Tytuł:
Comparison between GPC and adaptive GPC based on Takagi Sugeno multi-model for an Activated Sludge Reactor
Autorzy:
Matoug, L.
Khadir, M. T.
Powiązania:
https://bibliotekanauki.pl/articles/206049.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Instytut Badań Systemowych PAN
Tematy:
adaptive generalized predictive control
generalized predictive control
Takagi Sugeno
activated sludge reactor
activated sludge model
Opis:
This paper investigates the use of Adaptive Generalized Predictive Control (TS-AGPC) for an activated sludge reactor, based on a Takagi Sugeno (TS) model, and presents the comparison between the latter and Generalized Predictive Control using an overall TS model (TS-GPC). The reduced bio-reactor Activated Sludge ASM1 Model, which describes the biological degradation of an activated sludge reactor, is designed based on several simplifications, as a TS model, its structure being based on a set of linear submodels, covering the process input-output space, interpolated by a nonlinear weighting function µ. The adaptive GPC approach is obtained by switching between linear submodels of the TS formulation. This is performed by selecting, in turns, a portion of the weighting function µ. The winning model will then act as an internal model for the TS-AGPC control law formulation, whereas the complete TS model is used in the calculation of the TS-GPC control law. Finally, the performance under input and parametric disturbances as well as control variable constraints of the TS-AGPC controller are compared to those for a global TS-GPC controller and a benchmark PID in terms of error and response dynamics.
Źródło:
Control and Cybernetics; 2017, 46, 2; 147-176
0324-8569
Pojawia się w:
Control and Cybernetics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Określenie parametrów biokinetycznego modelu osadu czynnego ASDM dla oczyszczalni ścieków pracującej w technologii sekwencyjno–przepływowej
Determination of activated sludge model ASDM parameters for waste water treatment plant operating in the sequential–flow technology
Autorzy:
Zdebik, D.
Powiązania:
https://bibliotekanauki.pl/articles/401522.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
biokinetyczny model osadu czynnego
kalibracja
parametry kinetyczne modelu
activated sludge model
calibration
kinetic parameters of the model
Opis:
W artykule przedstawiono sposób wykonania kalibracji biokinetycznego modelu osadu czynnego przy użyciu programu komputerowego BioWin. Schemat komputerowy został opracowany na podstawie oczyszczalni ścieków pracującej w technologii sekwencyjno – przepływowej. Do kalibracji biokinetycznego modelu osadu czynnego wykorzystano wyniki badań ścieków dopływających i oczyszczonych pochodzących z istniejącego obiektu. Wynikiem przeprowadzonych analiz były zmiany w biokinetycznym modelu w zakresie parametrów kinetycznych oraz pracy urządzeń oczyszczalni. Przedstawiony sposób badania wpływu wybranych parametrów biokinetycznego modelu osadu czynnego (m.in. maksymalna szybkość wzrostu autotrofów, udział zawiesiny organicznej w zawiesinie ogólnej, skuteczność pracy osadników wtórnych) może być wykorzystany podczas prowadzenia badań symulacyjnych innych oczyszczalni ścieków.
This paper presents a method for calibration of activated sludge model with the use of computer program BioWin. Computer scheme has been developed on the basis of waste water treatment plant operating in the sequential – flow technology. For calibration of the activated sludge model data of influent and treated effluent from the existing object were used. As a result of conducted analysis was a change in biokinetic model and kinetic parameters parameters of wastewater treatment facilities. The presented method of study of the selected parameters impact on the activated sludge biokinetic model (including autotrophs maximum growth rate, the share of organic slurry in suspension general operational, efficiency secondary settling tanks) can be used for conducting simulation studies of other treatment plants.
Źródło:
Inżynieria Ekologiczna; 2015, 41; 79-89
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Calibration of Activated Sludge Model with Scarce Data Sets
Autorzy:
Andraka, D.
Piszczatowska, I. K.
Dawidowicz, J.
Kruszyński, W.
Powiązania:
https://bibliotekanauki.pl/articles/124360.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
activated sludge models
modelling and simulation
model calibration
Opis:
Mathematical models of activated sludge process are well recognised and widely implemented by researchers since 1980's. There is also numerous software available for modelling and simulation of activated sludge plants, but practical application of those tools is rather limited. One of the main reasons for such a situation is a difficult process of model calibration the requires extended data sets collected at investigated plant. Those data are usually not included in a standard plant monitoring plan. In the paper the problem of model calibration with the data sets derived from standard monitoring plan is discussed with a special regard to simulation objectives and data availability. The research was conducted with operational data from Białystok Wastewater Treatment Plant. The model of the plant was based on Activated Sludge Model No.3 developed by IWA Task Group and implemented in ASIM simulator. Calibration and validation of the model gave promising results, but further applications should be carefully considered, mainly due to uncertainties underlying input data.
Źródło:
Journal of Ecological Engineering; 2018, 19, 6; 182-190
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamic simulation for wastewater treatment plants management: Case of Souk-Ahras region, north-eastern Algeria
Dynamiczna symulacja zarządzania oczyszczalniami ścieków: przykład regionu Souk-Ahras w północno-wschodniej Algierii
Autorzy:
Sabri, D.
Yassine, D.
Yahia, H.
Dounia, M.
Powiązania:
https://bibliotekanauki.pl/articles/292322.pdf
Data publikacji:
2017
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
activated sludge
Algeria
ASM1
simulation
wastewater
Algieria
model ASM1
osad czynny
symulacja
ścieki
Opis:
Treatment performances of two wastewater treatment plants (WWTPs), located in North-Eastern Algeria (Souk-Ahras and Sedrata) were tested using ASM1 model. The model, to be considered as a decision tool for the appropriate management of activated sludge systems, served for the prediction of both WWTP behaviours under different operating conditions. In Sedrata WWTP the first management scenarios is based on an increase of inflow rate, taking into account a new transfer volume from a nearby zone. In a second scenerio, the ultimate flow of 40 000 m3∙d–1 is estimated. Regarding Souk-Ahras WWTP, three scenarios were tested. The first tested the impact of an increase of the extraction flow rate and yielded a reduction by 37% of sludge production. The second dealt with the management of the mass budget of substrata and biomass. Finally, the third application was devoted to the estimation of the plant ultimate capacity, estimated to be 60 000 m3∙d–1.
Stosując model ASM1, testowano działanie dwóch oczyszczalni ścieków zlokalizowanych w północnowschodniej Algierii w miejscowościach Souk-Ahras i Sedrata. Model, traktowany jako narzędzie w podejmowaniu decyzji co do właściwego zarządzania systemem osadu czynnego, służył przewidywaniu zachowania się obu oczyszczalni w różnych warunkach operacyjnych. W oczyszczalni Sedrata w pierwszym scenariuszu zarządzania założono zwiększoną prędkość przepływu uwzględniającą dodatkową objętość ścieków dostarczaną z pobliskiej strefy. W drugim oszacowano końcową przepustowość równą 40 000 m3∙d–1. W odniesieniu do oczyszczalni w Souk-Ahras testowano trzy scenariusze. W pierwszym rozpatrywano wpływ zwiększonej prędkości przepływu, w efekcie uzyskano 37-procentowe zmniejszenie produkcji osadu. Drugi scenariusz dotyczył zarządzania bilansem masy podłoża i biomasy. Trzeci z kolej polegał na ocenie docelowej przepustowości ścieków szacowanej na 60 000 m3∙d–1.
Źródło:
Journal of Water and Land Development; 2017, 34; 221-231
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies