Tytuł:
Modeling and Simulation of Multi-machine System Using UPFC for Enhancing Transient Stability
Autorzy:
Singh, Amritpreet
Mathew, Lini
Powiązania:
https://bibliotekanauki.pl/articles/1158636.pdf
Data publikacji:
2018
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
FACTS
Reactive Power compensation
Transient Stability
UPFC
Opis:
In this paper, transient stability of IEEE 9- bus system combined with Unified Power Flow Controller (UPFC), has been accomplished. UPFC based on Voltage Source Controller (VSC) has a higher switching frequency, an obvious voltage harmonic and a lower voltage level. Under a symmetrical three-phase short circuit with a different fault locations were used and the load angle variation also studied to test the control performance. The multi machine system combined with UPFC controller, perform outstanding to reduce damping oscillation in power system observed in results of simulation.
Źródło:
World Scientific News; 2018, 114; 152-163
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A coefficient diagram method based AGC mechanism for an interconnected power system in coordination with UPFC and AC/DC link
Autorzy:
Sahani, A.K.
Shankaro, Ravi
Sariki, Murali
Mandal, Rajib Kumar
Powiązania:
https://bibliotekanauki.pl/articles/140700.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
AGC
AC/DC link
CDM
GDB
GRC
UPFC
Opis:
Frequency regulation is in a first line of preference for an interconnected power system. Presence of nonlinearities in the generation systems further raises the complexity level of the problem. In this scenario, this article presents a robust Automatic Generation Control (AGC) mechanism to maintain the frequency and tie-line power of the power system to their nominal values. A Coefficient Diagram Method (CDM) based AGC mechanism including an AC/DC tie-line and Unified Power Flow Controller (UPFC) has been developed and the performance in handling the frequency regulation has been analyzed. The nonlinearities such as Governor Dead-Band (GDB) and Generation Rate Constraint (GRC) are included in the system to analyze the proposed AGC scheme in a more realistic approach. The AC/DC tie-line and UPFC which are included in the proposed AGC scheme provides an immense strength to handle the active power variation as-well-as frequency regulation. To develop a more effective AGC scheme, the parameters of an AC/DC tie-line and UPFC are optimized by successful implementation of the Fruit Fly Optimization Algorithm (FOA). The justification of the proposed AGC scheme has been carried out through a step by step verification such as justifying the CDM based controller, effectiveness of the proposed scheme and robustness of the system against parameters variation. The CDM based controller has been compared with the conventional controllers to elevate the effectiveness and the supremacy of the proposed AGC scheme has been examined by comparing with previously published work. The design and simulation of the work has been carried out by the MATLAB/Simulink® tool box.
Źródło:
Archives of Electrical Engineering; 2020, 69, 2; 287-302
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ trybów pracy układu UPFC na estymację stanu systemu elektroenergetycznego
Autorzy:
Okoń, T.
Wilkosz, K.
Powiązania:
https://bibliotekanauki.pl/articles/397338.pdf
Data publikacji:
2011
Wydawca:
ENERGA
Tematy:
układ UPFC
system elektroenergetyczny
estymacja
UPFC system
power system
estimation
Opis:
Artykuł dotyczy estymacji stanu systemu elektroenergetycznego, w którym zainstalowany jest układ UPFC. Układ UPFC może pracować w różnych trybach: pełne wykorzystanie jego funkcji, realizacja funkcji tylko układu SSSC, realizacja funkcji tylko układu STATCOM oraz całkowite wyłączenie układu. Celem artykułu jest przedstawienie wyników analizy estymacji stanu, gdy nie jest w niej wykorzystywana informacja o aktualnym trybie pracy układu UPFC. Własności estymacji stanu przeprowadzanej we wskazanych przypadkach są porównywane z punktu widzenia uwarunkowania estymacyjnego procesu obliczeniowego, dokładności estymacji oraz liczby iteracji, po której otrzymywany jest wynik.
Źródło:
Acta Energetica; 2011, 3; 53-59
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of UPFC for enhancement of voltage profile and minimization of losses using Fast Voltage Stability Index (FVSI)
Autorzy:
Kumar, S.
Renuga, P.
Powiązania:
https://bibliotekanauki.pl/articles/140514.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
flexible AC transmission system (FACTS)
real and reactive power
Unified Power Flow Controller (UPFC)
Bacterial Foraging (BF) algorithm
Opis:
Transmission line loss minimization in a power system is an important research issue and it can be achieved by means of reactive power compensation. The unscheduled increment of load in a power system has driven the system to experience stressed conditions. This phenomenon has also led to voltage profile depreciation below the acceptable secure limit. The significance and use of Flexible AC Transmission System (FACTS) devices and capacitor placement is in order to alleviate the voltage profile decay problem. The optimal value of compensating devices equires proper optimization technique, able to search the optimal solution with less computational burden. This paper presents a technique to provide simultaneous or individual controls of basic system parameter like transmission voltage, impedance and phase angle, thereby controlling the transmitted power using Unified Power Flow Controller (UPFC) based on Bacterial Foraging (BF) algorithm. Voltage stability level of the system is defined on the Fast Voltage Stability Index (FVSI) of the lines. The IEEE 14-bus system is used as the test system to demonstrate the applicability and efficiency of the proposed system. The test result showed that the ocation of UPFC improves the voltage profile and also minimize the real power loss.
Źródło:
Archives of Electrical Engineering; 2012, 61, 2; 239-250
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania układu UPFC w oparciu o model laboratoryjny i symulacyjny
Testing of a laboratory and simulation model of UPFC
Autorzy:
Kosmecki, M.
Małkowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/267598.pdf
Data publikacji:
2016
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
UPFC
szybkie prototypowanie
Simulink Real-Time
symulacje w czasie rzeczywistym
FACTS
laboratorium systemów elektroenergetycznych
Unified Power Flow Controller
Rapid Control Prototyping
Real Time Digital Simulation
Power System Laboratory
Opis:
W artykule przedstawiono koncepcję oraz sposób realizacji laboratoryjnego modelu układu UPFC. Układ zrealizowano według nowej metodyki oferującej elastyczność w szerokim zakresie testowania nowych algorytmów sterowania. W referacie zaprezentowano też przykładowe wyniki prób eksperymentalnych potwierdzające słuszność przyjętej koncepcji sterowania. Dane pomiarowe zostały również wykorzystane do celów walidacji opracowanego modelu UPFC.
This paper presents a laboratory unit of Unified Power Flow Controller (UPFC), whose operational performance is assessed based on the results of tests carried out in commissioning phase of the project during which steady state and transient performance were mainly investigated. Measurement data were also used for validation purposes of the elaborated transient model of UPFC.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2016, 50; 27-32
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimal robust stabilizer design based on UPFC for interconnected power systems considering time delay
Autorzy:
Koofigar, H. R.
Isazadeh, G.
Powiązania:
https://bibliotekanauki.pl/articles/140441.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
UPFC
mixed H2 /H∞
LMI
wide area
power system oscillations
time delay
Opis:
A robust auxiliary wide area damping controller is proposed for a unified power flow controller (UPFC). The mixed H2 /H∞ problem with regional pole placement, resolved by linear matrix inequality (LMI), is applied for controller design. Based on modal analysis, the optimal wide area input signals for the controller are selected. The time delay of input signals, due to electrical distance from the UPFC location is taken into account in the design procedure. The proposed controller is applied to a multimachine interconnected power system from the IRAN power grid. It is shown that the both transient and dynamic stability are significantly improved despite different disturbances and loading conditions.
Źródło:
Archives of Electrical Engineering; 2017, 66, 3; 459-474
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Power flow analysis and control of distributed FACTS devices in power system
Autorzy:
Anand, V.
Mallik, S. K.
Powiązania:
https://bibliotekanauki.pl/articles/141190.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
D-FACTS
UPFC
power flow control
stability
THD
FACTS
Opis:
The deployment of a distributed power-flow controller (DPFC) in a single- machine infinite-bus power system with two parallel transmission lines are considered for the analysis in this paper. This paper presents the network analysis of the DPFC for power flow control. The performance is evaluated on a given test system with a single line-to- ground fault. The improvement in the stability as well as power quality is evident from the results. Thus the DPFC has the ability to enhance the stability and power quality of the system.
Źródło:
Archives of Electrical Engineering; 2018, 67, 3; 545--561
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies