Tytuł:
The Chronic Dose Assessment of Three Critical Organs for Liver Scintigraphy with Using Cr-51
Autorzy:
Maranci, Ö.
Tugrul, A.
Powiązania:
https://bibliotekanauki.pl/articles/1031760.pdf
Data publikacji:
2017-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
Cr-51
dosimetry
phantom
scintigraphy
TRIGA
Opis:
In this study, a dosimetric study was observed by using Cr-51 gamma radioisotope on liver scintigraphy. In this context, the source organ is determined as liver and it is aimed the evaluation of measuring doses from source organ to selected three critical organs (thyroid, gonad, and brain). An antropomorphic torso phantom has been preferred in the experiments. The measurements of critical organs doses were examined for chronic effects. Moreover, the chronic effect of Cr-51 radioisotope on critical organs was determined as cumulative dose. Thermoluminescent dosimeters were used for chronic dose assessment. In the experiments, lithium fluoride (LiF) (TLD-100) detectors were used and they were provided from Turkish Atomic Energy Authority - Cekmece Nuclear Research and Training Center and calibrated in there. Within this study, the evaluation of the cumulative doses by using Cr-51 for three critical organs was observed with an original setup by using anthropomorphic torso phantom experimentally.
Źródło:
Acta Physica Polonica A; 2017, 132, 3; 476-478
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of Radiological Dose around a 3-MW TRIGA Mark-II Research Reactor
Autorzy:
Rahman, A. F. M. M.
Shamsuzzaman, M.
Rahman, M. S.
Uddin, K.
Yeasmin, S.
Nazmul, Haque H. M.
Akramuzzaman, M. M.
Chakraborty, S. R
Powiązania:
https://bibliotekanauki.pl/articles/412377.pdf
Data publikacji:
2013
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
source term
release rate
TRIGA Mark-II reactor
dispersion
ingestion and deposition of radionuclide
Gaussian plume model
dose calculations
Opis:
A hypothetical accidental case of a 3-MW TRIGA Mark-II research reactor has been assumed to assess the radiological consequences due to the deposition of 137Cs and 90Sr on ground, vegetation, milk and meat. The air concentrations in sixteen cardinal directions have been estimated where the maximum concentration has been found to be at 110 m distance from the core of the reactor for all the directions. Calculated maximum doses of 137Cs, 90Sr and both 137Cs and 90Sr have been found to be within the ranges of 0.005-0.014 μSv hr–1, 0.013-0.036 μSv hr–1 and 0.018-0.05 μSv hr–1, respectively for all the directions, which are below the measured background dose limit 0.25 μSv hr–1 and also within the IAEA acceptable dose rate limit of 0.5 μSv hr–1. The calculated low doses due to the aforementioned radionuclides can be considered negligible with regard to the radiation hazards. The relationship between total effective dose rate for various pathways (i.e. immersion, inhalation, ground deposition, and ingestion of contaminated vegetation, milk, meat) and air concentration in all the directions has been established. Obtained relation reveals that the total effective dose rate is directly proportional to the air concentration, and the overall proportionality constants for 137Cs and 90Sr radionuclides have been obtained as 0.57 and 0.28, respectively. This study might provide information on the radiological safety required for the radiation protection purposes of the people living in the vicinity of the reactor site.
Źródło:
International Letters of Chemistry, Physics and Astronomy; 2013, 10, 2; 183-200
2299-3843
Pojawia się w:
International Letters of Chemistry, Physics and Astronomy
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies