Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "X-ray method" wg kryterium: Temat


Tytuł:
Importance of wheat grain orientation for the detection of internal mechanical damage by the X-ray method
Autorzy:
Grundas, S.
Velikanov, L.
Archipov, M.
Powiązania:
https://bibliotekanauki.pl/articles/25784.pdf
Data publikacji:
1999
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
grain hardness
internal damage
X-ray method
mechanical damage
wheat grain
Źródło:
International Agrophysics; 1999, 13, 3
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of studies on the mechanical properties of winter rape stems
Autorzy:
Skubisz, G.
Powiązania:
https://bibliotekanauki.pl/articles/24479.pdf
Data publikacji:
2001
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
oilseed rape
winter oilseed rape
X-ray method
development
stem
rigidity
shearing energy
stress
mechanical property
Źródło:
International Agrophysics; 2001, 15, 3
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczanie naprężeń własnych w wyrobach metalowych metodą rentgenowską
Determination of stresses in metal products by the x-ray method
Autorzy:
Samolczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/212246.pdf
Data publikacji:
2006
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Obróbki Plastycznej
Tematy:
odkształcenie
makronaprężenia
metoda sin2Ψ
rentgenowskie stałe sprężystości
profile linii dyfrakcyjnych
strain
macrostresses
sin2[psi] method
X-ray elastic constants
profiles of diffraction lines
Opis:
Rentgenograficzne metody pomiaru makronaprężeń są powszechnie stosowane w badaniach, nie tylko próbek polikrystalicznych, lecz również w częściach maszyn. Omówiono zagadnienia naprężeń własnych materiałów polikrystalicznych. Pokazano zasady pomiaru naprężeń własnych przy zastosowaniu goniometru typu EG 4/201 w klasycznej dyfraktometrycznej tzw. metodzie sin 2y. Na podstawie zapisów dyfrakcyjnych obliczono wartości naprężeń własnych. Przebiegi naprężeń własnych są zgodne pod względem charakteru jak i wartości, z przebiegami wyznaczonymi przez innych autorów.
X-ray methods of macrostress measurement are widely applied not only for polycrystalline samples but also for parts of machines. In this paper principles of internal stress measurement using EG 4/201 goniometer and sin 2y method have been described. Internal stresses have been calculated based on diffractogram patterns. The results obtained in this work are in good agreement with those obtained by others.
Źródło:
Obróbka Plastyczna Metali; 2006, 17, 1; 35-39
0867-2628
Pojawia się w:
Obróbka Plastyczna Metali
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie mikroanalizy rentgenowskiej (EDX) w badaniach składu chemicznego wybranych materiałów budowlanych
Application of the energy dispersive x-ray (EDX) in the chemical analysis of the building materials
Autorzy:
Rożniakowski, K.
Klemm, P.
Polański, K.
Powiązania:
https://bibliotekanauki.pl/articles/362732.pdf
Data publikacji:
2007
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
zabytkowa zabudowa przemysłowej Łodzi
cegła
skład chemiczny
spektrometria EDX
chemical composition
brick
Energy Dispersive X-ray method
Opis:
W pracy przedstawiono wyniki badań składu chemicznego próbek cegły pochodzącej z zespołu zabytkowej zabudowy przemysłowej Łodzi, mieszczącej się przy ulicy Wólczanskiej 215. W badaniach stosowano spektrometrię EDX (Energy Dispersive X-ray). Zaobserwowano znaczne różnice składu chemicznego warstwy wierzchniej i wnętrza materiału.
The work presents the results of experimental examinations of the chemical composition of the brick samples. The samples are genesis from Łódź old age buildings, placed Wólczańska 215 street. The Energy Dispersive X-ray method was used. Large differences between chemical composition of the surface layer and inside of the sample were observed.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2007, T. 2; 243-246
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Podatność ziarna pszenicy i pszenżyta na uszkodzenia bielma oznaczana metodą rentgenograficzną
Susceptibility of wheat and triticale grain to inner mechanical damage by using the X-ray method
Autorzy:
Grundas, S.
Gruszecka, D.
Kowalczyk, K.
Niewiadomski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/35564.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
pszenica
pszenzyto
ziarno
uszkodzenia ziarna
bielmo
podatnosc na uszkodzenia
metody rentgenograficzne
wheat
triticale
grain
grain damage
endosperm
damage susceptibility
X-ray method
Opis:
Artykuł zawiera wyniki rentgenograficznych badań podatności ziarna pszenicy i pszenżyta na powstawanie uszkodzeń bielma. Materiał pochodził z doświadczeń polowych (eksperyment 1) przeprowadzonych w Stacji Hodowli Roślin w Laskach, w latach 2005-2007 oraz z doświadczeń prowadzonych na mieszańcach pszenżyta przez Instytut Genetyki, Hodowli i Biotechnologii Roślin UP w Lublinie w roku 2009 (eksperyment 2). Zarejestrowany metodą rentgenowską udział ziarniaków z pęknięciami poprzecznymi bielma wskazuje na genetyczne uwarunkowanie tego typu uszkodzeń.
The paper presents the results of X-ray investigations of wheat and triticale grain susceptibility to endosperm damage. The experimental material originated from field experiments carried out at the Plant Breeding Station in Laski in 2005-2007 (experiment 1), and from experiments carried out on grain hybrids of Triticale at the Institute of Genetics, Breeding and Plants Biotechnology at the University of Life Sciences in Lublin, in 2009 (experiment 2). The share of kernels with inner cracks, registered with the X-ray method, indicates an influence of genetic factors on the occurrence of this kind of damage.
Źródło:
Acta Agrophysica; 2011, 18, 2[193]
1234-4125
Pojawia się w:
Acta Agrophysica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simulation of computed tomography (CT) images using a Monte Carlo approach
Autorzy:
Wysocka-Rabin, A. M.
Qamhiyeh, S.
Jäkel, O.
Powiązania:
https://bibliotekanauki.pl/articles/147601.pdf
Data publikacji:
2011
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
X-ray tomography
Monte Carlo (MC) method
treatment planning
hadrontherapy
Opis:
Heavy ion treatment planning uses an empirical scanner-dependent calibration relation between computed tomography (CT) numbers and ion range. Any deviation in the values of CT numbers will cause a drift in the calibration curve of the CT scanner, which can reduce the accuracy of treatment beam delivery. To reduce uncertainty in the empirical estimation of CT numbers, we developed a simulation that takes into consideration the geometry, composition, and physical process that underlie their measurement. This approach uses Monte Carlo (MC) simulations, followed by a simple filtered back-projection reconstruction. The MC code used is BEAMnrc/EGSnrc. With the manufacturer’s permission, we simulated the components (X-ray tube, associated filters and beam shapers) of a Siemens Emotion CT. We then generated an initial beam shape and spectra, and performed further simulations using the phantom with substitutes. We analyzed the resulting phase space file to calculate projections, taking into account the energy response of the CT detectors. Then, we applied a simple reconstruction algorithm to the calculated projections in order to receive the CT image.
Źródło:
Nukleonika; 2011, 56, 4; 299-304
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmiany poziomu naprężeń własnych w stemplach do wyciskania przeciwbieżnego wyrobów z cynku
Variations of internal stresses in punches for backward extrusion of zinc products
Autorzy:
Samolczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/211800.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Obróbki Plastycznej
Tematy:
stempel do wyciskania przeciwbieżnego
metoda dyfrakcji rentgenowskiej
naprężenia własne
warstwa powierzchniowa
backward extrusion punch
X-ray diffraction method
internal stresses
surface layer
Opis:
W artykule przedstawiono wyniki badań naprężeń własnych w warstwie powierzchniowej stempli do wyciskania przeciwbieżnego wyrobów z cynku. Pomiarów naprężeń dokonano rentgenowską metodą sin 2, która okazała się przydatną do wyznaczania naprężeń własnych w stemplach do wyciskania przeciwbieżnego metali. W przypadku stempli do wyciskania przeciwbieżnego wyrobów z cynku, czas eksploatacji narzędzi wyraźnie zależy od rodzaju naprężeń panujących w ich warstwie wierzchniej. Naprężenia ściskające przy powierzchni zapewniają bezpieczną eksploatację stempli do wyciskania. Zmiana naprężeń ściskających na naprężenia rozciągające w warstwie wierzchniej powoduje przyspieszenie zużycia narzędzi.
The paper presents the results of investigation of internal stresses in the surface layer of punches for backward extrusion of zinc products. Stress measurements have been effected by the x-ray sin 2 method which proved to be suitable for the determination of internal stresses in punches for backward extrusion of metals. In the case of the punches for backward extrusion of zinc products, the tool exploitation time is clearly dependent on the kind of stresses present in their surface layer. Compressive stresses at the surface result in safe exploitation of extrusion punches. The change of compressive stresses into tensile ones accelerates the tool wear.
Źródło:
Obróbka Plastyczna Metali; 2011, 22, 4; 255-268
0867-2628
Pojawia się w:
Obróbka Plastyczna Metali
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania identyfikacyjne materiałów wiążących na bazie cementu
Identification tests of cement-based binders
Autorzy:
Babińska, J.
Powiązania:
https://bibliotekanauki.pl/articles/182847.pdf
Data publikacji:
2012
Wydawca:
Instytut Techniki Budowlanej
Tematy:
materiał wiążący
cement
badanie identyfikacyjne
metoda badań
wymagania normowe
klej cementowy
analiza termiczna
XRD
binding material
identification test
test method
standard requirements
cement-based adhesive
thermal analysis
X-ray diffractometry
Opis:
Badania identyfikacyjne są kluczowe w badaniach aprobacyjnych oraz w przypadku spraw spornych dotyczących jakości materiału budowlanego. Zalicza się do nich między innymi metody instrumentalne, obejmujące takie badania jak dyfrakcja rentgenowska, badania w podczerwieni oraz analiza termiczna. Metody instrumentalne stosowane kompleksowo pozwalają na pełne odwzorowanie składu fazowego badanych próbek, natomiast stosowane pojedynczo mogą pełnić rolę fingerprintu. Wybór metod identyfikacyjnych jest ściśle uzależniony od składu badanego materiału i celu badania, co zostało pokazane na przykładzie klejów cementowych stosowanych w systemach ociepleń.
Identification tests depending on the type and application can be divided into several groups. Instrumental methods including the X-ray diffraction, infrared testing and thermal analysis are ones of them. They give relatively the most complete picture of the phase composition. The choice of identification method is strictly dependent on the composition of the material, as it was shown on the example of cement-based adhesives used in thermal insulation systems.
Źródło:
Prace Instytutu Techniki Budowlanej; 2012, R. 41, nr 3, 3; 3-15
0138-0796
Pojawia się w:
Prace Instytutu Techniki Budowlanej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical study on closed cell foam structure damage mechanisms
Autorzy:
Miedzińska, D.
Powiązania:
https://bibliotekanauki.pl/articles/246654.pdf
Data publikacji:
2012
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
closed cell foam
finite element method
X-ray tomography
damage
Opis:
Metallic foams are currently being looked at as a new material for automobiles. The main goal of the use of metallic foams in vehicles is to increase sound dampening, reduce the weight of the automobile, and increase energy absorption in case of crashes, or in military applications, to combat the concussive force of IEDs. The metallic foams that are being looked at currently, are aluminum and its alloys due to their low density (0.4-0.9 g/cm3). In addition these foams have a high stiffness, are fire resistant, do not give off toxic fumes, are fully recyclable, have high energy absorbance, have low thermal conductivity, have low magnetic permeability, and are efficient at sound dampening, especially in comparison to light weight hollow parts. In addition, partial addition of metallic foams in hollow parts of the car will decrease weakness points usually associated with car crashes and noisy vibrations. These foams are cheap to cast by using powder metallurgy (as compared to casting of other hollow parts). The aim of the research was to describe and to assess the main mechanisms that appear in the foam structure during the compression. The development process of the finite element model of the closed cell foam microstructure is presented in the paper. The model geometry was based on the real structure research, which was carried out with the use of computed tomography. The model was built with the use of a unique computer code created to transform the scan point cloud into FE raster model based on solid 8-node elements. The experimental and numerical compression test results were compared and showed good compatibility. The stress distributions were studied to describe the main mechanisms in the structure.
Źródło:
Journal of KONES; 2012, 19, 2; 321-327
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
X-Ray Diffraction Measurements for Riveted Joints. The Application of a Novel Methodology
Autorzy:
Gadalińska, E.
Kaniowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/97767.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Lotnictwa
Tematy:
X-ray diffraction method
stress measurements
riveted joints
Opis:
The X-ray diffraction method is the best, widely available, non-destructive measurement method used to determine the residual and load stresses in crystalline materials. This method can be applied without any limitations to flat specimens. Depending on the equipment geometry, the type of material and geometry of the specimen, there are many limitations, restrictions and recommendations which have to be fulfilled to obtain reliable results. This was the reason for working out a methodology for X-ray diffraction stress measurements for riveted specimens.The first case to analyze is the necessity of choosing an X-ray tube suitable for the specimen material which will give the diffraction peaks in the range of 2Θ angles between 120° and 180°. Afterwards it is crucial to make the best selection of Bragg's angle 2Θ. In the vast majority of cases the best selection is the possibly biggest 2Θ angle because of the best accuracy of the measurement. However, for example for aluminum alloys (for CrKα radiation), this choice is not so obvious. It is much more convenient to perform measurements not for the highest diffraction angle. The best selection in this case is 2Θ=139,3°, and not 156,7°. Other selections which are necessary to be made before measurements are the collimator diameter, time of exposure, ψ tilts and φ oscillations. The proper selection of these parameters is crucial for the fast and efficient performing of measurements and for obtaining reliable results. Before performing the measurement, especially in the case of the specimen with complicated geometry (for example in the case of riveted specimens made of aluminum alloys), it is necessary to analyze the results obtained paying special attention to the possibility of the appearing of the rivet head/driven rivet head shadow during the measurement. The work describes differences between the X-ray stress measurement results obtained without any interference and the results received after eliminating the selected diffraction peaks for which the shadow of rivet head/driven rivet head has appeared.
Źródło:
Fatigue of Aircraft Structures; 2012, 4; 17-28
2081-7738
2300-7591
Pojawia się w:
Fatigue of Aircraft Structures
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rated stress state of functional surfaces by X-ray diffractometric methods
Pomiar naprężenia własnego w warstwie wierzchniej metodami dyfraktometrii rentgenowskiej
Autorzy:
Kurňava, P
Stančeková, D
Nosák, T
Jurky, M
Powiązania:
https://bibliotekanauki.pl/articles/175628.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
X-ray diffractometric method
stresses
bearings
rolling bearings
metoda dyfraktometrii rentgenowskiej
naprężenia
łożyska
łożyska toczne
Opis:
This work deals with investigation of residual stresses during by non-destructive methods turning. Workpiece material, which was used in experiments was 19 830 steel, which is used for rolling bearing rings. Residual stress were observed in the application of various cutting parameters by non-destructive methods.
W pracy prowadzono badania naprężeń własnych w warstwie wierzchniej w procesie toczenia przy zastosowaniu metod nieniszczących – metody dyfrakcji rentgenowskiej. W badaniach stosowano stal 19 830 do wytwarzania pierścieni łożysk tocznych. Pomiar wartości naprężenia prowadzono na powierzchni obrobionej przy stosowaniu różnych wartości parametrów skrawania.
Źródło:
Advances in Manufacturing Science and Technology; 2013, 37, 2; 33-49
0137-4478
Pojawia się w:
Advances in Manufacturing Science and Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka mineralogiczna obecnie stosowanych rud w hutnictwie żelaza
Mineralogical characteristics of ores currently used in the iron and steel industry
Autorzy:
Krztoń, H.
Stecko, J.
Gazdowicz, J.
Kania, Z.
Powiązania:
https://bibliotekanauki.pl/articles/181750.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Metalurgii Żelaza im. Stanisława Staszica
Tematy:
rudy hematytowe kawałkowe
dyfrakcja rentgenowska
metoda Rietvelda
mikroskopia skaningowa
analiza chemiczna w mikroobszarach
lump hematite ores
X-ray diffraction
Rietveld method
scanning microscopy
chemical analysis in micro-areas
Opis:
Przeprowadzono badania składu mineralnego dla rud hematytowych kawałkowych z pięciu różnych złóż – trzech ukraińskich, jednego z RPA i z Liberii. Wykorzystano metodę dyfrakcji rentgenowskiej do identyfikacji minerałów oraz metodę Rietvelda do obliczenia udziałów poszczególnych składników mineralnych w badanych rudach. Zastosowano mikroskopię skaningową z analizą chemiczną w mikroobszarach do badania składu chemicznego minerałów.
The investigations of mineral composition were carried out for lump hematite ores from five different deposits –three in Ukraine, one in South Africa, and one in Liberia. The X-ray diffraction method for identification of minerals and the Rietveld method for calculation of contents of individual mineral components in the ores under investigation were used. Scanning microscopy with chemical analysis in micro-areas was used for investigation of chemical compositions of minerals.
Źródło:
Prace Instytutu Metalurgii Żelaza; 2014, T. 66, nr 4, 4; 34-56
0137-9941
Pojawia się w:
Prace Instytutu Metalurgii Żelaza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monte Carlo calculated CT numbers for improved heavy ion treatment planning
Autorzy:
Qamhiyeh, S.
Wysocka-Rabin, A.
Jäkel, O.
Powiązania:
https://bibliotekanauki.pl/articles/148658.pdf
Data publikacji:
2014
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
X-ray tomography
Monte Carlo (MC) method
treatment planning
hadrontherapy
Opis:
Better knowledge of CT number values and their uncertainties can be applied to improve heavy ion treatment planning. We developed a novel method to calculate CT numbers for a computed tomography (CT) scanner using the Monte Carlo (MC) code, BEAMnrc/EGSnrc. To generate the initial beam shape and spectra we conducted full simulations of an X-ray tube, filters and beam shapers for a Siemens Emotion CT. The simulation output files were analyzed to calculate projections of a phantom with inserts. A simple reconstruction algorithm (FBP using a Ram-Lak filter) was applied to calculate the pixel values, which represent an attenuation coefficient, normalized in such a way to give zero for water (Hounsfield unit (HU)). Measured and Monte Carlo calculated CT numbers were compared. The average deviation between measured and simulated CT numbers was 4 ± 4 HU and the standard deviation σ was 49 ± 4 HU. The simulation also correctly predicted the behaviour of H-materials compared to a Gammex tissue substitutes. We believe the developed approach represents a useful new tool for evaluating the effect of CT scanner and phantom parameters on CT number values.
Źródło:
Nukleonika; 2014, 59, 1; 15-23
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Szczególne przypadki wad materiałów wybuchowych
Particular cases of explosives materials defects
Autorzy:
Krysiński, B.
Kamieńska-Duda, A.
Powiązania:
https://bibliotekanauki.pl/articles/235915.pdf
Data publikacji:
2014
Wydawca:
Wojskowy Instytut Techniczny Uzbrojenia
Tematy:
amunicja
olej trotylowy
wypylenie
metoda rentgenograficzna
ammunition
TNT oil
dusting
X-ray method
Opis:
W artykule przedstawiono wybrane przypadki defektów materiałów wybuchowych znajdujących się w elementach amunicji, które powstały na etapie ich produkcji lub w procesie eksploatacji. Wojskowy Instytut Techniczny Uzbrojenia posiada nowoczesną aparaturę diagnostyczną, za pomocą której możliwe było wykrycie wad różnego rodzaju materiałów wybuchowych. Aparaturą zastosowaną w naszej pracy był wysokiej klasy rentgenograf pozwalający na prześwietlenie amunicji w celu określenia jakości zaelaborowanego materiału oraz kontroli poszczególnych podzespołów.
In this article there are shown particular cases of defects of high explosives contained in ammunition. The defects arose during production or exploitation process. Military Institute of Armament Technology possesses new diagnostic apparatus to detect flaws of different origin. This high standard X-Ray apparatus was used to determine quality of elaborated material and control individual particular components and some results are presented in our paper.
Źródło:
Problemy Techniki Uzbrojenia; 2014, 43, 130; 59-65
1230-3801
Pojawia się w:
Problemy Techniki Uzbrojenia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmodyfikowana metoda dodatku wzorca w analizie rentgenofluorescencyjnej
Autorzy:
Mzyk, Z.
Anyszkiewicz, J.
Gorewoda, T
Powiązania:
https://bibliotekanauki.pl/articles/273745.pdf
Data publikacji:
2014
Wydawca:
Roble
Tematy:
spektrometria rentgenofluorescencyjna
kalibracja prostoliniowa
metoda dodatku wzorca
X-ray fluorescence spectrometry
straight calibration
standard addition method
Źródło:
LAB Laboratoria, Aparatura, Badania; 2014, 19, 1; 6-8
1427-5619
Pojawia się w:
LAB Laboratoria, Aparatura, Badania
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies