Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "active noise control" wg kryterium: Temat


Tytuł:
Feedforward Control of a Light-Weight Device Casing for Active Noise Reduction
Autorzy:
Wrona, S.
Pawelczyk, M.
Powiązania:
https://bibliotekanauki.pl/articles/177744.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
active control
flexible structures
active noise control
active vibration control
active structural acoustic control
active casing
Opis:
It is possible to enhance acoustic isolation of the device from the environment by appropriately controlling vibration of a device casing. Sound insulation efficiency of this technique for a rigid casing was confirmed by the authors in previous publications. In this paper, a light-weight casing is investigated, where vibrational couplings between walls are much greater due to lack of a rigid frame. A laboratory setup is described in details. The influence of the cross-paths on successful global noise reduction is considered. Multiple vibration actuators are installed on each of the casing walls. An adaptive control strategy based on the Least Mean Square (LMS) algorithm is used to update control filter parameters. Obtained results are reported, discussed, and conclusions for future research are drawn.
Źródło:
Archives of Acoustics; 2016, 41, 3; 499-505
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Review of active noise control algorithms for impulsive noise control
Przegląd algorytmów aktywnej redukcji hałasu impulsowego
Autorzy:
Wierzchowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/154599.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
active noise control
impulsive noise
FxLMS
FxLMP
FxLogLMS
aktywna redukcja hałasu
hałas impulsowy
Opis:
Active noise control is gaining popularity in recent years. Especially, active control of impulsive noise is of great interest. Due to specific nature of such noise, standard approach to active control is not satisfying. This paper reviews existing algorithms specifically developed for impulsive noise control. Performance of the algorithms is verified using computer simulations and several noise signals.
Aktywna redukcja hałasu zyskuje na popularności w ostatnich latach. Z powodu specyfiki hałasu impulsowego, standardowe podejście do aktywnej redukcji nie jest zadawalające. Niniejsza praca przedstawia algorytmy stworzone specjalnie na potrzeby redukcji hałasu impulsowego, który ze względu na swoją specyfikę nie jest poprawnie tłumiony przez klasyczne algorytmy redukcji hałasu. W pierwszym punkcie przedstawiona jest ogólnie idea aktywnej redukcji hałasu. W drugim punkcie opisany jest hałas impulsowy: charakterystyka, wpływ na człowieka oraz technika modelowania. W trzecim punkcie przedstawiony został podstawowy algorytm aktywnej redukcji hałasu oraz jego modyfikacje stworzone do aktywnej redukcji hałasu impulsowego. W czwartym punkcie przedstawione zostały wyniki porównujące przedstawione algorytmy. Porównanie algorytmów wykonane zostało za pomocą symulacji komputerowej z wykorzystaniem modeli rzeczywistych torów akustycznych oraz dwóch rodzajów hałasu: modelowanego i rzeczywistego nagrania. W ostatnim punkcie zostały przedstawione wnioski z prezentowanej pracy.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 6, 6; 358-361
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rotorcraft thickness noise control
Autorzy:
Szulc, O.
Powiązania:
https://bibliotekanauki.pl/articles/38627396.pdf
Data publikacji:
2021
Wydawca:
Instytut Podstawowych Problemów Techniki PAN
Tematy:
helicopter rotor
aerodynamics
aeroacoustics
CFD
noise reduction
active flow
noise control
surface transpiration
perforation
Opis:
The paper describes an innovative idea of Thickness Noise Control (TNC) based on adoption of a flow control strategy (i.e. surface ventilation) for acoustic attenuation of helicopter rotor periodic noise. The TNC method is relying on incorporation of multiple cavities (closed by perforated panels and linked to low- and high-pressure reservoirs) located in a symmetrical manner at front and rear portions of the blade tip. The efficiency of the new approach is verified using a two-bladed model rotor of Purcell (untwisted variant of the blade of Bell UH-1H Iroquois helicopter) in low-thrust hover conditions. The results of numerical simulations, obtained with CFD solver (Spalart–Allmaras turbulence and Bohning–Doerffer transpiration models), indicate that in the near-field of the blade tip, both the amplitude and spectral contents of pressure impulses of emitted thickness noise are significantly improved. The TNC method, in the proposed unsteady mode of operation, turns out to be a suitable means of thickness noise reduction in forward flight. Moreover, it is demonstrated that by proper azimuthal activation the efficiency is almost unaltered, while the rotor torque penalty and required transpiration mass-flux are decreased by a factor of 3–5 compared to a steady arrangement.
Źródło:
Archives of Mechanics; 2021, 73, 4; 391-417
0373-2029
Pojawia się w:
Archives of Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Quiet Zone for the patient in an Ambulance : Active Noise Control Technology for Siren Noise Reduction
Autorzy:
Sharma, M. K.
Vig, R.
Pal, R.
Shantharam, V.
Powiązania:
https://bibliotekanauki.pl/articles/177099.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
active noise control
ANC
virtual sensing technique
ambulance siren noise
zone of silence
feedforward ANC
virtual ANC
Opis:
This paper proposes an active noise control (ANC) application to attenuate siren noise for the patient lying inside ambulance with no sound proofing. From the point of cost effectiveness, a local ANC system based on feedforward scheme is considered. Further, to handle the limitation of limited Zone of Silence (ZoS), the ANC based on virtual sensing is explored. The simulations are done in MATLAB for the recorded ambulance siren noise signal. The results indicate that ANC can be an effective solution for creating a silent environment for the patient.
Źródło:
Archives of Acoustics; 2018, 43, 2; 275-281
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Earplug Actuator Selection for a Miniature Personal Active Hearing Protection System
Autorzy:
Pawełczyk, M.
Latos, M.
Powiązania:
https://bibliotekanauki.pl/articles/178052.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
active noise control
fixed-parameter control
high-level noise
nonstationary noise
feedforward control
earplug
hearing protection
Opis:
There are many industrial environments which are exposed to a high-level noise. It is necessary to protect people from the noise. Most of the time, the consumer requires a miniature version of a noise canceller to satisfy the internal working place requirements. Very important thing is to select the most appropriate personal hearing protection device, for example an earplug. It should guarantee high passive noise attenuation and allow for secondary sound generation in case of active control. In many cases the noise is nonstationary. For instance, some of the noisy devices are switched on and off, speed of some rotors or fans changes, etc. To avoid any severe transient acoustic effects due to potential convergence problems of adaptive systems, a fixed-parameter approach to control is appreciated. If the noise were stationary, it would be possible to design an optimal control filter minimising variance of the signal being the effect of the acoustic noise and the secondary sound interference. Because of noise nonstationarity for most applications, the idea of generalised disturbance defined by a frequency window of different types has been developed by the authors and announced in previous publications. The aim of this paper is to apply such an approach to different earplugs and verify its noise reduction properties. Simulation experiments are conducted based on real world measurements performed using the G.R.A.S. artificial head equipped with an artificial mechanical ear, and the noise recorded in a power plant.
Źródło:
Archives of Acoustics; 2010, 35, 2; 213-222
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Benchmarking of active noise control
Badania wzorcowe w aktywnym tłumieniu hałasu
Autorzy:
Ogonowski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/153427.pdf
Data publikacji:
2003
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
badania wzorcowe
aktywne tłumienie hałasu
active noise control
benchmarking
control system structures
identification
modelling
Opis:
The paper presents motivation for Active Control Benchmarking as well as the basic problems of the benchmarking. Emphasise is put on impossibility of experiment repetition. However, there are three elements being benchmarkable: structures of control systems, exciting signals and indices to compare results. Special attention is put on signals in the paper. Basing on real-world benchmark signals artificial exciting signals are proposed. The rules to generate them are: the same dynamical properties then in reality, Simplicity of generation and, possibility of parametrization. Ilustrative example is presented to describe the role of benchmarking.
W pracy przedstawiono zasady badań wzorcowych układów aktywnego tłumienia hałasu (ATH). Zwrócono uwagę na trudność powtarzalności eksperymentów. Wskazano jednak na trzy elementy układów ATH, dla których można prowadzić badania wzorcowe: struktury układów starowania w ATH, sygnały pobudzające i wskaźniki dla porównania wyników eksperymentów. Szczególną uwagę zwrócono na dobór sygnałów: wykorzystując zarejestrowane sygnały rzeczywiste zaproponowano odpowiedniki generowane sztucznie tak, aby zachować własności dynamiczne, przeprowadzić generację w łatwy sposób oraz zapewnić możliwość parametryzacji sygnałów. Badania zilustrowano odpowiednim przykładem.
Źródło:
Pomiary Automatyka Kontrola; 2003, R. 49, nr 11, 11; 8-11
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Aktywna redukcja hałasu niskoczęstotliwościowego w dźwiękoizolacyjnych kabinach przemysłowych
Active noise reduction of low frequency noise in industrial cabins
Autorzy:
Morzyński, L.
Powiązania:
https://bibliotekanauki.pl/articles/180042.pdf
Data publikacji:
2005
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
hałas
aktywna redukcja hałasu
hałas niskoczęstotliwościowy
słuchawki aktywne
kabina dźwiękoizolacyjna
noise
active noise control
low frequency noise
industrial cabin
Opis:
W artykule opisano system aktywnej redukcji hałasu w dźwiękoizolacyjnych kabinach przemysłowych. Przedstawione zostały trzy rozwiązania techniczne tego systemu. Pierwszym rozwiązaniem jest układ do tworzenia stref ciszy bazujący na dwóch głośnikach umieszczonych w narożnikach kabiny. Drugim rozwiązaniem jest aktywny ochronnik słuchu zbudowany na bazie lekkich słuchawek. Trzecim z przedstawionych rozwiązań jest aktywny zagłówek (dwa niewielkie głośniki umieszczone w górnej części oparcia fotela pracownika). W artykule przedstawiono i omówiono wyniki pomiarów skuteczności aktywnej redukcji hałasu z zastosowaniem każdego z tych trzech rozwiązań.
In this article a system for active noise reduction in industrial cabins is presented. Three different approaches for secondary source design and location are described. The first one is a traditional configuration of two loudspeakers located in the corners of a cabin to create quiet zones. The second approach is an active hearing protector built on the base of lightweight headphones. The third one is a kind of an active headrest (two small loudspeakers located just behind the operator’s chair). In the article the results of the measurements of the efficiency of active noise reduction for each approach are presented and discussed.
Źródło:
Bezpieczeństwo Pracy : nauka i praktyka; 2005, 1; 4-7
0137-7043
Pojawia się w:
Bezpieczeństwo Pracy : nauka i praktyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application and Neural Networks in Active Noise Reduction Systems
Autorzy:
Morzyński, L.
Makarewicz, G.
Powiązania:
https://bibliotekanauki.pl/articles/90886.pdf
Data publikacji:
2003
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
noise
active methods
control
neural network
hałas
ochrona przed hałasem
aktywna redukcja hałasu
sieci neuronowe
Opis:
Active noise reduction systems based on a control unit in the form of a finite impulse response filter assume the linearity of every single component. Neural networks, which have so far been seldom used in this field, are a kind of a filter with the ability to project nonlinear characteristics of an active noise reduction system. This paper presents some simulation research studies of active noise reduction systems based on neural networks. Also presented are results of the operation of systems with different levels of complexity as well as the influence of different parameters of a neural network and of the system itself on those results.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2003, 9, 3; 257-270
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Double Panel Structure for Active Control of Noise Transmission
Autorzy:
Morzyński, L.
Szczepański, G.
Powiązania:
https://bibliotekanauki.pl/articles/176968.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
noise
sound insulating enclosure
active structural acoustic control
virtual microphone
Opis:
Passive noise reduction means are commonly used to reduce noise in the industry but, unfortunately, their effectiveness is poor in the low frequency range. By applying active structural acoustic control to the enclosure walls significant improvement of the insulating properties in this frequency range can be achieved. In this paper a model of double panel structure with ASAC is presented. The structure consists of two aluminium plates separated by an air gap. Two inertial magnetoelectric actuators and two piezoceramic MFC sensors were used for controlling the structure. A multichannel FxLMS algorithm with virtual error microphone technique is used as a control algorithm. The signal of a virtual error microphone is extrapolated basing on signals from MFC sensors. Performance of this actively controlled structure for tonal signals at selected frequencies is presented in the article. During the study, a double panel structure was mounted on one wall of sound insulating enclosure located in an acoustic chamber. During the measurements local and global reduction of noise test signal was investigated.
Źródło:
Archives of Acoustics; 2018, 43, 4; 689-696
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dwupłytowa struktura aktywna do ograniczania transmisji hałasu przez obudowy i przegrody dźwiękoizolacyjne
Double-layered active structure for reducing noise transmission through sound insulating barriers
Autorzy:
Morzyński, L.
Krukowicz, T.
Powiązania:
https://bibliotekanauki.pl/articles/181117.pdf
Data publikacji:
2017
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
hałas
obudowa dźwiękoizolacyjna
akustyczno-strukturalna aktywna redukcja hałasu
mikrofon wirtualny
noise
sound insulation
sound insulation enclosure
active structural acoustic control
virtual microphone
Opis:
Obudowy dźwiękoizolacyjne są jednym i podstawowych środków technicznych, stosowanych powszechnie do ograniczania hałasu. Izolacyjność przegród pasywnych maleje jednak ze spadkiem częstotliwości dźwięku. Izolacyjność w zakresie niskich częstotliwości może być zwiększona poprzez zastosowanie aktywnych metod redukcji hałasu. W artykule przedstawiono budowę i zasadę działania dwupłytowej struktury aktywnej do ograniczania transmisji hałasu przez przegrody. Do sterowania przegrodą korzystano algorytm z ekstrapolacją sygnału błędu w oparciu o sygnały z przetworników drganiowych Przedstawiono wyniki badań struktury na stanowisku laboratoryjnym.
Sound insulating enclosures are a basic technical measure commonly used to reduce noise. Insulation of passive sound insulating barriers, however, decreases with a decrease in frequency. Insulation in the low frequency range can be increased by using active noise control methods. This article presents the structure and principle of operation of a double-layered active structure to limit the transmission of noise through barriers. An algorithm, which extrapolates the error microphone signal based on signals from the vibration transducers, is used for structure control. This article presents structure performance in laboratory conditions.
Źródło:
Bezpieczeństwo Pracy : nauka i praktyka; 2017, 10; 24-28
0137-7043
Pojawia się w:
Bezpieczeństwo Pracy : nauka i praktyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System aktywnej redukcji hałasu przenikającego przez przegrody szklane, wykorzystujący algorytm rotacyjny
The system of active control of noise filtering through glass partitions using round robin algorithm
Autorzy:
Morzyński, L.
Powiązania:
https://bibliotekanauki.pl/articles/179016.pdf
Data publikacji:
2017
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
hałas
izolacja akustyczna
przegroda szklana
aktywna redukcja hałasu
algorytm rotacyjny
noise
sound insulation
glass partition
active noise control
round robin algorithm
Opis:
Jedną z funkcji przegród szklanych, powszechnie stosowanych m.in. w budownictwie, jest ograniczanie hałasu. Przegrody takie charakteryzują się jednak małą izolacyjnością akustyczną dla dźwięków o niskich częstotliwościach. W artykule przedstawiono koncepcję wielokanałowego systemu aktywnej redukcji hałasu, umożliwiającego redukcję hałasu niskoczęstotliwościowego przenikającego przez przegrodę szklaną. System bazuje na sieci neuronowej, której uczenie realizuje zmodyfikowana wersja algorytmu wstecznej propagacji błędu wykorzystująca algorytm rotacyjny. Omówiono budowę i zasadę działania systemu, a także przedstawiono wyniki jego badań symulacyjnych.
One of the functions of glass partitions, commonly used in construction, is the reduction of noise. These partitions are characterized by low sound insulation for low frequencies. This article presents the concept of a multi-channel active noise control system that enables the reduction of low-frequency noise transmitted through the glass partition. The system is based on a neural network with the modified version of the back propagation algorithm using a round robin algorithm. The structure and principles of the system are discussed and the results of its simulations are presented.
Źródło:
Bezpieczeństwo Pracy : nauka i praktyka; 2017, 11; 21-25
0137-7043
Pojawia się w:
Bezpieczeństwo Pracy : nauka i praktyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Adaptacyjne układy sterowania tworzące strefy ciszy wokół poruszającego się mikrofonu
Adaptive control systems creating zones of quiet around moving error microphone
Autorzy:
Michalczyk, M. I.
Powiązania:
https://bibliotekanauki.pl/articles/156587.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
aktywna redukcja hałasu
adaptacyjne układy sterowania
algorytm LMS
active noise control
adaptive algorithms
LMS algorithm
parameterization
Opis:
Przedstawiono wyniki badań nad adaptacyjnymi układami aktywnej redukcji hałasu wykorzystywanymi do tworzenia stref ciszy wokół poruszającego się w pomieszczeniu mikrofonu. Pokazano, że w części przypadków zastosowanie adaptacyjnego algorytmu FX-LMS zapewnia poprawne działanie układu, czyli śledzenie przez wytworzoną strefę ciszy zmian położenia mikrofonu. W przypadku złożonych zakłóceń lub szerszego zakresu ruchu mikrofonu, koniecznym jest zastosowanie dodatkowych algorytmów bieżącej estymacji modelu obiektu sterowania.
The paper summarizes the novel research on a special class of digital sound processing systems with time varying sound sensor position, conducted in the Institute of Automatic Control, Silesian University of Technology, Gliwice, Poland. These are adaptive active noise control (ANC) systems creating zones of quiet around a microphone, position of which is being changed in enclosure. They use the LMS-based adaptive control algorithm which is parameterized with a model of the so called secondary path. The problem arises when the microphone position is changed during the ANC system operation, because the secondary path modelling errors occur . They, in some cases, can be coped by the adaptive control algorithm itself, however, in other cases an additional, on-line identification routine has to be used to update the secondary path model. These two situations are the subject of the presented research. The results of real world experiments showed that the zone of quiet can adaptively track the movement of the microphone if the LMS-based adaptive control algorithm is applied. However, if the noise is random and the spatial range of the microphone movement is wider, then the more complex algorithms have to be used, which is shown on the basis of simulation experiments, verified in the ANC laboratory.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 1, 1; 9-11
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
FXLMS with Multiple Error Switching for Active Noise-Cancelling Casings
Autorzy:
Mazur, Krzysztof
Wrona, Stanislaw
Chraponska, Anna
Rzepecki, Jaroslaw
Pawelczyk, Marek
Powiązania:
https://bibliotekanauki.pl/articles/176371.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
active noise control
adaptive control
active casing
Opis:
Passive noise reduction methods require thick and heavy barriers to be effective for low frequencies and those clasical ones are thus not suitable for reduction of low frequency noise generated by devices. Active noise-cancelling casings, where casing walls vibrations are actively controlled, are an interesting alternative that can provide much higher low-frequency noise reduction. Such systems, compared to classical ANC systems, can provide not only local, but also global noise reduction, which is highly expected for most applications. For effective control of casing vibrations a large number of actuators is required. Additionally, a high number of error sensors, usually microphones that measure noise emission from the device, is also required. All actuators have an effect on all error sensors, and the control system must take into account all paths, from each actuator to each error sensor. The Multiple Error FXLMS has very high computational requirements. To reduce it a Switched-Error FXLMS, where only one error signal is used at the given time, have been proposed. This, however, significantly reduces convergence rate. In this paper an algorithm that uses multiple errors at once, but not all, is proposed. The performance of various algorithm variants is compared using simulations with the models obtained from real active-noise cancelling casing.
Źródło:
Archives of Acoustics; 2019, 44, 4; 775-782
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Active noise control with a single nonlinear control filter for a vibrating plate with multiple actuators
Autorzy:
Mazur, K.
Pawełczyk, M.
Powiązania:
https://bibliotekanauki.pl/articles/176906.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
active noise-vibration control
active structural acoustic control
adaptive control
nonlinear control
Opis:
Vibrating plates can be used in Active Noise Control (ANC) applications as active barriers or as secondary sources replacing classical loudspeakers. The system with vibrating plates, especially when nonlinear MFC actuators are used, is nonlinear. The nonlinearity in the system reduces performance of classical feedforward ANC with linear control filters systems, because they cannot cope with harmonics generated by the nonlinearity. The performance of the ANC system can be improved by using nonlinear control filters, such as Artificial Neural Networks or Volterra filters. However, when multiple actuators are mounted on a single plate, which is a common practice to provide effective control of more vibration modes, each actuator should be driven by a dedicated nonlinear control filter. This significantly increases computational complexity of the control algorithm, because adaptation of nonlinear control filters is much more computationally demanding than adaptation of linear FIR filters. This paper presents an ANC system with multiple actuators, which are driven with a single nonlinear filter. To avoid destructive interference of vibrations generated by different actuators the control signal is filtered by appropriate separate linear filters. The control system is experimentally verified and obtained results are reported.
Źródło:
Archives of Acoustics; 2013, 38, 4; 537-545
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Active Noise-Vibration Control using the Filtered-Reference LMS Algorithm with Compensation of Vibrating Plate Temperature Variation
Autorzy:
Mazur, K.
Pawełczyk, M.
Powiązania:
https://bibliotekanauki.pl/articles/177469.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
active noise-vibration control
active structural acoustic control
adaptive control
gain scheduling
temperature influence
Opis:
Vibrating plates have been recently used for a number of active noise control applications. They are resistant to difficult environmental conditions including dust, humidity, and even precipitation. However, their properties significantly depend on temperature. The plate temperature changes, caused by ambient temperature changes or plate heating due to internal friction, result in varying response of the plate, and may make it significantly different than response of a fixed model. Such mismatch may deteriorate performance of an active noise control system or even lead to divergence of a model-based adaptation algorithm. In this paper effects of vibrating plate temperature variation on a feedforward adaptive active noise reduction system with the multichannel Filtered-reference LMS algorithm are examined. For that purpose, a thin aluminum plate is excited with multiple Macro-Fiber Composite actuators. The plate temperature is forced by a set of Peltier cells, what allows for both cooling and heating the plate. The noise is generated at one side of the plate, and a major part of it is transmitted through the plate. The goal of the control system is to reduce sound pressure level at a specified area on the other side of the plate. To guarantee successful operation of the control system in face of plate temperature variation, a gain-scheduling scheme is proposed to support the Filteredreference LMS algorithm.
Źródło:
Archives of Acoustics; 2011, 36, 1; 65-76
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies