Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "XANES" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Synchrotron microanalytical methods in the study of trace and minor elements in apatite
Autorzy:
Rakovan, John
Luo, Yun
Borkiewicz, Olaf
Powiązania:
https://bibliotekanauki.pl/articles/2086519.pdf
Data publikacji:
2008
Wydawca:
Polskie Towarzystwo Mineralogiczne
Tematy:
synchrotron
microanalysis
XRF
EXAFS
XANES
apatite
Opis:
Synchrotron X-ray facilities have the capability for numerous microanalytical methods with spatial resolutions in the micron to submicron range and sensitivities as low as ppm to ppb. These capabilities are the result of a high X-ray brilliance (many orders of magnitude greater than standard tube and rotating anode sources); a continuous, or white, spectrum through the hard X-ray region; high degrees of X-ray columniation and polarization; and new developments in X-ray focusing methods. The high photon flux and pulsed nature of the source also allow for rapid data collection and high temporal resolution in certain experiments. Of particular interest to geoscientists are X-ray fluorescence microprobes which allow for numerous analytical techniques including X-ray fluorescence (XRF) analysis of trace element concentrations and distributions; X-ray absorption spectroscopy (XAS) for chemical speciation, structural and oxidation state information; X-ray diffraction (XRD) for phase identification; and fluorescence microtomography (CMT) for mapping the internal structure of porous or composite materials as well as elemental distributions (Newville et al. 1999; Sutton et al. 2002; Sutton et al. 2004). We have employed several synchrotron based microanalytical methods including XRF, microEXAFS (Extended X-ray Absorption Fine Structure), microXANES (X-ray Absorption Near Edge Structure) and CMT for the study of minor and trace elements in apatite (and other minerals). We have also been conducting time resolved X-ray diffraction to study nucleation of and phase transformations among precursor phases in the formation of apatite from solution at earth surface conditions. Summaries of these studies are given to exemplify the capabilities of synchrotron microanalytical techniques.
Źródło:
Mineralogia; 2008, 39, 1/2; 31--40
1899-8291
1899-8526
Pojawia się w:
Mineralogia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Synchrotron microanalytical methods in the study of trace and minor elements in apatite
Autorzy:
Rakovan, J.
Luo, Y.
Borkiewicz, O.
Powiązania:
https://bibliotekanauki.pl/articles/2086554.pdf
Data publikacji:
2008
Wydawca:
Polskie Towarzystwo Mineralogiczne
Tematy:
synchrotron
microanalysis
XRF
EXAFS
XANES
apatite
Opis:
Synchrotron X-ray facilities have the capability for numerous microanalytical methods with spatial resolutions in the micron to submicron range and sensitivities as low as ppm to ppb. These capabilities are the result of a high X-ray brilliance (many orders of magnitude greater than standard tube and rotating anode sources); a continuous, or white, spectrum through the hard X-ray region; high degrees of X-ray columniation and polarization; and new developments in X-ray focusing methods. The high photon flux and pulsed nature of the source also allow for rapid data collection and high temporal resolution in certain experiments. Of particular interest to geoscientists are X-ray fluorescence microprobes which allow for numerous analytical techniques including X-ray fluorescence (XRF) analysis of trace element concentrations and distributions; X-ray absorption spectroscopy (XAS) for chemical speciation, structural and oxidation state information; X-ray diffraction (XRD) for phase identification; and fluorescence microtomography (CMT) for mapping the internal structure of porous or composite materials as well as elemental distributions (Newville et al. 1999; Sutton et al. 2002; Sutton et al. 2004). We have employed several synchrotron based microanalytical methods including XRF, microEXAFS (Extended X-ray Absorption Fine Structure), microXANES (X-ray Absorption Near Edge Structure) and CMT for the study of minor and trace elements in apatite (and other minerals). We have also been conducting time resolved X-ray diffraction to study nucleation of and phase transformations among precursor phases in the formation of apatite from solution at earth surface conditions. Summaries of these studies are given to exemplify the capabilities of synchrotron microanalytical techniques.
Źródło:
Mineralogia; 2008, 39, 1/2; 31--40
1899-8291
1899-8526
Pojawia się w:
Mineralogia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
XAFS in the tracking of reactions in aqueous solution: a case of redox reaction between [AuCl4]- complex ions and ethanol
Metoda XAFS w badaniach reakcji zachodzących w roztworach wodnych: przykład reakcji redoks pomiędzy jonami kompleksowymi [AuCl4]- i alkoholem etylowym
Autorzy:
Pacławski, K.
Sikora, M.
Powiązania:
https://bibliotekanauki.pl/articles/355830.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
XAFS
XANES
redox reaction
gold complex ions
ethanol
Opis:
In this work the potential application of synchrotron radiation in the studies of reaction kinetics in aqueous phase were presented. After short introduction describing principles of technique and potential application of XAFS for the structural studies of reacting species, the experimental results of kinetic measurements of reaction between gold(III) chloride complex ions and ethanol were presented. Analyzing the changes of absorption intensity in the XANES spectra registered at Au-L &sub3; edge during the reaction, the change of the valence state of Au central atom (form 3+to 0) of reacting complex ion was determined. Moreover, empirical XANES data gave the chance to register the kinetic curve and to determine the rate constant of the studied reaction. It was found that reaction is relatively slow (second-order rate constant k = 3.66 · 10 &sup-5; M ;sup-1;s) and lead to the gold metallic phase formation in the system. Applying the continuous-flow method, within the first 600 ms of reaction the changes in XANES spectra were registered. From the obtained results, supported with numerical calculations, two intermediate forms of adducts appearing prior the electron transfer were suggested. It was concluded that when the classic methods, e.g. UV-Vis spectrophotometry, cannot be applied to studies of kinetics of reactions in aqueous solution, the XAFS technique can be a valuable and substitutive (or supplementary) tool for such measurements.
W pracy przedstawiono potencjalne możliwości zastosowania promieniowania synchrotronowego w badaniach nad kinetyka reakcji przebiegających w roztworach wodnych. We wstępie, omówiono podstawy techniki rentgenowskiej analizy struktury nadsubtelnej (XAFS) i jej możliwości zastosowania w badaniach strukturalnych związków chemicznych w fazie ciekłej. Zaprezentowano również dane eksperymentalne z pomiarów XAFS dotyczące kinetyki reakcji pomiędzy chlorkowymi kompleksami złota(III) i alkoholem etylowym. Z analizy zmian intensywności absorpcji widm XANES rejestrowanych przy krawędzi L &sub3; złota określono zmianę stopnia utlenienia atomu centralnego Au (z 3+ do 0) reagującego kompleksu. Ponadto, dane empiryczne pozwoliły na wyznaczenie krzywej kinetycznej oraz określenie drugorzędowej wartości stałej szybkości reakcji (k = 3.66 ·10 &sup-5; M &sup-1;s). W wyniku analizy widm XANES potwierdzono powstawanie faza metalicznej złota w układzie. Stosując metodę ciągłego przepływu reagentów, zarejestrowano zmiany w widmie XANES w ciągu 600 ms od rozpoczęcia reakcji.Na podstawie zarejestrowanych widm oraz przeprowadzonych obliczeń numerycznych zasugerowano dwie możliwe struktury adduktu tworzącego się przed właściwym transferem elektronu w reakcji redoks. Z przeprowadzonych eksperymentów wynika, ze w układach, w których nie jest możliwe stosowanie spektrofotometrii UV-Vis, metoda XAFS może być zastępczym i obiecującym narzędziem do badań kinetyki reakcji.
Źródło:
Archives of Metallurgy and Materials; 2012, 57, 4; 1011-1020
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The complementary structural studies of the double metal cyanide type catalysts for the ring opening polymerization of the oxiranes
Komplementarne badania strukturalne dimetalocyjankowych katalizatorów polimeryzacji z otwarciem pierścienia oksiranowego
Autorzy:
Chruściel, A.
Hreczuch, W.
Czaja, K.
Ławniczak-Jabłońska, K.
Janik, J.
Powiązania:
https://bibliotekanauki.pl/articles/947469.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Chemii Przemysłowej
Tematy:
double metal cyanide catalysts (DMC)
thermal analysis
thermogravimetric analysis (TG)
differential scanning calorimetry (DSC)
evolved gas analysis (EGA)
X-ray absorption spectroscopy (XAS)
X-ray absorption near edge structure (XANES)
extended X-ray absorption fine structure (EXAFS)
katalizatory dimetalocyjankowe (DMC)
analiza termiczna
analiza termograwimetryczna (TGA)
różnicowa kalorymetria skaningowa (DSC)
analiza wydzielanych gazów (EGA)
rentgenowska absorpcyjna spektroskopia struktury przykrawędziowej (XANES)
synchrotronowa absorpcyjna spektroskopia rentgenowska (EXAFS)
Opis:
The extensive complementary experimental studies of the double metal catalysts (DMC) with two kinds of the organic ligands were performed. The chemical justification of the observed TG/DSC (thermogravimetric analysis/differential scanning calorimetry) steps was proposed. Several organic ligand complexing states were found in both types of catalysts. X-ray absorption spectroscopy (XAS) analysis established that only Zn atoms are the active metallic centers in DMC catalyst regardless the used ligand. Cl atoms were detected near some of Zn atoms. Contrary to the common suppositions no significant amount of oxygen atoms was detected in the closest coordination spheres of Zn.
Przeprowadzono badania strukturalne katalizatorów dimetalocyjankowych (DMC) z dwoma rodzajami ligandów organicznych. Zaproponowano wyjaśnienie etapów przebiegu krzywych otrzymanych metodą analizy termograwimetrycznej i różnicowej kalorymetrii skaningowej (TG/DSC) badanych katalizatorów. Wykazano obecność kilku stopni związania ligandów w kompleksach DMC. Na podstawie wyników badań z wykorzystaniem absorpcji rentgenowskiej (XAS) stwierdzono, że centrum aktywne katalizatora stanowi atom cynku. W bezpośrednim sąsiedztwie atomów Zn wykryto obecność atomów Cl, natomiast w najbliższych sferach koordynacyjnych atomu Zn nie wykryto atomów tlenu.
Źródło:
Polimery; 2016, 61, 6; 421-432
0032-2725
Pojawia się w:
Polimery
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies