Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "ZVS" wg kryterium: Temat


Wyświetlanie 1-8 z 8
Tytuł:
Positive output elementary Luo converter for fixed-frequency ZVS operation
Autorzy:
Bright, S. J. V.
Ramkumar, S.
Anand, H.
Powiązania:
https://bibliotekanauki.pl/articles/200011.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
fixed-frequency ZVS
positive output elementary Luo converter
POELC
zero-voltage switching-pulse width modulation
ZVS-PWM
konwerter Luo
ZVS
Opis:
Luo converter is one amid the developed DC-DC converters offering higher voltage gain. Soft-switching techniques, like zero-voltage switching (ZVS), repress switching losses, and hence the system efficiency and the life of the power semiconductor switches are improved. Incorporation of soft switching in fixed-frequency operation of the Luo converters may persuade them in the regulated power supply applications. The existing variable switching frequency solution suffers from a number of problems viz. complexity in filter designing, more electromagnetic interference (EMI), etc. This paper proposes a positive output elementary Luo converter (POELC) involving ZVS with the wherewithal of working in fixed frequency. A comprehensive discussion on the proposed circuit topology is detailed with both simulation and experimental studies. Systematic descriptions of basic POELC, variable-frequency ZVS-POELC, and fixed-frequency ZVS-POELC make an impact on the understanding of related concepts by the researchers in this field.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2017, 65, 2; 255-262
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ metody sterowania na straty mocy w falowniku napięcia o komutacji miękkiej typu ZVS z dławikami sprzężonymi
Influence of control method on power loss of the inductor-coupled voltage-source ZVS soft-commutated inverter
Autorzy:
Karyś, S.
Powiązania:
https://bibliotekanauki.pl/articles/154917.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
przełączanie miękkie
ZVS
soft switching
Opis:
W artykule poddano analizie matematycznej wpływ metody sterowania na straty mocy trójfazowego falownika o komutacji miękkiej typu ZVS z dławikami sprzężonymi. Przeprowadzona analiza pozwala oszacować wartość o jaką można zredukować straty mocy w łącznikach analizowanego przekształtnika dzięki zastosowaniu metody sterownia o zmiennym czasie trwania sygnałów sterujących - uzależnionym od wartości chwilowej prądu obciążenia. W klasycznej metodzie sterowania czas trwania i położenie sygnałów sterujących jest stałe, niezależne od wartości chwilowej prądu fazowego odbiornika. W efekcie gromadzona jest nadmierna energia w elementach obwodu rezonansowego, której cyrkulacja powoduje straty mocy. Zastosowanie uproszczonego modelu strat pozwoliło na uzyskanie bezpośrednich wyrażeń matematycznych opisujących straty w poszczególnych elementach falownika. Na ich podstawie konstruktor może szybko obliczyć straty oraz sprawność falownika w funkcji: prądu obciążenia, częstotliwości przełączania, parametrów wybranych łączników energoelektronicznych. Na przykładzie konkretnego falownika pokazano, że precyzyjne sterowanie czasem trwania i położeniem sygnałów sterujących umożliwia istotne ograniczenie strat mocy.
This paper presents mathematical analysis of the inductor-coupled voltage-source soft-commutated inverter as regards to control method. The analysis makes it possible to estimate the reduction of the power loss in the switches of the analysed inverter, by using the variable-time control method - depending on instantaneous value of the load current. At classical control method the duration and the location of the control signals are constant, independent of the instantaneous value of the load current. In the result, superfluous energy has been accumulated in the resonant tank elements. Energy circulation produces power loss. Loss in particular inverter elements is directly expressed by mathematical equation thanks to the simplified model of the power loss. Designer can quickly compute the loss and efficiency versus the load current, switching frequency, and parameters of switches. On the example of the definite inverter it is shown that precise control of the duration and location of the control signals contributes to real power loss reduction.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 9, 9; 744-749
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Three-phase soft-switching inverter with coupled inductors, experimental results
Autorzy:
Karyś, S.
Powiązania:
https://bibliotekanauki.pl/articles/200045.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
soft-switching
resonant inverter
ZVS inverter
Opis:
This paper presents experimental results of the three-phase soft-switching inverter with coupled inductors that verify the control method influence on efficiency improvement. Different kinds of control methods were tested on the 6 kW experimental inverter. A short discussion on a few design methods of the resonant tank elements was made. Experimental results confirm that the advanced control algorithm and the proposed new design method of the resonant tank elements significantly increase the efficiency of this resonant inverter.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2011, 59, 4; 535-540
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Advanced control and design methods of the auxiliary resonant commutated pole inverter
Autorzy:
Karyś, S.
Powiązania:
https://bibliotekanauki.pl/articles/201964.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
soft switching
ARCP
ZVS
miękkie przełączanie
tranzystor
Opis:
This paper presents several methods that enable the reduction of power loss in the auxiliary resonant commutated pole inverter - ARCP. Presented methods can be divided into static and dynamic ones. The static methods are related to an appropriate design of the inverter, whereas dynamic ones to advanced control of the power transistors. A variety of design and control methods are presented together with their advantages and disadvantages. The new control method of the current in the resonant branch is described. The main benefits of the proposed extended control method and their constrains are shown.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2015, 63, 2; 489-494
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multiresonant ZVS boost converter
Autorzy:
Szychta, E.
Powiązania:
https://bibliotekanauki.pl/articles/262727.pdf
Data publikacji:
2005
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
multiresonant converter
zero voltage switching
ZVS
resonant circuits
Opis:
The article presents properties ofmultiresonant voltage-increasing converter to be ! applied in DC voltage supply systems. The configuration of the system elements enables application ! of the technique of zero voltage switching (ZVS) of semi-conductor elements, which yields high operating frequencies of the system while maintaining high energy efficiency and reliability of operation. Results of simulation tests of the converter, based on Simplorer, are discussed. Regulation characteristics are presented and the converter's efficiency is determined.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2005, 11, 2; 65-71
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A predictive estimation based control strategy for a quasi-resonant dc-link inverter
Autorzy:
Turzyński, M.
Banach, P.
Murawski, P.
Pepliński, R.
Chrzan, P. J.
Powiązania:
https://bibliotekanauki.pl/articles/200484.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
resonant converters
ZVS three-phase inverter
current estimation
Opis:
Control of parallel quasi resonant dc link inverters (PQRDCLI) is usually based on dc link input inverter current. Instead of a direct measurement of this noise sensitive and fast changing current signal - its estimation with one step prediction may be considered. Estimation of an input inverter current is based on inverter output current measurements, applied in most of power electronics controlled ac drives. In this paper, the PQRDCLI fed induction motor (IM) with a predictive current estimation stabilizes resonant inverter output voltage slopes du/dt independently of load. By control of output voltage derivatives, reduction of overvoltage spikes and common mode motor currents is achieved. An analysis of the PQRDCLI control with a predictive current estimation strategy is verified by the Saber system simulation and experimental tests in a laboratory setup.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2013, 61, 4; 757-762
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of operation of class E ZVS resonant inverter
Autorzy:
Szychta, E.
Powiązania:
https://bibliotekanauki.pl/articles/262645.pdf
Data publikacji:
2005
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
class E ZVS resonant
inverter
output capacitance
MOSFET transistor
zero voltage switching
Opis:
The article discusses class E zero-voltage-switching resonant inverter (ZVS). The resonant circuit of the inverter is subject to mathematical analysis using the method of state variables with the aid of MATLAB software. Results of simulation testing, based on Simplorer software, of an inverter at the operating frequency of 100kHz are presented.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2005, 11, 1; 57-67
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
High-Frequency Power Amplitude Modulators with Class-E Tuned Amplifiers
Autorzy:
Modzelewski, J.
Mikołajewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/307948.pdf
Data publikacji:
2008
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
high-efficiency amplitude modulators
non-ZVS operation
optimum operation
PSpice simulations
suboptimum operation
Opis:
A high-frequency power amplifier used in a drain amplitude modulator must have linear dependence of output HF voltage Vo versus its supply voltage VDD. This condition essential for obtaining low-level envelope distortions is met by a theoretical class-E amplifier with a linear shunt capacitance of the switch. In this paper the influence of non-linear output capacitance of the transistor in the class-E amplifier on its Vo(VDD) characteristic is analyzed using PSPICE simulations of the amplifiers operating at frequencies 0.5 MHz, 5 MHz and 7 MHz. These simulations have proven that distortions of theVo(VDD) characteristic caused by non-linear output capacitance of the transistor are only slight for all analyzed amplifiers, even for the 7 MHz amplifier without the external (linear) shunt capacitance. In contrast, the decrease of power efficiency of the class-E amplifier resulting from this effect can be significant even by 40%
Źródło:
Journal of Telecommunications and Information Technology; 2008, 4; 79-86
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies