Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Ti-6Al-7Nb" wg kryterium: Temat


Tytuł:
Polerowanie elektrolityczne stopu Ti6Al7Nb
Electropolishing of Ti6Al7Nb alloy
Autorzy:
Łyczkowska, E.
Chlebus, E.
Powiązania:
https://bibliotekanauki.pl/articles/99218.pdf
Data publikacji:
2013
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
Ti6Al7Nb
elektropolerowanie
implant
Ti-6Al-7Nb
electropolishing
Opis:
This paper presents review of methods for treatment of Ti6Al7Nb alloy surfaces which may be used as implants. Electro-chemical polishing is a process of improving micro smoothness and material brightness by anodic dissolving of the substrate in an electrolyte. Samples were electropolished in 2 electrolytes consisting of H₂SO₄, HF and org. additives. Ti6Al7Nb details after electrochemical polishing get better corrosion resistance and excellent visual effects. The roughness after EP was 0,08-0,13 Ra.
W artykule omówiono właściwości stopu Ti-6Al-7Nb, jego zastosowanie w implantologii oraz sposoby obróbki powierzchni poprzez obróbkę mechaniczną oraz elektrolityczną. Przedstawiono wyniki elektropolerowania próbek w kąpieli składającej się z kwasu siarkowego(VI), kwasu flurowodorowego, acetanilidu oraz w kąpieli składającej się z kwasu metanosulfonowego i kwasu etidronowego. Przedstawiono również wpływ mechanicznej obróbki przed elektrolitycznym polerowaniem na jakość powierzchni otrzymywanych elementów. Po polerowaniu elektrolitycznym chropowatość próbek wynosiła 0,08-0,13 Ra.
Źródło:
Aktualne Problemy Biomechaniki; 2013, 7; 93-98
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zachowanie elektrochemiczne stopu Ti-6Al-4V i Ti-6Al-7Nb po różnym okresie ekspozycji w SBF
Electrochemical behavior of Ti-6Al-4V and Ti-6Al-7Nb alloy after different time of exposure to SBF
Autorzy:
Pochrząst, M.
Walke, W.
Marciniak, J.
Kaczmarska, D.
Powiązania:
https://bibliotekanauki.pl/articles/285932.pdf
Data publikacji:
2009
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
Ti6Al4V
Ti6Al7Nb
SBF
Ti-6Al-7Nb
Źródło:
Engineering of Biomaterials; 2009, 12, no. 89-91; 152-154
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie technologii przyrostowej SLM w procesie przetwarzania stopu tytanu Ti-6Al-7Nb do zastosowań biomedycznych
Processing of titanium alloy Ti-6Al-7Nb for biomedical application using additive technology selective laser micrometalurgy
Autorzy:
Karoluk, M.
Pawlak, A.
Chlebus, E.
Powiązania:
https://bibliotekanauki.pl/articles/98902.pdf
Data publikacji:
2014
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
technologie przyrostowe
SLM
Ti6Al7Nb
additive technology
Ti-6Al-7Nb
Opis:
Znaczący rozwój w ostatnich latach technologii selektywnej laserowej mikrometalurgii proszków przyczynił się do rozpoczęcia badań nad możliwościami zastosowania tej technologii do wytwarzania nowej generacji implantów kości i ubytków kostnych. W niniejszej pracy został dokonany przegląd w tym kierunku. Ponadto dopasowanie właściwości mechanicznych struktur o otwartej wewnętrznej porowatości do właściwości mechanicznych kości staje się możliwe, poprzez odpowiednie sterowanie parametrami procesu.
A significant development of the selective laser micrometalurgy in recent years, contributed to the beginning of research into the possibilities of applying SLM technology for the production of a new generation of bone implants. The adjustment of the mechanical properties of the produced structures, with open porosity, to the mechanical properties of bone, becomes possible, by appropriate control of process parameters. Moreover, the results of biological tests, which look promising, confirm the right direction of research.
Źródło:
Aktualne Problemy Biomechaniki; 2014, 8; 81-86
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakteryzacja geometryczna i mechaniczna skaffoldów ze stopu TI6AL7NB wytworzonych w technologii laserowej mikrometalurgii
Geometrical and mechanical characterization of scaffolds manufactured from TI-6AL-7NB by laser micrometallurgy – SLM
Autorzy:
Szymczyk, P.
Pawlak, A.
Ziółkowski, G.
Dybała, B.
Chlebus, E.
Powiązania:
https://bibliotekanauki.pl/articles/99269.pdf
Data publikacji:
2013
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
skaffold
Ti6Al7Nb
mikrotomografia komputerowa
SLM
scaffold
Ti-6Al-7Nb
computed microtomography
Opis:
Praca przedstawia wyniki badań struktur mikroskaffoldów wytwarzanych ze stopu Ti6Al7Nb, w technologii laserowej mikrometalurgii proszków metali. Opracowana technologia wytwarzania mikrostruktur kratowych, umożliwia produkowanie regularnie porowatych struktur, składających się z porów w kształcie sześcianu z walcowymi belkami wpisanymi w jego krawędzie. Celem badań było opracowanie metodologii oceny i charakteryzacji wytworzonych struktur.
This paper presents the investigation results on Ti6Al7Nb micro scaffold structures, manufactured in metal powder Selective Laser Melting process. Developed technology of manufacturing lattice microstructures, can produce regular porous structure consisting of pores in the shape of a cube with cylindrical beams entered in the edges. The aim of the study was to develop a methodology for the evaluation and characterization of the produced structures.
Źródło:
Aktualne Problemy Biomechaniki; 2013, 7; 157-162
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu mikrostruktury na odporność korozyjną stopu tytanu Ti6Al7Nb
The analysis of the effect of microstructure on the corrosion resistance of titanium alloy Ti6Al7Nb
Autorzy:
Zięty, A.
Lachowicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/99013.pdf
Data publikacji:
2014
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
Ti6Al7Nb
biomateriał
mikrostruktura
obróbka cieplna
Ti-6Al-7Nb
biomaterial
microstructure
thermal treatment
Opis:
Stopy tytanu, takie jak Ti6Al4V, czy analizowany Ti6Al7Nb należą do stopów o strukturze dwufazowej α+β. Kształtowanie ich mikrostruktury wynika ze specyficznych cech fizycznych tytanu, ale i z warunków odkształcania na gorąco oraz obróbki cieplnej. Procesy te powinny uwzględniać związek między mikrostrukturą a wytrzymałością implantu, jego twardością, plastycznością, odpornością na zmęczenie, zużycie ścierne i co najważniejsze – odpornością na korozję. Przeanalizowano istniejącą literaturę pod kątem wpływu mikrostruktury stopu tytanu Ti6Al7Nb na jego odporność korozyjną w symulowanych płynach ustrojowych. Jej różnorodność związana jest ze sposobem przetwarzania stopu, co również było obiektem analizy i obserwacji.
Titanium alloys, such as Ti6Al4V, or analyzed in this paper Ti6Al7Nb alloys are two-phase structure of α + β. Shaping their microstructure due to the specific physical characteristics of the titanium, its hot deformation and heat treatment. These processes should take into account the relation between the microstructure and strength of the implant, its hardness, ductility, resistance to fatigue, wear and what is the most important - corrosion resistance. Existing literature was analyzed for effects of titanium alloy microstructure Ti6Al7Nb its corrosion resistance in simulated body fluids. It is associated with a variety of melt processing method, which also has been the subject of analysis and observation.
Źródło:
Aktualne Problemy Biomechaniki; 2014, 8; 187-192
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mikrostruktura i właściwości stopu Ti-6Al-7Nb po dyfuzyjnej obróbce utwardzającej tlenem
Microstructure and properties of oxygen diffusion strengthened Ti-6Al-7Nb alloy
Autorzy:
Moskalewicz, T.
Wendler, B.
Zimowski, S.
Milc, S.
Czyrska-Filemonowicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/283843.pdf
Data publikacji:
2009
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
stop Ti-6Al-7Nb
mikrostruktura
obróbka tlenem
Ti-6Al-7Nb alloy
microstructure
oxygen diffusion
Opis:
W pracy przedstawiono charakteryzację mikrostruktury, właściwości mikro-mechanicznych i tribologicznych stopu Ti-6Al-7Nb w stanie dostawy oraz po obróbce utwardzającej tlenem. Badania mikrostruktury przeprowadzono za pomocą skaningowej i transmisyjnej mikroskopii elektronowej na próbkach z przekroju poprzecznego. Stwierdzono, że strefa przypowierzchniowa utwardzonego stopu zbudowana była głównie z roztworu stałego tlenu w tytanie α(O). Zastosowana obróbka powierzchniowa istotnie poprawiła twardość oraz właściwości tribologiczne stopu (wzrost odporności na zużycie przez tarcie, zmniejszenie współczynnika tarcia).
The microstructure as well as micro-mechanical and tribological properties of the as received and glow discharge plasma thermal oxidized Ti-6Al-7Nb alloy were examined. Scanning and transmission electron microscopy investigations on cross-section specimens were used for microstructure investigations. The α (O) solid solution enriched by oxygen up to 22at % was mainly present in the near-surface region. Applied sur-face treatment significantly improved microhardness and tribological properties (wear resistance, friction coefficient) of the alloy.
Źródło:
Engineering of Biomaterials; 2009, 12, no. 89-91; 126-129
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Initial in vivo biocompatybility evaluation of modified Ti6Al7Nb alloy surface
Autorzy:
Gonsior, M.
Zawidlak-Węgrzyńska, B.
Janiczak, K.
Tarnowski, M.
Wierzchoń, T.
Kustosz, R.
Barski, J.
Grajoszek, A.
Wojnicz, R.
Warmusz, E.
Powiązania:
https://bibliotekanauki.pl/articles/285896.pdf
Data publikacji:
2018
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
Ti6Al7Nb alloys
biocompatibility
surfaces
Źródło:
Engineering of Biomaterials; 2018, 21, 148; 82
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania własności mechanicznych warstw SiO2 przeznaczonych na implanty stosowane w układzie krwionośnym
Tests of mechanical properties of SiO2 layers for implants used in vascular system
Autorzy:
Walke, W.
Basiaga, M.
Paszenda, Z.
Powiązania:
https://bibliotekanauki.pl/articles/283862.pdf
Data publikacji:
2014
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
Ti
Ti6Al7Nb
metoda zol-żel
scratch test
nanotwardość
Ti-6Al-7Nb
sol-gel method
nanohardness
Opis:
Jednym ze sposobów zwiększania hemokompatybilności powierzchni biomateriałów tytanowych jest wykorzystanie metody zol-żel dla wytworzenia cienkich powłok tlenkowych na bazie takich pierwiastków jak: Ti i Si. Takie warstwy są bardziej hemokompatybilne, co znacznie ogranicza ryzyko komplikacji związanej chociażby z procesem wykrzepiania. Oprócz poprawy hemokompatybilności istotnym zagadnieniem związanym z wytwarzaniem warstw jest również odpowiedni zespół własności mechanicznych. Zaletą tej metody jest niska temperatura otrzymywania powłoki, co gwarantuje niezmienność własności mechanicznych podłoża metalowego. Dlatego też w pracy przeprowadzono badania własności mechanicznych warstw krzemionkowych naniesionych na powierzchnię próbek z tytanu Grade4 oraz stopu Ti-6Al-7Nb. Próbki poddano obróbce powierzchniowej obejmującej następujące procesy: polerowanie mechaniczne oraz naniesienie warstwy SiO2 metodą zol-żel. Ocenę własności mechanicznych przeprowadzono w oparciu o badania nanotwardości oraz przyczepności warstwy do podłoża. Pomiary nanotwardości przeprowadzono metodą Olivera & Pharra z wykorzystaniem wgłębnika Berkovicha. Z kolei badania przyczepności przeprowadzono metodą zarysowania – scratch test. Do badań wykorzystano platformę otwartą Micro-Combi-Tester firmy CSM Instruments. Przeprowadzone badania wykazały, że warstwa krzemionkowa wytworzona zarówno na powierzchni tytanu Grade4, jak i na stopie Ti-6Al-7Nb posiada identyczne własności mechaniczne. Dodatkowo stwierdzono, że uzyskane wyniki badań adhezji wskazują na małą przyczepność warstwy SiO2 do podłoża zarówno z tytanu Grade 4 oraz stopu tytanu Ti-6Al-7Nb. W obu przypadkach nie wystąpił sygnał emisji akustycznej, co świadczy o niskiej energii wiązania warstwy z podłożem.
One of the ways how to increase haemocompatibility of the surface of titanium biomaterials is an application of sol-gel method in order to create thin oxide layers on the base of such elements as Ti and Si. Such layers are more haemocompatible, which reduces substantially the risk of complications connected with, for example, coagulation process. Apart from improvement of haemocompatibility, an important issue connected with creation of those layers is also proper selection of their mechanical properties. An advantage of that method is low temperature at which the layer is obtained, what guarantees stability of mechanical properties of metallic substrate. Therefore, this study presents tests of mechanical properties of silicone layers applied on titanium Grade4 and Ti-6Al-7Nb alloy surface. Samples were subjected to surface treatment: mechanical polishing and then SiO2 layer was applied by means of sol-gel method. Evaluation of mechanical properties was realized by the tests of nano-hardness and adhesion of the layer to the substrate. Nano-hardness tests were made with application of Oliver & Pharr method and Berkovich intending tool while adhesion tests were performed with application of scratch test. For the tests Micro-Combi-Tester Open platform was used. The results showed that silicone layer created both on titanium Grade4 and Ti-6Al-7Nb alloy surface features similar mechanical properties. Obtained results show low adhesion of SiO2 layer to the substrate made of titanium Grade 4 and titanium alloy Ti-6Al-7Nb. In both cases there was no acoustic emission signal, which proves low bonding energy between the layer and the substrate.
Źródło:
Engineering of Biomaterials; 2014, 17, 124; 36-41
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modyfikacja wapniem i fosforem warstewki tlenkowej na stopie Ti6Al7Nb
Modification of oxide layer by calcium and phosphorus on Ti6Al7Nb alloy
Autorzy:
Simka, W.
Nawrat, G.
Iwaniak, A
Powiązania:
https://bibliotekanauki.pl/articles/284264.pdf
Data publikacji:
2008
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
Ti6Al7Nb
pasywacja anodowa
modyfikacja
Ti-6Al-7Nb alloy
spark anodization
Ca and P implantation
Opis:
Przeprowadzono badania mające na celu określenie możliwości wbudowania wapnia i fosforu w warstewkę tlenkową na stopie implantacyjnym Ti6Al7Nb w trakcie procesu pasywacji anodowej oraz określenie odporności na korozję tak zmodyfikowanego stopu w fizjologicznym roztworze Tyrode'a. Stwierdzono, że przy napięciu pasywacji wynoszącym U=100V, w warstewkę pasywną wbudowuje się jedynie fosfor. Zastosowanie wyższego napięcia (U=150V) powoduje utlenianie jarzeniowe powierzchni, prowadzące do otrzymania struktury porowatej o zwiększonej zawartości wapnia i fosforu. Proces pasywacji anodowej połączony z implantacją wapnia i fosforu w warstewkę tlenkową powoduje zwiększenie odporności na korozję stopu Ti6Al7Nb w roztworze fizjologicznym Tyrode'a.
The research was undertaken in order to determine the possibility of calcium and phosphorous incorporation into the oxide layer on Ti6Al7Nb implant alloy during anodic passivation process and determine the corrosion resistance of such a modified alloy in the physiological Tyrode's solution. It was stated that at the passivation voltage of U=100V, only phosphorous builds itself into the passive layer. Application of higher voltage (U=150V) causes surface glowing oxidation leading to porous structure of increased calcium and phosphorous content. The anodic passivation process combined with calcium and phosphorous implantation into oxide layer leads to improvement of corrosion resistance of Ti6Al7Nb alloy in the physiological Tyrode's solution.
Źródło:
Engineering of Biomaterials; 2008, 11, no. 81-84; 16-20
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Formation of functional coatings on Ti-6Al-7Nb alloy surface
Autorzy:
Nosol, A.
Simka, W.
Kazek-Kęsik, A.
Powiązania:
https://bibliotekanauki.pl/articles/284582.pdf
Data publikacji:
2017
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
Ti6Al7Nb alloys
anodization
bone tissue
Źródło:
Engineering of Biomaterials; 2017, 20, no. 143 spec. iss.; 82
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of various antibacterial, biodegradable polymeric coatings developed on Ti6Al7Nb surface
Autorzy:
Jaworska, J.
Jelonek, K.
Jaworska, M.
Kajzer, W.
Szewczenko, J.
Pastusiak, M.
Kasperczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/285816.pdf
Data publikacji:
2018
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
polymeric coatings
biodegradable
Ti6Al7Nb alloys
Źródło:
Engineering of Biomaterials; 2018, 21, 148; 31
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ti6Al7Nb alloy surface improvement for implantable blood pumps applications
Autorzy:
Gonsior, M.
Tarnowski, M.
Janiczak, K.
Zawidlak-Węgrzyńska, B.
Wierzchoń, T
Gawlikowski, M.
Kustosz, R.
Powiązania:
https://bibliotekanauki.pl/articles/286034.pdf
Data publikacji:
2017
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
Ti6Al7Nb alloys
blood pump
implantation
Źródło:
Engineering of Biomaterials; 2017, 20, no. 143 spec. iss.; 65
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie własności mechanicznych powłoki polimerowej na podłożu ze stopu Ti6Al7Nb
Mechanical properties of polymer coating on Ti6Al7Nb substrate
Autorzy:
Solarz, J.
Grygiel-Pradelok, M.
Kajzer, W.
Szewczenko, J.
Powiązania:
https://bibliotekanauki.pl/articles/99169.pdf
Data publikacji:
2016
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
PLGA
Ti6Al7Nb
adhezja powłok polimerowych
twardość powłok polimerowych
Ti-6Al-7Nb
polymer coating adhesion
polymer coating hardness
Opis:
W pracy przedstawiono wpływ sposobu modyfikacji powierzchni stopu Ti6Al7Nb na własności mechaniczne naniesionej powłoki biodegradowalnego polimeru poli(D,L-laktyd-ko-glikolid) (PLGA). Zakres badań obejmował: pomiary chropowatości oraz obserwacje makroskopowe powierzchni metalowego podłoża oraz obserwacje powierzchni powłoki polimerowej, badanie adhezji do podłoża oraz ultrananotwardości. Badania wykazały istotny wpływ sposobu modyfikowania powierzchni podłoża ze stopu Ti6Al7Nb na własności mechaniczne powłoki polimeru PLGA.
The study describes results of research influence of methods for modifying the surface of the Ti6Al7Nb alloy on the mechanical properties of the applied coating of biodegradable polymer poli(lactid-co-glicolic acid) (PLGA). The research included: assessment of the macroscopic surface of samples in the initial state and after applied polymer coating, measurements of surface roughness of the metal substrate, scratch test and ultrananohardness test. Research has shown a significant impact of used method of modifying metal substrate on mechanical properties of the PLGA coating. The analysis also showed dependence of adhesion polymer coating on roughness of the metal substrate.
Źródło:
Aktualne Problemy Biomechaniki; 2016, 10; 69-74
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Plasma oxidized Ti6Al4V and Ti6Al7Nb alloys for biomedical applications
Autorzy:
Pązik, B.
Grabarczyk, J.
Batory, D.
Kaczorowski, W.
Burnat, B.
Czerniak-Reczulska, M.
Makówka, M.
Niedzielski, P.
Powiązania:
https://bibliotekanauki.pl/articles/285698.pdf
Data publikacji:
2016
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
Ti6Al4V alloy
Ti-6Al-7Nb alloy
biomaterials
Źródło:
Engineering of Biomaterials; 2016, 19, 138; 68
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ wielokrotnej sterylizacji na właściwości biomateriałów
Influence of the multiple sterilization process on the biomaterial properties
Autorzy:
Bociąga, D.
Jastrzębski, K.
Olejnik, A.
Świątek, L.
Marchwicka, M.
Powiązania:
https://bibliotekanauki.pl/articles/285826.pdf
Data publikacji:
2016
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
Ti6Al4V
Ti6Al7Nb
wielokrotna sterylizacja
chropowatość powierzchni
zwilżalność
biozgodność
Ti-6Al-7Nb
multiple sterilization
surface roughness
wettability
biocompatibility
Opis:
Materiały metaliczne, między innymi stopy tytanu posiadają liczne właściwości, które pozwalają na ich częste stosowanie do produkcji wyrobów biomedycznych. Wszystkie urządzenia przeznaczone do celów medycznych przed użyciem muszą przejść proces sterylizacji. W praktyce niektóre z nich mogą być poddane więcej niż jednemu cyklowi sterylizacji przed umieszczeniem w ciele pacjenta. Pomimo tego, że sterylizacja jest jednym ze standardowych procesów, któremu podlegają wszystkie implanty, może być ona przyczyną zmian właściwości powierzchniowych materiału. Celem niniejszej pracy było sprawdzenie, jak proces wielokrotnej sterylizacji wpływa na właściwości powierzchniowe oraz odpowiedź komórkową dla grupy próbek wykonanych z dwóch stopów tytanu: Ti6Al4V i Ti6Al7Nb. Wypolerowane próbki obu stopów zostały poddane jednemu, pięciu oraz dziesięciu cyklom sterylizacji parowej. Próbki zostały przebadane pod kątem morfologii powierzchni (SEM) oraz składu chemicznego (EDS), a także topografii powierzchni (profilometr) oraz zwilżalności (pomiar kąta zwilżania metodą kropli). Badania cytotoksyczności i proliferacji komórek zostały przeprowadzone poprzez wykonanie testu live/dead z wykorzystaniem komórek kościotwórczych linii Saos-2. Przeprowadzone badania dowodzą, że wielokrotna sterylizacja powoduje pojawianie się zanieczyszczeń na powierzchni materiału oraz zwiększenie grubości warstwy tlenkowej. Wartości energii powierzchniowej oraz parametrów chropowatości wzrosły wraz ze wzrostem liczby cykli sterylizacji. Proliferacja komórek na wysterylizowanych próbkach ze stopów tytanu była mniejsza niż w przypadku stali nierdzewnej oraz próbki kontrolnej, chociaż żadna z próbek nie wykazała cytotoksyczności. Porównując dwa przebadane stopy tytanu, mniejsza proliferacja została odnotowana na próbkach Ti6Al7Nb.
Due to their favorable properties, numerous metallic materials, including titanium alloys are chosen for biomedical applications. A final preparation step before the implantation of a metallic biomaterial is sterilization. In fact, some of the devices may undergo a multiple sterilization process before they are placed into the human body. Although sterilization is a part of a standard procedure, it might affect the surface properties of the material. The purpose of this study was to check the influence of multiple sterilization process on surface properties and biological response of two titanium alloys: Ti6Al4V and Ti6Al7Nb. Samples of both alloys were mechanically polished and subjected to 1, 5 or 10 stem sterilization cycles. Representative samples from each group were examined in term of surface morphology (SEM), chemical composition (EDS), topography (profilometer) and wettability (sessile drop technique). Cell proliferation and cytotoxicity assay were carried out with the use of live/dead test of Saos-2 osteoblast-like cells line. Examinations showed that the multiple sterilization process caused occasional appearance of contaminations on the surfaces, as well as increase in the oxide layer thickness. Values of surface energy and surface roughness parameters increased with the increasing number of sterilization cycles. Proliferation of cells on the surface of sterilized titanium alloys was lower than in the case of stainless steel and control sample. At the same time, none of the examined samples showed cytotoxicity. Comparing two titanium alloys, considerably lower number of cells was observed on Ti6Al7Nb surface.
Źródło:
Engineering of Biomaterials; 2016, 19, 136; 11-20
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies