Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "aeration tank" wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
Wastewater Treatment Methods and Sewage Treatment Facilities in Almaty, Kazakhstan
Autorzy:
Ospanov, Kairat
Kuldeyev, Erzhan
Kenzhaliyev, Bagdaulet
Korotunov, Anatoly
Powiązania:
https://bibliotekanauki.pl/articles/2025747.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
wastewater
sedimentation tank
aeration tank
water quality
wastewater storage
Opis:
The results of comprehensive research on the status of sewage treatment in Almaty are presented in this article. The results of the reconstruction and modernization of treatment facilities intended to improve the sewage treatment efficiency, including the results of pretreatment of wastewater with excess sludge in the primary clarification tank, and the results of hydrobiological and microbiological analysis of activated sludge in the aeration tank are presented. The analysis of the study results of the chemical composition of incoming, clarified and treated wastewater is presented. Besides, the results of the analysis of the water balance of wastewater are presented.
Źródło:
Journal of Ecological Engineering; 2022, 23, 1; 240-251
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Исследование влияния аэрации на показатели сточных вод и активного ила на выходе из аэротенка
Investigation of the influence on the performance of aeration of waste water and activated sludge from the aeration tank outlet
Issledovanie vlijanija aehracii na pokazateli stochnykh vod i aktivnogo ila na vykhode iz aehrotenka
Autorzy:
Gornostal', S.
Petukhova, E.
Ajjrapetjan, T.
Powiązania:
https://bibliotekanauki.pl/articles/952732.pdf
Data publikacji:
2015
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
aeration
waste water
waste water treatment
aeration tank
biological treatment
Źródło:
Motrol. Motoryzacja i Energetyka Rolnictwa; 2015, 17, 6
1730-8658
Pojawia się w:
Motrol. Motoryzacja i Energetyka Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Radiotracer investigation of a pulp and paper mill effl uent treatment plant
Autorzy:
Sarkar, M.
Sangal, V. K.
Bhunia, H.
Bajpai, P. K.
Pant, H. J.
Sharma, V. K.
Kumar, A.
Naithani, A. K.
Powiązania:
https://bibliotekanauki.pl/articles/147197.pdf
Data publikacji:
2017
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
aeration tank
secondary clarifier
residence time distributions
RTD
radiotracer
convolution
Opis:
The pulp and paper industry is highly dependent on water for most of its processes, producing a significant amount of wastewater that should be treated to comply with environmental standards before its discharge into surface-water reservoirs. The wastewater generated primarily consists of substantial amounts of organic, inorganic, toxic and pathogenic compounds in addition to nutrients, which are treated in an effluent treatment plant that often combines primary, secondary, tertiary and advanced treatments. However, the treatment methods vary from industry to industry according to the process utilized. The effective performance of effluent treatment plants is crucial from both environmental and economic points of view. Radiotracer techniques can be effectively used to optimize performance and detect anomalies like dead zones, bypassing, channelling, etc. in wastewater treatment plants. Experiments on the distribution of residence time were performed on the aeration tank and secondary clarifier of a full-scale pulp and paper mill to study the flow behaviour as well as locate system anomalies and hence evaluate the performance of the treatment plants using the radiotracer I-131. The convolution method was applied to model the system with an imperfect impulse radiotracer input. The aeration tank was working efficiently in the absence of any dead zones or bypassing. Various hydrodynamic models available in the literature were applied on the aeration tank and secondary clarifier to obtain the hydraulic representation of the systems.
Źródło:
Nukleonika; 2017, 62, 4; 289-294
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Technology of Wastewater Treatment Production of Vegetable Oils and Fats and Evaluation of Aeration Tank Efficiency on the Basis of Microanalysis of Activated Sludge
Autorzy:
Korotkova, Tatyana Germanovna
Altukhova, Darya Vladimirovna
Istoshina, Natalya Yurevna
Demin, Vladimir Ivanovich
Powiązania:
https://bibliotekanauki.pl/articles/123766.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
monitoring
wastewater
aeration tank
microorganisms
activated sludge
production
vegetable oils
fats
Opis:
This article discusses the main stages and features of wastewater treatment at “Food Ingredients” LLC (Russia, Krasnodar region) involved in vegetable oils and fats refining. The experimental data on averaged qualitative composition of industrial wastewater involving the period from January to June, 2018 were presented. The indicators of the quality of averaged waste did not exceed: 20 mg/l for ammonium nitrogen; 20 mg/l for phosphates; 800 mg/l for suspended solids; 700 mg/l for fatty substances. The operation of biological aeration tank was analyzed from January to June, 2018. The graphic dependences of the change of sludge index, phosphate ions, chemical oxygen demand (COD), and temperature were given. The species composition of microorganisms and their amount were determined by means of optical microscopy. Absolute quantity of microorganisms in activated sludge was determined with the “calibrated droplet” method. As of October 31, 2018 the quantity of microorganisms was as follows, U/ml: small flagellates – 44,015; free swimming infusoria – 34,233; Euglypha – 6,520; Vorticella – 27,713; Rotatoria – 29,343; Aspidiska – 36,950; Aelosoma – 2,173; Heliozoa – 1,086. No filamentous microorganisms were detected. After treatment, the recovered water was characterized by the following indicators of the quality: transparent, ammonium nitrogen content in water was less than 0.1 mg/l, phosphate ion content was no higher than 0.2 mg/l; COD was no higher than 30 mg O2/l, hydrogen index was about pH = 7. These indicators comply with the requirements for water in technical water supply systems of industrial enterprises (Russia), as applied to recovered water produced of wastewater for subsequent use in recycled water supply system. The treated water is reused in the production processes, which evidences high quality of water treatment and reliable operation of the equipment in local treatment facilities at “Food Ingredients” LLC during 10 years of operation.
Źródło:
Journal of Ecological Engineering; 2019, 20, 7; 70-78
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Błędy projektowe i wykonawcze jako przyczyna uszkodzeń dwóch zbiorników – komór napowietrzania ścieków znajdujących się na terenie oczyszczalni ścieków w Grodzisku Wielkopolskim
Design and building process mistakes as the cause of damages of two tanks – aeration chambers of sewage located on the area of sewage treatment plant in Grodzisk Wielkopolski
Autorzy:
Przybyłowicz, E.
Pikos, M.
Powiązania:
https://bibliotekanauki.pl/articles/161615.pdf
Data publikacji:
2017
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
oczyszczalnia ścieków
zbiornik na ścieki
komora napowietrzania
konstrukcja żelbetowa
stan techniczny
spękanie ścian
analiza przyczyn
błąd projektowania
błąd wykonawstwa
wastewater treatment plant
sewage tank
aeration chamber
reinforced concrete structure
technical condition
wall cracking
causes analysis
design fault
execution fault
Opis:
W pracy omówiono przyczyny uszkodzeń ścian dwóch zbiorników – komór napowietrzania ścieków znajdujących się na terenie modernizowanej oczyszczalni ścieków w Grodzisku Wlkp. Zasadniczą przyczyną powstałych uszkodzeń było niewłaściwe rozmieszczenie dylatacji w ścianach zbiorników, zbyt małe zbrojenie poziome ścian niezabezpieczające ich przed wpływem skurczu betonu i zmian temperatury, zła jakość betonu oraz prowadzone roboty budowlane związane z budową w pobliżu nowego zbiornika. Po przeanalizowaniu kosztów naprawy zbiorników stwierdzono, że najbardziej racjonalnym rozwiązaniem będzie ich rozbiórka i budowa nowych obiektów z zachowaniem zasad współczesnej wiedzy technicznej, a do czasu podjęcia tych prac doraźne uszczelnienie spękanych ścian i ich lokalne wzmocnienie.
Present paper discusses the causes of damage of walls of two tanks – aeration chambers of wastewater located in the area of modernized sewage treatment plant in Grodzisk Wlkp. The main cause of the damage was improper location of dilatation in the tank walls, too low reinforcement of horizontal walls not protect them against the effect of concrete shrinkage and temperature changes, bad concrete quality and building work carried out near the new tank. After analyzing the costs of repairing tanks, it was found that the most rational solution would be their dismantling and construction of new facilities according to principles of modern technical knowledge. The temporary sealing of cracked walls and their local reinforcement will be applied until repair works are done.
Źródło:
Przegląd Budowlany; 2017, 88, 9; 89-92
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies