardisation of smoke alarm devices in relation to the present technological advancement of such devices, and to identify errors and irregularities in draft prEN 14604 standard. In addition, the project aims at proposing directions for the quantitative evaluation of a number of parameters of smoke alarm devices. Background: The article presents a brief history of the development of smoke alarm devices (from the first type 710 ionisation smoke detector to ASD-10QR miniature autonomous smoke detector and Nest Protect multi-sensor detector), along with the history of the relevant international standards (from the first ISO 12239 to draft rEN 14604:2016). Methods: The main principles of the draft standard prEN 14604, which differ from those present in the currently binding EN 14604:2005, are discussed. Attention is drawn to the unacceptable use of various terms for one concept in the reference standard. Technical errors in images are demonstrated. The content of specific clauses of the standard is suggested, along with the proposed addition of quantitative parameters for the technical requirements for smoke alarm devices. A method of checking the mechanism of sensitivity fluctuation compensation in smoke alarm devices is proposed by retaining a high stability and the necessary rate of optical air density rise in a limited volume. Results: The abbreviation SAD (Smoke Alarm Devices) is proposed and used in the entire text. Errors in figures included in Annexes G and I are demonstrated, and the new wording of Clause 3.1.6 is proposed. A suggestion is also made to introduce changes to Clause 4.2.1.1 and 4.2.1.5, along with adding a new content to Clause 3.1.7. Evidence proving the non-equivalence of response value and sensitivity is presented. The possibility of creating a station for checking the mechanism of sensitivity fluctuation compensation in smoke alarm devices is indicated. The necessity of introducing the quantitative evaluation of the forces impacting on the device components is confirmed, in order to make the study results unambiguous. Finally, the need to change the technical requirements for wall-mounting smoke alarm devices is indicated. Conclusions: Taking into consideration the proposed changes to the European and national standards will make it possible to develop standards which will be unambiguously interpreted during smoke alarm device tests carried out in research laboratories and in production environment.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2018, 50, 2; 120-131
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie post-segmentacji do poprawy efektywności cech fazowych w detekcji zbicia szyby z użyciem transformacji falkowej
The use of post-segmentation for improvement of efficiency of phase features in glass breaks detection based on wavelet transformation
Autorzy:
Bemke, I.
Powiązania:
https://bibliotekanauki.pl/articles/157848.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
systemy alarmowe
algorytm
transformacja falkowa
alarm systems
algorithm
wavelet transformation
Opis:
Przedmiotem badań prowadzonych przez autora są bezkontaktowe metody detekcji zbicia szyby bazujące na analizie sygnałów akustycznych towarzyszących tem procesowi. Zagadnienie to ma zasadnicze znaczenie dla nowoczesnych systemów alarmowych, szczególnie w przypadkach dużych obiektów, gdzie indywidualne nadzorowanie każdej szyby byłoby nieekonomiczne. W toku badań opracowano metodę, bazującą na trnsformacji falkowej i identyfikacji wybranych cech sygnału, dającą efektywność detekcji >90%, a odporność na sygnały fałszywe >80%. W artykule przedstawiono metodę w wersji umożliwiającej jej implementacje w systemie przetwarzającym dane on-line, koncentrująć się na modyfikacji poprawiającej dydtynktywność cech fazowych sygnałów. W części końcowej zaprezentowano uzyskane wyniki i porównano je do reulttów przedstawinych w pracach [1] i [2].
The subject of research being made by author is a non-contact method of glass break detection, based on analysis of acoustic signals of the phenomena. Presented problem is very important for modem alarm systems, especially mounted in buildings with big amount of panes, where assembling of individual sensor for each pane is very expensive. In the progress of research author has developed the method of breaks detection based on Wavelet Transformation and identification of amplitude and phase features of the acoustic signal. Developed method achieves over 90% of detectability, and >80% of resistance for false signals. In the paper method adapted for embedded system with on-line processing is presented. Author focused on modificationss which improves the identyfication of phase features of the signals. The las parto of the article presents achieved results (detectability ad resistance to false signals) in comparision to result of the method presented in [1] and [2].
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9 bis, 9 bis; 123-126
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Funkcjonowanie Krajowego Systemu Wykrywania Skażeń i Alarmowania w obecnych uwarunkowaniach systemowych w Polsce
The National System of Contamination Detection and Alarm, Currently Operating in Poland
Autorzy:
Binek, T.
Czepiel, J.
Powiązania:
https://bibliotekanauki.pl/articles/372818.pdf
Data publikacji:
2014
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
terroryzm
skażenia
substancje niebezpieczne
KSWSiA
powodzie
BMR
terrorism
contamination
hazardous substances
National System of Detection and Alarm
flood
CBRN
Opis:
Cel: Rozwój cywilizacyjny niesie ze sobą szereg nowych zagrożeń, które dotychczas nie były znane ludzkości. Jednym z poważniejszych i charakterystycznych dla naszych czasów, tj. wieku XX i XXI, jest zagrożenie skażeniami. Niniejszy artykuł jest próbą przedstawienia Krajowego Systemu Wykrywania Skażeń i Alarmowania o Skażeniach i jego działania na tle charakterystyki zagrożeń skażeniami w obecnych uwarunkowaniach systemowych w Polsce. Wprowadzenie: W najnowszej historii doświadczyliśmy wielu katastrof, których efektem były skażenia. Tragicznie w nasze dzieje wpisują się awarie przemysłowe (Bhopal, Czarnobyl) skutkujące tysiącami ofiar śmiertelnych. Organizacje, których sposobem działania jest sianie terroru, za cel przyjmują sobie zastraszenie całych społeczeństw przy użyciu wszelkich dostępnych środków w tym tych, które uznawane są za broń masowego rażenia. W artykule scharakteryzowano krajowe rozwiązania przyjęte do przeciwdziałania tym zagrożeniom, w szczególności Krajowy System Wykrywania Skażeń i Alarmowania (KSWSiA). Zaprezentowano skład KSWSiA oraz jego zadania, przyjmując za główny punkt odniesienia obowiązujące uregulowania prawne. Niezwykle istotne dla funkcjonowania Krajowego Systemu jest funkcjonalne połączenie w jeden organizm wielu działających dotychczas w sposób nieskoordynowany w ramach zarządzenia kryzysowego struktur oraz służb ratowniczych zarówno cywilnych, jak i wojskowych, których działania koordynuje Centrum Dyspozycyjne. Takie rozwiązanie ma zoptymalizować ich działania i zapewnić efekt synergii. W artykule omówiono też sposób doskonalenia Krajowego Systemu poprzez prowadzenie ćwiczeń i treningów, a także wskazano niezbędne perspektywy rozwoju. Wnioski: KSWSiA jest systemem żywym, zmieniającym się w zależności od wyzwań, potrzeb i zadań, które są przed nim stawiane. Przedstawione w artykule rozwiązania z zakresu jego funkcjonowania powinny być poddawane nieustannej obserwacji, a ewentualna potrzeba zmian powinna je generować. Z pewnością rozwiązania te również warto propagować, zwracać na nie uwagę w procesie szkolenia kadr na potrzeby służb ratowniczych i centrów zarządzania kryzysowego oraz próbować wdrażać w instytucjach zajmujących się podobną problematyką, a niefunkcjonujących w ramach krajowego systemu np. w samorządach. Warto podjąć wysiłek zbudowania systemu pomiarowego przeznaczonego do detekcji skażeń oraz wdrożenia na różnych szczeblach w instytucjach i służbach zajmujących się problematyką reagowania kryzysowego systemu informatycznego PROMIEŃ.
Aim: The development of civilization is accompanied by new threats, which were previously unknown to mankind. One of the major and characteristic threats in the XX and XXI century, is the threat of contamination. This article describes the national system for detection of and warning about contamination hazards, and its operation within prevailing systems which exist in Poland. Introduction: In the recent past we experienced the effects of many natural disasters, which culminated in the contamination of the environment. Tragically, industrial accidents (Bhopal, Czarnobyl), led to thousands of casualties. Organisations, whose modus operandi involves the sowing of terror, focus on intimidation of whole communities utilising all available means, including weapons of mass destruction. This article identifies the national approach adopted to counter such threats, in particular the National System for Contamination Detection and Alarm (NSCDA). The NSCDA and its tasks are described in context of responsibilities laid down by law. It is essential for the effective operation of the system for participating services engaged in operations, who previously discharged their responsibilities in an uncoordinated way, to be functionally aligned and controlled by one body. The work of uniformed and non uniformed rescue services should be co-ordinated by a Dispatch Control Centre in order to optimise operational functionality and secure synergy. Additionally, the article describes approaches for improving the NSCDA through training and exercises, proposes essential development perspectives Conclusion: The NSCDA has functioned since 2006 and is a living system, which is adapted to changes, depending on the challenges, needs and tasks which emerge over time. Solutions presented in this paper should be constantly monitored and emerging environmental changes should influence appropriate changes to the system. Such adaptations should be propagated and incorporated in the training syllabus for personnel undergoing training in rescue techniques as well as crisis management. Equally, organisations which are also concerned with such problems, but currently not integrated within NSCDA e.g. Local Government Authorities, should implement such changes. It is appropriate to develop a monitoring system dedicated to the detection of contamination threats as well as engage the information system PROMIEN, at different levels, institutions and services involved with the problem of crisis response.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2014, 4; 15-24
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Economic justification for the new approach of using videobased smoke detection with the aim of decreasing total costs incurred by the untimely detection of fires on ships
Autorzy:
Bistrović, M.
Ristov, P.
Powiązania:
https://bibliotekanauki.pl/articles/135234.pdf
Data publikacji:
2017
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
fire alarm
video technology
computer vision
video detection
smoke detectors
ships
Opis:
Although various methods of using new techniques and technologies in ship fire alarm systems have been developed to date, some of which have made significant improvements in the functioning of such systems, in practice there is still plenty of room for further research regarding the operational efficiency of ship fire alarm systems and its impact on crew, passenger and overall ship safety. The application of electronic and computer technologies enables the development of intelligent solutions to improve the efficiency of ship fire alarm systems. Besides the economic justification, this paper presents a comparative analysis of classical and modern approaches based on video detection and computer vision in the detection of early phase smoke as a precursor to fire incidents. The economic justification of the new approach is concerned with decreasing the costs incurred by the untimely detection of the early stages of fire in ship engine rooms.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2017, 51 (123); 21-27
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selected issues of reliability and availability in marine vessel fire alarm systems
Autorzy:
Bistrović, Miroslav
Powiązania:
https://bibliotekanauki.pl/articles/135156.pdf
Data publikacji:
2019
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
reliability
safety
protection
availability
fire alarm system
human factor
Opis:
Today, every industry is striving for the highest efficiency and best economic results possible, with the greatest possible competitiveness. But in maritime affairs, human safety and environmental protection are the foundations of sustainability. To achieve this, marine systems must be reliable, high quality and easy to maintain. Because of this, reliability has become an important factor in safety, which remains relevant throughout the lifetimes of ship systems, including fire alarm systems. In this paper we address a number of issues connected with the reliability – and ‘availability’ of these systems. Firstly, ship fire alarm systems consist of various components whose individual reliability affect the system’s overall reliability. Discussions of reliability in ship fire alarm systems normally focus on the length of a system’s useful life or performance during design-based fire events. In addition to the reliability of systems, their availability for use is also crucial given the possibility that the system may need to operate at any point in time.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2019, 60 (132); 177-183
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The wireless notification systems used in car alarm systems
Systemy powiadamiania radiowego stosowane w systemach alarmowych samochodow
Autorzy:
Boguta, A.
Powiązania:
https://bibliotekanauki.pl/articles/793148.pdf
Data publikacji:
2012
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
car
alarm
global positioning system
wireless notification systems
modern method
vehicle tracking
security
monitoring
cell protection
monitoring system
satellite monitoring
mobile telephony system
bidirectional data transmission
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2012, 12, 1
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wymagania, metody badań i kryteria oceny właściwości sygnalizatorów optycznych (VAD). Metoda pomiaru rozsyłu światła
Requirements, Test Methods and Criteria For Assessing Optical Signaling Devices (VAD). The Method of Measuring Light Distribution
Autorzy:
Borysewicz, J.
Stępień, P.
Chołuj, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/373593.pdf
Data publikacji:
2016
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
sygnalizatory optyczne
światło błyskowe
bezpieczeństwo pożarowe
niepełnosprawność
visual alarm devices
beacon
fire safety
disability
Opis:
Wprowadzenie: Badania sygnalizatorów optycznych są prowadzone w oparciu o wytyczne normy europejskiej EN 54-23:2010 [1]. Dokument ten ułatwia, projektantom pożarowych systemów alarmowania, dobór właściwego sygnalizatora optycznego do konkretnego pomieszczenia. Wzięto w nim pod uwagę potrzeby osób niepełnosprawnych oraz uwzględniono aspekty medyczne, które mogą się pojawić przy użytkowaniu sygnalizatorów optycznych. Artykuł przedstawia budowę i sposób działania stanowiska do pomiaru źródła światła błyskowego oraz do pomiaru synchronizacji. Cel: Celem artykułu jest przedstawienie wybranych metod badań sygnalizatorów optycznych. Autorzy przyjęli za cel pracy zapoznanie czytelnika z różnymi aspektami wprowadzenia do badań normy europejskiej EN 54-23:2010 (Fire detection and fire alarm systems. Part 23: Fire alarm devices – Visual alarm devices). Artykuł ma na celu zapoznanie zainteresowanych osób z istniejącym stanowiskiem badawczym w laboratorium Sygnalizacji Alarmu Pożaru i Automatyki w CNBOP-PIB. Praca ta przedstawia wyniki badań przeprowadzonych w laboratorium, ich ocenę oraz wnioski. Metody i wyniki: W artykule opisano trzy podstawowe kategorie, do których należy zaklasyfikować dany sygnalizator optyczny. Podział uwzględnia sposoby montażu urządzenia na obiekcie. Umożliwia określenie wielkości i kształtu obszaru objętego sygnalizacją świetlną. Zawiera wskazówki dotyczące doboru odległości pomiędzy urządzeniami. Badania laboratoryjne polegają na wykonaniu serii pomiarów efektywnej intensywności światła. Pomiary są wykonywane w dwóch prostopadłych płaszczyznach i w tej samej odległości. Umożliwia to bardzo dokładne wyznaczanie kształtu i wymiarów obszaru, który jest obsługiwany przez pojedynczy sygnalizator optyczny. Ponadto w artykule przedstawiono metodę pomiaru synchronizacji dwóch sygnalizatorów. Zmierzono różnice czasu między dwoma rozbłyskami. Pomiary były wykonywane przez 30 minut od załączenia obydwu próbek. Wnioski oraz podsumowanie: Przeprowadzone w laboratorium pomiary światła emitowanego przez sygnalizator umożliwiają określenie kategorii i obszaru zastosowania sygnalizatora optycznego. Dzięki wykonanym badaniom lepiej można dobrać sygnalizator optyczny do konkretnego zastosowania oraz uniknąć niekorzystnych sytuacji, np. dla osób z symptomami padaczki. Zbudowane stanowiska usprawniają prace badawcze w laboratorium i dostarczają wielu cennych informacji konstruktorom sygnalizatorów optycznych.
Introduction: The effectiveness of fire risk notification depends not only on the speed of getting the message to the recipient. This information should also be noticed by people who, at that moment, for various reasons cannot hear it. The tests are carried out based on the guidelines of European Standard EN 54-23:2010. This document makes it easier for designers of fire alarm systems to select a proper visual alarm device for a specific room. The needs of disabled people were taken into account and medical aspects were included that may arise while using VADs. The article presents the construction and modus operandi of the measuring device used to measure the source of flash light and synchronization. Purpose: The purpose of this article is to present selected test methods of visual alarm devices. The authors have adopted as the purpose of study to acquaint the reader with various aspects introducing a European Standard EN 54-23:2010 (Fire detection and fire alarm systems. Part 23: Fire alarm devices - Visual alarm devices) when conducting tests. The aim of this article is to familiarize interested people with the measuring device located at the Laboratory of Fire Alarm Systems and Fire Automation in CNBOP-PIB. This work presents the results of tests that have been conducted at the laboratory. It also includes their evaluation and conclusions. Methods and results: The article describes three basic categories by which visual alarm devices should be classified. The division takes into account the method of mounting the device in buildings. This division allows to specify the size and shape of the area covered by the signaling light. It provides guidance on the assortment of the distance between the devices. Laboratory tests consist of making multiple series of measurements of the effective light intensity. Measurements are made in two perpendicular planes, and at the same distance. This allows to precisely determinate the shape and dimensions of the area which is supported by a single visual alarm device. Moreover, the method of measuring the synchronization of two VADs is described in the article. Time differences between two flashes were measured. The measurements were made during 30 minutes after the supply has been applied to the devices. Conclusions and summary: Measurements of light emitted by the VAD conducted at the laboratory allow to specify the category and application area of a visual alarm device. Due to the conducted measurements, a visual alarm device may be selected for a specific application and adverse situations can be avoided, for example: for people with symptoms of epilepsy. The measuring devices located in the laboratory improve tests conducted at the laboratory and provide valuable information for designers of the visual alarm devices.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2016, 44, 4; 159-164
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The use of ultrasonic detectors in peripheral object protection for casement windows security
Zastosowanie ultradźwiękowych czujek ruchu w oknach typu skrzynkowego w ochronie peryferyjnego objektu
Autorzy:
Buczaj, M.
Powiązania:
https://bibliotekanauki.pl/articles/793391.pdf
Data publikacji:
2013
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
alarm system operation
peripheral object protection
hazard detection
signalling system
attack
protected object
ultrasound detector
window
security
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2013, 13, 1
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multi-criteria problem of the alarm systems cost-functional characteristics optimization
Wielokryterialny problem optymizacji cenowo-funkcjonalnych cech systemów alarmowych
Autorzy:
Bykovyy, P.
Pigovsky, Y.
Sachenko, A.
Powiązania:
https://bibliotekanauki.pl/articles/323360.pdf
Data publikacji:
2012
Wydawca:
Politechnika Śląska. Wydawnictwo Politechniki Śląskiej
Tematy:
system alarmowy
optymalizacja wielokryterialna
optymalizacja Pareto
koszty
wydajność
alarm system
multiobjective optimization
Pareto optimization
costs
efficiency
Opis:
In present study the problem of an alarm systems optimization was presented and the stages of the multicriteria structured optimization method in cost-functional characteristics of the alarm system were also described. The method represents a combination of the proposed reflection and selection schemes in the genetic algorithm that solves the extreme combinatorics problem.
W proponowanym badaniu przedstawiono problem optymalizacji systemów alarmowych oraz zostały opisane etapy metody wielokryterialnej strukturalnej cenowo-funkcjonalnej optymalizacji systemu alarmowego. Metoda stanowi kombinację refleksji i planu wyboru algorytmu genetycznego, który rozwiązuje problem ekstremalnej kombinatoryki.
Źródło:
Zeszyty Naukowe. Organizacja i Zarządzanie / Politechnika Śląska; 2012, 61; 25-42
1641-3466
Pojawia się w:
Zeszyty Naukowe. Organizacja i Zarządzanie / Politechnika Śląska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Uniwersalne zasilanie urządzeń sygnalizacji i automatyki pożarowej z zasilaczy instalowanych poza centralą sygnalizacji pożarowej. Problemy i nowe możliwości
Autorzy:
Cygankiewicz, D.
Grabysz, W.
Klimasara, Z.
Powiązania:
https://bibliotekanauki.pl/articles/373137.pdf
Data publikacji:
2009
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
urządzenia alarmowe
urządzenia ochrony przeciwpożarowej
urządzenia sygnalizacji pożarowej
zasilacz
alarm devices
fire alarm equipment
power supplies
Opis:
Zasilacze sygnalizacji i automatyki pożarowej podlegają regulacjom zarówno europejskim jak i krajowym. Artykuł przedstawia te wymagania oraz sposób ich spełnienia w przypadku zasilacza maksymalnie uniwersalnego. W dalszej części zwraca się uwagę, że obowiązkowe wymagania są uderzająco powściągliwe, jeśli chodzi o sygnalizację stanu zasilaczy, szczególnie ich uszkodzeń. Przedstawia się koncepcję sygnalizacji ponad wymagane i przyjęte w praktyce standardy. Zaletą wdrożenia tej koncepcji powinno być ograniczenie kosztów utrzymania rozproszonego zasilania sygnalizacji i automatyki pożarowej.
Power supplies of equipment of fire alarm and protection automation are subject to both European and domestic regulations. The paper presents these requirement and a way of fulfill them for a power supply of most versatility. Further, it is noted that the compulsory requirement are strikingly restrained in case of indication of state of power supplies, in particular their failure. A concept of indication above the required and practically accepted standards is presented. Savings on maintenance costs of distributed power supply should be the benefit of implementation of this concept.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2009, 3; 161-180
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effects of Mutual Coupling of Radiating Antennas on an Adaptive Radar Detector
Autorzy:
De Nicola, S.
De Maio, A.
Farina, A.
Fiorini, M.
Infante, L.
Piezzo, M.
Powiązania:
https://bibliotekanauki.pl/articles/227055.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
adaptive radar
detection
mutual coupling effects
between radiating elements
constant false alarm rate
interference rejection
Opis:
In this paper, we address the adaptive detection/classification of signals in a homogenous interference environment. We refer to a radar system equipped with a phased array antenna and account for both the presence of mutual coupling between radiating antennas and a possible coherent interferer impinging on the array mainbeam. To deal with this scenario, we adopt a two-stage detection/classification scheme, enjoying the Costant False Alarm Rate (CFAR) property, to discriminate between target detection and coherent interferer rejection. Finally, we evaluate the system performance via Monte Carlo simulations. The results show that our system has interesting rejection capabilities and satisfactory detection levels. As a consequence, it could be successfully applied in real scenarios where mutual coupling is present.
Źródło:
International Journal of Electronics and Telecommunications; 2011, 57, 4; 451-457
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies