Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "TI" wg kryterium: Temat


Tytuł:
Preparation and Properties of Ti-Y2O3 Composites for Implant Applications
Autorzy:
Adamek, G.
Jakubowicz, J.
Dewidar, M.
Powiązania:
https://bibliotekanauki.pl/articles/353545.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Ti-based composites
yttrium oxide
mechanical alloying
biomaterials
Opis:
The paper presents the preparation of Ti-(1-30wt.%)Y2O3 composites using the mechanical alloying process. Ti based materials are the best metallic biomaterials because of their excellent properties: biocompatibility, low Young moduli and high corrosion resistance. Pure Ti and Y2O3 powders were alloyed under argon atmosphere in shaker type mill (Spex 8000) followed by pressing and sintering. The ultra-low grain size structure improves the mechanical properties and hardness of the new materials in comparison to microcrystalline Ti-based sinters. However, because of the porosity of approx. 20-30%, a decrease in the Young modulus is observed. Moreover, the new composites show good tendency towards covering by Ca-P compounds during soaking in SBF.
Źródło:
Archives of Metallurgy and Materials; 2017, 62, 2A; 663-666
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Właściwości stopu Ti-6Al-4V po modyfikacji powierzchni
Properties of the biofunctionalized surface of Ti-6Al-4V alloy
Autorzy:
Adamek, G.
Jakubowicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/283787.pdf
Data publikacji:
2013
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
Ti6Al4V
odporność korozyjna
wytrzymałość połączenia metal-ceramika
biozgodność
Ti-6Al-4V
corrosion resistance
metallic/ceramic bond strength
biocompatibility
Opis:
W pracy badano właściwości porowatego stopu Ti-6Al-4V istotne z punktu widzenia zastosowań na implanty tkanek twardych. Stop wytworzono za pomocą procesu mechanicznej syntezy, prasowania i spiekania. Modyfikację powierzchni prowadzono dwuetapowo: pierwszym było elektrochemiczne trawienie w 1M H3PO4 + 2% HF w 10 V przez 30 min, a drugim osadzanie ceramiki fosforanowo wapniowej (Ca-P) z wodnego roztworu 0,042M Ca(NO3)2 + 0,025M (NH4)2HPO4 + 0,1M HCl. Jony wapnia i fosforanowe osadzają się w głębi porów, co polepsza wytrzymałość połączenia ceramicznej powłoki z metalicznym podłożem. Wytrzymałość była o ponad 50% większa dla porowatego stopu niż dla litego odpowiednika. Odporność korozyjną badano w roztworze Hanka symulującym środowisko płynów ustrojowych (SBF). Po osadzaniu powłoki Ca-P zaobserwowano niewielką poprawę gęstości prądu korozyjnego w stosunku do próbki polerownej. Zbadano również biozgodność stopu po modyfikacji powierzchni w testach in vitro. Powierzchnia po elektrochemicznej modyfikacji wykazuje dobrą biozgodność, a powłoka Ca-P wspomaga wzrost i proliferację osteoblastów. Ze względu na porowatość, stosunkowo dobrą wytrzymałość połączenia i biokompatybilność powierzchni stop Ti-6Al-4Vpo elektrochemicznej modyfikacji wydaje się być dobrym materiałem na implanty tkanek twardych.
Properties of a porous Ti-6Al-4V alloy, important in hard tissue implants applications, were investigated. The alloy was prepared by mechanical alloying followed by pressing, sintering and subsequent anodic electrochemical etching in 1M H3PO4 + 2% HF elec¬trolyte at 10 V for 30 min and bioactive ceramic Ca-P layer deposition, using a mixture of 0.042M Ca(NO3)2 + 0.025M (NH4)2HPO4 + 0.1M HCl dissolved in distilled water. The Ca2+ and PO43- ions penetrate the pores preferentially inside, which results in improved bonding of the bioceramic layer to the metallic substrate. The bond strength obtained by a tensile test shows more than 50% higher strength to the porous Ti-6Al-4V substrate than to the bulk material. The corrosion resistance of the alloys was investigated in Hank's Balanced Salt Solution (HBSS) which is simulated body fluid (SBF). We observed slight improvement in corrosion current density after etching and additional Ca-P deposition compared to mechanically polished samples. The biocompatibility of the Ti-6Al-4V alloy with a porous Ca-P layer was investigated. We showed that the rough, electrochemically biofunctionalized sur¬face supported osteoblast cell growth and proliferation. Due to rough morphology, relatively strong bonding to the metallic substrate and in vitro biocompatibility the electrochemically modified surface of the ultrafine grained Ti-6Al-4V is promising for hard tissue implant applications.
Źródło:
Engineering of Biomaterials; 2013, 16, 120; 35-40
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Joining of the AMC Composites Reinforced with Ti3Al Intermetallic Particles by Resistance Butt Welding
Autorzy:
Adamiak, M.
Tomiczek, B.
Górka, J.
Czupryński, A.
Powiązania:
https://bibliotekanauki.pl/articles/353835.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
composite materials
intermetallics
Ti3Al
resistance butt welding
mechanical properties
Opis:
The introduction of new reinforcing materials continues to be investigated to improve the final behaviour of AMCs as well as to avoid some drawbacks of using ceramics as reinforcement. The present work investigates the structure, properties and ability of joining aluminium EN-AW 6061 matrix composite materials reinforced with Ti3Al particles by resistance butt welding as well as composite materials produced by mechanical milling, powder metallurgy and hot extrusion techniques. Mechanically milled and extruded composites show finer and better distribution of reinforcement particles, which leads to better mechanical properties of the obtained products. Finer microstructure improves mechanical properties of obtained composites. The hardness increases twice in the case of mechanically milled composites also, a higher reinforcement content results in higher particle dispersion hardening, for 15 wt.% of intermetallics reinforcement concentration composites reach about 400 MPa UTS. Investigation results of joints show that best hardness and tensile properties of joints can be achieved by altering soft conditions of butt welding process e.g. current flow time 1.2 s and current 1400 A. To improve mechanical properties of butt welding joints age hardening techniques can also be used.
Źródło:
Archives of Metallurgy and Materials; 2016, 61, 2A; 847-852
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena akcesji Ukrainy do Unii Europejskiej
Assessment of Ukraines accesion to the European Union
Autorzy:
Adamus, Wiktor
Bobkiewicz, Sebastian
Szewczyk, Jan
Powiązania:
https://bibliotekanauki.pl/articles/2057584.pdf
Data publikacji:
2020-01-17
Wydawca:
Wyższa Szkoła Biznesu i Przedsiębiorczości w Ostrowcu Świętokrzyskim
Tematy:
intеgrаcjа
Ukrаinа
Uniа Еurоpеjskа
kryteria członkostwa
cоnditiоns fоr mеmbеrship
Еurоpеаn Uniоn
intеgrаtiоn
Ukrаinе
Opis:
Cеlеm prаcy jеst оcеnа i аnаlizа prоcеsu intеgrаcji Ukrаiny z UЕ оrаz pеrspеktywy rоzwоju tеj intеgrаcji. Аnаlizа pеrspеktywy rоzwоju intеgrаcji Ukrаiny z UЕ dоtyczy pоtеncjаlnych skutków pоlitycznych, еkоnоmicznych, sоcjаlnych i kulturоwych intеgrаcji еurоpеjskiеj w ujęciu kоrzyści i kоsztów wynikаjących z człоnkоstwа Ukrаiny w UЕ. Z przеprоwаdzоnеj аnаlizy pеrspеktywy człоnkоstwа Ukrаiny w UЕ mоżnа wywniоskоwаć, żе przystępując dо UЕ, Ukrаinа оsiągniе rеlаtywniе więcеj kоrzyści, w tym: kоrzyści pоlitycznе, еkоnоmicznе, spоłеcznе оrаz kulturоwе, wynikаjących z człоnkоstwа Ukrаiny w UЕ. Pоnаdtо аnаlizа pоziоmu pоpаrciа spоłеczеństwа Ukrаińskiеgо dlа intеgrаcji Ukrаiny z UЕ pоzwаlа nа wysunięciе kilku kоnkluzji: przеdе wszystkim pоpаrciе wynоsi оkоłо 50%; nаstrоjе spоłеcznе w tym kоntеkściе są niеstаbilnе i uzаlеżniоnе оd biеżących wydаrzеń pоlitycznych; dоstrzеgаlnе są istоtnе dysprоpоrcjе rеgiоnаlnе w pоstrzеgаniu intеgrаcji Ukrаiny z UЕ; pоziоm pоinfоrmоwаniа оbywаtеli о prоcеsiе i skutkаch intеgrаcji, jаk równiеż pоziоm idеntyfikаcji z Еurоpą jеst niski. Jеdnоczеśniе zаchоwаny jеst pоtеncjаł dо wzrоstu оdsеtkа zwоlеnników intеgrаcji z UЕ, czеgо wаrunkiеm jеst skutеcznа pоlitykа infоrmаcyjnа włаdz pаństwоwych. Nаlеży pоdkrеślić, żе przystąpiеniе Ukrаiny dо Unii niе jеst kwеstią nаjbliższеj przyszłоści, pоniеwаż Ukrаinа niе spеłniа wszystkich krytеriów unijnych. Pоnаdtо Ukrаinа, jаkо krаj wiеlоkulturоwy, znаjdujе się nа styku wpływów dwóch zróżnicоwаnych cywilizаcji (wschоdniеj i zаchоdniеj). Mówiąc о stоsunkаch Ukrаiny z Unią Еurоpеjską niе mоżnа zаpоmniеć о rоli, jаką оdеgrаłа Pоlskа. Jаkо człоnеk UЕ jеst nаjbаrdziеj zааngаżоwаnа wе współprаcę z Ukrаiną (Kijоwеm).
Аim оf this study is аssеssmеnt аnd аnаlysis оf thе prоcеss оf intеgrаtiоn оf Ukrаinе with thе ЕU аnd prоspеcts оf thе dеvеlоpmеnt оf this intеgrаtiоn. Аnаlysis оf dеvеlоpmеnt prоspеcts оf intеgrаtiоn оf Ukrаinе with thе ЕU cоncеrns thе pоtеntiаl еffеcts оf pоliticаl, еcоnоmic, sоciаl аnd culturаl оf Еurоpеаn intеgrаtiоn in tеrms оf bеnеfits and cоsts аrising frоm Ukrаinе's mеmbеrship in thе ЕU. ЕU. Thе аnаlysis оf thе prоspеcts оf intеgrаtiоn оf Ukrаinе with thе ЕU shоws thаt jоining thе ЕU, Ukrаinе rеаch rеlаtivеly mоrе аdvаntаgеs, including thе pоliticаl, еcоnоmic, sоciаl аnd culturаl аspеcts, rеsulting frоm ЕU mеmbеrship fоr Ukrаinе. In аdditiоn, аn аnаlysis оf thе lеvеl оf Ukrаiniаn sоciеty suppоrt оf thе intеgrаtiоn оf Ukrаinе with thе ЕU аllоws tо drаw а fеw cоnclusiоns: first оf аll suppоrt it оscillаtеs аrоund 50%; sоciаl mооds in this cоntеxt аrе unstаblе аnd dеpеnd оn currеnt pоliticаl еvеnts; visiblе аrе significаnt rеgiоnаl dispаritiеs in thе pеrcеptiоn оf intеgrаtiоn оf Ukrаinе with thе ЕU; lеvеl tо infоrm thе public аbоut thе prоcеss аnd cоnsеquеncеs оf intеgrаtiоn, аs wеll аs thе lеvеl оf idеntificаtiоn with Еurоpе is lоw. Аt thе sаmе timе prеsеrvеd is thе pоtеntiаl tо incrеаsе thе pеrcеntаgе оf suppоrtеrs оf intеgrаtiоn with thе ЕU, which prоvidеd аn еffеctivе infоrmаtiоn pоlicy оf thе gоvеrnmеnt. It shоuld bе еmphаsizеd thаt Ukrаinе's аccеssiоn tо thе Uniоn is nоt а mаttеr оf thе nеаr futurе, bеcаusе Ukrаinе dоеs nоt mееt аll thе critеriа оf thе ЕU. Furthеrmоrе, Ukrаinе, аs а multiculturаl cоuntry, is lоcаtеd аt thе junctiоn оf twо divеrsе influеncеs оf civilizаtiоn (Еаst аnd Wеst). Spеаking аbоut Ukrаinе's rеlаtiоns with thе Еurоpеаn Uniоn cаnnоt fоrgеt thе rоlе plаyеd by Pоlаnd. Аs а mеmbеr оf thе ЕU is thе mоst cоmmittеd tо wоrking with Ukraine (Kiеv).
Źródło:
Acta Scientifica Academiae Ostroviensis. Sectio A, Nauki Humanistyczne, Społeczne i Techniczne; 2019, 13-14, 1-2; 169-204
2300-1739
Pojawia się w:
Acta Scientifica Academiae Ostroviensis. Sectio A, Nauki Humanistyczne, Społeczne i Techniczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Distance Education
Kształcenie na odległość
Autorzy:
Afanas, Dorin
Powiązania:
https://bibliotekanauki.pl/articles/2007647.pdf
Data publikacji:
2021
Wydawca:
Uniwersytet Pedagogiczny im. Komisji Edukacji Narodowej w Krakowie. Instytut Spraw Społecznych
Tematy:
distаnсе еduсаtiоn
tyреs оf еduсаtiоn
virtuаl institutiоns
еduсаtiоn
mоdеls
kształcenie na odległość
rodzaje kształcenia
instytucje wirtualne
modele kształcenia
Opis:
Thе соnсерt оf рrераrаtiоn fоr lifе, whiсh hаs lоng bееn а mаjоr gоаl оf еduсаtiоn systеms аrоund thе wоrld, hаs bесоmе rеdundаnt in thе ореn реrsресtivе by thе hugе trаnsfоrmаtiоns in sосiеty, duе tо сhаngеs in tесhnоlоgy аnd есоnоmy. Fifty yеаrs аgо, lifеlоng lеаrning соuld bе sееn аs аn орtiоn fоr аn аgе with mоrе frее timе. Nоw it hаs bесоmе а nесеssity. Thе оffеrs оf еduсаtiоn аnd trаining hаvе bесоmе sеgmеntеd аnd divеrsifiеd, in ассоrdаnсе with thе vаriоus dеmаnds оf соnsumеrs whо раy fоr the еduсаtiоnаl mоdulеs аdjustеd tо thеir оwn nееds. Distаnсе еduсаtiоn is just оnе ехрrеssiоn оf this nеw соnsumеr оriеntаtiоn оf thе vаriоus trаining institutiоns. Ассumulаtiоn оf сrеdits аnd their trаnsfеr, mоdulаrizаtiоn оf соursеs аrе раrt оf thе sаmе struсturаl trаnsfоrmаtiоn оf thе еduсаtiоnаl рrосеss.
Koncepcja przygotowania do życia, która przez długi czas była głównym celem systemów edukacyjnych na całym świecie, stała się zbędna w otwartej perspektywie przez ogromne transformacje w społeczeństwie spowodowane zmianami w technologii i gospodarce. Pięćdziesiąt lat temu uczenie się przez całe życie mogło być postrzegane jako opcja dla osób dysponujących większą ilością wolnego czasu. Teraz stało się ono koniecznością. Oferty edukacyjne i szkoleniowe są dziś segmentowane i zróżnicowane, zgodnie z wymaganiami konsumentów, którzy płacą za moduły edukacyjne dostosowane do ich własnych potrzeb. Kształcenie na odległość jest tylko jednym z przejawów tej nowej orientacji konsumenckiej instytucji szkoleniowych. Akumulacja punktów i transfer, modularyzacja kursów są częścią tej samej strukturalnej transformacji procesu edukacyjnego.
Źródło:
Labor et Educatio; 2021, 9; 67-82
2353-4745
2544-0179
Pojawia się w:
Labor et Educatio
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of PWHT on weld properties of titanium alloy for refurbishment of aircraft engine exhaust cone
Autorzy:
Ardy, H.
Yoewono, S.
Sugianto, A.
Powiązania:
https://bibliotekanauki.pl/articles/248139.pdf
Data publikacji:
2012
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
engine exhaust cone
Ti-6Al-4V
GTAW
PWHT
microstructure
grain size
stress analysis
Opis:
The mounting bolt hole of aircraft engine exhaust cone was found cracked in the weld area. Exhaust cone material is alfa/beta titanium (Ti-6Al-4V) alloy. The cracked section will be repaired by welding to restore its function. The purpose of this research is to evaluate the effect of post weld heat treatment (PWHT) on ductility, grain size, and shear strength of Ti-6Al-4V plates (0.063 in. thickness) welded by gas tungsten arc welding (GTAW) using commercial purity (CP) titanium wire electrode (AMS 4951H). The weld quality was evaluated by non-destructive and destructive tests, using the acceptance criteria of AWS D17.1 and AWS B2.1 as references. The effect of PWHT was examined by preparing two weld specimens: with and without PWHT at 620 centigrade. Non-destructive inspection by dye penetrant and xray radiography tests revealed that the weld in these two specimens is free from surface and internal defects. Weld specimen without PWHT is brittle and failed during fillet break test, whereas PWHT specimen is ductile and pass the same test. Metallography observation was conducted to measured grain size of base metal and heat affected zone (HAZ). The average grain size of PWHT specimen is 18.40 mi m on base metal and 36.80 mi m on HAZ, and for non-PWHT specimen is 26.85 mi m on base metal and 52.10 mi m on HAZ. Using Hall-Petch approach, the yield strength is calculated about 920 MPa on the base metal of PWHT specimen, which result in the shear strength of about 531 MPa. Under static loading, the shear stress on the outer surface of exhaust cone due to exhaust gas is about 38 MPa, which is much lower than material shear strength.
Źródło:
Journal of KONES; 2012, 19, 1; 9-14
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of mechanical strength and corrosion resistance at variable pH of orthodontic wires
Autorzy:
Augustyn-Nadzieja, Joanna
Szczotok, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/1844971.pdf
Data publikacji:
2020
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
tensile test
orthodontic wires
austenitic steel
nitinol (NiTi)
Tiβ
corrosion resistance
Opis:
Orthodontic wires are components of fixed appliances used to perform the necessary tooth movements in the course of the orthodontic treatment. A variety of materials e.g. metals, alloys, polymers and composites are used to produce orthodontic wires. This study examined the mechanical strength and cracks resistance of three different types of wires, i.e. made of: austenitic steel grade AISI 303, NiTi alloy and Tiβ alloy. Corrosion processes are regarded to have a harmful effect on the properties of orthodontic wires, such as their strength, biocompatibility and aesthetic appearance. In this study, we investigated the corrosive behaviour of the wires in the artificial saliva solutions with varied pH simulating the natural oral cavity environment. It was demonstrated that the orthodontic rectangular wires made of austenitic steel grade AISI 303 exhibited the highest tensile strength. The NiTi alloy wires exhibited the best plastic properties of all the examined samples. In the case of electrochemical tests (changes in corrosion potential over a period of 24 h), the wire made of austenitic steel and the NiTi alloy wire reached a stable level of the stationary potential in the acidic environment. For the wires made of Tiβ, the highest stationary potential was observed in the alkaline environment. Additionally, the Tiβ alloy wire revealed the broadest passivation area in the specified potential scope.
Źródło:
Engineering of Biomaterials; 2020, 23, 157; 2-9
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of Fe Content on the Microstructure and Mechanical Properties of Ti-Al-Mo-V-Cr-Fe Alloys
Autorzy:
Bae, K.-C.
Oak, J.-J.
Kim, Y. H.
Park, Y. H.
Powiązania:
https://bibliotekanauki.pl/articles/351896.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Ti alloy
near-β titanium alloy
aircraft applications
structural material
landing gear
Opis:
To investigate the effect of Fe content on the correlation between the microstructure and mechanical properties in near-b titanium alloys, the Ti-5Al-5Mo-5V-1Cr-xFe alloy system has been characterized in this study. As the Fe content increased, the number of nucleation sites and the volume fraction of the α phase decreased. We observed a significant difference in the shape and size of the α phase in the matrix before and after Fe addition. In addition, these morphological deformations were accompanied by a change in the shape of the α phase, which became increasingly discontinuous, and changed into globular-type α phase in the matrix. These phenomena affected the microstructure and mechanical properties of Ti alloys. Specimen #2 exhibited a high ultimate tensile strength (1071 MPa), which decreased with further addition of Fe.
Źródło:
Archives of Metallurgy and Materials; 2017, 62, 2B; 1105-1108
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hydrides precipitation in Ti6Al4V titanium alloy used for airframe manufacturing
Autorzy:
Băilă, D. I.
Tonoiu, S.
Powiązania:
https://bibliotekanauki.pl/articles/200617.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
hydrides precipitation
Ti6Al4V alloy
hydrogen embrittlement
pitting corrosion
wytrącanie wodorków
Stop Ti6Al4V
kruchość wodorowa
korozja wżerowa
Opis:
The aeronautical industry is a sector constantly looking for new materials and equipment because of its tendency to expand quickly. The Ti6Al4V titanium alloy is used frequently in the aeronautic, aerospace, automobile, chemical and medical industry because it presents high strength combined with low density (approximately 4.5 g/cm3), good creep resistance (up to 550°C), excellent corrosion resistance, high flexibility, good fatigue and biocompatibility. As a result of these properties, this titanium alloy is considered an excellent material for manufacturing structural parts in the aircraft industry for modern aeronautic structures, especially for airframes and aero-engines. But its use is also problematic because the Ti6Al4V titanium alloy manifests hydrogen embrittlement, by means of hydrides precipitation in the metal. The Ti6Al4V alloy becomes brittle and fractures because of hydrogen diffusion into metal and because titanium hydrides appear and create pressure from within the metal, thus generating corrosion. Because of titanium hydrides, the titanium alloy suffers from reduced ductility, tensile strength and toughness, which can result in fractures of aeronautical parts. This poses a very serious problem for aircrafts. In this paper, rapid hydrogen embrittlement is presented along with XRD, SEM and TEM analysis. Its goal is to detect the presence of titanium hydrides and to spot the initial cracks in the metallic material.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2019, 67, 3; 643-649
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie wiedzy z zakresu technologii informacyjnej przez absolwentów kierunku ETI w pracy zawodowej
Taking the advantage of knowledge of information technology by graduates of eti during the vocational work
Autorzy:
BAŁAżAK, Marta
Powiązania:
https://bibliotekanauki.pl/articles/456142.pdf
Data publikacji:
2012
Wydawca:
Uniwersytet Rzeszowski
Tematy:
edukacja techniczno-informatyczna
zawód nauczyciela
technologie informacyjne (TI)
technology and computer science education
profession of teacher
information technology (IT)
Opis:
Absolwenci kierunku edukacji techniczno informatycznej pracują w róŜnych zawodach. Nie zawsze jest to praca pedagogiczna w szkole, do której byli przygotowywani. Artykuł dotyczy zastosowania wiedzy z technologii informacyjnej wykorzystywanej w pracy na róŜnych stanowiskach nienauczycielskich.
The graduates of ETI work in various occupations. This isn’t only pedagogical work at school, to that they were prepared. This article relates to application the knowledge of Information Technology which is used during work but not on teachers’ positions.
Źródło:
Edukacja-Technika-Informatyka; 2012, 3, 1; 148-153
2080-9069
Pojawia się w:
Edukacja-Technika-Informatyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Possibilities of applying Ti (C, N) coatings on prosthetic elements : research with the use of human endothelial cells
Autorzy:
Banaszek, K.
Wiktorowska-Owczarek, A.
Kowalczyk, E.
Klimek, L.
Powiązania:
https://bibliotekanauki.pl/articles/306892.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
materiały stomatologiczne
stopy stomatologiczne
węglikoazotki tytanu
powłoka
cellviability
microvascular endothelial cells
Ni-Cr
dental alloys
titanium carbonitride
Ti(C, N)
coating
Opis:
Purpose: The aim of our study was to examine the effect of prosthetic alloys with Ti (C, N) coatings on viability and pro life ration of human cells employing an MTT assay with the use of human microvascular endothelial cells derived from the skin – HMEC-1 (Human Microvascular Endothelial Cells-1). Methods: Cylindrical shape samples made of Ni-Cralloy were divided into S1-S5 groups and coated with Ti (C, N) layers with different content of C and N. S0 group – control group without layer. The alloys (S0-S5) were stored in an experimental medium (MCDB131 with antibiotics) for 30 days and then HMEC-1 cells were incubated in the alloy extract for 24 and 96 hours. Next, cell viability was determined using MTT method. Results: In the case of samples incubated for both 24 and 96 hours there are statistically significant differences (with p-value <0.05) between the uncoated samples (S0 group) and all the other Ti (C, N) coated samples. Higher absorbance values were observed in all coated groups than in the control S0 group, where cell growth was statistically significantly lower. Conclusions: During incubation of endothelial cells with coated samples the number of cells was significantly bigger than the number with uncoated alloys. The best viability of cells was obtained from the S = 3 (with 51.94% at. Ti, 28.22% at. C and 19.84% at. N) group of samples. Ti (C, N) coatings may be applied as protective components on prosthetic elements made of base metal alloys.
Źródło:
Acta of Bioengineering and Biomechanics; 2016, 18, 1; 129-136
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ zawartości węgla i azotu w powłokach Ti(C,N) na ich wybrane właściwości mechaniczne
Effect of carbon and nitrogen content in Ti(C,N) coatings on selected mechanical properties
Autorzy:
Banaszek, K.
Pietnicki, K.
Klimek, L.
Powiązania:
https://bibliotekanauki.pl/articles/211385.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Obróbki Plastycznej
Tematy:
powłoki Ti(C,N)
właściwości mechaniczne
twardość
moduł sprężystości
adhezja
Ti(C,N) layers
mechanical properties
hardness
elastic modulus
adhesion
Opis:
Stopy metali nieszlachetnych stosowane w protetyce i ortodoncji na różnego rodzaju uzupełnienia i aparaty mogą powodować niekorzystne odpowiedzi organizmu. Aby temu zapobiec stosuje się różnego rodzaju modyfikacje warstw wierzchnich oraz pokrycia ochronne. Najczęściej stosowanymi są tlenki, węgliki i azotki metali. Spośród tych ostatnich na szczególną uwagę zasługują węgliki i azotki tytanu, charakteryzujące się dobrymi właściwościami mechanicznymi i dużą odpornością na korozję. Celem niniejszej pracy było zbadanie wybranych właściwości (moduł sprężystości, twardość, przyczepność) powłok Ti(C,N) na stopach protetycznych w zależności od udziału w nich węgla i azotu. Badaniom poddano próbki w kształcie walców ze stopu protetycznego typu Ni-Cr pokrytego powłokami Ti(C,N) o różnej zawartości węgla i azotu w warstwie, poczynając od czystych powłok TiN do czystych TiC. Powłoki osadzano metoda rozpylania magnetronowego. Na tak otrzymanych próbkach wykonano badania twardości i modułu sprężystości metodą nanoindentacji oraz przyczepności zgodnie z normą VDI 3198. W wyniku przeprowadzonych badań stwierdzono, że wzrost zawartości węgla w powłoce Ti(C,N) powoduje zarówno wzrost twardości od 20 GPa (TiN) do 34 GPa (TiC), jak i modułu sprężystości od 272 (TiN) do 382 (TiC). Przyczepność wszystkich badanych powłok do podłoża metalicznego była zadawalająca i mieściła się w klasie HF1 wzorca normy. W żadnym przypadku nie odnotowano delaminacji powłok, a tylko pęknięcia w okolicy odcisku, przy czym widoczne one były dopiero przy dość znacznym powiększeniu (1000x). Podsumowując przeprowadzone badania, można stwierdzić, że powłoki typu Ti(C,N) na protetycznym stopie Ni-Cr są zadowalające z punktu widzenia zastosowania ich jako ochronne na elementach protetycznych i ortodontycznych.
Non-precious metal alloys used in prosthetics and orthodontics for various kinds of restorations and apparatuses can cause disadvantageous responses of the body. In order to prevent this, different surface layer modifications as well as protective coatings are applied. Among the most frequently used, we can name metal oxides, carbides and nitrides, among which titanium carbides and nitrides are especially worth-mentioning, as they characterize in good mechanical properties and high corrosive resistance. The aim of this work was to examine selected properties (modulus of elasticity, hardness, adhesion) of Ti(C,N) coatings applied on prosthetic alloys, depending on the carbon and nitrogen content. The tests involved the use of cylinder-shaped samples made of a Ni-Cr-type prosthetic alloy coated with Ti(C,N) coatings of different carbon and nitrogen contents in the layer, from pure TiN coatings to pure TiC coatings. The coatings were deposited by the magnetronic sputtering method. The samples obtained in this way then underwent hardness and modulus of elasticity tests by the nano-indentation method as well as adhesion tests according to the VDI 3198 standard. The results of the examinations showed that an increase of the carbon content in the Ti(C,N) coating causes an increase of both the hardness, from 20 GPa (TiN) to 34 GPa (TiC), and the modulus of elasticity, from 272 (TiN) to 382 (TiC). The adhesion of all the examined samples to the metal substrate was satisfying and was within the range of the HF1 grade of the standard’s model. None of the cases exhibited coating delamination – only fractures in the vicinity of the indentation, which were visible only at quite a large magnification (1000x). To sum up the performed tests, we can state that Ti(C,N)-type coatings applied on a prosthetic Ni-Cr alloy are satisfying from the point of view of their protective application for prosthetic and orthodontic elements.
Źródło:
Obróbka Plastyczna Metali; 2015, 26, 4; 33-46
0867-2628
Pojawia się w:
Obróbka Plastyczna Metali
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ zawartości węgla i azotu w powłokach Ti(C,N) na ich wybrane właściwości mechaniczne
Effect of carbon and nitrogen content in Ti(C,N) coatings on selected mechanical properties
Autorzy:
Banaszek, K.
Pietnicki, K.
Klimek, L.
Powiązania:
https://bibliotekanauki.pl/articles/211403.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Obróbki Plastycznej
Tematy:
powłoki Ti(C, N)
właściwości mechaniczne
twardość
moduł sprężystości
adhezja
Ti(C,N) layers
mechanical properties
hardness
elastic modulus
adhesion
Opis:
Stopy metali nieszlachetnych stosowane w protetyce i ortodoncji na różnego rodzaju uzupełnienia i aparaty mogą powodować niekorzystne odpowiedzi organizmu. Aby temu zapobiec stosuje się różnego rodzaju modyfikacje warstw wierzchnich oraz pokrycia ochronne. Najczęściej stosowanymi są tlenki, węgliki i azotki metali. Spośród tych ostatnich na szczególną uwagę zasługują węgliki i azotki tytanu, charakteryzujące się dobrymi właściwościami mechanicznymi i dużą odpornością na korozję. Celem niniejszej pracy było zbadanie wybranych właściwości (moduł sprężystości, twardość, przyczepność) powłok Ti(C,N) na stopach protetycznych w zależności od udziału w nich węgla i azotu. Badaniom poddano próbki w kształcie walców ze stopu protetycznego typu Ni-Cr pokrytego powłokami Ti(C,N) o różnej zawartości węgla i azotu w warstwie, poczynając od czystych powłok TiN do czystych TiC. Powłoki osadzano metoda rozpylania magnetronowego. Na tak otrzymanych próbkach wykonano badania twardości i modułu sprężystości metodą nanoindentacji oraz przyczepności zgodnie z normą VDI 3198. W wyniku przeprowadzonych badań stwierdzono, że wzrost zawartości węgla w powłoce Ti(C,N) powoduje zarówno wzrost twardości od 20 GPa (TiN) do 34 GPa (TiC), jak i modułu sprężystości od 272 (TiN) do 382 (TiC). Przyczepność wszystkich badanych powłok do podłoża metalicznego była zadawalająca i mieściła się w klasie HF1 wzorca normy. W żadnym przypadku nie odnotowano delaminacji powłok, a tylko pęknięcia w okolicy odcisku, przy czym widoczne one były dopiero przy dość znacznym powiększeniu (1000x). Podsumowując przeprowadzone badania, można stwierdzić, że powłoki typu Ti(C,N) na protetycznym stopie Ni-Cr są zadowalające z punktu widzenia zastosowania ich jako ochronne na elementach protetycznych i ortodontycznych.
Non-precious metal alloys used in prosthetics and orthodontics for various kinds of restorations and apparatuses can cause disadvantageous responses of the body. In order to prevent this, different surface layer modifications as well as protective coatings are applied. Among the most frequently used, we can name metal oxides, carbides and nitrides, among which titanium carbides and nitrides are especially worth-mentioning, as they characterize in good mechanical properties and high corrosive resistance. The aim of this work was to examine selected properties (modulus of elasticity, hardness, adhesion) of Ti(C,N) coatings applied on prosthetic alloys, depending on the carbon and nitrogen content. The tests involved the use of cylinder-shaped samples made of a Ni-Cr-type prosthetic alloy coated with Ti(C,N) coatings of different carbon and nitrogen contents in the layer, from pure TiN coatings to pure TiC coatings. The coatings were deposited by the magnetronic sputtering method. The samples obtained in this way then underwent hardness and modulus of elasticity tests by the nano-indentation method as well as adhesion tests according to the VDI 3198 standard. The results of the examinations showed that an increase of the carbon content in the Ti(C,N) coating causes an increase of both the hardness, from 20 GPa (TiN) to 34 GPa (TiC), and the modulus of elasticity, from 272 (TiN) to 382 (TiC). The adhesion of all the examined samples to the metal substrate was satisfying and was within the range of the HF1 grade of the standard’s model. None of the cases exhibited coating delamination – only fractures in the vicinity of the indentation, which were visible only at quite a large magnification (1000x). To sum up the performed tests, we can state that Ti(C,N)-type coatings applied on a prosthetic Ni-Cr alloy are satisfying from the point of view of their protective application for prosthetic and orthodontic elements.
Źródło:
Obróbka Plastyczna Metali; 2015, 26, 1; 33-46
0867-2628
Pojawia się w:
Obróbka Plastyczna Metali
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Changes of Toxicity and Biodegrability of Sulfonamides Solutions during Their Photocatalytic Degradation
Zmiany toksyczności i podatności na biodegradację roztworów zawierających sulfonamidy podczas ich degradacji metodą fotokatalityczną
Autorzy:
Baran, W.
Adamek, E.
Makowski, A.
Sochacka, J.
Sobczak, A.
Powiązania:
https://bibliotekanauki.pl/articles/388706.pdf
Data publikacji:
2009
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
sulfonamidy
proces fotokatalityczny
TiO2
biodegradacja
toksyczność
Chlorella vulgaris
sulfonamides
photocatalytic process
Ti02
biodegradation
ecotoxicity
Opis:
The aim of this study was to estimate the applicability of the photocatalytic process to: (1) sulfa-drugs degradation in aqueous solutions, (2) a decrease in their toxicity and (3) an increase in the biodegradability. Photocatalytic process initiated by UV-A radiation was carried out in open reactors containing a catalyst (TiO2 suspension) and solutions of five sulfonamides. After a definite irradiation time the change of sulfa-drugs concentration in solutions was estimated using HPLC method. Moreover, changes of total organic carbon (TOC), chemical oxygen demand (COD), biochemical oxygen demand (BOD5) as well as changes of sulfonamides toxicity relative to Chlorella vulgaris were examined. The biodegradability investigated sulfonamides and their photocatalytic degradation products was determined based on BOD5/COD ratio. It was found that under experimental conditions all investigated sulfonamides underwent the photocatalytic degradation and the decrease in TOC and COD of sulfa-drugs solutions was observed. Simultaneously, products of this process were less toxic and more biodegradable than initial sulfonamides.
Celem badań było określenie możliwości wykorzystania procesu fotokatalitycznego do degradacji leków sulfonamidowych w roztworach wodnych oraz do zmniejszenia ich toksyczności i zwiększenia podatności na biodegradację. Proces fotokatalityczny inicjowany za pomocą promieniowania UV-A oraz światła słonecznego prowadzono w otwartych reaktorach zawierających katalizator (zawiesinę TiO2) oraz roztwory pięciu wybranych sulfonamidów. W roztworach uzyskanych po fotokatalitycznej degradacji oznaczano: stężenie sulfonamidów (metodą HPLC), stężenie ogólnego węgla organicznego (OWO) oraz zmiany chemicznego (ChZT) i 5-dobowego biochemicznego (BZT5) zapotrzebowania na tlen. Ponadto, sulfonamidy i produkty ich fotokatalitycznej degradacji oceniano pod względem ich toksyczności wobec Chlorella vulgaris oraz podatności na biodegradację (BZT5/ChZT). Stwierdzono, że w stosowanych warunkach wszystkie badane sulfonamidy ulegały fotokatalitycznej degradacji ze zmniejszeniem OWO i ChZT roztworów. Jednocześnie produkty tego procesu okazały się mniej toksyczne i bardziej podatne na biodegradację niż wyjściowe sulfonamidy.
Źródło:
Ecological Chemistry and Engineering. A; 2009, 16, 4; 327-336
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microstructure and Properties of YSZ Coatings Prepared by Plasma Spray Physical Vapor Deposition for Biomedical Application
Autorzy:
Barczyk, J.
Dercz, G.
Matuła, I.
Góral, M.
Maszybrocka, J.
Bochenek, D.
Gurdziel, W.
Powiązania:
https://bibliotekanauki.pl/articles/356455.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
PS-PVD method
bioactive coatings
cp-Ti
YSZ
osseointegration
Opis:
This paper presents the study of microstructure and properties of 8 mol% yttrium stabilized zirconia coating fabricated by Plasma Spray Physical Vapor Deposition technique on commercial pure titanium. The coating was characterized by X-ray diffraction, high resolution scanning electron microscope, profilometer, nanoindentation and nanomachining tests. The X-ray phase analysis exhibit the tetragonal Zr0.935 Y0.065O1.968, TiO and α-Ti phases. The Rietveld refinement technique were indicated the changes of crystal structure of the produced coatings. The characteristic structure of columns were observed in High Resolutions Scanning Electron Microscopy. Moreover, the obtained coating had various development of surfaces, thickness was equal to 3.1(1) μm and roughness 0.40(7) μm. Furthermore, the production coatings did not show microcracks, delamination and crumbing. The performed experiment encourages carried out us to tests for osseointegration.
Źródło:
Archives of Metallurgy and Materials; 2019, 64, 2; 779-783
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies