Wyświetlanie 1-3 z 3
Tytuł:
Comparison of conventional and crosslinked ultra high molecular weight polyethylene (UHMWPE) used in hip implant
Autorzy:
Laska, Anna
Powiązania:
https://bibliotekanauki.pl/articles/1178415.pdf
Data publikacji:
2017
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Differential Scanning Calorimetry
acetabular cup
conventional UHMWPE
crosslinked UHMWPE
structural parameters
Opis:
Since the 1960s UHMWPE has been the material of choice for bearing surfaces in total hip replacements. In spite of its clinical success over years, a large number of necessary revisions has been recently reported. The clinical life span of the hip prostheses is limited by weardebris-induced osteolysis and aseptic loosening. The problem is very complex because of the variety of factors affecting UHMWPE. Nowadays, scientists are working on how optimally adjust the material properties and the implant design in order to increase wear resistance and retain other mechanical properties. The aim of the study is to investigate structural parameters of two UHMWPE material states – conventional (non-crosslinked) and crosslinked. Those types of UHMWPE show slightly different properties, which can affect further behaviour in human body. The comparison between conventional and crosslinked UHMWPE is presented. Differential Scanning Calorimetry (DSC) is the analysis method applied in the research. The structural parameters of UHMWPE are correlated with its mechanical and tribological properties.
Źródło:
World Scientific News; 2017, 73; 51-60
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental analysis of insertion torques and forces of threaded and press-fit acetabular cups by means of ex vivo and in vivo measurements
Autorzy:
Vogel, D.
Rathay, A.
Teufel, S.
Ellenrieder, M.
Zietz, C.
Sander, M.
Bader, R.
Powiązania:
https://bibliotekanauki.pl/articles/307285.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
panewka
gwintowanie
kość
kość syntetyczna
insertion force
insertion torque
acetabular cup
press-fit
threaded
synthetic bone
Opis:
In THA sufficient primary implant stability is the precondition for successful secondary stability. Industrial foams of different densities have been used for primary stability investigations. The aim of this study was to analyse and compare the insertion behaviour of threaded and press-fit cups in vivo and ex vivo using bone substitutes with various densities. Methods: Two threaded (Bicon Plus®, Trident® TC) and one press-fit cup (Trident PSL®) were inserted by orthopaedic surgeons (S1, S2) into 10, 20 and 31 pcf blocks using modified surgical instruments allowing measurements of the insertion forces and torques. Furthermore, the insertion behaviour of two cups were analysed intraoperatively. Results:Torques for the threaded cups increased while bone substitute density increased. Maximum insertion torques were observed for S2 with 102 Nm for the Bicon Plus® in 20 pcf blocks and 77 Nm for the Trident® TC in 31 pcf blocks which compares to the in vivo measurement (85 Nm). The average insertion forces for the press-fit cup varied from 5.2-6.8 kN (S1) and 7.2-11.5 kN (S2) ex vivo. Intraoperatively an average insertion force of 8.0 kN was determined. Conclusions: Implantation behaviour was influenced by acetabular cup design, bone substitute and experience of the surgeon. No specific density of bone substitute could be favoured for ex vivo investigations on the implantation behaviour of acetabular cups. The synthetic bone blocks of high density (31 pcf) led to problems regarding cup orientation and seating. Therefore, bone substitutes used should be critically scrutinized in terms of the comparability to the in vivo situation.
Źródło:
Acta of Bioengineering and Biomechanics; 2017, 19, 3; 155-163
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybrane parametry procesu tarcia powłoki ochronnej formowanej metodą IBAD na powierzchni polietylenowej panewki biodrowej
Selected parameters of friction process for protective IBAD coating on hip endoprosthesis polyethylene cup
Autorzy:
Rybak, T.
Sulej-Chojnacka, J.
Mróz, A.
Gierzyńska-Dolina, M.
Rajchel, B.
Powiązania:
https://bibliotekanauki.pl/articles/211980.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Obróbki Plastycznej
Tematy:
endoproteza stawu biodrowego
para-tnąca panewka
powłoki C-C
metody jonowe
badania tarciowo-zużyciowe
hip endoprotesis
femoral head-acetabular cup friction couple
C-C coating
ion methods
friction-wear tests
Opis:
W artykule przedstawiono wyniki badań tribologicznych pary trącej „głowa-panewka”, stanowiącej układ ruchowy endoprotezy stawu biodrowego, o średnicy ?28 mm. W badaniach uSyto głowę wykonaną ze stopu CoCrMo oraz panewkę UHMWPE z powłoką C-C wykonaną w Instytucie Fizyki Jądrowej PAN w Krakowie. Badania prowadzono w Laboratorium Inżynierii Powierzchni i Tribologii Instytutu Obróbki Plastycznej w Poznaniu z wykorzystaniem symulatora SBT-01. Przeprowadzono badania momentu tarcia, siły docisku, wartości temperatury styku oraz zużycia elementów endoprotezy o średnicy 28 mm i porównano z wynikami pary trącej: głowa CoCrMo oraz panewka UHMWPE bez powłoki uformowanej jonowo. Podano i omówiono wyniki badań.
The article presents results of tribological tests for 28 mm head-cup friction couple, which is the motion system of the hip endoprosthesis. In the studies femoral head made of CoCrMo alloy and polyethylene acetabular cup with C-C coating made in Institute of Nuclear Physics of Polish Academy of Science were applied. Investigations were performed in Laboratory of Surface Engineering and Tribology in Metal Forming Institute in Poznan using SBT-01 simulator. Friction moment, contact force, joint temperature and o 28 mm friction elements wear were investigated. This results was compared to results of friction couple: CoCrMo femoral head and UHMWPE acetabular cup without ion formed coating. There are presented and discussed investigations results.
Źródło:
Obróbka Plastyczna Metali; 2011, 22, 4; 291-301
0867-2628
Pojawia się w:
Obróbka Plastyczna Metali
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies