Tytuł:
Predictive regulation of the output voltage of a three-phase two-level voltage inverter with an LC filter
Autorzy:
Behrendt, Zbigniew
Powiązania:
https://bibliotekanauki.pl/articles/135032.pdf
Data publikacji:
2019
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
uninterruptible power supply (UPS)
model predictive control (MPC)
predictive voltage regulator
load current prediction in the time domain
load current prediction in the frequency domain
total harmonic distortion (THD)
Opis:
The article has presented a predictive output voltage regulator of a three-phase two-level voltage inverter with an LC filter with a prediction of the receiver current in the time domain and the frequency domain. Simulations of the operation of the regulator were conducted for a three-phase receiver. The circuit model and simulations of the operation of the predictive voltage regulator were performed in the PSIM program. The algorithm of the predictive regulator was written in the C programming language in the Microsoft Visual Studio compiler and attached to the model performed in the PSIM program by a block that supports the Dynamic-Link Library.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2019, 57 (129); 79-87
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie szeregu Fouriera do określenia dokładności pomiaru zawartości harmonicznych
The application of Fourier series to determine of measuring accuracy of harmonics contents
Autorzy:
Otomański, P.
Powiązania:
https://bibliotekanauki.pl/articles/157870.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
harmoniczne
analizator harmonicznych
współczynnik odkształcenia napięcia THD
szereg Fouriera
harmonics
harmonic analyzer
total harmonic distortion THD
Fourier series
Opis:
Ocena jakości energii elektrycznej w sieciach elektroenergetycznych wykorzystuje zestaw wielkości normatywnych i uzupełniających. Wśród tych wielkości znajdują się dwie miary zawartości harmonicznych w napięciu: widmo amplitudowe, czyli zestaw wartości poszczególnych harmonicznych oraz współczynnik odkształcenia THD. W pracy zaprezentowano przykładowe wyniki badań wybranego analizatora harmonicznych HA-2000 przeprowadzone na zaprojektowanym i wykonanym stanowisku pomiarowym. Prezentowane stanowisko pomiarowe umożliwia zadawanie wybranych sygnałów testowych - funkcji okresowych, pozwalających na ocenę dokładności pomiaru zawartości harmonicznych.
The electric power quality evaluation in electrical power networks is a complex measuring task carried out with the use of a set of standard and complementary quantities. Among these quantities two measures of harmonic contents in voltage can be mentioned: spectrum amplitude and coefficient THD. The paper presents examples of the measurement results of selected harmonic analyser - HA-2000, realized on a design measuring position. The measuring position makes it possible to set selected test signals - periodic functions which enable the evaluation of measuring accuracy of harmonic contents.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 12, 12; 88-90
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A fuzzy logic approach to shunt active power filter and hybrid active power filter
Autorzy:
Sahoo, Nirjharini
Panda, Gayadhar
Subudhi, B. D.
Powiązania:
https://bibliotekanauki.pl/articles/41189662.pdf
Data publikacji:
2023
Wydawca:
Politechnika Warszawska, Instytut Techniki Cieplnej
Tematy:
Index terms
shunt active power filter
hybrid active power filter
hysteresis current controller
total harmonic distortion (THD)
indirect current controller
filtr mocy czynnej
filtr hybrydowy
zniekształcenie harmoniczne
regulator prądu
Opis:
This paper describes a Fuzzy Logic approach to Shunt Active power filter (SAPF) versus Hybrid Active Power Filter (HAPF) using Simulink. Here hysteresis controlled PWM method is applied to the SAPF and HAPF as a current controller and Fuzzy logic controller as a inverter dc voltage controller. To reduce harmonics, Shunt Active Power Filters (SAPFs) are used with various control schemes, but Hybrid Active power filter is a power electronic device which has both the characteristics of passive power filters and active power filters, which helps in cancelation of the harmonics by producing compensating signal. The fuzzy-hysteresis controller is designed and its simulation results are presented for both the filter types, showing acceptable THD results for the word length used in the fixed-point computations involved in the switching sequence generation. The results of the above controller are compared with the Indirect current controller.
Źródło:
Journal of Power Technologies; 2023, 103, 4; 209-217
1425-1353
Pojawia się w:
Journal of Power Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
FPGA implementation of DPWM utility/DG interfaced solar (PV) power converter for green home power supply
Autorzy:
Singh, S. N.
Mishra, S.
Powiązania:
https://bibliotekanauki.pl/articles/229942.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
direct pulse width modulation (DPWM)
total harmonic distortion THD
field SMF: sealed maintenance
free programmable gate array (FPGA)
Opis:
In this paper, utility/DG interfaced DPWM solar (PV) power converter (SPC) has been proposed and developed to meet the growing green energy demand of household applications in a developing country like India. The use of new software based direct PWM strategy (DPWM) in the inverter circuit has resulted in to produce a very near sine-wave, most suitable for various home loads. Simulated results of proposed PWM output wave form and computation of its harmonics content in terms of THD value (upto 5% or even less) using MATLAB software has been reflected in the proposed scheme. The features like an intelligent control action to prevent battery from overcharge or undercharge, higher efficiency (> 90%), generation of grid quality green electricity, sustainability of solar renewable energy sources, cost effective hardware realization with FPGA based VLSI embedded system, shows the superiority of the proposed scheme over conventional power supply systems.
Źródło:
Archives of Control Sciences; 2011, 21, 4; 461-469
1230-2384
Pojawia się w:
Archives of Control Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Harmonic reduction techniques using multi-pulse rectifiers
Metody redukcji wyższych harmonicznych z wykorzystaniem prostowników multipulsowych
Autorzy:
Stawczyk, P.
Powiązania:
https://bibliotekanauki.pl/articles/402226.pdf
Data publikacji:
2013
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
AC/DC converter
power quality
THD (Total Harmonic Distortion)
autotransformer
przekształtnik AC/DC
jakość energii
współczynnik zawartości harmonicznych
autotransformator
Opis:
AC/DC converters generate high harmonic currents and voltages into the power system, which causes a deformation of their shapes and increases active power losses. This article gives short review about basic methods of reduction of higher harmonics in phase currents of AC/DC converters consisting of parallel connected 6-pulse bridges.
Źródło:
Structure and Environment; 2013, 5, 2; 43-47
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies