Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "UTCI" wg kryterium: Temat


Tytuł:
Winter UTCI variability in Poland in the 21st century
Autorzy:
Wereski, Sylwester
Krzyżewska, Agnieszka
Dobek, Mateusz
Powiązania:
https://bibliotekanauki.pl/articles/946933.pdf
Data publikacji:
2020
Wydawca:
Uniwersytet Warszawski. Wydział Geografii i Studiów Regionalnych
Tematy:
UTCI
Universal Thermal Climate Index
biothermal conditions
cold stress
winter season
Polska
Opis:
The study analyses spatial and temporal variability of the UTCI index during winter seasons in Poland in the 21st century. The most frequent UTCI thermal stress category was moderate cold stress with a frequency varying from 45.8% in Łeba (Coastal region) to 66.1% in Zielona Góra (Central region). In mountain areas, this class was less frequent (7.3-12.3%). The second most frequent class was strong cold stress with values from 11.1% in Zakopane (Carpathian region) to 43.4% in Suwałki (North-East region). In mountain areas, very strong cold stress and extreme cold stress occurred frequently (25.0-35.5% and 17.7-52.0%, respectively). Few cases of extreme cold stress were observed on other Polish stations. Thermoneutral zone was not recorded in the mountain area, although on other Polish stations its frequency ranged from 0.1% in Chojnice, Suwałki and Białystok located in northern part of Poland to 4.3% in Zakopane (Carpathian region).
Źródło:
Miscellanea Geographica. Regional Studies on Development; 2020, 24, 3; 128-137
0867-6046
2084-6118
Pojawia się w:
Miscellanea Geographica. Regional Studies on Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of regional baric systems on the occurrence of bioclimatic conditions in Poland
Autorzy:
Tomczyk, Arkadiusz M.
Bednorz, Ewa
Szyga-Pluta, Katarzyna
Owczarek, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/52496095.pdf
Data publikacji:
2023
Wydawca:
Uniwersytet im. Adama Mickiewicza w Poznaniu
Tematy:
bioclimatic conditions
UTCI
atmospheric circulation
Polska
Opis:
The present study concerns the determination of the characteristics of bioclimatic conditions, as well as the synoptic situations related to the occurrence of thermal stress conditions, in Poland. The study was based on daily data obtained from the Institute of Meteorology and Water Management – National Research Institute from the period 1966–2020 for 37 synoptic stations in Poland. Based on the obtained data, values of the Universal Thermal Climate Index (UTCI) were calculated. The occurrence of heat stress increases from the north to the south, corresponding with the variability of influx of solar radiation, and is modified by factors at a smaller spatial scale. The results of this paper evidently point to the cooling effect of the waters of the Baltic Sea. In circulation conditions favouring strong and very strong heat stress, e.g. in two of the designated circulation types (T1 and T2), the occurrence of an expansive high-pressure ridge in the Atlantic-European area is typical, stretching from the region of the Azores High towards the north-east, with a secondary high developed within its boundaries. In the third of the designated circulation types (T3), the high-pressure area extends from the Azores eastwards, reaching the Black Sea. Each of the three circulation patterns associated with the unfavourable biometeorological conditions of very strong and extreme cold stress in Poland is characterised by strong pressure centres formed in the Euroatlantic region, triggering the airflow from the northern (T4) or eastern (T5, T6) sector.
Źródło:
Quaestiones Geographicae; 2023, 42, 1; 161-177
0137-477X
2081-6383
Pojawia się w:
Quaestiones Geographicae
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Warunki meteorologiczne i biometeorologiczne południowo-zachodniego Svalbardu w 2010 roku
Meteorological and biometeorological conditions of South-West Svalbard in 2010
Autorzy:
Sikora, S.
Budzik, T.
Migała, K.
Puczko, D.
Powiązania:
https://bibliotekanauki.pl/articles/260997.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Klimatologów Polskich
Tematy:
warunki meteorologiczne
bioklimat
automatyczne stacje meteorologiczne
Spitsbergen
UTCI
meteorological conditions
bioclimate
automatic weather stations
Opis:
Opracowanie nawiązuje do prezentowanych w latach ubiegłych artykułów, których celem jest przedstawienie warunków meteorologicznych i biometeorologicznych jakie występowały w południowej części Ziemi Wedela Jarlsberga, SW Svalbard. Dane, na podstawie których tego dokonano, zostały zgromadzone w roku 2010 w następujących punktach: na terasie morskiej (PSP), pobliskim szczycie górskim (FUG) i na Lodowcu Hansa: w strefie akumulacji (HT9) i poniżej linii równowagi (HT4). Zgromadzone dane meteorologiczne są w pełni oryginalne i nigdzie dotychczas niepublikowane. Na ich podstawie przeprowadzono analizę warunków meteorologicznych i biometeorologicznych jakie występowały w 2010 roku. Po raz pierwszy autorzy zastosowali wskaźnik UTCI (Universal Thermal Climate Index) do oceny warunków klimatu odczuwalnego tego obszaru.
Results of meteorological and biometeorological investigation in polar region are the aim of presented paper. Investigated area is located in SW part of Spitsbergen (surrounding of Hornsund fjord) where operate the Polish Polar Station. Data used in the paper were collected in 2010 by an automatic weather stations (measured parameters: air temperature and relative humidity, wind speed and direction, global and reflected solar radiation) located: at the Polish Polar Station (PSP: 77.00159 N 15.54131 E, 10 m a.s.l.), middle part of Hans Glacier below equilibrium line (HT4: 77.04738 N 15.63275 E, 180 m a.s.l.) and accumulation's zone of Hans Glacier (HT9: 77.11656 N 15.48781 E, 430 m a.s.l.). Only a peak of Fugleberget (FUG 77.02008 N 15.56587 E, 568 m a.s.l.) were equipped with air temperature and relative humidity logger HOBO Pro series. Biometeorological conditions of investigated area were evaluated by Wind Chill Index, analysis of man-environment heat exchange fluxes and Universal Thermal Climate Index (UTCI; new developed tool for biometeorological investigation). Above indices identified accumulation zone as a place with specific biometeorological condition: average values of UTCI and WCI indicate mildest biothermal environment. However, in this area highest biometeorological stimuli are observed. Weather condition of SW Spitsbergen is strongly modified by atmospheric circulation. In 2010 air masses flowed from north sector were observed (36% days) twice often than from south.
Źródło:
Problemy Klimatologii Polarnej; 2011, 21; 213-228
1234-0715
Pojawia się w:
Problemy Klimatologii Polarnej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bioklimat wybranych miast pasa Pobrzeży Południowobałtyckich na podstawie uniwersalnego wskaźnika obciążenia cieplnego
Bioclimate of the chosen cities in the Polish Baltic Coast based on Universal Thermal Climate Index
Autorzy:
Półrolniczak, Marek
Szyga-Pluta, Katarzyna
Kolendowicz, Leszek
Powiązania:
https://bibliotekanauki.pl/articles/578324.pdf
Data publikacji:
2016
Wydawca:
Łódzkie Towarzystwo Naukowe
Tematy:
bioklimat
UTCI
reanalizy NCEP/NCAR
Polska
obszar nadmorski
bioclimate
UTCI index
NCEP/NCAR reanalyses
Polska
coastline
Opis:
W niniejszej pracy, na podstawie wskaźnika UTCI (Universal Thermal Climate Index), analizowano warunki bioklimatyczne wybranych miast w pasie Pobrzeży Południowobałtyckich. Dodatkowo, na podstawie danych z reanaliz meteorologicznych NCEP/NCAR dotyczących ciśnienia atmosferycznego na poziomie morza oraz wysokości geopotencjalnej 500 hPa, ustalono charakterystyczne typy sytuacji synoptycznych, które odpowiadają za wystąpienie warunków z ekstremalnie gorącym i zimnym obciążeniem organizmu człowieka. Analiza częstości dni według kategorii UTCI wykazała, że w badanych miastach w ciągu roku najczęściej pojawiają się warunki z brakiem obciążeń cieplnych organizmu człowieka, natomiast spośród dni z warunkami obciążającymi przeważają te ze stresem zimna. Badanie trendów wieloletnich wykazało statystycznie istotny wzrost wartości wskaźnika UTCI w roku i sezonach. Analiza trendów dni wg kategorii wskaźnika UTCI wykazała wzrost liczby dni z warunkami stresu ciepła i stresu zimna w Świnoujściu i Łebie oraz stresu ciepła w Kołobrzegu i zimna w Helu.
The paper addresses the bioclimatic conditions of selected towns of the southern part of the Polish Baltic Coast on the basis of the UTCI index. Moreover, the authors, by using observational data from coastline stations, as well as reanalysis data of the mean sea level pressure and the 500 hPa geopotential height from the NCEP/NCAR, attempt to explain which synoptic situations are conductive to the occurrence of days with very strong and extreme cold or heat stress. The research proved that the lack of thermal stress occurs most frequently. Among days with aggravating conditions days with the cold stress category appear most frequently. The study of long-term trends showed a statistically significant increase in the value of the UTCI index in the year and seasons. An analysis of days by the UTCI index category trends showed an increase in the number of days with conditions of both heat and cold stress in Świnoujście and Łeba, heat stress in Kołobrzeg and cold stress in Hel.
Źródło:
Acta Geographica Lodziensia; 2016, 104; 147-161
0065-1249
Pojawia się w:
Acta Geographica Lodziensia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
UTCI field measurements in an urban park in Florence (Italy)
Autorzy:
Petralli, Martina
Massetti, Luciano
Pearlmutter, David
Brandani, Giada
Messeri, Alessandro
Orlandini, Simone
Powiązania:
https://bibliotekanauki.pl/articles/946947.pdf
Data publikacji:
2020
Wydawca:
Uniwersytet Warszawski. Wydział Geografii i Studiów Regionalnych
Tematy:
Thermal comfort
urban park
UTCI
biometeorology
tree shade
Opis:
The aim of this study is to evaluate human thermal comfort in different green area settings in the city of Florence by using the Universal Thermal Climate Index (UTCI). Field measurements of air temperature, solar radiation, relative humidity, wind speed and black globe thermometer were collected during hot summer days in various parts of Cascine Park, the biggest urban park in Florence (Italy). UTCI was evaluated over different surfaces (asphalt, gravel and grass) completely exposed to the sun or shaded by a large lime tree (Tilia × europaea). The results showed strong differences in UTCI values depending on the exposure to tree shade, while no significant difference was found among ground-cover materials when all surfaces were equally exposed to solar radiation. Future studies are needed to investigate the microclimatic effects of different tree species on UTCI.
Źródło:
Miscellanea Geographica. Regional Studies on Development; 2020, 24, 3; 111-117
0867-6046
2084-6118
Pojawia się w:
Miscellanea Geographica. Regional Studies on Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of atmospheric circulation on the occurrence of very strong and extreme cold stress in Poland
Autorzy:
Owczarek, Małgorzata
Tomczyk, Arkadiusz M.
Powiązania:
https://bibliotekanauki.pl/articles/15804893.pdf
Data publikacji:
2022
Wydawca:
Uniwersytet im. Adama Mickiewicza w Poznaniu
Tematy:
bioclimatology
UTCI
atmospheric circulation
cold stress
winter
Polska
Opis:
The primary objective of the study was the determination of the spatial and multiannual variability of occurrence of days with very strong and extreme cold stress in Poland according to the Universal Thermal Climate Index (UTCI), as well as determination of baric conditions favouring their occurrence. The study was based on data from the years 1966/67 to 2018/19 from the Institute of Meteorology and Water Management – National Research Institute and National Centre for Environmental Prediction/National Centre for Atmospheric Research (NCEP/NCAR). The research showed a statistically significant decrease in the number of days with very strong and extreme cold stress on half of the analysed stations, and a slight tendency or no changes on the remaining stations. The occurrence of days with extreme cold stress in Poland, as revealed by the analysis was primarily related to the presence of high-pressure systems blocking zonal circulation. The study resulted in the designation of three circulation types, i.e. two types related to anticyclonic systems and one cyclonic type.
Źródło:
Quaestiones Geographicae; 2022, 41, 3; 111-126
0137-477X
2081-6383
Pojawia się w:
Quaestiones Geographicae
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Intensity of heat stress in 2015 and 2018 summer seasons in the region of the Lower Silesia (Poland)
Autorzy:
Miszuk, Bartłomiej
Powiązania:
https://bibliotekanauki.pl/articles/946945.pdf
Data publikacji:
2020
Wydawca:
Uniwersytet Warszawski. Wydział Geografii i Studiów Regionalnych
Tematy:
Bioclimate
heat stress
UTCI
Lower Silesia
south-west Poland
Opis:
The main goal of this paper was to assess the intensity of heat stress in Lower Silesia, Poland, during selected weather events characterized by high air temperatures. The complex impact of weather on the thermal load of the human organism is presented using the Universal Thermal Climate Index (UTCI). The analysis was carried out for the 2015 and 2018 summer seasons and compared with the multiannual period of 1971–2018. It was based on meteorological data from the IMGW-PIB stations of Wrocław, Jelenia Góra and Śnieżka. In order to examine how heat conditions affect UTCI in different geographical regions, stations located at different altitudes and representing the lowlands, the lower mountain zone and the summit zone of the Sudetes Mountains were considered. The research showed that during the most extreme thermal events, UTCI values in the lowlands and the lower mountain zones can be among the highest heat stress classes. In the summit zone, the maximum UTCI values are usually classed as ‘no thermal stress’.
Źródło:
Miscellanea Geographica. Regional Studies on Development; 2020, 24, 3; 138-146
0867-6046
2084-6118
Pojawia się w:
Miscellanea Geographica. Regional Studies on Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Warunki meteorologiczne w Lublinie podczas wyjątkowo uciążliwej fali upałów z sierpnia 2015 r.
The Meteorological Conditions During Particularly Severe Heatwave in Lublin in August 2015
Autorzy:
Krzyżewska, A.
Bartoszek, K.
Wereski, S.
Powiązania:
https://bibliotekanauki.pl/articles/163814.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwa Geofizyczne
Tematy:
fale upałów
cyrkulacja
Lublin
UTCI
heatwaves
circulation
Opis:
W pracy przeanalizowano warunki meteorologiczne, biometeorologiczne i cyrkulacyjne podczas niezwykle długiej i uciążliwej fali upałów, jaka wystąpiła w Lublinie w dniach od 3 do 13 sierpnia 2015. Dane meteorologiczne pochodziły z Obserwatorium Meteorologicznego UMCS. Do opracowania wskaźnika UTCI wykorzystano dane godzinowe z depesz SYNOP z bazy www.ogimet.com ze stacji IMGW Lublin-Radawiec, a obliczenia wykonano w programie BioKlima 2.6. Do konstrukcji map określających warunki cyrkulacyjne wykorzystano dane pochodzące z reanalizy NCEP/NCAR. Uzyskane wyniki porównano ze średnimi wieloletnimi z lat 1952-2010. Za falę upałów przyjęto co najmniej 3 kolejne dni z maksymalną temperaturą powietrza przekraczającą 30°C. Za noc tropikalną przyjęto noc z temperaturą minimalną większą od 20°C, za dzień parny zaś dzień z ciśnieniem pary wodnej ≥18,8 hPa w przynajmniej jednym terminie obserwacyjnym w ciągu doby (kryterium Scharlau’a). Fala upałów, która trwała od 3 do 13 sierpnia 2015 (11 dni), była najdłuższą dotychczas zanotowaną w Lublinie, ze szczególnie wysoką temperaturą maksymalną. Fala ta objęła serię dni parnych i nocy tropikalnych, co uczyniło ją jedną z najbardziej uciążliwych fal upałów w Lublinie. Wystąpienie tej fali upałów było uwarunkowane długotrwałym zaleganiem stabilnego układu wysokiego ciśnienia z centrum nad zachodnią Rosją oraz występowaniem słabogradientowego pola barycznego nad Europą Zachodnią i Środkową. Sprzyjało to adwekcji nad Lubelszczyznę bardzo ciepłych mas powietrza ze wschodu i południo-wschodu (zarówno w dolnej, jak i środkowej troposferze). Od 7 do 12 sierpnia wystąpiły w Lublinie warunki „bardzo silnego stresu ciepła” (według wskaźnika UTCI). Najdłużej warunki „bardzo silnego stresu ciepła” utrzymywały się w dniach 7-8 sierpnia podczas 5 terminów obserwacji (w pozostałych tylko między godziną 12.00 a 14.00).
In this study the circulation, meteorological and biometeorological conditions were analyzed during an extremely long and severe heat wave in Lublin from 3 to 13 August 2015. The meteorological data was obtained from the Meteorological Observatory UMCS. For calculation the UTCI index we used hourly data from SYNOP from the database www.ogimet.com for IMGW Lublin-Radawiec weather station. The calculations were made in the program BioKlima 2.6. To construct the maps defining the circulation conditions, data from the reanalysis NCEP/NCAR was utilized. The results were compared to the averages of the years 1952-2010. The heatwave was defined as at least 3 consecutive days of maximum daily air temperatures exceeding 30°C. The night tropical night was defined as night with minimum temperature greater than 20°C, and sultry days were defined ad days with water vapor pressure ≥18,8 hPa during at least one observation each day, according to the Scharlau'a criterion. The heatwave which lasted from 3 to 13 August 2015 (11 days) was the longest so far noted in Lublin, with particularly high values of maximum temperature. Heatwave was accompanied by a series of sultry days and tropical nights, making it also one of the most severe heatwaves in Lublin. The occurrence of this heatwave was caused by long-term stable persistence of the high pressure center over western Russia, and the incidence of low barometric gradient field over Western Europe and Central Europe. This favored advection over Lublin Region very warm air masses from the east and south-east (both in the lower and middle troposphere). From 7 to August 12 in Lublin there were observed conditions of ‘very strong heat stress’ (according to the UTCI index) during which it is recommended to use the air-conditioned rooms or shady areas, fluid replacement and limiting exercise. For the longest time the conditions of ‘very strong heat stress’ was noted on 7-8 August and were present during the five terms of observation; in the remaining days such situations occurred between 12.00 and 14.00.
Źródło:
Przegląd Geofizyczny; 2016, 3-4; 239-249
0033-2135
Pojawia się w:
Przegląd Geofizyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal stress comfort in a contemporary housing district in a moderate climate zone, Lublin as a case study
Autorzy:
Kozak, Małgorzata
Krupa, Karol
Hołownia, Damian
Powiązania:
https://bibliotekanauki.pl/articles/27314446.pdf
Data publikacji:
2023
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
climate change
housing estates
UTCI
ENVI-met
Opis:
Urban climate and its impact on the thermal comfort of residents are significant aspects in urban planning and the design of housing estates. The aim of this article is to investigate the temperature perception among residents in a contemporary residential area in Lublin during the hottest day, utilising an advanced computer simulation tool – the ENVI-met programme. A modern, densely built housing estate with no significant greenery was selected as a case study. General meteorological and spatial data were used for calibrating the housing estate model within the software. The housing estate model within the programme was calibrated using publicly available meteorological and spatial data, and computer simulations were conducted for Lublin's hottest day on 22 July 2022. Based on these simulations, the Universal Thermal Climate Index (UTCI) was calculated. The research results indicate that people experience moderate thermal stress in unshaded areas only at 4:00 pm, while in sunny locations, they experience strong to very strong heat stress throughout the day. This article underscores the importance of computer simulations in analysing the urban microclimate and provides insights into tools that can be used in urban planning and housing estate design processes, with the aim of creating more comfortable and environmentally friendly urban environments.
Źródło:
Budownictwo i Architektura; 2023, 22, 4; 97--111
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bioclimatic conditions of Paris, Rome and Budapest on the basis of the universal thermal climate index
Autorzy:
Idzikowska, Danuta
Powiązania:
https://bibliotekanauki.pl/articles/2034134.pdf
Data publikacji:
2010-06-01
Wydawca:
Uniwersytet Warszawski. Wydział Geografii i Studiów Regionalnych
Tematy:
bioclimate
UTCI
Paris
Rome
Budapest
Opis:
The aim of this study was to examine the main features of the bioclimatic conditions of three European cities using a new Universal Thermal Climate Index. Daily values of meteorological variables for 12 UTC for the cities for 1990-2001 were used in the study. Using the frequency of UTCI and one-way Anova, the results showed that in all the three cities “no thermal stress” dominated throughout the year. “Extreme” values of heat as well as “cold stress” were observed but in none of the cities “extreme cold stress” occurred. The values of UTCI differed for all the three cities in each studied year. The cities differed from each other in each month during the whole year with the exception of spring - March and April.
Źródło:
Miscellanea Geographica. Regional Studies on Development; 2010, 14; 103-109
0867-6046
2084-6118
Pojawia się w:
Miscellanea Geographica. Regional Studies on Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bioclimatic conditions of Lublin based on the Universal Thermal Climate Index (UTCI)
Autorzy:
Dobek, Mateusz
Wereski, Sylwester
Krzyżewska, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/946928.pdf
Data publikacji:
2020
Wydawca:
Uniwersytet Warszawski. Wydział Geografii i Studiów Regionalnych
Tematy:
Urban bioclimatology
bioclimatology
UTCI
Lublin
Opis:
The objective of this paper is to describe bioclimatic conditions in Lublin and Radawiec in the period 1976–2015 using the UTCI index. The paper shows that in Lublin and Radawiec, the most frequent biometeorological conditions caused no heat stress and were neutral for the human organism. At the analysed stations, biometeorological conditions causing cold stress occurred more frequently than those causing heat stress. Biometeorological conditions in the analysed period were characterised by high year-to-year variability. We observed that in recent years there was an increase in frequency of conditions favouring heat stress and a decrease in conditions favouring cold stress.
Źródło:
Miscellanea Geographica. Regional Studies on Development; 2020, 24, 3; 118-127
0867-6046
2084-6118
Pojawia się w:
Miscellanea Geographica. Regional Studies on Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wstępna ocena potencjału bioklimatycznego uzdrowiska Nałęczów w półroczu ciepłym
Autorzy:
Dobek, Mateusz
Krzyżewska, Agnieszka
Wereski, Sylwester
Powiązania:
https://bibliotekanauki.pl/articles/763218.pdf
Data publikacji:
2017
Wydawca:
Uniwersytet Marii Curie-Skłodowskiej. Wydawnictwo Uniwersytetu Marii Curie-Skłodowskiej
Tematy:
spa-town Nałęczów, bioclimate, UTCI, climate stimuli
Uzdrowisko Nałęczów, bioklimat, UTCI, bodźcowość klimatu
Opis:
The aim of the study is to present the preliminary analysis of bioclimate in the spa-town Nałęczów with selected bioclimatic characteristics, including thermal stimuli, inter-daily changes in temperature, heat waves, sultry days and thermal and humidity conditions defined by Humidex. Meteorological data used in the work is derived from the automated station Davis and HOBO sensors, located in the Municipal Sewage Treatment Plant in Nałęczów. The study employs the data from the warm half of the year (April – September) 2014. Nałęczów is warmer and more humid than Lublin. The analyzed period in Nałęczów was characterized by a relatively high incidence of acute and strongly felt thermal stimuli (June and July), which adversely affect the health and well-being of inhabitants and visitors. At the turn of July and August (July 31st – August 4th) the 5-day heat wave occurred. Those were highly unfavourable conditions for patients with cardiac diseases. Sultry days appeared as early as in May, while the maximum was in July. The preliminary study of the bioclimate of Nałęczów based on Humidex showed that the observation period was dominated by conditions favourable for patients (“comfort” conditions). The most unfavourable conditions were observed at the beginning of August.
Celem pracy jest wstępna analiza bioklimatu Nałęczowa za pomocą wybranych charakterystyk bioklimatycznych, m.in. bodźcowości termicznej, międzydobowych zmian temperatury i ciśnienia, fal upałów, dni parnych i wskaźnika UTCI. Dane meteorologiczne wykorzystane w pracy pochodzą ze stacji automatycznej Davis oraz czujników HOBO, zlokalizowanych na terenie Miejskiej Oczyszczalni Ścieków w Nałęczowie. W pracy wykorzystano dane z półrocza ciepłego (kwiecień – wrzesień 2014 r.). Dotyczą one: temperatury i wilgotności względnej powietrza, kierunku i prędkości wiatru oraz całkowitego promieniowania słonecznego. Półrocze ciepłe (kwiecień – wrzesień 2014 r.) w Nałęczowie charakteryzowało się stosunkowo dużą częstością występowania ostrych i silnie odczuwalnych bodźców termicznych (lipiec, czerwiec), które niekorzystnie wpływają na zdrowie i samopoczucie człowieka. Na przełomie lipca i sierpnia (31.VII-04.VIII) pojawiła się 5-dniowa fala upałów, osiągając w czasie kulminacji temperaturę 33,7°C. Liczba dni upalnych wyniosła 10, przy średniej dla wielolecia 1971-1989 wynoszącej 4 dni. Były to warunki wysoce niekorzystne dla kuracjuszy ze schorzeniami kardiologicznymi (które są głównym profilem leczniczym Nałęczowa).  Dni parne pojawiły się już w maju, natomiast ich maksimum przypada na lipiec. Międzydobowe zmiany ciśnienia, wpływające niekorzystnie na człowieka, w Nałęczowie pojawiały się sporadycznie, co sprzyja klimatoterapii. Wstępne badania bioklimatu Nałęczowa bazujące na wskaźniku UTCI wykazały, iż w okresie obserwacyjnym dominowały warunki korzystne dla kuracjuszy („brak obciążeń cieplnych” i „umiarkowany stres ciepła”). 
Źródło:
Annales Universitatis Mariae Curie-Sklodowska, sectio B – Geographia, Geologia, Mineralogia et Petrographia; 2017, 72, 1
0137-1983
Pojawia się w:
Annales Universitatis Mariae Curie-Sklodowska, sectio B – Geographia, Geologia, Mineralogia et Petrographia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybrane zagadnienia z bioklimatu Lublina
Autorzy:
Dobek, Mateusz
Krzyżewska, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/763295.pdf
Data publikacji:
2015
Wydawca:
Uniwersytet Marii Curie-Skłodowskiej. Wydawnictwo Uniwersytetu Marii Curie-Skłodowskiej
Tematy:
urban bioclimate
cooling value (H)
Universal Thermal Climate Index (UTCI)
Lublin
bioklimat miasta
wielkość ochładzająca powietrza
UTCI
Opis:
The aim of this paper is to elaborate the bioclimatic conditions in Lublin in the years 1952–2010. For this purpose the cooling air power and the latest indicator of the thermal load of the human body Universal Thermal Climate Index (UTCI) were studied.According to bioclimatic index air cooling power (H) conditions considered as comfort conditions (mild and pleasantly cool) occurred with total frequency of 41%. In the years 1952–2010 there was a slight decrease of percentage of cold conditions (unbearably cold and windy and cold). In the years 1952–2010 thermoneutral zone was the most often occurring conditions from UTCI scale (39% of days). Despite the year-to-year differences during long-term course there are no significant changes. The biggest changes are visible at the beginning of the 70’s, when the share of conditions connected to the heat stress increased and the share of classes connected with cold stress decreased.
Praca ma na celu opracowanie warunków bioklimatycznych Lublina w latach 1951-2010. W tym celu wykorzystano wielkość ochładzającą powietrza, a także najnowszy wskaźnik obciążeń cieplnych organizmu człowieka Universal Thermal Climate Index (UTCI).Według wskaźnika bioklimatycznego wielkość ochładzająca powietrza (H) warunki uznawane za komfortowe, czyli „łagodnie” i „przyjemnie chłodno”, pojawiały się łącznie z częstością 41%. W latach 1951-2010 nastąpił niewielki spadek udziału procentowego odczuć chłodu („nieznośnie zimno i wietrznie”, „bardzo zimno” i „zimno”).W latach 1951-2010 najczęściej występujące wielkości UTCI należały do klasy „brak obciążeń cieplnych” (39% dni). Pomimo różnic częstości z roku na rok, w przebiegu wieloletnim nie obserwuje się istotnych tendencji zmian. Największe zmiany widoczne są na początku lat 70-tych, kiedy zwiększył się udział odczuć związanych ze stresem ciepła, natomiast klasy odczuć zimna pojawiały się rzadziej.
Źródło:
Annales Universitatis Mariae Curie-Sklodowska, sectio B – Geographia, Geologia, Mineralogia et Petrographia; 2015, 70, 2
0137-1983
Pojawia się w:
Annales Universitatis Mariae Curie-Sklodowska, sectio B – Geographia, Geologia, Mineralogia et Petrographia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zróżnicowanie przestrzenne wskaźnika UTCI w Lublinie w określonych scenariuszach pogodowych
Autorzy:
Dobek, Mateusz
Demczuk, Piotr
Nowosad, Marek
Powiązania:
https://bibliotekanauki.pl/articles/763190.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Marii Curie-Skłodowskiej. Wydawnictwo Uniwersytetu Marii Curie-Skłodowskiej
Tematy:
urban bioclimate
sensible climate UTCI urban planning
Lublin
bioklimat miasta
odczuwalny UTCI
planowanie przestrzenne
Opis:
There is no abstract available for this language
Lublin jest dla bio- i topoklimatologii cennym obszarem badawczym, gdyż ze względu na urozmaiconą rzeźbę terenu oraz obecność licznych rozcięć wąwozowych wykorzystywanychprzez człowieka charakteryzuje się dużym zróżnicowaniem mikroklimatu. W pracy przedstawiono zróżnicowanie przestrzenne warunków bioklimatycznych na obszarze miasta, wykorzystującw tym celu nowy wskaźnik bioklimatyczny Universal Thermal Climate Index (UTCI). Otrzymane mapy biotopoklimatyczne opracowane zostały w odniesieniu do sześciu określonych scenariuszy pogodowych. Uzyskane obrazy, będące teoretycznym przybliżeniem warunków rzeczywistych, pozwalają ocenić wpływ rzeźby oraz typów użytkowania terenu na kształtowanie warunków biometeorologicznych obszarów zurbanizowanych. W analizowanych scenariuszach pogodowych i przy uwzględnieniu rzeźby Lublina najwyższe modelowane wartości UTCI charakteryzują zbocza wąwozów oraz dolin o południowej ekspozycji. W obszarach tych prognozowane są warunki biometeorologiczne, odzwierciedlające obciążenia cieplne „bardzo silny stres ciepła”.
Źródło:
Annales Universitatis Mariae Curie-Sklodowska, sectio B – Geographia, Geologia, Mineralogia et Petrographia; 2013, 68, 1
0137-1983
Pojawia się w:
Annales Universitatis Mariae Curie-Sklodowska, sectio B – Geographia, Geologia, Mineralogia et Petrographia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bodźcowość warunków biometeorologicznych we Wrocławiu
Stimulating qualities of biometeorological conditions in Wrocław
Autorzy:
Bryś, Krystyna
Ojrzyńska, Hanna
Powiązania:
https://bibliotekanauki.pl/articles/578455.pdf
Data publikacji:
2016
Wydawca:
Łódzkie Towarzystwo Naukowe
Tematy:
wskaźnik obciążeń cieplnych człowieka UTCI
stres ciepła
stres chłodu
Wrocław
składowe całkowitego bilansu promieniowania słonecznego
Universal Thermal Climate Index UTCI
heat stress
cold stress
component of solar radiation balance
Opis:
Bodźcowość warunków biometeorologicznych we Wrocławiu przeanalizowana została na podstawie wartości wskaźnika oceny obciążeń cieplnych człowieka UTCI (Universal Thermal Climate Index) w latach 2008–2014. Wyliczono je z danych o kroku godzinowym otrzymanych z Obserwatorium Agro- i Hydrometeorologii Uniwersytetu Przyrodniczego we Wrocławiu, z uwzględnieniem składowych całkowitego bilansu promieniowania słonecznego. Analizie poddane zostały roczne i wieloletnie przebiegi wartości wskaźnika UTCI oraz częstość występowania klas wartości wskaźnika odpowiadających określonej bodźcowości (stres ciepła i zimna). Dla wybranych okresów fal ciepła i chłodu porównano przebiegi głównych meteorologicznych determinant wskaźnika UTCI. Potwierdzono słabą bodźcowość warunków biometeorologicznych Wrocławia. Wykazano, że warunki biometeorologiczne wrocławskich przedmieść charakteryzują się znaczną frekwencją braku obciążeń cieplnych. Zaznaczono, że w ostatnich latach wzrasta liczba sytuacji ze stresem zimna, co w obszarach o stosunkowo niskiej szorstkości podłoża spowodowane jest dynamiką ruchu powietrza w częściej występujących sytuacjach cyklonalnych.
Stimulating qualities of biometeorological conditions of Wrocław were analyzed on the basis of the values of the Universal Thermal Climate Index (UTCI) of the years 2008–2014. UTCI values were calculated from 1-hour data with the use of components of solar radiation balance, measured in the Agro- and Hydrometeorological Observatory of Wrocław University of Environmental and Life Science. Annual and long-standing courses of UTCI and the occurrence frequency of UTCI levels corresponding to a specific stimulating condition (heat and cold stress) were analyzed. For the selected coldwave and heat-wave, the courses of the main meteorological determinants of UTCI were compared. It was demonstrated that the biometeorological conditions of Wrocław suburbia are characterized by a considerable frequency of heat load deficit. It was remarked that the number of incidents of cold stress has increased in recent years. In in the areas of relatively smal l surface roughness, the reason can be attributed to the dynamics of the wind in more frequently occurring cyclonic circulation.
Źródło:
Acta Geographica Lodziensia; 2016, 104; 193-200
0065-1249
Pojawia się w:
Acta Geographica Lodziensia
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies