Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Ti-6Al-7Nb" wg kryterium: Temat


Tytuł:
Influence of the Electrochemical Anodizing Parameters on the Microstructure, Microroughness and Microhardness of Anodized Ti-6Al-7Nb
Autorzy:
Veselinov, Deyan
Skulev, Hristo
Powiązania:
https://bibliotekanauki.pl/articles/351823.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
anodizing
surface oxidation
electrochemical
titanium alloy
Ti-6Al-7Nb
Opis:
This paper presents a study on anodizing titanium alloy Ti-6Al-7Nb in electrolyte of dilute sulfuric acid. The effects of the parameters – voltage, anodizing time, and electrode distance on the anodic film properties have been investigated. The anodic layers are found to become more compact with the increase of the applied voltage in the electrolytic cell. The microstructure, chemical element distribution and mechanical properties, i.e. microroughness and microhardness of the anodic coatings obtained at different operating conditions have been evaluated.
Źródło:
Archives of Metallurgy and Materials; 2020, 65, 3; 1223-1226
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biodegradable polymer coatings on Ti6Al7Nb alloy
Autorzy:
Szewczenko, Janusz
Kajzer, Wojciech
Kajzer, Anita
Basiaga, Marcin
Kaczmarek, Marcin
Antonowicz, Magdalena
Nowińska, Katarzyna
Jaworska, Joanna
Jelonek, Katarzyna
Kasperczyk, Janusz
Powiązania:
https://bibliotekanauki.pl/articles/306476.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
Ti6Al7Nb
powłoka polimerowa
zwilżalność
odporność na korozję
uwalnianie jonów
przyczepność
biodegradable polymer coating
wettability
corrosion resistance
ion release
adhesion of polymer coatings
Opis:
The aim of the study was to determine the influence of long term exposure to Ringer’s solution of biodegradable polymer coatings containing an active substance on the Ti6Al7Nb alloy substrate on the physical and chemical properties of the coatings and the degradation process of the metal substrate. The studies used poly(L-lactide-co-trimethylene carbonate) P(L/TMC), poly(L-lactide-co-trimethylene carbonate-glycolide) P(L/TMC/G) and poly(D,L-lactide-glycolide) (PLGA) coatings applied to the anodically oxidized Ti6Al7Nb alloy by means of dipping method (1, 2 and 3 dips). The polymer coatings contained ciprofloxacin. Roughness and wettability tests were carried out on the substrate and polymer coatings, the pitting corrosion resistance of the substrate and samples with polymer coating was determined, the number of metallic ions released to the solution from the coated and uncoated samples was determined as well as the adhesion of polymer coatings. The research was supplemented by microscopic observations. The results of the research indicate different influence of exposure to Ringer’s solution on the physical and chemical properties of biodegradable polymer coatings containing ciprofloxacin and the course of the degradation process of the metal substrate.
Źródło:
Acta of Bioengineering and Biomechanics; 2019, 21, 4; 83-92
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of various antibacterial, biodegradable polymeric coatings developed on Ti6Al7Nb surface
Autorzy:
Jaworska, J.
Jelonek, K.
Jaworska, M.
Kajzer, W.
Szewczenko, J.
Pastusiak, M.
Kasperczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/285816.pdf
Data publikacji:
2018
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
polymeric coatings
biodegradable
Ti6Al7Nb alloys
Źródło:
Engineering of Biomaterials; 2018, 21, 148; 31
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Initial in vivo biocompatybility evaluation of modified Ti6Al7Nb alloy surface
Autorzy:
Gonsior, M.
Zawidlak-Węgrzyńska, B.
Janiczak, K.
Tarnowski, M.
Wierzchoń, T.
Kustosz, R.
Barski, J.
Grajoszek, A.
Wojnicz, R.
Warmusz, E.
Powiązania:
https://bibliotekanauki.pl/articles/285896.pdf
Data publikacji:
2018
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
Ti6Al7Nb alloys
biocompatibility
surfaces
Źródło:
Engineering of Biomaterials; 2018, 21, 148; 82
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Formation of functional coatings on Ti-6Al-7Nb alloy surface
Autorzy:
Nosol, A.
Simka, W.
Kazek-Kęsik, A.
Powiązania:
https://bibliotekanauki.pl/articles/284582.pdf
Data publikacji:
2017
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
Ti6Al7Nb alloys
anodization
bone tissue
Źródło:
Engineering of Biomaterials; 2017, 20, no. 143 spec. iss.; 82
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Properties of Ti-6Al-7Nb titanium alloy nitrocarburized under glow discharge conditions
Autorzy:
Kajzer, A.
Grzeszczuk, O.
Kajzer, W.
Nowińska, K.
Kaczmarek, M.
Tarnowski, M.
Wierzchoń, T.
Powiązania:
https://bibliotekanauki.pl/articles/306236.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
Ti-6Al-7Nb alloy
diffusive nitrocarburized layer
mechanical properties
electrochemical properties
Opis:
The paper presents the results of physicochemical and mechanical properties of the Ti-6Al-7Nb alloy with surface modified by formation of a diffusive nitrocarburized layer deposited in a low-temperature plasma process. The main aim of the study was to evaluate the influence of steam sterilization and exposure to Ringer’s solution on the utility properties of the alloy. Methods: Based on the study of the microstructure, roughness, wettability, resistance to pitting corrosion, ion infiltration and mechanical properties, the usefulness of the proposed method of surface treatment for clinical application was proven. Results: Deposition of the nitrocarburized layer increased the surface roughness and surface hardness, but also reduced the contact angle, and corrosion resistance with respect to the polished surfaces. The nitrocarburized layer is a barrier against the infiltration of ions to the solution and sterilization and exposure to Ringer solution have greater effect on the physicochemical properties rather than on the mechanical ones. Conclusion: It was found that sterilization, and exposure to Ringer’s solution greatly affect the change of physicochemical properties rather than mechanical properties for both nitrocarburized layers and the Ti-6Al-7Nb alloy of mechanically polished surface.
Źródło:
Acta of Bioengineering and Biomechanics; 2017, 19, 4; 181-188
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ti6Al7Nb alloy surface improvement for implantable blood pumps applications
Autorzy:
Gonsior, M.
Tarnowski, M.
Janiczak, K.
Zawidlak-Węgrzyńska, B.
Wierzchoń, T
Gawlikowski, M.
Kustosz, R.
Powiązania:
https://bibliotekanauki.pl/articles/286034.pdf
Data publikacji:
2017
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
Ti6Al7Nb alloys
blood pump
implantation
Źródło:
Engineering of Biomaterials; 2017, 20, no. 143 spec. iss.; 65
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie własności mechanicznych powłoki polimerowej na podłożu ze stopu Ti6Al7Nb
Mechanical properties of polymer coating on Ti6Al7Nb substrate
Autorzy:
Solarz, J.
Grygiel-Pradelok, M.
Kajzer, W.
Szewczenko, J.
Powiązania:
https://bibliotekanauki.pl/articles/99169.pdf
Data publikacji:
2016
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
PLGA
Ti6Al7Nb
adhezja powłok polimerowych
twardość powłok polimerowych
Ti-6Al-7Nb
polymer coating adhesion
polymer coating hardness
Opis:
W pracy przedstawiono wpływ sposobu modyfikacji powierzchni stopu Ti6Al7Nb na własności mechaniczne naniesionej powłoki biodegradowalnego polimeru poli(D,L-laktyd-ko-glikolid) (PLGA). Zakres badań obejmował: pomiary chropowatości oraz obserwacje makroskopowe powierzchni metalowego podłoża oraz obserwacje powierzchni powłoki polimerowej, badanie adhezji do podłoża oraz ultrananotwardości. Badania wykazały istotny wpływ sposobu modyfikowania powierzchni podłoża ze stopu Ti6Al7Nb na własności mechaniczne powłoki polimeru PLGA.
The study describes results of research influence of methods for modifying the surface of the Ti6Al7Nb alloy on the mechanical properties of the applied coating of biodegradable polymer poli(lactid-co-glicolic acid) (PLGA). The research included: assessment of the macroscopic surface of samples in the initial state and after applied polymer coating, measurements of surface roughness of the metal substrate, scratch test and ultrananohardness test. Research has shown a significant impact of used method of modifying metal substrate on mechanical properties of the PLGA coating. The analysis also showed dependence of adhesion polymer coating on roughness of the metal substrate.
Źródło:
Aktualne Problemy Biomechaniki; 2016, 10; 69-74
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena stopnia proliferacji komórek osteoblastopodobnych w kontakcie z powierzchniami stopu tytanu po piaskowaniu do różnego stopnia chropowatości
Evaluation of proliferation rate of osteoblast-like cells in contact with titanium alloy surfaces sandblasted to different roughness level
Autorzy:
Bociąga, D.
Olejnik, A.
Jastrzębski, K.
Sobczyk-Guzenda, A.
Paradowska, J.
Powiązania:
https://bibliotekanauki.pl/articles/284193.pdf
Data publikacji:
2016
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
piaskowanie
osteoblasty
Ti-6Al-4V
Ti-6Al-7Nb
obróbka powierzchniowa
sandblasting
osteoblasts
surface treatment
Opis:
Tytan i jego stopy są jednymi z najpopularniejszych biomateriałów metalicznych stosowanych w dzisiejszej implantologii. Mimo licznych zalet tych materiałów, wykonane z nich wszczepy często poddaje się dodatkowej obróbce powierzchni, której celem jest polepszenie integracji implantu z otaczającymi go tkankami. Spośród wielu dostępnych technik, jedną z najczęściej wykorzystywanych komercyjnie jest stosunkowo tania i szybka metoda piaskowania, polegająca na wystawianiu danego przedmiotu na kontakt ze strumieniem przyspieszonych cząstek materiału ściernego. Celem tej pracy była analiza wpływu piaskowania ścierniwem o różnej średnicy ziaren na właściwości obrabianej powierzchni elementów na bazie dwóch popularnych stopów tytanu: Ti-6Al-4V i Ti-6Al-7Nb. W celu scharakteryzowania uzyskanych powierzchni przeprowadzono badania ich topografii, składu chemicznego, chropowatości i zwilżalności. Ponadto, aby sprawdzić potencjalną reakcję organizmu na obecność obrobionych w ten sposób elementów dokonano oceny stopnia proliferacji ludzkich komórek kościotwórczych hodowanych w bezpośrednim kontakcie z przygotowanymi powierzchniami. Otrzymane wyniki wykazały wyraźną zależność pomiędzy stopniem chropowatości i składem chemicznym piaskowanych elementów, a zastosowanym do obróbki rodzajem medium ściernego. Badanie zachowania komórek będących w kontakcie z modyfikowanymi próbkami wykazało obniżoną skłonność osteoblastów do przylegania i namnażania na najbardziej chropowatych powierzchniach.
Titanium and its alloys are very popular metallic biomaterials used for medical implants production. Despite numerous advantages of the bulk material, such implants are very often subjected to additional surface treatment in order to improve their integration within the body tissues. Besides many other available techniques, one of the most frequently used in the commercial sector is a fast and economically profitable process of abrasive blasting. It is a method in which a stream of accelerated particles collides with the implant surface what causes changes in the material properties. The following paper presents differences resulting from sandblasting of Ti-6Al-4V and Ti-6Al-7Nb specimens with blasting particles varying in size. In order to characterize the outcome of such the treatment, investigations of surface topography, chemical composition, roughness, and wettability were conducted. Finally, the behaviour of the osteoblast- -like cells adhered to the sandblasted Ti-6Al-4V and Ti-6Al-7Nb surfaces was assessed in order to evaluate potential body response towards the aforementioned materials. The results suggest a strong correlation between surface roughness, its chemistry and the type of blasting medium applied. Evaluation of the cell culture revealed a rapid decrease in cell proliferation rate onto the roughest surfaces.
Źródło:
Engineering of Biomaterials; 2016, 19, 134; 8-17
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Plasma oxidized Ti6Al4V and Ti6Al7Nb alloys for biomedical applications
Autorzy:
Pązik, B.
Grabarczyk, J.
Batory, D.
Kaczorowski, W.
Burnat, B.
Czerniak-Reczulska, M.
Makówka, M.
Niedzielski, P.
Powiązania:
https://bibliotekanauki.pl/articles/285698.pdf
Data publikacji:
2016
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
Ti6Al4V alloy
Ti-6Al-7Nb alloy
biomaterials
Źródło:
Engineering of Biomaterials; 2016, 19, 138; 68
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The chemical digestion of Ti6Al7Nb scaffolds produced by Selective Laser Melting reduces significantly ability of Pseudomonas aeruginosa to form biofilm
Autorzy:
Junka, A. F.
Szymczyk, P.
Secewicz, A.
Pawlak, A.
Smutnicka, D.
Ziółkowski, G.
Bartoszewicz, M.
Chlebus, E.
Powiązania:
https://bibliotekanauki.pl/articles/307092.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
technologia SLM
Pseudomonas aeruginosa
skafoldy
modyfikacja powierzchni
Ti-6Al-7Nb
SLM technology
scaffolds
surface modification
Opis:
In our previous work we reported the impact of hydrofluoric and nitric acid used for chemical polishing of Ti-6Al-7Nb scaffolds on decrease of the number of Staphylococcus aureus biofilm forming cells. Herein, we tested impact of the aforementioned substances on biofilm of Gram-negative microorganism, Pseudomonas aeruginosa, dangerous pathogen responsible for plethora of implant-related infections. The Ti-6Al-7Nb scaffolds were manufactured using Selective Laser Melting method. Scaffolds were subjected to chemical polishing using a mixture of nitric acid and fluoride or left intact (control group). Pseudomonal biofilm was allowed to form on scaffolds for 24 hours and was removed by mechanical vortex shaking. The number of pseudomonal cells was estimated by means of quantitative culture and Scanning Electron Microscopy. The presence of nitric acid and fluoride on scaffold surfaces was assessed by means of IR and rentgen spetorscopy. Quantitative data were analysed using the Mann–Whitney test (P ≤ 0.05). Our results indicate that application of chemical polishing correlates with significant drop of biofilm-forming pseudomonal cells on the manufactured Ti-6Al-7Nb scaffolds ( p = 0.0133, Mann–Whitney test) compared to the number of biofilm-forming cells on non-polished scaffolds. As X-ray photoelectron spectroscopy revealed the presence of fluoride and nitrogen on the surface of scaffold, we speculate that drop of biofilm forming cells may be caused by biofilm-supressing activity of these two elements.
Źródło:
Acta of Bioengineering and Biomechanics; 2016, 18, 1; 115-120
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ wielokrotnej sterylizacji na właściwości biomateriałów
Influence of the multiple sterilization process on the biomaterial properties
Autorzy:
Bociąga, D.
Jastrzębski, K.
Olejnik, A.
Świątek, L.
Marchwicka, M.
Powiązania:
https://bibliotekanauki.pl/articles/285826.pdf
Data publikacji:
2016
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
Ti6Al4V
Ti6Al7Nb
wielokrotna sterylizacja
chropowatość powierzchni
zwilżalność
biozgodność
Ti-6Al-7Nb
multiple sterilization
surface roughness
wettability
biocompatibility
Opis:
Materiały metaliczne, między innymi stopy tytanu posiadają liczne właściwości, które pozwalają na ich częste stosowanie do produkcji wyrobów biomedycznych. Wszystkie urządzenia przeznaczone do celów medycznych przed użyciem muszą przejść proces sterylizacji. W praktyce niektóre z nich mogą być poddane więcej niż jednemu cyklowi sterylizacji przed umieszczeniem w ciele pacjenta. Pomimo tego, że sterylizacja jest jednym ze standardowych procesów, któremu podlegają wszystkie implanty, może być ona przyczyną zmian właściwości powierzchniowych materiału. Celem niniejszej pracy było sprawdzenie, jak proces wielokrotnej sterylizacji wpływa na właściwości powierzchniowe oraz odpowiedź komórkową dla grupy próbek wykonanych z dwóch stopów tytanu: Ti6Al4V i Ti6Al7Nb. Wypolerowane próbki obu stopów zostały poddane jednemu, pięciu oraz dziesięciu cyklom sterylizacji parowej. Próbki zostały przebadane pod kątem morfologii powierzchni (SEM) oraz składu chemicznego (EDS), a także topografii powierzchni (profilometr) oraz zwilżalności (pomiar kąta zwilżania metodą kropli). Badania cytotoksyczności i proliferacji komórek zostały przeprowadzone poprzez wykonanie testu live/dead z wykorzystaniem komórek kościotwórczych linii Saos-2. Przeprowadzone badania dowodzą, że wielokrotna sterylizacja powoduje pojawianie się zanieczyszczeń na powierzchni materiału oraz zwiększenie grubości warstwy tlenkowej. Wartości energii powierzchniowej oraz parametrów chropowatości wzrosły wraz ze wzrostem liczby cykli sterylizacji. Proliferacja komórek na wysterylizowanych próbkach ze stopów tytanu była mniejsza niż w przypadku stali nierdzewnej oraz próbki kontrolnej, chociaż żadna z próbek nie wykazała cytotoksyczności. Porównując dwa przebadane stopy tytanu, mniejsza proliferacja została odnotowana na próbkach Ti6Al7Nb.
Due to their favorable properties, numerous metallic materials, including titanium alloys are chosen for biomedical applications. A final preparation step before the implantation of a metallic biomaterial is sterilization. In fact, some of the devices may undergo a multiple sterilization process before they are placed into the human body. Although sterilization is a part of a standard procedure, it might affect the surface properties of the material. The purpose of this study was to check the influence of multiple sterilization process on surface properties and biological response of two titanium alloys: Ti6Al4V and Ti6Al7Nb. Samples of both alloys were mechanically polished and subjected to 1, 5 or 10 stem sterilization cycles. Representative samples from each group were examined in term of surface morphology (SEM), chemical composition (EDS), topography (profilometer) and wettability (sessile drop technique). Cell proliferation and cytotoxicity assay were carried out with the use of live/dead test of Saos-2 osteoblast-like cells line. Examinations showed that the multiple sterilization process caused occasional appearance of contaminations on the surfaces, as well as increase in the oxide layer thickness. Values of surface energy and surface roughness parameters increased with the increasing number of sterilization cycles. Proliferation of cells on the surface of sterilized titanium alloys was lower than in the case of stainless steel and control sample. At the same time, none of the examined samples showed cytotoxicity. Comparing two titanium alloys, considerably lower number of cells was observed on Ti6Al7Nb surface.
Źródło:
Engineering of Biomaterials; 2016, 19, 136; 11-20
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of post-process operations on the mechanical properties of titanium alloy Ti-6Al-7Nb, produced by selective laser melting
Autorzy:
Karoluk, M.
Chlebus, E.
Powiązania:
https://bibliotekanauki.pl/articles/1190025.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
selektywne spiekanie laserowe
SLM
stop tytanu
Ti-6Al-7Nb
selective laser melting
post-process operations
titanium alloy
Opis:
Even though selective laser melting (SLM) has been available for more than a decade, during few last years the interest in this technology has grown extremely. SLM technology allows to fabricate fully functional and complex metal objects, layer by layer, via selective melting of material using laser beam. However, producing object by melting thin layers of material causes conditions of fast heat removal. This phenomenon leads to equilibrium microstructures, accompanied by the residual stresses which cause the decrease of mechanical properties. The following paper presents the result of research in the field of the influence of the post-process operations, such as machining and heat treatment, on the mechanical properties of alloy Ti-6Al-7Nb build by SLM.
Źródło:
Interdisciplinary Journal of Engineering Sciences; 2015, 3, 1; 16--19
2300-5874
Pojawia się w:
Interdisciplinary Journal of Engineering Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu mikrostruktury na odporność korozyjną stopu tytanu Ti6Al7Nb
The analysis of the effect of microstructure on the corrosion resistance of titanium alloy Ti6Al7Nb
Autorzy:
Zięty, A.
Lachowicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/99013.pdf
Data publikacji:
2014
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
Ti6Al7Nb
biomateriał
mikrostruktura
obróbka cieplna
Ti-6Al-7Nb
biomaterial
microstructure
thermal treatment
Opis:
Stopy tytanu, takie jak Ti6Al4V, czy analizowany Ti6Al7Nb należą do stopów o strukturze dwufazowej α+β. Kształtowanie ich mikrostruktury wynika ze specyficznych cech fizycznych tytanu, ale i z warunków odkształcania na gorąco oraz obróbki cieplnej. Procesy te powinny uwzględniać związek między mikrostrukturą a wytrzymałością implantu, jego twardością, plastycznością, odpornością na zmęczenie, zużycie ścierne i co najważniejsze – odpornością na korozję. Przeanalizowano istniejącą literaturę pod kątem wpływu mikrostruktury stopu tytanu Ti6Al7Nb na jego odporność korozyjną w symulowanych płynach ustrojowych. Jej różnorodność związana jest ze sposobem przetwarzania stopu, co również było obiektem analizy i obserwacji.
Titanium alloys, such as Ti6Al4V, or analyzed in this paper Ti6Al7Nb alloys are two-phase structure of α + β. Shaping their microstructure due to the specific physical characteristics of the titanium, its hot deformation and heat treatment. These processes should take into account the relation between the microstructure and strength of the implant, its hardness, ductility, resistance to fatigue, wear and what is the most important - corrosion resistance. Existing literature was analyzed for effects of titanium alloy microstructure Ti6Al7Nb its corrosion resistance in simulated body fluids. It is associated with a variety of melt processing method, which also has been the subject of analysis and observation.
Źródło:
Aktualne Problemy Biomechaniki; 2014, 8; 187-192
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania własności mechanicznych warstw SiO2 przeznaczonych na implanty stosowane w układzie krwionośnym
Tests of mechanical properties of SiO2 layers for implants used in vascular system
Autorzy:
Walke, W.
Basiaga, M.
Paszenda, Z.
Powiązania:
https://bibliotekanauki.pl/articles/283862.pdf
Data publikacji:
2014
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
Ti
Ti6Al7Nb
metoda zol-żel
scratch test
nanotwardość
Ti-6Al-7Nb
sol-gel method
nanohardness
Opis:
Jednym ze sposobów zwiększania hemokompatybilności powierzchni biomateriałów tytanowych jest wykorzystanie metody zol-żel dla wytworzenia cienkich powłok tlenkowych na bazie takich pierwiastków jak: Ti i Si. Takie warstwy są bardziej hemokompatybilne, co znacznie ogranicza ryzyko komplikacji związanej chociażby z procesem wykrzepiania. Oprócz poprawy hemokompatybilności istotnym zagadnieniem związanym z wytwarzaniem warstw jest również odpowiedni zespół własności mechanicznych. Zaletą tej metody jest niska temperatura otrzymywania powłoki, co gwarantuje niezmienność własności mechanicznych podłoża metalowego. Dlatego też w pracy przeprowadzono badania własności mechanicznych warstw krzemionkowych naniesionych na powierzchnię próbek z tytanu Grade4 oraz stopu Ti-6Al-7Nb. Próbki poddano obróbce powierzchniowej obejmującej następujące procesy: polerowanie mechaniczne oraz naniesienie warstwy SiO2 metodą zol-żel. Ocenę własności mechanicznych przeprowadzono w oparciu o badania nanotwardości oraz przyczepności warstwy do podłoża. Pomiary nanotwardości przeprowadzono metodą Olivera & Pharra z wykorzystaniem wgłębnika Berkovicha. Z kolei badania przyczepności przeprowadzono metodą zarysowania – scratch test. Do badań wykorzystano platformę otwartą Micro-Combi-Tester firmy CSM Instruments. Przeprowadzone badania wykazały, że warstwa krzemionkowa wytworzona zarówno na powierzchni tytanu Grade4, jak i na stopie Ti-6Al-7Nb posiada identyczne własności mechaniczne. Dodatkowo stwierdzono, że uzyskane wyniki badań adhezji wskazują na małą przyczepność warstwy SiO2 do podłoża zarówno z tytanu Grade 4 oraz stopu tytanu Ti-6Al-7Nb. W obu przypadkach nie wystąpił sygnał emisji akustycznej, co świadczy o niskiej energii wiązania warstwy z podłożem.
One of the ways how to increase haemocompatibility of the surface of titanium biomaterials is an application of sol-gel method in order to create thin oxide layers on the base of such elements as Ti and Si. Such layers are more haemocompatible, which reduces substantially the risk of complications connected with, for example, coagulation process. Apart from improvement of haemocompatibility, an important issue connected with creation of those layers is also proper selection of their mechanical properties. An advantage of that method is low temperature at which the layer is obtained, what guarantees stability of mechanical properties of metallic substrate. Therefore, this study presents tests of mechanical properties of silicone layers applied on titanium Grade4 and Ti-6Al-7Nb alloy surface. Samples were subjected to surface treatment: mechanical polishing and then SiO2 layer was applied by means of sol-gel method. Evaluation of mechanical properties was realized by the tests of nano-hardness and adhesion of the layer to the substrate. Nano-hardness tests were made with application of Oliver & Pharr method and Berkovich intending tool while adhesion tests were performed with application of scratch test. For the tests Micro-Combi-Tester Open platform was used. The results showed that silicone layer created both on titanium Grade4 and Ti-6Al-7Nb alloy surface features similar mechanical properties. Obtained results show low adhesion of SiO2 layer to the substrate made of titanium Grade 4 and titanium alloy Ti-6Al-7Nb. In both cases there was no acoustic emission signal, which proves low bonding energy between the layer and the substrate.
Źródło:
Engineering of Biomaterials; 2014, 17, 124; 36-41
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies