Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "X- ray" wg kryterium: Temat


Tytuł:
Review of X-ray detection systems
Autorzy:
Urbański, Paweł
Grzebyk, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/27315700.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Elektryków Polskich
Tematy:
X-ray detection
X-ray radiation
dosimetry
luminescence
Opis:
The article presents an overview and a classification of X-ray detection methods. The main motivation for its preparation was the need to select a suitable and useful method for detecting signals from a currently developed miniature micro-electro-mechanical system (MEMS) X-ray source. The described methods were divided into passive and active ones, among which can be distinguished: chemical, luminescent, thermo-luminescent, gas ionization, semiconductor, and calorimetric methods. The advantages and drawbacks of each method were underlined, as well as their usefulness for the characterisation of the miniature MEMS X-ray source.
Źródło:
Opto-Electronics Review; 2023, 31, 3; art. no. e146554
1230-3402
Pojawia się w:
Opto-Electronics Review
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wideband spectral emission measurements from laser-produced plasma EUV/SXR source based on a double gas puff target
Autorzy:
Arikkatt, Antony Jose
Wachulak, Przemysław
Fiedorowicz, Henryk
Bartnik, Andrzej
Czwartos, Joanna
Powiązania:
https://bibliotekanauki.pl/articles/1849155.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Plasma Spectroscopy
X-ray coherence tomography
soft X-ray
Opis:
We present spectral emission characteristics from laser-plasma EUV/SXR sources produced by irradiation of < 1 J energy laser pulse on eleven different double stream gas puff targets, with most intense electronic transitions identified in the spectral range from 1 nm to 70 nm wavelength which corresponds to photon energy from 18 eV to 1240 eV. The spectra were obtained using grazing incidence and transmission spectrographs from laser-produced plasma emission, formed by the interaction of a laser beam with a double stream gas puff target. Laser pulses with a duration of 4 ns and energy of 650 mJ were used for the experiment. We present the results obtained from three different spectrometers in the wavelength ranges of SXR (1-5.5 nm), SXR/EUV (4-15.5 nm), and EUV (10-70 nm). In this paper, detailed information about the source, gas targets under investigation, the experimental setup, spectral measurements and the results are presented and discussed. Such data may be useful for the identification of adequate spectral emissions from gasses in the EUV and SXR wavelength ranges dedicated to various experiments (i.e. broadband emission for the X-ray coherence tomography XCT) or may be used for verification of magnetohydrodynamic plasma codes.
Źródło:
Metrology and Measurement Systems; 2020, 27, 4; 701-719
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
$K_{β}/K_{α}$ X-Ray Intensity Ratios for Cr, Mn, Fe, and Co Excited by 8.735 keV Energy
Autorzy:
Yılmaz, R.
Powiązania:
https://bibliotekanauki.pl/articles/1398200.pdf
Data publikacji:
2018-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
K X-ray intensity ratios
X-ray fluorescence
cross-sections
Opis:
In this study, the K shell intensity ratios $K_{β}/K_{α}$ have been experimentally determined for the elements Cr, Mn, Fe, and Co. Measurements have been carried out at 8.735 keV excitation energy by using secondary excitation method. K X-rays emitted by samples have been counted by a Si (Li) detector with 160 eV resolutions at 5.9 keV. The measured values were compared with the calculated theoretical values. The obtained values are in good agreement with the calculated values.
Źródło:
Acta Physica Polonica A; 2018, 133, 5; 1227-1230
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiar czasu ekspozycji w miernikach promieniowania rentgenowskiego
Measurement of exposure duration in the X-ray analyser
Autorzy:
Urban, Arkadiusz
Czubla, Albin
Knyziak, Adrian
Powiązania:
https://bibliotekanauki.pl/articles/88863.pdf
Data publikacji:
2020
Wydawca:
Główny Urząd Miar
Tematy:
pomiar czasu ekspozycji
promieniowanie X
aparat rentgenowski
exposure time measurement
X-ray
X-ray machine
X-ray multimeter
Opis:
W artykule opisano problematykę pomiarów przedziałów czasu równych czasowi ekspozycji promieniowania X. Pokazano zależność niepewności pomiaru od metody pomiarowej oraz od sposobu działania źródła promieniowania rentgenowskiego. Przedstawiono wpływ zakresu przedziału czasu mierzonego przez miernik na błąd pomiaru.
The main idea of the article is a description of problems of X-ray exposure time measurement. The content describes two types of X-ray machines. Among the two X-ray machine types, continuous type with shutter is more suitable for long time measurement, and pulse type is better for short time measurements. The differences between mode of operation of different X-ray sources and it’s impact on uncertainty of measurement of exposure time are presented. It also discusses the impact of different resolution settings of device under calibration on uncertainty measurement.
Źródło:
Metrologia i Probiernictwo : biuletyn Głównego Urzędu Miar; 2020, 1 (24); 15-20
2300-8806
Pojawia się w:
Metrologia i Probiernictwo : biuletyn Głównego Urzędu Miar
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
X pinch as a source for X-ray radiography
Autorzy:
Pikuz, S.
Shelkovenko, T.
Romanova, V.
Sinars, D.
Hammer, D.
Bland, S.
Lebedev, S.
Powiązania:
https://bibliotekanauki.pl/articles/147532.pdf
Data publikacji:
2001
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
wire array
X-pinch
X-ray imaging
X-ray radiography
Z-pinch
Opis:
This article describes several applications and methods using the X pinch as a source of X-ray radiation for the radiography of dense plasma objects. These methods, in general, do not use pinholes, and instead take the advantage of the small size (<1 mm, and in some cases <3 mm) and a short X-ray emission duration (<1 ns) of the radiation source produced by an X pinch. Two of these methods, monochromatic and direct point-projection backlighting, are discussed. Experimental images of exploding wires and wire arrays obtained on the BIN, XP, and MAGPIE generators using these techniques are presented. Also included are detailed measurements made on the XP generator of the emission characteristics of X pinches using different wire materials.
Źródło:
Nukleonika; 2001, 46, 1; 21-25
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wzorcowanie funkcji pomiaru czasu ekspozycji w miernikach promieniowania rentgenowskiego
Calibration of exposure duration in the X-ray analyser
Autorzy:
Urban, Arkadiusz
Czubla, Albin
Knyziak, Adrian
Powiązania:
https://bibliotekanauki.pl/articles/268140.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
wzorcowanie miernika promieniowania X
pomiar czasu ekspozycji
promieniowanie X
aparat rentgenowski
calibration
exposure time measurement
X-ray
X-ray machine
X-ray multimeter
Opis:
W artykule opisano problematykę pomiarów przedziałów czasu równych czasowi ekspozycji promieniowania X. Pokazano zależność niepewności pomiaru od metody pomiarowej oraz od sposobu działania źródła promieniowania rentgenowskiego. Przedstawiono wpływ zakresu przedziału czasu mierzonego przez miernik na wielkość błędu.
Main idea of the article is a description of problems of X-ray exposure time measurement. Content describes two types of X-ray machines. Among the two X-ray machine types, continuous type with shutter is more suitable for long time measurement, and pulse type is better for short time measurements. The article discuss differences between mode of operation of different X-ray sources and it’s impact on uncertainty of measurement of exposure time. It also discuss impact of different resolution settings of device under calibration on uncertainty measurement.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 66; 91-94
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Recent measurements of soft X-ray emission from the DPF-1000U facility
Autorzy:
Surała, W.
Sadowski, M. J.
Paduch, M.
Zielinska, E.
Tomaszewski, K.
Powiązania:
https://bibliotekanauki.pl/articles/148171.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
plasma focus
X-ray emission
X-ray images
gas puffing
filaments
hot spots
Opis:
Soft X-ray imaging is a very useful diagnostic technique in plasma-focus (PF) experiments. This paper reports results of four experimental sessions which were carried out at the DPF-1000U plasma-focus facility in 2013 and 2014. Over 200 discharges were performed at various experimental conditions. Measurements were taken using two X-ray pinhole cameras with a line of sight perpendicular to the z-axis, at different azimuthal angles (about 20° and 200°), and looking towards the centre of the PF-pinch column. They were equipped with diaphragms 1000 μm or 200–300 μm in diameter and coated with filters of 500 μm Al foil and 10 μm Be foil, respectively. Data on the neutron emission were collected with silver activation counters. For time-resolved measurements the use was made of four PIN diodes equipped with various fi lters and oriented towards the centre of the PF-column, in the direction perpendicular to the electrode axis. The recorded X-ray images revealed that when the additional gas-puff system is activated during the discharge, the stability of the discharge is improved. The data collected in these experiments confi rmed the appearance of a filamentary fi ne structure in the PF discharges. In the past years the formation of such fi laments was observed in many Z-pinch type experiments. Some of the recorded X-ray images have also revealed the appearance of the so-called hot- -spots, i.e. small plasma regions of a very intense X-ray emission. Such a phenomenon was observed before in many PF experiments, e.g. in the MAJA-PF device, but it has not been investigated so far in a large facility such as the DPF-1000U. The time-resolved measurements provided the evidence of a time lapse between the X-ray emission from plasma regions located at different distance from the anode surface. The formation of distinct ‘hot-spots’ in different instants of the DPF-1000U discharge was also observed.
Źródło:
Nukleonika; 2015, 60, 2; 303-308
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
High speed signal processing for photon counting X-ray detection
Autorzy:
Shinomiya, B.
Koike, A.
Morii, H.
Okunoyama, T.
Neo, Y.
Mimura, H.
Aoki, T.
Powiązania:
https://bibliotekanauki.pl/articles/385292.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
X-ray
CdTe
photon counting
Opis:
Recently practical X-ray measurement systems are demanded energy distinction function. Photon-counting CdTe semiconductor detectors have a high energy resolution in a low count rate condition at room temperature. However, the energy resolution is decreased by pile-up phenomenon in a high count rate condition. In conventional signal processing, processing time estimated X-ray photon energy from the pulse waveform is about tens of microseconds. This time is depended on the pulse decay time. This paper purposes to maintain the high energy resolution by changing the signal-processing algorithm, which derived the pulse rise height of the output waveform from the CdTe detector in a high count rate condition. As a result, the pulse rise time required to estimate the pulse rise height was short about 100 ns at incident X-ray energy 60 keV. As the result of energy spectrum by using this data, the FWHM of about 11keV (at 60 keV) when the count rate of 500 kcps. This result shows the possibility that the photon counting sensor has application for the high count rate imaging without decrease of the high energy resolution.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2009, 3, 4; 143-146
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary study on X-ray source from Plasma Focus device for fast radiography
Autorzy:
Da Re, A.
Mezzetti, F.
Tartari, A.
Verri, G.
Rapezzi, L.
Gribkov, V. A.
Powiązania:
https://bibliotekanauki.pl/articles/147243.pdf
Data publikacji:
2001
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
plasma focus
X-ray sources
Opis:
Plasma derived flash X-ray sources may find potential applications in medicine and industry. Notwithstanding, as is the case of Plasma Focus (PF) devices, their characterisation in term of photon energy, temporal and spatial beam stability is far to be considered satisfactory. In this work, a radiographic approach, which avoids the effects caused by the intrinsic instability of the pinch output of a PF machine, is proposed and an attenuation curve can be attained even in presence of Xray emission instability. Using two radiographic films for each shot exposition symmetrically positioned and collimated to the pinch region the mean energy of the photons in the X-ray beam are evaluated. The X-ray emission symmetry from the pinch region was then utilised to control the validity of the proposed methodology.
Źródło:
Nukleonika; 2001, 46, suppl. 1; 123-125
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
X-ray techniques in the investigation of a Gothic sculpture : the risen Christ
Autorzy:
Mikołajska, A.
Walczak, M.
Kaszowska, Z.
Urbańczyk-Zawadzka, M.
Powiązania:
https://bibliotekanauki.pl/articles/146866.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
cultural heritage
X-ray image
X-ray dual source computed tomography (DSCT)
scanning electron microscopy energy dispersed X-ray spectroscopy (SEM-EDX)
Opis:
For over a century, X-ray radiation has played an important role in the area of the conservation and restoration of cultural heritage objects. X-ray techniques are amongst the most fundamental and helpful methods used in the investigation of art works. This paper reviews the application of traditional radiography, X-ray dual source computed tomography (DSCT) and scanning electron microscopy combined with energy dispersed X-ray spectroscopy (SEM-EDX) to the investigation of a wooden, Gothic sculpture, The risen Christ. Thanks to the properties of X-ray radiation (different absorption by various materials) first two methods allow the assessment of the preservation state and the observation of the internal structure of an object in 3-D. While SEM-EDX analysis permits the elemental analysis of the polychrome layers. As a result 2-D and 3-D images, permitting the full volume inspection of an object, were taken in a totally non-destructive way. The morphological and physical information about the inner structure of the investigated wooden sculpture was obtained, revealing changes related to previous restorations, as well as ageing effects. Employing the SEM-EDX, painting materials (pigments and filers), were identified. Gained data is essential for restorers to understand the whole structure of the studied object and to decide which further investigation and restoration steps have to be undertaken.
Źródło:
Nukleonika; 2012, 57, 4; 627-631
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dense Plasma Focus as a powerful source of monochromatic X-ray radiation
Autorzy:
Dubrovsky, A.
Gribkov, V.
Ivanov, Y.
Karpiński, L.
Orlova, M.
Powiązania:
https://bibliotekanauki.pl/articles/147444.pdf
Data publikacji:
2006
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
dense plasma focus (DPF)
X-ray generation
X-ray dosimetry
exposure dose
absorbed dose
Opis:
A review of some experimental results obtained using the dense plasma focus (DPF) device PF-1000 is presented. The copper Ka1,2 radiation line generated by DPF in the case of device anode made of copper was the main object of this study. The predominance of this characteristic radiation over other kinds of radiation in the DPF X-ray spectrum is shown. A brief description of a new DPF 6.0 device as well as a radioenzymology experiment carried out within this device is presented.
Źródło:
Nukleonika; 2006, 51, 1; 21-28
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelling of the soft X-ray tungsten spectra expected to be registered by GEM detection system for WEST
Autorzy:
Syrocki, Ł.
Szymańska, E.
Słabkowska, K.
Polasik, M.
Pestka, G.
Powiązania:
https://bibliotekanauki.pl/articles/971490.pdf
Data publikacji:
2016
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
X-ray spectra
tokamak
tungsten L, M, N, X-ray lines
GEM detection system
Opis:
In the future International Thermonuclear Experimental Reactor (ITER), the interaction between the plasma and the tungsten chosen as the plasma-facing wall material imposes that the hot central plasma loses energy by X-ray emission from tungsten ions. On the other hand, the registered X-ray spectra provide alternative diagnostics of the plasma itself. Highly ionized tungsten emits extremely complex X-ray spectra that can be understood only after exhaustive theoretical studies. The detailed analyses will be useful for proper interpretation of soft X-ray plasma radiation expected to be registered on ITER-like machines, that is, Tungsten (W) Environment in Steady-state Tokamak (WEST). The simulations of the soft X-ray spectra structures for tungsten ions have been performed using the flexible atomic code (FAC) package within the framework of collisional-radiative (CR) model approach for electron temperatures and densities relevant to WEST tokamak.
Źródło:
Nukleonika; 2016, 61, 4; 433-436
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Synthesis and Characterization of Co-Cs-Nd-Sr-Doped Perovskite-Rutile-Type Structure
Autorzy:
Smolinski, T.
Zhao, L.
Rogowski, M.
Wawszczak, D.
Olczak, T.
Brykala, M.
Powiązania:
https://bibliotekanauki.pl/articles/355628.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Synroc
X-ray diffraction
Rutherford backscattering
particle induced X-ray emission
Roentgen computed microtomography
Opis:
The perovskite type matrix is considered as solidification material for high-level radioactive waste. In this work the perovskite-rutile-type matrix doped by Co, Cs, Nd and Sr which simulate nuclear waste was prepared by sol-gel route. The material was characterized by several methods such as: X-ray diffraction, energy dispersive X-ray spectrometer, and particle induced X-ray emission combined with Rutherford backscattering spectrometry. The analyzes confirmed chemical composition Co-Cs-Nd-Sr-doped perovskite-rutile-type structure. A virtual model of the pellet`s structure was created non-destructively by Roentgen computed micro-tomography. The leaching tests confirmed high chemical resistance of the matrix.
Źródło:
Archives of Metallurgy and Materials; 2020, 65, 4; 1417-1423
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
X-ray tube with needle-like anode
Autorzy:
Słapa, M.
Straś, W.
Traczyk, M.
Dora, J.
Snopek, M.
Gutowski, R.
Drabik, W.
Powiązania:
https://bibliotekanauki.pl/articles/147038.pdf
Data publikacji:
2002
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
brachytherapy
photon needle
X-ray tube
Opis:
An X-ray tube with a needle-like anode (NAXT) built in our Laboratory, its design and basic operating parameters are presented. The process of electron beam forming and influence of external and internal magnetic fields is discussed. The tube properties essential from the point of view of its application in X-ray generators as well as disadvantageous thermal effects caused by flow of heat generated in the tube target to irradiated objects are discussed. The tube is almost a point-like source of X radiation emitted into 4đ geometry; the dose rates are on the order of 1 Gy/min at the distance of 10 mm from the anode cap. Preliminary tests show the tube may be useful in brachytherapy of cancer tumors of diameter up to 30 mm. The tube may also be an interesting device in widely understood field of irradiation techniques.
Źródło:
Nukleonika; 2002, 47, 3; 101-105
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multichannel calorimeters for measurement of flows of X-ray radiation in the range from 10 up to 200 keV
Autorzy:
Vinogradov, V. P.
Powiązania:
https://bibliotekanauki.pl/articles/148228.pdf
Data publikacji:
2001
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
calorimeter
hard X-ray
plasma focus
Opis:
An 8-channel calorimeter was developed and applied to the Plasma focus facility (PF) with flat geometry of electrodes (Filippov type) for the measurements of a hard X-ray (HXR) radiation yield and its spectral distribution. The calorimeter measures the time-integrated HXR flux for one shot of the PF facility without any additional calibrations. The sensitivity ~10–4 J/cm2 was achieved.
Źródło:
Nukleonika; 2001, 46, suppl. 1; 99-101
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies