Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "absorbancja w nadfiolecie" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Założenia technologiczne systemu sterowania procesami koagulacji i flotacji ciśnieniowej w układzie oczyszczania wody
Technological assumptions of coagulation and dissolved air flotation control system in water treatment process
Autorzy:
Kłos, M.
Powiązania:
https://bibliotekanauki.pl/articles/237854.pdf
Data publikacji:
2013
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
water treatment
turbidity
water quality
process control
oczyszczanie wody
mętność
absorbancja w nadfiolecie
sterowanie
Opis:
Based on technical and laboratory scale study results, design recommendations for coagulation and dissolved air flotation control system in water treatment train with high quality variability were presented. Hydrolyzing coagulants, when applied, were demonstrated to require fluent rotational stirrer speed regulation in flocculators. This allows maintenance of adequate floc size which determines bubble-floc agglomerate formation efficacy and their resistance to mechanical tension in the contact zone of flotation tank. In practice, real time rotation regulation in flocculators might be applied, depending on water turbidity or particle number in water fraction leaving flotation tank. Required recirculation factor might be estimated in real time, based on the clarified water quality. However, this solution is very difficult to implement due to many factors that affect efficiency of coagulation and dissolved air flotation processes. It was demonstrated that special attention should be paid to differentiation between the effect of inadequate coagulant dose and the improper recirculation factor. Use of information on the amount and type of suspensions in the intake water, obtained based on UV-absorbance and turbidity measurements, appears to be a better approach.
Na podstawie wyników badań wykonanych w skali laboratoryjnej i technicznej przedstawiono zalecania do projektowania systemu sterowania koagulacją i flotacją ciśnieniową w układzie oczyszczania wody o dużej zmienności jakościowej. Wykazano, że w przypadku stosowania koagulantów hydrolizujących konieczne jest zastosowanie płynnej regulacji prędkości obrotowej mieszadeł w komorach flokulacji. Pozwala to na utrzymanie odpowiedniej wielkości kłaczków, od czego zależy skuteczność powstawania aglomeratów flotacyjnych oraz ich wytrzymałość na naprężenia mechaniczne występujące w strefie kontaktu komory flotacji. W praktyce możliwe jest zastosowanie regulacji obrotów w komorach flokulacji w czasie rzeczywistym w zależności od mętności wody lub liczby cząstek w wodzie opuszczającej komorę flotacji. Wartość wymaganego stopnia recyrkulacji może być określana w czasie rzeczywistym w oparciu o jakość wody sklarowanej. Jednak jest to rozwiązanie bardzo trudne w realizacji z uwagi na to, że na sprawność działania procesów koagulacji i flotacji ciśnieniowej wpływa zbyt wiele czynników. Wykazano, że szczególną uwagę należy zwrócić na rozgraniczenie wpływu nieodpowiedniej dawki koagulantu oraz niewłaściwego stopnia recyrkulacji. Wydaje się, że lepszym rozwiązaniem jest wykorzystanie informacji o ilości i rodzaju zawiesin obecnych w ujmowanej wodzie, uzyskanych na drodze pomiaru absorbancji w nadfiolecie i mętności.
Źródło:
Ochrona Środowiska; 2013, 35, 3; 39-43
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmiany absorbancji w nadfiolecie (UV254) w wodzie w procesach uzdatniania
Autorzy:
Nowacka, A.
Włodarczyk-Makuła, M.
Powiązania:
https://bibliotekanauki.pl/articles/274170.pdf
Data publikacji:
2012
Wydawca:
Roble
Tematy:
woda pitna
jakość wody
uzdatnianie wody
absorbancja w nadfiolecie
drinking water
water quality
water treatment
UV absorbance
Opis:
W pracy przedstawiono wyniki analiz jednego ze wskaźników jakości wody jakim jest absorbancja w nadfiolecie (UV254). Próbki wody pobrano po poszczególnych etapach uzdatniania wody do spożycia przez ludzi w wybranym zakładzie. Średnia wartość absorbancji (UV 1m 254nm) w wodzie surowej wynosiła 11,1. Podczas uzdatniania nastąpiło obniżenie wartości początkowej o 70%, co świadczy o wysokiej skuteczności prowadzonych procesów. Po procesie ozonowania wstępnego i koagulacji objętościowej odnotowano spadek zawartości substancji organicznych wyrażanych badanym wskaźnikiem o 54%, a po ozonowaniu wstępnym i koagulacji kontaktowej - o 56% w stosunku do wartości początkowej oznaczonej dla wody surowej. Zarówno w procesie ozonowania pośredniego i filtracji na węglu aktywnym obniżenie wartości absorbancji w nadfiolecie sięgało 20%.
Źródło:
LAB Laboratoria, Aparatura, Badania; 2012, 17, 1; 28-31
1427-5619
Pojawia się w:
LAB Laboratoria, Aparatura, Badania
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania adsorpcji kwasów humusowych z roztworów wodnych na pylistym węglu aktywnym
Adsorption of humic acids from aqueous solutions onto powdered active carbon
Autorzy:
Perchuć, M.
Król, P.
Grąbczewski, P.
Powiązania:
https://bibliotekanauki.pl/articles/236584.pdf
Data publikacji:
2009
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
kwasy humusowe
absorbancja w nadfiolecie
utlenialność
adsorpcja
pylisty węgiel aktywny
humic acids
color
UV absorbance
COD
adsorption
powdered active carbon
Opis:
Przeprowadzono badania nad wyznaczeniem izoterm adsorpcji kwasów humusowych, ekstrahowanych z węgla brunatnego i torfu, z modelowych roztworów wodnych na węglach pylistych CWZ-22, CWZ-30 I CWH-22 (Gryfskand, Hajnówka). Wyznaczone zależności pomiędzy zawartością kwasów humusowych, barwą i utlenialnością wody oraz absorbancją w nadfiolecie mają istotne znaczenie praktyczne. Pozwalają na wykorzystanie szybkiego oznaczenia, jakim jest absorbancja w nadfiolecie ( =254 nm), do oceny wartości pozostałych wskaźników jakości wody. Otrzymane w testach naczyniowych izotermy adsorpcji stanowiły podstawę do wyboru dawki pylistego węgla aktywnego i warunków prowadzenia procesu sorpcji. Wykazano, że rodzaj występujących w badanych wodach modelowych kwasów humusowych, wynikający z ich pochodzenia (ekstrakt z węgla brunatny lub torfu), miał wpływ na wymaganą dawkę pylistego węgla aktywnego wyznaczoną na podstawie izotermy adsorpcji. Dawki pylistego węgla aktywnego wyznaczone w testach naczyniowych były nieznacznie większe w przypadku wody zawierającej ekstrakt z torfu. Badania nad doborem dawki węgla aktywnego wykazały, że ilość węgla aktywnego potrzebna do uzyskania stężenia równowagowego kwasów humusowych w wodzie oczyszczonej była wprost proporcjonalna do ich stężenia w wodzie surowej.
Humic acids extracted from brown coal and peat were made subject to adsorption from model solutions, using three powdered active carbons (PAC), CWZ-22, CWZ-30 and CWH-22, as adsorbents (Gryfskand, Hajnowka). The relations between humic acid content, color, COD and UV absorbance are of practical significance. They make it possible to use the quick determination of the UV absorbance ( =254 nm) for assessing the values of the other water quality parameters. The isotherms of adsorption obtained in the jar tests enabled the choice of the dosage for the active carbon and the conditions for the sorption process. It has been demonstrated that the type of the humid acids that were present in the model solutions (extract from brown coal or extract from peat) exerted an influence on the carbon dose established on the basis of the adsorption isotherms. The PAC doses determined by the jar tests were slightly higher when the water contained a peat extract. The experiments with the choice of the active carbon dose have revealed that the quantity of the powdered active carbon required for attaining an equilibrium concentration of humic acids in treated water is in direct proportion to their concentration in raw water.
Źródło:
Ochrona Środowiska; 2009, 31, 4; 43-46
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody charakterystyki naturalnych organicznych składników wód ujmowanych z przeznaczeniem do spożycia przez ludzi
Methods for natural organic matter characterization in water taken and treated for human consumption
Autorzy:
Machi, J.
Mołczan, M.
Powiązania:
https://bibliotekanauki.pl/articles/237105.pdf
Data publikacji:
2016
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczanie wody
absorbancja w nadfiolecie
absorbancja właściwa w nadfiolecie
spektroskopia fluorescencyjna
magnetyczny rezonans jądrowy
chromatografia cieczowa
chromatografia wykluczenia
frakcjonowanie jonowymienne
frakcjonowanie membranowe
water treatment
UV absorbance
specific UV absorbance (SUVA)
fluorescence spectroscopy
nuclear magnetic resonance
liquid chromatography
size exclusion chromatography
resin fractionation
membrane fractionation
Opis:
Wiedza o zawartości sumy naturalnych substancji organicznych nie jest obecnie wystarczająca zarówno przy planowaniu, jak i eksploatacji instalacji do oczyszczania wody. Pogłębiona charakterystyka zawartych w ujmowanych wodach naturalnych związków organicznych pozwala na lepsze zrozumienie ich przemian w procesach oczyszczania wody, a także odgrywa bardzo ważną rolę podczas optymalizacji pracy poszczególnych etapów układu technologicznego. Powszechnie stosowanym wskaźnikiem do analizy związków organicznych w wodzie jest absorbancja w nadfiolecie, która umożliwia zarówno ocenę jakościową, jak i ilościową tych związków. Absorbancja właściwa w UV (SUVA), jako odniesienie wartości absorbancji w 254 nm do zawartości w wodzie rozpuszczonego węgla organicznego, umożliwia natomiast kontrolę procesów oczyszczania wody, zwłaszcza w zakresie dawkowania koagulantów oraz utleniaczy. Inne metody charakterystyki naturalnych substancji organicznych stanowią domenę prac badawczych i nie są szerzej wykorzystywane w praktyce funkcjonowania przedsiębiorstw wodociągowych. Wśród nich na uwagę zasługują techniki spektroskopii fluorescencyjnej, które pozwalają na monitorowanie jakości wody w czasie rzeczywistym i cechują się zwiększoną selektywnością oraz czułością w zestawieniu z absorbancją w nadfiolecie. Analiza fluorescencyjna, umożliwiająca identyfikację frakcji biodegradowalnej związków organicznych, pozwala na wybór właściwych metod ich usuwania. Bardzo duże możliwości analityczne zapewnia chromatografia, zwłaszcza w połączeniu z szeroką gamą dostępnych detektorów. Umożliwia ona badanie takich cech substancji organicznych, jak masa cząsteczkowa, polarność, aromatyczność czy podatność na tworzenie ubocznych produktów dezynfekcji wody. Daje to szerokie możliwości interpretacyjne w odniesieniu do optymalizacji pracy układu technologicznego oczyszczania wody. Bardzo pomocne do charakteryzowania składu wody pod względem obecnych w niej związków organicznych są także metody frakcjonowania z wykorzystaniem membran lub żywic selektywnych. Separacja cząsteczek substancji organicznych według takich cech, jak wielkość, hydrofilowość czy kwasowość, pozwala na otrzymanie wyselekcjonowanych próbek, które mogą być poddane dalszym badaniom.
Today’s knowledge on total Natural Organic Matter (NOM) content proves not sufficient both at planning and operation of water treatment installations. Detailed characteristics of NOM present in raw and treated water enables better understanding of its changes during water treatment processes as well as substantially contributes towards operation optimization of subsequent stages of a technological set-up. UV absorbance, a common indicator used for NOM analysis in water, allows for both its qualitative and quantitative assessment. Specific UV absorbance (SUVA), being the UV absorbance of a water sample at 254 nm normalized for dissolved organic carbon (DOC), allows monitoring of water treatment processes, especially in terms of coagulant and oxidizing agent dosing. Other NOM characterization methods are a domain for research and are not widely employed in daily practice of water supply corporations. Among those techniques, fluorescence spectroscopy methods are worth noticing as they enable water quality monitoring in real time and are characterized by higher selectivity and sensitivity compared to UV absorbance. Fluorescence analysis that allows identification of biodegradable organic fractions, enables selection of adequate methods of their removal. Chromatography offers a number of analytical capabilities, especially when combined with a wide range of available detectors. It allows examination of NOM characteristics such as molecular weight, polarity, aromaticity or susceptibility to water disinfection by-product formation. Thus multiple possibilities of interpretation arise in regard to optimization of technological system operation in water treatment. In terms of NOM presence, fractionation methods employing membranes and selective resins are particularly helpful in water composition characterization. NOM particle separation according to its size, hydrophilicity, acidity and others enables monitoring its removal susceptibility in particular treatment processes and predicting the technological effects based on NOM characteristics.
Źródło:
Ochrona Środowiska; 2016, 38, 4; 25-32
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies