Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "air heat pump" wg kryterium: Temat


Tytuł:
Air–water heat pump applied as water boiler in singlefamily house, coefficient of performance analysis under the real conditions
Autorzy:
Lisowska-Lis, A.
Leszczyński, R.
Powiązania:
https://bibliotekanauki.pl/articles/93094.pdf
Data publikacji:
2018
Wydawca:
Państwowa Wyższa Szkoła Zawodowa w Tarnowie
Tematy:
heat pump
air-water
coefficient of performance
COP
pompa ciepła
powietrze-woda
współczynnik wydajności
Opis:
The subject of the research was an air-water heat pump, model PCUW 2.5kW from HEWALEX, installed in a single-family house. The pump is only used for heating water. The research was carried out from 25-08-2017 to 18-09-2017 in the village of Zborowice, in Malopolska region, Poland. The data were recorded from the heat pump system: temperature of the lower heat source (external air), temperature of the upper heat source (water temperature in the tank), time of heat pump was calculated during the analysed cycle of work and electrical energy consumption. The Coefficient Of Performance (COP) of the analysed air-water heat pump was determined. The analysis of the results was carried out using the MATLAB and EXCEL statistical tools. The correlation between COP coefficient and external air temperature is strong: 0.67.
Źródło:
Science, Technology and Innovation; 2018, 3, 2; 58-61
2544-9125
Pojawia się w:
Science, Technology and Innovation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza efektywności elementów systemu wykorzystującego pompę ciepła do ogrzewania tunelu foliowego
Analysis of the effectiveness of the elements of the system using a heat pump to heat a foil tunnel
Autorzy:
Kurpaska, S.
Latała, H.
Michałek, R.
Sporysz, M.
Powiązania:
https://bibliotekanauki.pl/articles/290111.pdf
Data publikacji:
2008
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
tunel foliowy
pompa ciepła
efektywność
wymienniki ciecz-powietrze
foil tunnel
heat pump
effectiveness
liquid-air exchangers
Opis:
W pracy przedstawiono wyniki badań nad efektywnością pompy grzewczej współpracującej z systemem odbioru ciepła wykorzystywanej do ogrzewania tunelu foliowego. Energia z górnego źródła ciepła przekazywana była do ogrzewania obiektu poprzez system ogrzewania powietrznego. System ten stanowiły wymienniki ciecz-powietrze w których następowało, w warunkach przepływu wymuszonego, ogrzewanie powietrza wewnątrz tunelu foliowego. Znaleziono zależności efektywności pompy ciepła i sprawności wymienników od warunków klimatu na zewnątrz i mikroklimatu wewnątrz obiektu.
In the paper the results of studies on the effectiveness of a heat pump cooperating with a heat receiving system, used to heat a foil tunnel, are presented. Energy from the upper heat source was transmitted through the air heating system and used for heating the object. The system included liquid-air exchangers in which, under the conditions of forced flow, air inside the foil tunnel was heated. Interrelationships between the effectiveness of the heat pump and efficiency of the exchangers and weather conditions outside and the microclimate inside the object have been found.
Źródło:
Inżynieria Rolnicza; 2008, R. 12, nr 2(100), 2(100); 163-170
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza energetyczna, ekologiczna i ekonomiczna współpracy odnawialnych źródeł energii z pompą ciepła
Energy, ecological and economic analysis of cooperation of renewable energy sources with a heat pump
Autorzy:
Wienchol, Paulina
Powiązania:
https://bibliotekanauki.pl/articles/101721.pdf
Data publikacji:
2018
Wydawca:
Politechnika Śląska. Wydział Inżynierii Środowiska i Energetyki. Instytut Techniki Cieplnej
Tematy:
odnawialne źródła energii
zapotrzebowanie cieplne budynku
gruntowa pompa ciepła
powietrzna pompa ciepła
rozwój zrównoważony
renewable energy sources
building heat demand
ground heat pump
air heat pump
sustainable development
Opis:
W ramach Polityki UE do 2030 r. realizowane są trzy główne cele, które związane są ze zmniejszeniem emisji gazów cieplarnianych, zwiększeniem udziału odnawialnych źródeł energii i wzrostem efektywności energetycznej. Wykonanie założonego planu wiąże się przede wszystkim z dokonaniem niezbędnych inwestycji w sektorze komunalno-bytowym. Jest to spowodowane znaczącą ilością emisji zanieczyszczeń, które pochodzą z lokalnych kotłów i palenisk. Celem niniejszej pracy jest analiza energetyczna współpracy odnawialnych źródeł energii z pompą ciepła, na przykładzie wybranego domu jednorodzinnego, zlokalizowanego w województwie śląskim. Podczas analizy zbadano dwa przypadki,w pierwszym budynek jest ogrzewany wyłącznie gruntową pompą ciepła, a w drugim powietrzną. Następnie porównano działanie obu pomp pod względem efektywności energetycznej. W analizie ekologicznej sprawdzono wpływ wykorzystania alternatywnych źródeł energii do zasilania pompy ciepła i urządzeń gospodarstwa domowego na stan środowiska naturalnego. Analizowanymi źródłami odnawialnej energii jest energia słoneczna oraz wiatrowa. Na podstawie ich podstawowych charakterystyk oraz rzeczywistych danych środowiskowych, dotyczących promieniowania słonecznego, prędkości wiatru i temperatury otoczenia, obliczono ilość produkowanej energii w wybranych instalacjach. Następnie przeprowadzono analizę ekonomiczną, w której obliczono prosty czas zwrotu omawianych inwestycji. Otrzymane wyniki pozwolą na stwierdzenie, które urządzenie grzewcze pracuje bardziej wydajnie oraz jakie źródło odnawialnej energii przyniesie większe korzyści pod względem energetycznym, ekologicznym oraz ekonomicznym.
Within the framework of the EU Policy until 2030, three main objectives are pursued, which are related to reducing greenhouse gas emissions, increasing the share of renewable energy sources and energy efficiency. The implementation of the plan is associated with making the necessary investments in the municipal and living sector. This is caused by a significant amount of pollutant emissions that originate from local boilers and hearths. The purpose of this work is energy analysis of cooperation of renewable energy sources with a heat pump, on the example of a selected single-family house, located in the Silesian. During the analysis, two cases were examined, in the first building itis heated only with a ground heat pump, and in the second one it is air-heated. Then the operation of both pumps was compared in terms of energy efficiency. In the ecological analysis, the effect of using alternative energy sources to power the heat pump was checked and household appliances for the condition of the natural environment. The analyzed sources of renewable energy are solar and wind energy. Based on their basic characteristics and real environmental data, regarding solar radiation, wind speed and ambient temperature, the amount of energy produced in the installations was calculated. Then, an economic analysis was carried out, in which the simple payback time of the discussed investments was calculated. The obtained results will allow to determine which heating device works more efficiently and what source of renewable energy will bring greater benefits in terms of energy, ecology and economy.
Źródło:
Archiwum Instytutu Techniki Cieplnej; 2018, 4; 127-151
2451-277X
Pojawia się w:
Archiwum Instytutu Techniki Cieplnej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza możliwości wykorzystania pomp ciepła w układzie grzewczo-chłodniczym samochodu
Analysis of the possibility of using heat pumps in the heating and cooling system of the car
Autorzy:
Grygierzec, J.
Werle, S.
Powiązania:
https://bibliotekanauki.pl/articles/127226.pdf
Data publikacji:
2018
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
klimatyzacja
ogrzewanie
pompa ciepła
samochód elektryczny
air conditioning
heating
heat pump
electric car
Opis:
W ostatnich latach rozwój pojazdów osobowych ukierunkowuje się na systemy „ekologiczne”, często opierające się o napęd elektryczny. Wykorzystanie technologii napędu elektrycznego w pojazdach zmienia zasady ogrzewania i chłodzenia powierzchni pasażerskiej. Dodatkowym aspektem jest utrzymanie odpowiednich warunków pracy akumulatorów zasilających. Powoduje to konieczność zmiany rozwiązań w układzie grzewczo-chłodniczym. Układy stosowane w samochodach spalinowych korzystają z nadwyżek temperatur, pobierając ciepło i przenosząc je do kabiny pasażerskiej. Chłodzenie odbywa się z wykorzystaniem obiegu czynnika chłodniczego, napędzanego sprężarką obciążającą silnik. Samochody elektryczne z uwagi na ograniczony dostęp do magazynowania energii oraz widoczny wpływ dodatkowych urządzeń na zasięg jazdy wymagają metod efektywnych i oszczędnych. Ze względu na złożoność wymagań stawianym klimatyzacji zostają wprowadzone rozwiązania znane z zastosowań pomp ciepła w budownictwie. Technologie tego typu pozwalają na odciążenie elektrycznych nagrzewnic poprzez odbiór ciepła z zewnątrz. Wszystkie metody mają charakter rozproszony, tzn. elementy układu zabudowane są w różnych częściach pojazdu. Innowacyjnym rozwiązaniem jest system modułowy oszczędzający przestrzeń roboczą, materiały oraz ograniczający potencjalne nieszczelności układu. W pracy przedstawiono analizę stanu możliwości wykorzystania pomp ciepła w układzie grzewczo-chłodniczym samochodu wraz z problemami dotyczącymi tego rodzaju systemu.
In recent years, the development of passenger vehicles is focused on ecological solutions, often based on electric drive. The use of electric propulsion technology in vehicles changes the principles of heating and cooling the passenger area. An addition aspect is the maintenance of proper working conditions of batteries supplying the vehicle. This makes it necessary to change the solutions in the heating and cooling system. The systems used in internal combustion cars use excess temperature, extracting heat and transferring them to the passenger cabin. Cooling takes place using a refrigerant circuit, driven by a compressor that loads the vehicle engine. Electric cars, due to the limited access to energy storage and the visible impact of additional devices on the driving range, require efficient and cost-effective solutions. Due to the complexity of the requirements for air conditioning, solutions known from the application of heat pumps in construction are being introduced. Solutions of this type allow to relieve electric heaters by taking heat from the outside. All solutions have a diffuse character, i.e. the elements of the system are built in different parts of the vehicle. An innovative solution is a modular system that saves working space, materials and reduces potential system leaks. The article presents an analysis of the state of the possibilities of using heat pumps in the heating and cooling system of the car with problems regarding the solutions.
Źródło:
Proceedings of ECOpole; 2018, 12, 2; 473-482
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of the Alternative Energy Sources in Heating and Air-Conditioning Installations
Wykorzystanie alternatywnych źródeł energii w instalacjach grzewczo-klimatyzacyjnych
Autorzy:
Cholewa, T.
Guz, Ł.
Siuta-Olcha, A.
Powiązania:
https://bibliotekanauki.pl/articles/388097.pdf
Data publikacji:
2010
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
alternatywne źródła energii
kolektory słoneczne
absorpcyjna pompa ciepła
sprężarkowa pompa ciepła
alternative energy sources
solar collectors
absorptive heat pump
air-compressor heat pump
Opis:
One of the most important problems of last years is the development of society, which is not compatible with environment protection. Total consumption of energy does not reflect already the degree of economic development. The index of scientifical and technical progress is nowadays the minimization of the energy consumption and its ecological cleanness. Additionally growing prices of energy carriers, the environmental degradation and climate changes make alternative energy sources interesting. Alternative energy sources can be used not only for room heating but also for its cooling. The connection these both functions by means of 4 different ideas of the heating and air-conditioning installation for the existing auditorium is presented. In the first idea main devices are solar collectors, air-compressor heat pump, the underground heat magazine filled with stones and a water, and ground probes. The second solution introduces the connection into one system of solar collectors, the air-compressor heat pump, the triple hydraulical coupling and ground probes. Into the third solution entered ground probes, solar collectors, absorptive heat pump and the gas boiler. The main elements of the fourth solution are compact heating and cooling devices and solar collectors, which work with warm water tank. The technological schema with well-chosen devices are presented and the special attention on advantages and disadvantages of each solutions is paid. Besides for solution III and IV capital costs, the annual conventional fuel consumption on needs of the heatings, emissions of pollutions to the atmosphere and savings resulting from the use of alternative sources energy were calculated.
Jednym z ważniejszych problemów ostatnich lat jest pogodzenie rozwoju cywilizacyjnego społeczeństwa ze środowiskiem naturalnym. Globalne zużycie energii nie odzwierciedla już dziś stopnia rozwoju gospodarczego, a wręcz odwrotnie. Wyznacznikiem postępu naukowo-technicznego danego kraju jest obecnie minimalizacja zużycia energii i jej ekologiczna czystość. Dodatkowo ciągle rosnące ceny nośników energii, degradacja środowiska naturalnego oraz zmiany globalne klimatu doprowadziły do wzrostu zainteresowania alternatywnymi źródłami energii. Alternatywne źródła energii można wykorzystywać zarówno do ogrzewania, jak i chłodzenia pomieszczeń. Połączenie tych obu funkcji zaprezentowano za pomocą 4 różnych koncepcji instalacji grzewczo-klimatyzacyjnych dla sali wykładowej. W pierwszej koncepcji głównymi urządzeniami są kolektory słoneczne, sprężarkowa pompa ciepła, podziemny magazyn ciepła wypełniony kamieniami i wodą oraz sondy gruntowe. Drugie rozwiązanie przedstawia połączenie w jeden układ kolektorów słonecznych, sprężarkowej pompy ciepła, trójdzielnego sprzęgła hydraulicznego oraz sond gruntowych. W skład trzeciego rozwiązania weszły sondy gruntowe, kolektory słoneczne, absorpcyjna pompa ciepła oraz kocioł gazowy. Natomiast głównymi elementami czwartego rozwiązania są kompaktowe urządzenia grzewczo-chłodzące, kolektory słoneczne współpracujące z biwalentnym podgrzewaczem wody. Zaprezentowano schematy technologiczne z dobranymi urządzeniami oraz zwrócono uwagę na wady i zalety poszczególnych rozwiązań. Ponadto dla rozwiązania III oraz IV obliczono koszty inwestycyjne, roczne zużycie paliwa konwencjonalnego, emisje zanieczyszczeń do atmosfery oraz oszczędności, które wynikają z wykorzystania odnawialnych źródeł energii.
Źródło:
Ecological Chemistry and Engineering. A; 2010, 17, 11; 1473-1481
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessing the applicability of new refrigerants in marine cooling systems
Autorzy:
Zakrzewski, B.
Łokietek, T.
Powiązania:
https://bibliotekanauki.pl/articles/259543.pdf
Data publikacji:
2010
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
TEWI
ODP
GWP
heat pump
air conditioning
cooling installations
refrigerant
R22 substitute
energetic efficiency
R41
R152a
R218
R227ea
RC318
R600a
R290
R1270
Opis:
The article assesses the applicability of new refrigerants, being possible substitution for Freon 22, in marine refrigeration and air-conditioning systems. A collection of technical data on the physical properties of the new refrigerants is presented. Suggestions are made about certain energetic and ecological profits which can be gained when using energetically efficient refrigerants with low GWP values. The results of the TEWI comparison analysis for selected refrigerants are also included.
Źródło:
Polish Maritime Research; 2010, 2; 55-59
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka aktywnych i pasywnych systemów chłodzenia za pomocą pompy ciepła
Characteristics of passive or active cooling systems by means of heat pump
Autorzy:
Piszczatowska, U.
Żukowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/403053.pdf
Data publikacji:
2010
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
rewersyjna pompa ciepła
chłodzenie aktywne
chłodzenie pasywne
moduł klimatyzacyjny
geothermal heat pump
active cooling
passive cooling
air conditioning unit
Opis:
Geotermalne pompy ciepła są to urządzenia, które w okresie grzewczym wykorzystują ciepło gruntu jako tzw. źródło dolne do celów centralnego ogrzewania i ciepłej wody użytkowej. W artykule skupiono się jednak na temacie wykorzystania tego urządzenia do chłodzenia pomieszczeń w okresie letnim. Realizacja tego zamierzenia może odbywać się w trybie pasywnym bądź aktywnym. W pierwszym przypadku chłodzenie odbywa się przy bezpośrednim wykorzystaniu chłodu wody lub gruntu. Nie zużywa się przy tym energii na pracę sprężarki. Druga opisana w artykule możliwość to realizacja chłodzenia przy użyciu klimakonwektorów bądź ogrzewania płaszczyznowego. Scharakteryzowano również zintegrowany układ grzewczo-chłodniczy zainstalowany w budynku biurowym, w skład którego wchodzą wymienniki ciepła, pompa ciepła oraz moduł klimatyzacyjny HPAC.
Geothermal heat pumps are devices which use energy from the ground as an upper heat source for central heating and domestic hot water systems during the heating period. The first part of the paper focuses on applying these devices for the cooling of rooms in summertime. Implementation of this technology can be done in two cooling modes: passive or active. In the first case cooling is carried out by the direct use of cold water or soil. In this particular case there is no power consumption by compressor. The second possibility of implementation of cooling can be obtained by fan coil units or underfloor heating systems. The second part of the paper characterizes the integrated heating-cooling system, which is installed in the office building near Białystok. This system consists of heat exchangers, heat pump and air conditioning unit HPAC. System under consideration can operate both in the heating mode and as the passive and active cooling unit. This solution guarantees thermal comfort throughout all the year.
Źródło:
Budownictwo i Inżynieria Środowiska; 2010, 1, 3; 241-244
2081-3279
Pojawia się w:
Budownictwo i Inżynieria Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Critical analysis of the functioning of test benches dedicated to testing heat pumps in electric vehicles
Krytyczna analiza funkcjonowania stanowisk badawczych przeznaczonych do badania pomp ciepła w pojazdach elektrycznych
Autorzy:
Grygierzec, Jan
Werle, Sebastian
Powiązania:
https://bibliotekanauki.pl/articles/1819540.pdf
Data publikacji:
2020
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
heat pump
air conditioning
test bench
electric vehicle
pompa ciepła
klimatyzacja
stanowisko testowe
pojazd elektryczny
Opis:
Changes in the automotive industry to bring more electric and hybrid cars to market have a significant impact on the type of heating and cooling systems for vehicles. The work done so far in this area shows the considerable impact of these systems on vehicle coverage. This is due, among other things, to the fact that air conditioning systems in electric and hybrid cars have additional tasks, such as keeping the battery temperature at the right temperature. Studies also show that heating and cooling systems based on heat pump systems have the highest efficiency. The development of such systems, however, depends on a properly planned test phase under widely varying boundary conditions. Such research allows to limit the negative impact of heating and cooling systems on the range of electric cars under real operating conditions and can contribute significantly to the popularity of electric vehicles. The aim of this work is to develop a test bench concept for testing heat pumps used in electric vehicles. The impact of the assumed boundary conditions on individual system components is presented. On the basis of two examples of test stands, a critical assessment of the effectiveness of the applied methodology was made. Differences in individual systems were indicated, and the own concept of the test bench for testing heat pumps for variable input parameters was presented.
Źródło:
Ecological Chemistry and Engineering. A; 2020, 27, 1-2; 1-10
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficiency of heat pump systems of air conditioning for removing excessive moisture
Autorzy:
Bezrodny, Mikhail
Prytula, Natalia
Tsvietkova, Maria
Powiązania:
https://bibliotekanauki.pl/articles/240821.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heat pump
air conditioning systems
comfortable conditions
production facilities with excess moisture
pompa grzejna
systemy klimatyzacji
wilgoć
Opis:
The conditions of efficient use of heat pumps in air conditioning systems are considered in order to ensure the established temperature and relative humidity of air in premises with the removal of excess moisture in the warm or hot periods of the year. For this purpose, a thermodynamic analysis of heat pump air conditioning schemes with exhaust air recirculation through a condenser and through a heat pump evaporator has been carried out. To determine the potential capabilities of such schemes to maintain comfortable conditions in the production room, a numerical analysis of their operating parameters, depending on the temperature and relative humidity of external atmospheric air, was performed. It has been shown that recirculation of exhaust air through the heat pump evaporator allows to maintain the given conditions in the room in a wider range of parameters of external atmospheric air. In addition, it has been shown that such a scheme requires less specific energy consumption for the operation of heat pump, which means that it is more efficient.
Źródło:
Archives of Thermodynamics; 2019, 40, 2; 151-165
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena efektywności ekonomicznej wykorzystania pomp ciepła do pokrycia potrzeb cieplnych obiektów w średniej wielkości oczyszczalni ścieków
Evaluating the economic efficiency of using heat pumps to cover the heat energy requirements in middle-size sewage treatment plants
Autorzy:
Szul, T.
Powiązania:
https://bibliotekanauki.pl/articles/238811.pdf
Data publikacji:
2008
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
oczyszczalnia ścieków
ścieki
pompa ciepła
ogrzewanie
klimatyzacja
sewage treatment plant
sewage
heat pump
heating
air conditioning
Opis:
Dokonano analizy celowości wykorzystania ciepła odpadowego ze ścieków oczyszczonych przy wykorzystaniu pomp ciepła do pokrycia potrzeb cieplnych oraz klimatyzacyjnych w obiektach w oczyszczalni ścieków. Rozpatrzono cztery warianty wykorzystania pomp ciepła w obiektach oczyszczalni, charakteryzujące się różnym stopniem pokrycia ich potrzeb cieplnych. Zastosowanie pomp ciepła w systemie grzewczym pozwala na pokrycie potrzeb cieplnych w zależności od przyjętego wariantu od ok. 10% do ok. 85%. Roczne oszczędności oczyszczalni z tytułu zastosowania pomp ciepła do ogrzewania obiektów w zależności od zastosowanego wariantu mogą wynieść 12-60%. Aby móc wybrać najlepszą z proponowanych opcji, przeprowadzono analizę finansową przedsięwzięcia, w której porównano nakłady inwestycyjne z korzyściami, jakie mogą one przynieść po wdrożeniu danego wariantu do realizacji.
Purposefulness of using waste heat from purified sewage by means of the heat pumps, to cover the heat energy and conditioning requirements in sewage treatment plant, was analysed. Four variants of heat pump application in the objects of sewage treatment plant were considered as characterized by different levels of covering heat energy requirements. Using of the heat pumps in a heating system enables - depending on the variant assumed - to cover from 10 to almost 85% of heat energy requirements. The annual savings of sewage treatment plant owing to heat pumps' use to heating the objects may range within 12-60%, depending on the variant applied. To select the optimum from proposed options the financial analysis of the project was carried out, where the investment outlays were compared with potential profits possible to obtain as a result of implementing given variant to realization.
Źródło:
Problemy Inżynierii Rolniczej; 2008, R. 16, nr 3, 3; 125-136
1231-0093
Pojawia się w:
Problemy Inżynierii Rolniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Operational research of ground heat pump and passive air conditioning
Badania eksploatacyjne gruntowej pompy ciepła i klimatyzacji pasywnej
Autorzy:
Gil, P.
Gałek, R.
Kiedrzyński, K.
Kmieciński, A.
Powiązania:
https://bibliotekanauki.pl/articles/195054.pdf
Data publikacji:
2018
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
passive air conditioning
heat pump
ground heat exchanger
klimatyzacja pasywna
pompa ciepła
gruntowy wymiennik ciepła
Opis:
This article presents a passive air conditioning system using the lower source of the ground heat pump. Passive air conditioning uses the natural cold accumulated in the ground especially in the summer season. A hydraulic diagram and the principle of passive air conditioning were presented in the text. The purpose of the measurement was to determine the cooling power, the characteristic temperatures and the soil temperature distribution at the depth of 2 meters at the ground excavated site of the spiral ground heat exchanger. Annual temperature distributions in the ground which directly affect annular cooling power were presented. Advantages and disadvantages of passive air conditioning have also been presented.
W artykule przedstawiono wyniki badań eksploatacyjnych gruntowej pompy ciepła i pasywnego układu klimatyzacji. Pasywna klimatyzacja wykorzystuje dolne źródło gruntowej pompy ciepła oraz naturalne zimno zgromadzone w ziemi, szczególnie w sezonie letnim. W tekście przedstawiono schemat hydrauliczny i zasadę działania pasywnej klimatyzacji. Celem pomiaru było określenie mocy chłodniczej, charakterystycznych temperatur i rozkładu temperatury w gruncie na głębokości 2 m w miejscu zakopania gruntowego wymiennika ciepła. Przedstawiono roczne rozkłady temperatury w gruncie, które bezpośrednio wpływają na uzyskaną moc chłodniczą. Przedstawiono zalety i wady zaprezentowanej pasywnej klimatyzacji.
Źródło:
Zeszyty Naukowe Politechniki Rzeszowskiej. Mechanika; 2018, z. 90 [298], 2; 153-162
0209-2689
2300-5211
Pojawia się w:
Zeszyty Naukowe Politechniki Rzeszowskiej. Mechanika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Parametric study of fluid flow and heat transfer over louvered fins of air heat pump evaporator
Autorzy:
Muszyński, T.
Kozieł, S. M.
Powiązania:
https://bibliotekanauki.pl/articles/240658.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heat exchangers
heat transfer intensification
CFD
convection
air source heat pump
wymienniki ciepła
intensyfikacja wymiany ciepła
konwekcja
powietrzne pompy ciepła
Opis:
Two-dimensional numerical investigations of the fluid flow and heat transfer have been carried out for the laminar flow of the louvered fin-plate heat exchanger, designed to work as an air-source heat pump evaporator. The transferred heat and the pressure drop predicted by simulation have been compared with the corresponding experimental data taken from the literature. Two dimensional analyses of the louvered fins with varying geometry have been conducted. Simulations have been performed for different geometries with varying louver pitch, louver angle and different louver blade number. Constant inlet air temperature and varying velocity ranging from 2 to 8 m/s was assumed in the numerical experiments. The air-side performance is evaluated by calculating the temperature and the pressure drop ratio. Efficiency curves are obtained that can be used to select optimum louver geometry for the selected inlet parameters. A total of 363 different cases of various fin geometry for 7 different air velocities were investigated. The maximum heat transfer improvement interpreted in terms of the maximum efficiency has been obtained for the louver angle of 16° and the louver pitch of 1.35 mm. The presented results indicate that varying louver geometry might be a convenient way of enhancing performance of heat exchangers.
Źródło:
Archives of Thermodynamics; 2016, 37, 3; 45-62
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Possibilities of heating and air-conditioning of buildings in the mountain areas
Autorzy:
Gonet, A.
Śliwa, T.
Powiązania:
https://bibliotekanauki.pl/articles/100410.pdf
Data publikacji:
2014
Wydawca:
Uniwersytet Rolniczy im. Hugona Kołłątaja w Krakowie
Tematy:
heating and air conditioning of buildings
borehole heat exchangers
heat pump
mountain areas
geoenergetics
ogrzewanie budynków
klimatyzacja budynków
wymiennik ciepła
pompa ciepła
geoenergetyka
Opis:
The mountain areas, due to their specificity, require special approach to issues concerning heating and air-conditioning of buildings. After presenting general information on demand for heat in a standard residential building, the forecasting of demand for final energy by particular branches of economy has been presented. Fossil fuels are most commonly used in heating buildings. In this kind of systems the heat is supplied to the consumer by means of heating pipes provided by heat power stations or combined heat and power stations or it is generated in boilers owned by the consumers. The remote heat source can also be energy from geothermal power station, as it is in the Podhale region. There is an alternative solution to these systems in the form of heat pumps that are often connected to borehole heat exchangers. Depending on the energy balance of the heating system and air-conditioning of a particular building the latter system can be additionally aided by solar collectors. This method requires only a power service connection, which is available almost in every building. Moreover, practical uses of the proposed system, which should be more widely applied in the mountain areas, have been described.
Źródło:
Geomatics, Landmanagement and Landscape; 2014, 3; 55-63
2300-1496
Pojawia się w:
Geomatics, Landmanagement and Landscape
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Powietrzne pompy ciepła w audytach energetycznych
Air source heat pump’s in energy audits
Autorzy:
Gużda, A.
Szmolke, N.
Powiązania:
https://bibliotekanauki.pl/articles/2065534.pdf
Data publikacji:
2018
Wydawca:
Politechnika Częstochowska
Tematy:
powietrzna pompa ciepła
audyt energetyczny
efektywność
współczynnik COP
air source heat pump
energetic audit
efficiency
coefficient of performance
Opis:
Pompy ciepła, ze względu na wysoki współczynnik efektywności działania (COP, ang. coefficient of performance), często wybierane są jako wariant przedsięwzięcia mającego na celu poprawę efektywności energetycznej w budynku. W niniejszym artykule przedstawiony został jeden z obecnie najbardziej efektywnych sposobów wytwarzania ciepłej wody użytkowej i ogrzewania budynków, jakim jest zastosowanie powietrznej pompy ciepła. Zaprezentowano zasadę działania takiego urządzenia w instalacji oraz główne parametry wpływające na ich efektywność. Ponadto omówiono zasadność stosowania pomp ciepła, w ujęciu wyboru ich jako wariant przedsięwzięcia termomodernizacyjnego. Omówione zostały zagadnienia związane z prawidłowym doborem urządzenia na etapie obliczeń audytorskich. W końcowej części pracy, autorzy przedstawili przykład obliczeniowy doboru powietrznej pompy ciepła w audycie energetycznym, wraz z określeniem efektu ekologicznego zastosowania tego przedsięwzięcia.
Paper presents one of the most efficient ways of producing hot water and heating of buildings is the present one, which is the use of an air heat pump. They are often chosen to improve energy efficiency in a building. The principle of operation and main parameters influencing their effectiveness were presented. In addition, the use of heat pumps has been discussed in terms of their choice as a variant in energetic audit. The problems related to the correct device selection at the stage of the audit calculations were discussed. In the final part of the paper, the authors presented a computational example of the air-to-water heat pump selection in the energy audit. Moreover the ecological analysis related to different source of energy in building was presented.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2018, 7, 2; 74--80
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research to estimate energy efficiency of a ventilation and air conditioning heat pump system inside a production premise with ventilation air recovery
Autorzy:
Bezrodny, Myhailo Kostiantynovych
Misiura, Tymofii Oleksiyovych
Powiązania:
https://bibliotekanauki.pl/articles/1955060.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
air conditioning
heat pump system
refrigeration efficiency
recuperation
Opis:
The research provides a thermodynamic analysis of the theoretical model of a ventilation and air conditioning heat pump system with the ventilation air cold energy recovery depending on outside air parameters, the recovery efficiency and characteristics of a premise. A confectionery production workshop was taken as a prototype where technological conditions (temperature and humidity) must be maintained during the warm season. Calculations using the method of successive approximations to estimate air parameters at system’s nodal points were conducted. It allowed to determine theoretical refrigeration efficiency of the studied system and proved advantages of heat recuperation for smaller energy consumption. The model can be applied for design of heating, ventilation, and air conditioning units which work as a heat pump. The studied system has the highest energy efficiency in the area of relatively low environment temperatures and relative humidity which is suitable for countries with temperate continental climates characterized by low relative humidity.
Źródło:
Archives of Thermodynamics; 2021, 42, 4; 69-86
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies