Tytuł:
The simulation analysis of the bridge rectifier continuous operation in AC circuit
Autorzy:
Wciślik, M.
Strząbała, P.
Powiązania:
https://bibliotekanauki.pl/articles/97283.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
nonlinear load
bridge rectifier
modelling
active and reactive power
Opis:
The paper deals with a nonlinear model of the full–wave bridge rectifier in AC circuit with RC load for non–rigid supply system. The mathematical model of the AC circuit for this load was worked out using dimensionless variables. The model of the circuit was created and analyzed with MATLAB/Simulink. Analysis of harmonic distortions of the currents and voltages in considered circuit was carried out. Indices of power quality are described. The current–voltage characteristics for different values of capacitive load are presented. The balances active and reactive powers in the circuit were performed.
Źródło:
Computer Applications in Electrical Engineering; 2016, 14; 53-65
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analysis of power control schemes in dfig for wind energy generation
Analiza porównawcza metod stosowanych do regulacji mocy czynnej i biernej w dwustronnie zasilanym generatorze indukcyjnym
Autorzy:
Jedut, L.
Rosołowski, E.
Powiązania:
https://bibliotekanauki.pl/articles/410545.pdf
Data publikacji:
2011
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
wind generation
doubly-fed induction generator
active and reactive power control
stator flux reference frame
Opis:
This paper describes two algorithms applied for active and reactive power control in wind turbine driven doubly fed induction generator (DFIG). The first proposed method applies the PI controllers for regulation of DFIG power and the rotor current while the second one utilizes a difference approximation of a given flux derivative. Both algorithms are based on the model description with reference to the stator flux linkage frame. General description of the analyzed methods is delivered and some results of simulations are included.
W artykule przedstawiona jest analiza dwóch algorytmów stosowanych do regulacji mocy czynnej i biernej w elektrowniach wiatrowych z dwustronnie zasilanymi generatorami indukcyjnymi. W pierwszej rozważanej metodzie stosowane są regulatory PI do kontroli mocy i prądu wirnika, podczas gdy w drugiej - całkowanie ciągłe jest aproksymowane za pomocą zależności przyrostowych. W obu algorytmach model maszyny jest zapisany względem układu współrzędnych związanych ze strumieniem stojana. Zamieszczony jest opis rozważanych modeli oraz wyniki przeprowadzonych symulacyjnych testów.
Źródło:
Present Problems of Power System Control; 2011, 1; 75-88
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ sprzętu komputerowego w stanie obciążenia na generowanie wyższych harmonicznych prądu i mocy biernej pojemnościowej
Influence of computer equipment in the load state for generating harmonic current and capacitive reactive power
Autorzy:
Ludwinek, K.
Powiązania:
https://bibliotekanauki.pl/articles/267067.pdf
Data publikacji:
2016
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
wyższe harmoniczne
moc czynna i bierna
sprzęt komputerowy
UPS
higher harmonics
active and reactive power
computer equipment
Opis:
W artykule przedstawiono badania eksperymentalne wpływu zestawu komputerowego oraz UPS-a, pracujących w stanie ustalonym obciążenia, na generowanie wyższych harmonicznych prądu oraz poboru mocy biernej indukcyjnej lub pojemnościowej. Obliczenia mocy czynnej i biernej (wynikającej z przesunięcia fazowego napięcia i prądu) oraz zawartości wyższych harmonicznych w prądach pobieranych z sieci zasilania dokonano na podstawie zarejestrowanych przebiegów napięć i prądów jednostki stacjonarnej PC, monitora i drukarki laserowej oraz UPS-a, pracujących bez układu korekcji współczynnika mocy.
The article presents experimental investigations of the influence of an computer equipment and UPS operating in the steady state on generating harmonic current and the inductive or capacitive power consumption. On the basis of the recorded voltage and current waveforms, active and reactive power (resulting from the phase shift between voltage and current) and the content of higher harmonics are calculated for PC unit, monitor, laser printer and UPS, without Power Factor Correction system.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2016, 50; 53-56
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Symulacja pracy przesuwnika fazowego w sieci elektroenergetycznej przy połączeniu transformatora szeregowego w gwiazdę
A computer simulation of the phase shifter effects in the power system with wye connection of the series transformer
Autorzy:
Sarnicki, M.
Tarakan, B.
Zajczyk, R.
Powiązania:
https://bibliotekanauki.pl/articles/268014.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
przesuwnik fazowy
regulacja przepływu mocy czynnej i biernej
regulacja kąta mocy
Phase Shifter
active and reactive power flow control
power angle
Opis:
Poniższy artykuł prezentuje sposób regulacji mocy czynnej i biernej za pomocą przesuwnika fazowego, którego uzwojenie transformatora dodawczego (szeregowego) jest połączone w gwiazdę. W artykule pokazano regulację mocy czynnej i biernej na przykładzie wybranego systemu elektroenergetycznego. Omawiany przesuwnik fazowy reguluje jednocześnie przepływem mocy czynnej i biernej w danym systemie elektroenergetycznym.
The following article describes the adjustment of the active and reactive power using the phase shifter. The winding of the booster transformer (series) is wye connected. The article shows the regulation of the active and reactive power for selected power system that is 10 bus system with phase shifter. The phase shifter also regulates flow of the active and reactive power simultaneously in the power system. The most common situation is when the both power regulation are independent and it is a better way to have control of both of them. The simultaneous regulation of the active and reactive power is possible by adding transformed voltage from different phases.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 47; 167-169
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of Voltage-regulating and Phaseshifting Transformers to Control Power Flows in the Power System
Wykorzystanie transformatorów z regulacją skośną do sterowania przepływami mocy w systemie elektroenergetycznym
Autorzy:
Przygrodzki, M.
Rzepka, P.
Szablicki, M.
Powiązania:
https://bibliotekanauki.pl/articles/397531.pdf
Data publikacji:
2015
Wydawca:
ENERGA
Tematy:
rozpływ mocy
zespół transformatorowy
regulacja wzdłużno-poprzeczna
active and reactive power flow
regulating transformer
voltage-magnitude-regulating
phase-angle-regulating
Opis:
Transmission system performance results from, among other factors, the use of devices for electricity transmission and transformation. Proper operation and control of these devices allows maintaining proper electricity parameters and the continuous supply to end consumers. In the group of electricity transforming devices transformers can be distinguished by the ability to control both the magnitude and phase angle of voltage. In this way transmission system state parameters are adjusted, which enable selecting the reactive and active power. On the one hand, these are devices of a complex structure, resulting in difficult operating conditions, while on the other hand they provide a potential opportunity to influence the power flow (including active power) in power grids. This article presents the idea of voltage and phase regulation and a transformer regulating unit model. Using the transformer unit’s grid model power analyses were conducted with a focus on evaluating load flow control capabilities. The results of the calculations for the selected transformer unit are presented.active power) in power grids. This article presents the idea of voltage and phase regulation and a transformer regulating unit model. Using the transformer unit’s grid model power analyses were conducted with a focus on evaluating load flow control capabilities. The results of the calculations for the selected transformer unit are presented.
Funkcjonowanie systemu przesyłowego jest wynikiem wykorzystywania pracy m.in. urządzeń służących do przesyłu, jak i transformacji energii elektrycznej. Prawidłowa eksploatacja i sterowanie tymi urządzeniami pozwala na zachowanie właściwych parametrów energii elektrycznej oraz ciągłości zasilania odbiorców końcowych. W grupie urządzeń pozwalających na transformację energii elektrycznej można wyróżnić transformatory z regulacją, które mają możliwość kształtowania zarówno poziomu, jak i kąta napięcia. W ten sposób regulowane są parametry stanu układów przesyłowych pozwalające na dobór przesyłanych wielkości mocy biernej oraz czynnej. Z jednej strony układy te są urządzeniami o skomplikowanej budowie, co wpływa na utrudnione warunki ich eksploatacji, ale jednocześnie z drugiej strony dają one potencjalnie możliwość wpływu na rozpływy mocy (w tym mocy czynnej) w sieciach elektroenergetycznych. W artykule przedstawiono ideę regulacji wzdłużno-porzecznej oraz model zespołu transformatorowego. Wykorzystując model sieciowy zespołu transformatorowego, przeprowadzono analizy sieciowe skupione na ocenie możliwości sterowania rozpływem mocy. Dla wybranego zespołu transformatorowego przedstawiono wyniki wykonanych obliczeń.
Źródło:
Acta Energetica; 2015, 4; 87-98
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of three approaches to the security constrained unit commitment problem
Porównanie wariantów modeli doboru jednostek i ekonomicznego rozdziału obciążeń
Autorzy:
Drabecki, Mariusz
Toczyłowski, Eugeniusz
Powiązania:
https://bibliotekanauki.pl/articles/266349.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
security constrained unit commitment
economic dispatch
optimal power flow
active and reactive power
dobór jednostek
ekonomiczny rozdział obciążeń
optymalny rozpływ mocy czynnej
optymalny rozpływ mocy biernej
Opis:
A two phase approach to obtain feasibility of the Security Constrained Unit Commitment schedules is analysed. In the first planning phase a computationally tractable variant of the security constrained UC problem is considered with a simplified representation of the network flows. Three computationally tractable variants of the UC problem formulations are investigated: (i) UC_NN model without network flow constraints, (ii) UC_NC model with network constraints reflected by enforcing nodal constraints at the bus level, and (iii) UC_DC model by enforcing network constraints on active power flows. These models are tested and compared with respect to efficiency, computational burden and complexity of the corrective actions performed by TSO in the operational phase to meet security and technical requirements of the system.
W pracy jest analizowane podejście dwufazowe do problemu doboru jednostek i ekonomicznego rozdziału obciążeń w systemie elektroenergetycznym. W pierwszej fazie planistycznej jest rozważany uproszczony wariant problemu doboru jednostek i ekonomicznego rozdziału obciążeń z uproszczonym modelem ograniczeń sieciowych rozpływu mocy. Badane są trzy realistyczne obliczeniowo warianty modelu doboru jednostek i ekonomicznego rozdziału obciążeń: (i) model UC_NN bez ograniczeń sieciowych, (ii) restrykcyjny model UC_NC z ograniczeniami sieciowymi w postaci ograniczeń przepływu na poziomie szyn i łączy, and (iii) model UC_DC uwzględniający model rozpływu mocy czynnej w sieci. Modele te są testowane symulacyjnie i porównywane pod względem obliczeniowym, efektywnościowym oraz złożoności i jakości akcji dostosowawczych Operatora Sieci Przesyłowej w drugiej fazie operacyjnych działań pozwalających na uzyskanie stanów sieci spełniających wymagania bezpieczeństwa i ograniczenia techniczne.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 62; 67-70
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ opóźnienia wnoszonego przez szeregowy odczyt kanałów przetwornika A/C sterowników PLC na dokładność obliczeń mocy czynnej i biernej
Effect of delay time imparted by the serial channels of A/D converter of PLC controllers for precision computation of active and reactive power
Autorzy:
Ludwinek, K.
Makarski, P.
Cienciała, K.
Powiązania:
https://bibliotekanauki.pl/articles/269066.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
przetwornik A/C
czas przetwarzania
czas opóźnienia
sterownik PLC
moc czynna i bierna
A/D converter
delay time
PLC controller
active and reactive power
Opis:
W artykule przedstawiono wpływ opóźnienia spowodowanego pracą multiplexera wejściowego przetwornika A/C na dokładność pomiaru mocy czynnej i biernej. Analizę błędów pomiaru mocy czynnej i biernej (wynikającej z przesunięcia fazowego składowych podstawowych napięcia i prądu) przeprowadzono dla prądu i napięcia jednej fazy podczas zasilania silnika indukcyjnego klatkowego w stanie biegu jałowego. Badania eksperymentalne przeprowadzono dla sumarycznego czasu opóźnienia zmieniającego się od 0,35 s do 2 ms.
The influence of the delay time resulting from the serial multiplexed measurement of the A/D converter on the accuracy of the active and reactive power calculations is presented in this paper. Calculations of the active and reactive power (resulting from the phase shift of the fundamental voltages and currents) are conducted for one phase current and voltage during the supply of the cage induction motor in a no load state. Experimental investigations are conducted for the total delay time varying from 0.35 s to 2 ms of the phase current with relation to a phase voltage.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 56; 51-56
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies