Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "air quality measurements" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Improving environmental odor measurements : comparison of lab-based standard method and portable odor measurement technology
Autorzy:
Maurer, D. L.
Bragdon, A. M.
Short, B. C.
Ahn, H.
Koziel, J. A.
Powiązania:
https://bibliotekanauki.pl/articles/204983.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
odor
volatile organic compounds
air quality measurements
standardization
olfactometry
Opis:
Current standard odor measurement methods are lab-based and require substantial investment in hardware, sample collection, training, and maintenance. Odor samples must be collected in the field using bags and brought to the lab to test. This can be a time-consuming process, with the possibility of the sample loss. The actual odor measurements are based on dilution olfactometry, embodied in the AC’SCENT® International Olfactometer, following the ASTM E679-04 standard. In recent years a portable olfactometer, the Scentroid SM100i, has been developed for odor measurements. The portable olfactometer has many advantages over lab-based standard method, especially the lower cost-per-sample. However, very little is known about the performance and reliability of portable olfactometer where the dilutions are controlled with orifices in metallic plates. It is important to evaluate the Scentroid SM100i accuracy to determine the usefulness of using it as a comparable technology for odor measurements. The main objective of this research is to compare the performance of the lab-based ASTM E679-04 method with portable odor measurement technology. Specific objectives include: (1) determining the accuracy of the dilution ratios specified by the manufacturer of both the AC’SCENT International Olfactometer and the Scentroid SM100i; (2) comparing results between olfactometers using n-butanol, a commonly used standard gas in the olfactometry field, and (3) determining the accuracy of odor measurement using real odor samples collected from livestock farms in Iowa. The AC’SCENT olfactometer had an average percent error between the factory specifications and measured dilution ratios of 5.23% compared with 14.1% for Scentroid SM100i (using plate i-2 with dilution range most comparable to the AC’SCENT olfactometer). The use of other dilution plates resulted in average percent errors ranging from 9.68% to 25.31%. The Scentroid SM100i deviated from the manufacturer specifications for flowrates and dilution ratios, but these flowrates were generally consistent with each dilution setting. Overall, the Scentroid SM100i overestimated the odor concentrations with the mean difference of 22.9% (ranging from 0.95% to 93.34%). When the post-measurement adjustment using dilution correction was made, the mean percent average difference was 11.8%.
Źródło:
Archives of Environmental Protection; 2018, 44, 2; 100-107
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Model DPSIR jako narzędzie efektywnego zarządzania jakością powietrza
The DPSIR model as an instrument to improve air qualit
Autorzy:
Adamiec, Ewa
Bartyzel, Jakub
Jarosz-Krzemińska, Elżbieta
Pełech-Pilichowski, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/27314310.pdf
Data publikacji:
2022
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
jakość powietrza
polityka energetyczna
model DPSIR
modelowanie
pomiary
air quality
DPSIR model
pressures
modelling
measurements
Opis:
Decyzje i działania (odpowiedzi) podejmowane na podstawie pełnej i wiarygodnej analizy czynników sprawczych, presji, zmiany parametrów stanu i ich wpływu na środowisko, społeczeństwo oraz gospodarkę mogą z dużym prawdopodobieństwem w długoterminowej perspektywie przynieść pożądane efekty. W artykule opisano model DPSIR (driving forces, pressures, state, impact, responses; odpowiednio: czynniki sprawcze, presje, stan, wpływ, odpowiedzi) służący do szczegółowej analizy interakcji pomiędzy czynnikami antropogenicznymi a środowiskiem. Tworzony model DPSIR będzie skutecznym narzędziem do zarządzania jakością powietrza. W artykule przedstawiono badania prowadzone w Akademii Górniczo-Hutniczej, które zostaną wykorzystane jako jedne z wielu danych wejściowych w powstającym modelu DPSIR. Opracowywany model będzie jednym ze składowych zaawansowanego narzędzia tworzonego na AGH, w ramach Obserwatorium Transformacji Energetycznej (OTE), które umożliwi przygotowanie rekomendacji optymalnych działań dotyczących realizacji polityki energetycznej i poprawy jakości powietrza w Polsce.
Decisions and actions taken base on analysis of the driving forces factors, pressures, changes in the parameters of the condition and their impact on the environment, society and economy may help to archive long term effects. This article describes the DPSIR (Driving Forces-Pressures-State-Impact-Responses) model for the analysis of anthropogenic and environmental interactions. The article describes the above-mentioned main components of the model and their meaning, which allows for the determination of air quality in Poland. In addition, selected research conducted at the AGH University of Science and Technology, which is part of the DPSIR model, is presented. The developed model will be one of the components of the advanced tool created by AGH, i.e. the Observatory of Energy Transformation (OTE), which will enable the preparation of recommendations for optimal actions regarding the implementation of energy policy and improvement of air quality in Poland.
Źródło:
Energetyka Rozproszona; 2022, 9; 35--44
2720-0973
Pojawia się w:
Energetyka Rozproszona
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody grawimetryczne i optyczne w pomiarach stężenia aerozoli
The use of optic and gravimetric methods relevant in aerosol concentration measurements
Autorzy:
Oberbek, Przemysław
Jakubiak, Szymon
Powiązania:
https://bibliotekanauki.pl/articles/2202808.pdf
Data publikacji:
2021
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
analiza grawimetryczna
ocena jakości powietrza
niskokosztowe sensory optyczne
systemy monitorowania zagrożeń
pomiary w czasie rzeczywistym
gravimetric analysis
air quality assessment
low-cost optical sensors
systems for risk monitoring
real-time measurements
Opis:
Zgodnie z danymi GUS o zatrudnionych w warunkach zagrożenia na koniec 2019 r., 2. pod względem częstości występowania czynnikiem szkodliwym były pyły, na które narażonych było 50,4 tys. osób (15,9%). Ocena narażenia na pyły w środowisku pracy polega na wykonaniu grawimetrycznych pomiarów stężeń na stanowiskach pracy dla zidentyfikowanych rodzajów pyłów, określeniu wskaźników narażenia na pyły i porównaniu uzyskanych wartości wskaźników narażenia z wartościami najwyższych dopuszczalnych stężeń pyłów. Wadami metody grawimetrycznej jest m.in. brak informacji o zmianach stężenia w czasie, podatność na dodatkowe źródła emisji, długi czas potrzebny na uzyskanie wyniku. Mierniki stężenia pyłów, przedstawiające dane pomiarowe w czasie rzeczywistym lub zbliżonym do rzeczywistego, znajdują coraz więcej zastosowań. Produkowane są już na dużą skalę niskokosztowe, niewielkie sensory, które można stosować do wytwarzania relatywnie dokładnych mierników środowiskowych, a także stacjonarnych i mobilnych sieci sensorowych. Tego typu urządzenia mogą stanowić istotne wsparcie dla grawimetrycznej oceny stężenia pyłów na stanowiskach pracy.
According to the data of the Statistics Poland on employees exposed to the risks arising from work environment at the end of 2019, the second most frequent harmful factor was dust, to which 50,4 thousand people were exposed (15,9%). The assessment of exposure to dust in the work environment consists in performing gravimetric measurements of concentrations at workstations for the identified dust types, determining the dust exposure indicators and comparing the obtained exposure indicator values with the values of the maximum allowable dust concentrations. The disadvantage of the gravimetric method is the lack of information about changes in concentration over time, susceptibility to additional emission sources, long time needed to obtain the result and the inability to conduct continuous monitoring. Dust concentration meters presenting real time or near to real-time measurement data are finding more and more applications in monitoring of the external environment and working environment Small low-cost sensors are already produced on a large scale, which can be used to produce relatively accurate environmental meters, as well as stationary and mobile sensor networks. Such devices are also not without flaws, but they can provide important support for the gravimetric assessment of dust concentration at workstations.
Źródło:
Bezpieczeństwo Pracy : nauka i praktyka; 2021, 2; 15-19
0137-7043
Pojawia się w:
Bezpieczeństwo Pracy : nauka i praktyka
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies