Wyszukujesz frazę "absorpcyjna pompa ciepła" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Application of the Alternative Energy Sources in Heating and Air-Conditioning Installations
Wykorzystanie alternatywnych źródeł energii w instalacjach grzewczo-klimatyzacyjnych
Autorzy:
Cholewa, T.
Guz, Ł.
Siuta-Olcha, A.
Powiązania:
https://bibliotekanauki.pl/articles/388097.pdf
Data publikacji:
2010
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
alternatywne źródła energii
kolektory słoneczne
absorpcyjna pompa ciepła
sprężarkowa pompa ciepła
alternative energy sources
solar collectors
absorptive heat pump
air-compressor heat pump
Opis:
One of the most important problems of last years is the development of society, which is not compatible with environment protection. Total consumption of energy does not reflect already the degree of economic development. The index of scientifical and technical progress is nowadays the minimization of the energy consumption and its ecological cleanness. Additionally growing prices of energy carriers, the environmental degradation and climate changes make alternative energy sources interesting. Alternative energy sources can be used not only for room heating but also for its cooling. The connection these both functions by means of 4 different ideas of the heating and air-conditioning installation for the existing auditorium is presented. In the first idea main devices are solar collectors, air-compressor heat pump, the underground heat magazine filled with stones and a water, and ground probes. The second solution introduces the connection into one system of solar collectors, the air-compressor heat pump, the triple hydraulical coupling and ground probes. Into the third solution entered ground probes, solar collectors, absorptive heat pump and the gas boiler. The main elements of the fourth solution are compact heating and cooling devices and solar collectors, which work with warm water tank. The technological schema with well-chosen devices are presented and the special attention on advantages and disadvantages of each solutions is paid. Besides for solution III and IV capital costs, the annual conventional fuel consumption on needs of the heatings, emissions of pollutions to the atmosphere and savings resulting from the use of alternative sources energy were calculated.
Jednym z ważniejszych problemów ostatnich lat jest pogodzenie rozwoju cywilizacyjnego społeczeństwa ze środowiskiem naturalnym. Globalne zużycie energii nie odzwierciedla już dziś stopnia rozwoju gospodarczego, a wręcz odwrotnie. Wyznacznikiem postępu naukowo-technicznego danego kraju jest obecnie minimalizacja zużycia energii i jej ekologiczna czystość. Dodatkowo ciągle rosnące ceny nośników energii, degradacja środowiska naturalnego oraz zmiany globalne klimatu doprowadziły do wzrostu zainteresowania alternatywnymi źródłami energii. Alternatywne źródła energii można wykorzystywać zarówno do ogrzewania, jak i chłodzenia pomieszczeń. Połączenie tych obu funkcji zaprezentowano za pomocą 4 różnych koncepcji instalacji grzewczo-klimatyzacyjnych dla sali wykładowej. W pierwszej koncepcji głównymi urządzeniami są kolektory słoneczne, sprężarkowa pompa ciepła, podziemny magazyn ciepła wypełniony kamieniami i wodą oraz sondy gruntowe. Drugie rozwiązanie przedstawia połączenie w jeden układ kolektorów słonecznych, sprężarkowej pompy ciepła, trójdzielnego sprzęgła hydraulicznego oraz sond gruntowych. W skład trzeciego rozwiązania weszły sondy gruntowe, kolektory słoneczne, absorpcyjna pompa ciepła oraz kocioł gazowy. Natomiast głównymi elementami czwartego rozwiązania są kompaktowe urządzenia grzewczo-chłodzące, kolektory słoneczne współpracujące z biwalentnym podgrzewaczem wody. Zaprezentowano schematy technologiczne z dobranymi urządzeniami oraz zwrócono uwagę na wady i zalety poszczególnych rozwiązań. Ponadto dla rozwiązania III oraz IV obliczono koszty inwestycyjne, roczne zużycie paliwa konwencjonalnego, emisje zanieczyszczeń do atmosfery oraz oszczędności, które wynikają z wykorzystania odnawialnych źródeł energii.
Źródło:
Ecological Chemistry and Engineering. A; 2010, 17, 11; 1473-1481
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie alternatywnych źródeł energii w instalacjach grzewczo-klimatyzacyjnych
Use of alternative energy sources in heating and air-conditioning installations
Autorzy:
Cholewa, T.
Guz, Ł.
Siuta-Olcha, A.
Powiązania:
https://bibliotekanauki.pl/articles/126872.pdf
Data publikacji:
2009
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
alternatywne źródła energii
kolektory słoneczne
absorpcyjna pompa ciepła
sprężarkowa pompa ciepła
sonda gruntowa
alternative energy sources
solar collectors
absorptive heat pump
air-compressor heat pump
ground probe
Opis:
Jednym z ważniejszych problemów ostatnich lat jest pogodzenie rozwoju cywilizacyjnego społeczeństwa ze środowiskiem naturalnym. Globalne zużycie energii nie odzwierciedla już dziś stopnia rozwoju gospodarczego, a wręcz odwrotnie. Wyznacznikiem postępu naukowo-technicznego danego kraju jest obecnie minimalizacja zużycia energii i jej ekologiczna czystość. Dodatkowo ciągle rosnące ceny nośników energii, degradacja środowiska przyrodniczego oraz zmiany globalne klimatu doprowadziły do wzrostu zainteresowania alternatywnymi źródłami energii. Alternatywne źródła energii można wykorzystywać zarówno do ogrzewania, jak i chłodzenia pomieszczeń. Połączenie tych obu funkcji zaprezentowano za pomocą 4 różnych koncepcji instalacji grzewczo-klimatyzacyjnych dla sali wykładowej. W pierwszej koncepcji głównymi urządzeniami są kolektory słoneczne, sprężarkowa pompa ciepła, podziemny magazyn ciepła wypełniony kamieniami i wodą oraz sondy gruntowe. Drugie rozwiązanie przedstawia połączenie w jeden układ kolektorów słonecznych, sprężarkowej pompy ciepła, trójdzielnego sprzęgła hydraulicznego oraz sond gruntowych. W skład trzeciego rozwiązania weszły sondy gruntowe, kolektory słoneczne, absorpcyjna pompa ciepła oraz kocioł gazowy. Natomiast głównymi elementami czwartego rozwiązania są kompaktowe urządzenia grzewczo-chłodzące, kolektory słoneczne współpracujące z biwalentnym podgrzewaczem wody. Zaprezentowano schematy technologiczne z dobranymi urządzeniami oraz zwrócono uwagę na wady i zalety poszczególnych rozwiązań.
One of the most important problems of last years is the development of society, which is not compatible with environment protection. Total consumption of energy does not reflect already to the degree of economic development. The index of scientifical and technical progress is nowadays the minimization of the energy consumption and its ecological cleanness. Additionally growing prices of energy carriers, the environmental degradation and climate changes make alternative energy sources interesting. Alternative energy sources can be used not only for room heating but also for its cooling. The connection these both functions by means of 4 different ideas of the heating and air-conditioning installation for the existing auditorium is presented. In the first idea main devices are solar collectors, air-compressor heat pump, the underground heat magazine filled with stones and water, and ground probes. The second solution introduces the connection into one system of solar collectors, the air-compressor heat pump, the triple hydraulical coupling and ground probes. Into the third solution entered ground probes, solar collectors, absorptive heat pump and the gas boiler. The main elements of the fourth solution are compact heating and cooling devices and solar collectors, which work with warm water tank. The technological schemas with well-chosen devices are presented and the special attention on advantages and disadvantages of each solution is paid.
Źródło:
Proceedings of ECOpole; 2009, 3, 1; 127-132
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Adsorption chiller in a combined heating and cooling system: simulation and optimization by neural networks
Autorzy:
Krzywanski, Jarosław
Sztekler, Karol
Bugaj, Marcin
Kalawa, Wojciech
Grabowska, Karolina
Chaja, Patryk Robert
Sosnowski, Marcin
Nowak, Wojciech
Mika, Łukasz
Bykuć, Sebastian
Powiązania:
https://bibliotekanauki.pl/articles/2173577.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
adsorption heat pump
polygeneration
cooling capacity
low grade thermal energy
artificial neural networks
soft computing
absorpcyjna pompa ciepła
poligeneracja
wydajność chłodnicza
energia cieplna niskiej jakości
sztuczne sieci neuronowe
przetwarzanie miękkie
Opis:
Adsorption cooling and desalination technologies have recently received more attention. Adsorption chillers, using eco-friendly refrigerants, provide promising abilities for low-grade waste heat recovery and utilization, especially renewable and waste heat of the near ambient temperature. However, due to the low coefficient of performance (COP) and cooling capacity (CC) of the chillers, they have not been widely commercialized. Although operating in combined heating and cooling (HC) systems, adsorption chillers allow more efficient conversion and management of low-grade sources of thermal energy, their operation is still not sufficiently recognized, and the improvement of their performance is still a challenging task. The paper introduces an artificial intelligence (AI) approach for the optimization study of a two-bed adsorption chiller operating in an existing combined HC system, driven by low-temperature heat from cogeneration. Artificial neural networks are employed to develop a model that allows estimating the behavior of the chiller. Two crucial energy efficiency and performance indicators of the adsorption chiller, i.e., CC and the COP, are examined during the study for different operating sceneries and a wide range of operating conditions. Thus this work provides useful guidance for the operating conditions of the adsorption chiller integrated into the HC system. For the considered range of input parameters, the highest CC and COP are equal to 12.7 and 0.65 kW, respectively. The developed model, based on the neurocomputing approach, constitutes an easy-to-use and powerful optimization tool for the adsorption chiller operating in the complex HC system.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 3; art. no. e137054
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Adsorption chiller in a combined heating and cooling system: simulation and optimization by neural networks
Autorzy:
Krzywanski, Jarosław
Sztekler, Karol
Bugaj, Marcin
Kalawa, Wojciech
Grabowska, Karolina
Chaja, Patryk Robert
Sosnowski, Marcin
Nowak, Wojciech
Mika, Łukasz
Bykuć, Sebastian
Powiązania:
https://bibliotekanauki.pl/articles/2128167.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
adsorption heat pump
polygeneration
cooling capacity
low grade thermal energy
artificial neural networks
soft computing
absorpcyjna pompa ciepła
poligeneracja
wydajność chłodnicza
energia cieplna niskiej jakości
sztuczne sieci neuronowe
przetwarzanie miękkie
Opis:
Adsorption cooling and desalination technologies have recently received more attention. Adsorption chillers, using eco-friendly refrigerants, provide promising abilities for low-grade waste heat recovery and utilization, especially renewable and waste heat of the near ambient temperature. However, due to the low coefficient of performance (COP) and cooling capacity (CC) of the chillers, they have not been widely commercialized. Although operating in combined heating and cooling (HC) systems, adsorption chillers allow more efficient conversion and management of low-grade sources of thermal energy, their operation is still not sufficiently recognized, and the improvement of their performance is still a challenging task. The paper introduces an artificial intelligence (AI) approach for the optimization study of a two-bed adsorption chiller operating in an existing combined HC system, driven by low-temperature heat from cogeneration. Artificial neural networks are employed to develop a model that allows estimating the behavior of the chiller. Two crucial energy efficiency and performance indicators of the adsorption chiller, i.e., CC and the COP, are examined during the study for different operating sceneries and a wide range of operating conditions. Thus this work provides useful guidance for the operating conditions of the adsorption chiller integrated into the HC system. For the considered range of input parameters, the highest CC and COP are equal to 12.7 and 0.65 kW, respectively. The developed model, based on the neurocomputing approach, constitutes an easy-to-use and powerful optimization tool for the adsorption chiller operating in the complex HC system.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 3; e137054, 1--11
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies