Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "accuracy of measurements" wg kryterium: Temat


Tytuł:
Usefulness assessment of standard measuring instruments installed on sea-going ships to perform energy measurements
Autorzy:
Górski, Z.
Cwilewicz, R.
Powiązania:
https://bibliotekanauki.pl/articles/260338.pdf
Data publikacji:
2007
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
standard measurement instrumentation
ships
accuracy of measurements
Opis:
The presented work is a contribution to discussion on usefulness of application of measurement instrumentation used on sea-going ships for energy measurement and scientific research purposes. Contemporary sea-going ships are equipped as a rule with up-to-date measurement instrumentation usually based on electronic data processing and computer technique. These authors have made many times use of such instruments in their research work. This way it was not necessary to install any special instruments, that significantly reduced measurement cost. In such cases to obtain a sufficient accuracy of measurements constitutes a crucial problem. In this paper was presented an analysis of measurement errors of some operational parameters of ship and its main propulsion system, elaborated within the frame of the KBN research project no. 9 T12D 033 17. Results of the analysis confirm usefulness of the standard measurement instrumentation installed on ships, and its sufficient accuracy.
Źródło:
Polish Maritime Research; 2007, 1; 23-27
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The attempt to use levelling rods for testing metric properties of surveying instruments, which are used for reflectorless distance measurements
Autorzy:
Świerczyńska, E.
Kołakowska, M.
Powiązania:
https://bibliotekanauki.pl/articles/106769.pdf
Data publikacji:
2014
Wydawca:
Politechnika Warszawska. Wydział Geodezji i Kartografii
Tematy:
terrestrial laser scanning
reflectorless measurements
accuracy of measurements
skanowanie laserowe naziemne
pomiary bezlustrowe
dokładność pomiarów
Opis:
This paper presents results of two experimental cycles of measurements performed with the use of the terrestrial laser scanner Z+F IMAGER 5006h and the reflectorless tacheometer Leica TPS 1202. These tests aimed at determination of metric properties of surveying instruments, which are used for reflectorless distance measurements and which are often applied to project the geometry of objects. In the course of research works issues influencing the reflection of a laser beam by the measured surface, as well as their influence on the data quality. In order to analyse metric properties of applied instruments, levelling rods were used as test fields of geometrically specified division. It was stated basing on the performed analyses, that the influence of the incidental angle of a laser beam on the accuracy of reflectorless measurements is included within the limits of the error of distance measurements of a given instrument. However, the uniform trend of increasing differences between measured values and the nominal value may be noticed, together with the increase of the incidental angle of the axis of collimation on the measured surface of the test field.
Źródło:
Reports on Geodesy and Geoinformatics; 2014, 96; 38-54
2391-8365
2391-8152
Pojawia się w:
Reports on Geodesy and Geoinformatics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prawna kontrola metrologiczna wag nieautomatycznych elektronicznych
The legal metrological control of non-automatic electronic scales
Autorzy:
Wąsowicz, Zdzisław
Antosiuk, Marek
Dębowski, Marek E.
Powiązania:
https://bibliotekanauki.pl/articles/952567.pdf
Data publikacji:
2016
Wydawca:
Główny Urząd Miar
Tematy:
wagi elektroniczne
dokładność pomiarów
kontrola metrologiczna
legalizacja ponowna
electronic scales
accuracy of measurements
metrological control
reverification
Opis:
W artykule przedstawiono zagadnienie prawnej kontroli metrologicznej wag nieautomatycznych elektronicznych wprowadzonych do użytkowania na podstawie decyzji zatwierdzenia typu oraz w wyniku dokonania oceny zgodności. Opisano zasadę działania wag nieautomatycznych elektronicznych oraz ich rodzaje. Dodatkowo przedstawiono wymagania jakie, stawiane są wagom nieautomatycznym elektronicznym oraz opisano proces legalizacji ponownej.
The paper presents the issue of legal metrological control of non-automatic electronic scales brought into use based on type approval decision and as a result of assessment of conformity. It describes how non-automatic electronic scales and their types work. In addition, presents the requirements that are placed on the non-automatic electronic scales and describes the process of re-verification.
Źródło:
Metrologia i Probiernictwo : biuletyn Głównego Urzędu Miar; 2016, 3-4 (14-15); 53-58
2300-8806
Pojawia się w:
Metrologia i Probiernictwo : biuletyn Głównego Urzędu Miar
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Use of Matlab Package for External Local Calibration of IR Camera with Microbolometric FPA Detector
Autorzy:
Kruczek, T.
Adamczyk, W.
Kruczek, G.
Powiązania:
https://bibliotekanauki.pl/articles/114419.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
thermovision infrared measurements
improvement of accuracy of infrared camera measurements
Opis:
This work presents the method of improving the accuracy of temperature measurement results obtained by means of long-wave infrared camera equipped with focal plane array (FPA) detector. The typical accuracy of infrared cameras specified by their manufacturers amounts to ±2 K or ±2% of the measured value of temperature. Very often a better accuracy of the measurements is required, e.g. during the measurements of human body temperature. To improve the measurement accuracy an external local (in terms of temperature range) correction of obtained results on the basis of comparison measurement results of black body temperature and next with use of MATLAB package has been proposed.
Źródło:
Measurement Automation Monitoring; 2016, 62, 10; 337-340
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dokładność tomografów przemysłowych CT w wyznaczaniu wymiarów geometrycznych
The accuracy of industrial computer tomography scanners in determining geometric dimensions
Autorzy:
Kowaluk, T.
Ratajczyk, E.
Powiązania:
https://bibliotekanauki.pl/articles/152447.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
tomografia komputerowa CT
wzorce geometryczne
dokładność pomiarów
model CAD
computer tomography
geometric gauges
accuracy of measurements
CAD model
Opis:
Zaprezentowano metodę w zakresie wyznaczania dokładności wymiarów geometrycznych przemysłowych tomografów komputerowych zgodnie z wytycznymi VDI/VDE 2630. Zaprezentowano propozycje sprawdzenia dokładności tomografu opartą na wzorcu składającym się z zestawu trzpieni z końcówkami kulistymi. Opisano wzorzec zaprojektowany i skonstruowany w Instytucie Metrologii i Inżynierii Biomedycznej Politechniki Warszawskiej. Wzorzec został wykalibrowany za pomocą współrzędnościowej maszyny pomiarowej ACCURA firmy C. Zeiss. Na podstawie uzyskanych danych pomiarowych wykonany został model CAD wzorca. Uzyskane podczas pomiarów tomograficznych chmury punktów zostały porównane z modelem CAD. Przeprowadzono analizę statystyczną uzyskanych wyników oraz sprawdzono podawaną przez producenta dokładność pomiarów geometrycznych tomografu komputerowego METROTOM 800.
This paper presents the construction of a computer tomography scanner (CT). It discusses the principles of operation of CT. The parameters characterizing the accuracy are described. The proposed method for determining the geometric dimension accuracy of industrial computer tomography scanners according to VDI / VDE 2630 is discussed. The presented proposals can be used to verify the tomography scanner accuracy based on gauges consisting of a set of spherical stylus. A gauge to check the CT accuracy was designed and constructed at the Institute of Metrology and Biomedical Engineering, the Warsaw University of Technology. The gauge was calibrated using a coordinate measuring machine ACCURA 7 by C. Zeiss. Based on the measurement data a CAD model of the gauge was made. The measurement strategies were based on the CAD model. The point clouds for tomographic measurements were compared with the CAD model. The results of the two measuring devices were compared. Statistical analysis of the results was conducted. It showed statistically significant differences between the methods of measuring on the confidence level of 95%. It was also confirmed by the statistical parameters obtained for the both methods. The values of the range and standard deviations were approximately twice as high for the tomographic measurements. Also the accuracy specified by the manufacturer of CT METROTOM 800 was verified.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 5, 5; 462-465
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Results of Non-Contact Coordinate Measurement of a Cutting Tool Applied for Mould Machining
Autorzy:
Bazan, Anna
Magdziak, Marek
Jamuła, Barbara
Powiązania:
https://bibliotekanauki.pl/articles/11236770.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
cutting tools
tool wear monitoring
mould machining
measuring technique
non-contact measurements
accuracy of measurements
narzędzia skrawające
zużycie narzędzi
obróbka form
technika pomiarowa
pomiar bezkontaktowy
dokładność pomiaru
Opis:
One of the main problems of machining of moulds is the need for an effective monitoring system of wear of cutting tools. This paper presents the results of coordinate measurements of a cutting tool which were obtained by using the non-contact measuring system based on the ACCURA II coordinate measuring machine equipped with the LineScan laser measuring probe and the Calypso metrology software. Investigations were carried out for several measurement strategies including different measurement resolutions and scanning speeds. The results of the coordinate measurements obtained by using the above-mentioned coordinate measuring system were compared to the reference data measured by means of the InfiniteFocus microscope. The measurement results were analysed by means of two software packages: Focus Inspection and Zeiss Reverse Engineering. The point clouds measured by using the LineScan probe were characterized by the selected deviation statistics equal to 4-6 μm when a good match between measurement points and the reference data was obtained. Moreover, these statistics mainly depend on the measurement resolution. The results of the performed experimental research allowed for drawing conclusions concerning the significance of the effect of the adopted measurement strategies on the results of the non-contact coordinate measurements of the selected cutting tool. The application of the non-contact coordinate measurements to the above-mentioned measurement task may contribute to the development of regeneration methods for cutting tools applied for mould manufacturing.
Źródło:
Archives of Foundry Engineering; 2022, 22, 4; 121--127
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiar wilgotności drewna wilgotnościomierzami pojemnościowymi
Wood moisture content measurements using capacitance based moisture meters
Autorzy:
Tannenberg, K.
Tannenberg, G.
Powiązania:
https://bibliotekanauki.pl/articles/151451.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
dokładność pomiaru wilgotności drewna
wilgotnościomierz pojemnościowy
rozkład wilgotności
accuracy of wood moisture content measurements
capacitance based moisture meters
cross-section moisture distribution
Opis:
W artykule omówiono zasadę działania pojemnościowych wilgotnościomierzy do drewna. Przedyskutowano główne źródła niepewności pomiaru. Doświadczalnie określono wpływ rozkładu wilgotności wzdłuż przekroju próbki na niepewność pomiaru. Podano analityczną zależność wielkości tej niepewności dla wilgotnościomierzy pojemnościowych i rezystancyjnych. Potwierdzono lepszą dokładność wilgotnościomierzy rezystancyjnych również w przypadkach niejednorodnego rozkładu wilgotności wzdłuż przekroju próbki.
The paper starts with presentation of the basic principles of operation of capacitance-based wood moisture meters (Sections 1, 2, Figs. 1-5) followed by discussion of the main sources of moisture content measurement errors i.e. wood temperature (Section 5), sample timber thickness (Section 6), wood density (Section 7) and moisture distribution along the sample cross-section (Section 8). Next, there is described an experiment conducted to determine the influence of the cross-section moisture distribution on the measurement error (Sections 9, 10). The moisture distribution was measured using an atmospherically insulated sample of wood and a resistance-based moisture meter with insulated needles inserted into the sample on various depths. Simultaneously the measurements were taken by means of a capacitance-based moisture meter. The tests took 28 days. The results are given in Tables 1 and 2. The moisture distribution along the cross-section on subsequent days is shown in Fig. 8. Analytical dependences describing the measurement error as a function of the maximal difference of moisture content along the cross-section were determined. These dependences are given for capacitance and resistance-based moisture meters (Figs. 9, 10). The research confirmed the higher accuracy of resistance-based moisture meters also in cases of heterogeneous distribution of the moisture content.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 2, 2; 161-164
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
New approach to the accuracy description of unbalanced bridge circuits with the example of pt sensor resistance bridges
Autorzy:
Warsza, Z. L.
Powiązania:
https://bibliotekanauki.pl/articles/385278.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
resistance bridge
sensor
measures of accuracy
error
uncertainty of measurements
Opis:
After short introduction transfer coefficients of the unloaded four arms bridge of arbitrary variable arm resistances, supplied by current or voltage source, are given in Table 1. Their error propagation formulas are find and two rationalized forms of accuracy measures, i.e. related to the initial bridge sensitivities and of double component form as sum of zero error and increment error of the bridge transfer coefficients are introduced. Both forms of transfer coefficient measures of commonly used bridge - of similar initial arm resistances in balance and different variants of their jointed increments, are given in Table 3. As the example limited errors of some resistance bridges with platinum Pt100 industrial sensors of class A and B are calculated Table 4 and analyzed. Presented approach is discussed and found as the universal solution for all bridges and also for any other circuits used for parametric sensors.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2010, 4, 2; 8-15
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Algorithms for improving the position determination of an UAV equipped with a single-frequency GPS receiver for low-altitude photogrammetry
Autorzy:
Krasuski, Kamil
Wierzbicki, Damian
Lalak, Marta
Ciećko, Adam
Powiązania:
https://bibliotekanauki.pl/articles/27311750.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
UAV
GNSS measurements
linear elements of exterior orientation
accuracy
Opis:
The article presents the results of research on the development of a method for improving the positioning accuracy of an UAV equipped with a single-frequency GPS receiver for determining the linear elements of exterior orientation in aerial photogrammetry. Thus, the paper presents a computational strategy for improving UAV position determination using the SPP code method and the products of the IGS service. The developed algorithms were tested in two independent research experiments performed with the UAV platform on which an AsteRx-m2 UAS single-frequency receiver was installed. As a result of the experiments, it was shown that the use of IGS products in the SPP code method made it possible to improve the accuracy of the linear elements to the level of about ±2.088 m for X coordinate, ±1.547 m for Y coordinate, ±3.712 m for Z coordinate. The paper also shows the trend of changes in the obtained accuracy in determining linear elements of exterior orientation in the form of a linear regression function. Finally, the paper also applies the SBAS corrections model for the improvement of UAV position calculation and determination of linear elements of exterior orientation. In this case, the improvement in the accuracy of determining the linear elements of exterior orientation is about ±1.843 m for X coordinate, ±1.658 m for Y coordinate, ±7.930 m for Z coordinate. As the obtained test results show, the use of IGS products and SBAS corrections in the SPP code method makes it possible to improve the determination of UAV positions for the use in aerial photogrammetry.
Źródło:
Metrology and Measurement Systems; 2023, 30, 3; 441--459
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determining the Number of Measurements and Bootstrap Samples Required to Estimate of Long-Term Noise Indicators
Autorzy:
Stępień, Bartłomiej
Powiązania:
https://bibliotekanauki.pl/articles/1953547.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
bootstrap
bootstrap replications
long-term noise indicators
number of measurements
uncertainty
accuracy
Opis:
The minimum size of the bootstrap algorithm input parameters have been determined for estimation of long-term indicators of road traffic noise. Two independent simulation experiments have been performed for that purpose. The first experiment served to determine the impact of original random sample size, and the second to determine the impact of number of the bootstrap replications on the accuracy and uncertainty of estimation of long-term noise indicators. The inference has been carried out based on results of non-parametric statistical test at significance level α = 0:05. The simulation experiments have shown that estimation of long-term noise indicators with uncertainty below ±1 dB(A) requires all-day noise measurements during three randomly selected days during the year in a dense urban development. The maximum size of original random sample should not exceed n = 50 elements. The minimum number of bootstrap replications necessary for estimation should be B = 5000. The data used to the simulation experiments and carry out the analysis were results of continuous monitoring of road traffic noise recorded in 2009 in one of the main arteries of Krakow in Poland.
Źródło:
Archives of Acoustics; 2020, 45, 4; 613-623
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elektryczny kalibrator elektrod redox
Electrical calibrator of redox electrodes
Autorzy:
Suchocki, K.
Powiązania:
https://bibliotekanauki.pl/articles/152779.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiar potencjału redox
kalibracja
dokładność pomiaru
measurements of redox potential
calibration
accuracy of measurement
Opis:
Pomiar wartości potencjału redox jest wykorzystywany do oceny stanu środowiska naturalnego, dlatego bardzo istotna jest dokład-ność z jaką jest on wykonywany. Duży wpływ ma na nią między innymi kalibracja elektrod redox wraz z dołączonymi do nich urządzeniami pomiarowymi. Do chwili obecnej kalibrację elektrod redox wykonuje się przy pomocy roztworów redox, co niestety nie gwarantuje jej dużej dokładności. W celu jej poprawy opracowano koncepcję elektrycznego kalibratora redox. Urządzenie to charakteryzuje się prostą konstrukcją i pozwala na szybką i dokładną kalibrację elektrod redox napięciem bipolarnym w bardzo szerokim zakresie. W artykule omówiono budowę elektrycznego kalibratora redox, a także przeanalizowano czynniki wpływające na rozkład potencjału pola elektrycznego w jego elektrodzie kalibracyjnej. Omówiono także wpływ konstrukcji kalibratora na szybkość ustalania się rozkładu potencjału pola elektrycznego i dokładność przeprowadzanej kalibracji elektrod redox.
Measurements of the redox potential value are used in estimation of the natural environment condition, for this reason it is important to take the measurements accurately. The redox electrodes calibration together with measuring devices connected to the electrodes influ-ence the measurement accuracy significantly. Nowadays the cali-bration of the redox electrodes is performed with use of redox solutions which, unfortunately does not always provide the adequate accuracy. Therefore, an electrical redox calibrator has been devel-oped. This device has a simple construction and allows fast and accurate calibration of the redox electrodes in a broad range with use of bipolar voltage. In the paper the electrical structure of the redox calibrator is presented. The factors influencing the decomposition of the electric field potential are analysed. Additionally, the influence of the calibrator construction on the speed of the electric potential field decomposition settlement as well as the accuracy of the performed redox electrodes calibration are discussed.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 8, 8; 848-850
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Accuracy of measuring small heeling angles of a ship using an inclinometer
Autorzy:
Naus, K.
Wąż, M.
Powiązania:
https://bibliotekanauki.pl/articles/135553.pdf
Data publikacji:
2015
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
heel vessel
angle measurements
accuracy of measuring
horizon line
optical method
inclinometer
CCD camera
Opis:
This article describes studies that evaluate the accuracy of measuring a ship’s heeling angle with an inclinometer. It does so by comparing inclinometer readings with benchmark measurements made with the optical method. The first part of the article describes the measurement station used for gathering measurement data. This station included an inclinometer and a CCD camera, and was used to process digital images incorporating a horizon line to indicate the ship’s heeling angle. The second part of the article describes the data gathering process carried out on a ship at sea. The final part describes a statistical analysis which compares the angular measurements based on an inclinometer with simultaneous optical benchmark measurements.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2015, 44 (116); 25-28
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Influence Of Propagation Environment On The Accuracy Of Emission Source Bearing
Autorzy:
Ziółkowski, C.
Kelner, J. M.
Powiązania:
https://bibliotekanauki.pl/articles/220529.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
DF
methodology of bearing measurement
bearing accuracy
measurements in multipath environment
power azimuth spectrum
Opis:
This paper focuses on the radio direction finding (DF) in multipath environments. Based on the measurement results presented in the open literature, the authors analyse the influence of environment transmission properties on the spread of the signal reception angle. Parameters that define these properties are rms delay and angle spreads. For these parameters, the mutual relationship is determined. This relationship is the basis for assessment of the required number of bearings that minimize the influence of the environment on the accuracy of DF procedure. In the presented analysis, the statistical properties of the signal reception angle are approximated by the normal distribution. The number of bearings versus the rms delay spread is presented as the main objective of this paper. In addition, a methodology of the bearings’ spatial averaging that provides better estimation of the reception angle is shown.
Źródło:
Metrology and Measurement Systems; 2015, 22, 4; 591-600
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The accuracy investigation of point coordinates’ determination using a fixed basis for high-precision geodesy binding
Autorzy:
Litynskyi, Volodymyr
Litynskyi, Svyatoslav
Vivat, Anatolii
Fys, Mykhailo
Brydun, Andrii
Powiązania:
https://bibliotekanauki.pl/articles/106849.pdf
Data publikacji:
2019
Wydawca:
Politechnika Warszawska. Wydział Geodezji i Kartografii
Tematy:
optimization of linear-angular measurements
linear-angular measurements
coordinates determination
accuracy of coordinates determination
optymalizacja pomiarów liniowo-kątowych
pomiary liniowo-kątowe
określanie współrzędnych
dokładność określenia współrzędnych
Opis:
Modern scanners can perform terrestrial topographic survey with resolution of 1 cm and accuracy of 2 mm in just a few minute‘s time, from the distance of up to 100 meters. However, for surface topographical surveying of large territories or complex industrial objects, it is necessary to conduct geodetic traverses and perform their binding to the points of the geodesic basis. One method of coordinate transferring during surveying is by using the method of inverse linear-angular intersection, which involves the measuring of the respective sides S1, S2 and the β angle between them. This method is more precise than the classical one, which usually contains centring and reduction errors. The linear-angular intersection method can also be used for many applications in engineering geodesy, for laying geodetic traverses, and for binding to the wall based points of ground-surveying.
Źródło:
Reports on Geodesy and Geoinformatics; 2019, 107; 19-23
2391-8365
2391-8152
Pojawia się w:
Reports on Geodesy and Geoinformatics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estymacja niepewności w pośrednich pomiarach wieloparametrowych na przykładzie dwu układów rezystancyjnych 3D
Estimation of uncertainties in multivariable indirect measurements on the example of two resistance circuits 3D
Autorzy:
Warsza, Z. L.
Puchalski, J.
Powiązania:
https://bibliotekanauki.pl/articles/930291.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
ocena dokładności
pośrednie pomiary wielu zmiennych
propagacja bezwzględnych i względnych niepewności
macierz kowariancyjna
estimation of accuracy
indirect multivariable measurements
absolute and relative uncertainty
covariance matrixes
Opis:
W artykule rozważa się wyznaczanie niepewności wieloparametrowych pomiarów pośrednich dla trzech przykładów układów prądu stałego. Zaproponowano rozszerzenie podanej w Suplemencie 2 do GUM statystycznej metody wektorowej szacowania niepewności pomiaru zbioru pojedynczych wartości parametrów multimenzurandu na opis niepewności dla zakresów tych parametrów. Podano wzór dla macierzy kowariancji niepewności względnych wektora multimenzurandu. Przedstawiono macierze kowariancji dla niepewności pośredniego pomiaru rezystancji trzech skojarzonych ze sobą rezystorów, tj. jako ramion mostka Wheatstone’a trzykrotnie połączonych w różnej kolejności oraz bez konieczności rozłączania obwodu mostka, dzięki zastosowaniu niekonwencjonalnego obocznego sposobu jego zasilania z dwu źródeł prądu; oraz omówiono pomiar trzech wewnętrznych rezystancji obwodu o strukturze gwiazdy z jej zacisków. Podstawowy wniosek jest taki, że w opisie dokładności dla zakresów wielkości mierzonych bezpośrednio i pośrednio w pomiarach wielowymiarowych możliwe jest stosowanie wektorowego prawa propagacji, nie tylko niepewności bezwzględnych wg GUM, ale również niepublikowanych dotychczas - dla niepewności względnych.
In this paper two examples of processing uncertainties of an indirect multivariable measurements of DC resistance circuits without disconnection are considered. It was proposed to extend the vector method of estimating measurement uncertainties, given in Supplement 2 to GUM by the formula for the relative uncertainties. The covariance matrixes of uncertainties of two DC electrical measurement circuits with multiplicative and additive types of measurement equations are presented, i.e.: for indirect measurement of three resistances with using them in three variants of balanced Wheatstone bridge or without disconnection this bridge circuit but with apply unconventional current supplies; the measurement of three internal resistances of the star circuit from its terminals. Formulas for absolute and relative uncertainties and their correlation coefficients are given. The general conclusion is that for description the accuracy of multivariable measurement instrumental systems relative uncertainties are preferable then absolute ones and uncertainties of parameters of their main measurement functions should be also considered.
Źródło:
Pomiary Automatyka Robotyka; 2018, 22, 4; 31-38
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies