Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Stopy kobaltu" wg kryterium: Temat


Wyświetlanie 1-13 z 13
Tytuł:
Structure and corrosion resistance of Co-Cr-Mo alloy used in Birmingham Hip Resurfacing system
Autorzy:
Dobruchowska, E.
Paziewska, M.
Przybyl, K.
Reszka, K.
Powiązania:
https://bibliotekanauki.pl/articles/306647.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
stopy kobaltu
stopy chromu
stopy molibdenu
karbid
odporność korozyjna
polaryzacja potencjodynamiczna
stal nierdzewna
stal azotowana
cobalt-chromium-molybdenum alloy
Birmingham Hip Resurfacing
carbide
precipitation
corrosion resistance
potentiodynamic polarisation
nitrided stainless steel
Opis:
The endoprostheses made of cobalt-chromium-molybdenum (Co-Cr-Mo) alloys belong to the group of the most popular metallic implants used for hip joints reconstruction. For such biomaterials, the primary goal is correct and long-term functioning in the aggressive environment of body fluids. Therefore, the purpose of this study was to examine both the morphology and the corrosion resistance of implants made of the cobalt alloy used in Birmingham Hip Resurfacing (BHR) system (Smith & Nephew). For comparative purposes, the electrochemical studies were done for the nitrided stainless steel – Orthinox. Methods: Observations of the microstructure of the investigated material were performed by means of the optical metallographic microscope and the scanning electron microscope. Furthermore, Energy Dispersive X-ray Spectroscopy was used to analyse the chemical composition of the endoprosthesis. Characterisation and evaluation of electrochemical corrosion resistance of the selected alloys were performed by potentiodynamic polarisation tests. Results: The structural studies confirmed that Co-Cr-Mo (BHR system) is characterised by a typical dendritic microstructure with carbide precipitates, mainly M23C6, within the interdendritic areas. Results of the polarisation measurements showed that the investigated cobalt alloy exhibits lower corrosion potential than Orthinox in the utilised environments (3% NaCl, simulated body fluid – Hank’s Body Fluid). Conclusions: However, the high passivation ability of the Co-Cr-Mo alloy, as well as its resistance to the initiation and propagation of localised corrosion processes, indicate that this material is significantly more appropriate for long-term implants.
Źródło:
Acta of Bioengineering and Biomechanics; 2017, 19, 2; 31-39
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on resistance to corrosive wear of dental CoCrMo alloy containing post-production strap
Badanie odporności na zużycie korozyjne stomatologicznego stopu CoCrMo zawierającego złom poprodukcyjny
Autorzy:
Beer-Lech, K.
Surowska, B.
Powiązania:
https://bibliotekanauki.pl/articles/1365888.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
corrosive wear
cobalt alloys
post-production scrap
zużycie korozyjne
stopy kobaltu
złom poprodukcyjny
Opis:
Use of metal base dental prostheses is accompanied by not only wear due to biomechanical loads that occur during the process of chewing, but also by corrosive wear occurring in aggressive oral environment. Corrosive wear of metal elements of prosthesis may result in excluding it from further use by the occurrence of allergic or even carcinogenic reactions in patient, resulting from the release of toxic metal ions into the body. A common practice in prosthetic laboratories used in order to reduce production costs of dental prostheses is using so-called post-production scrap to subsequent castings. This scrap constitute the elements of casting channels, defectively made skeletons of prostheses or metal residues after prosthetic treatment. Use of post-production scrap to manufacture components to fulfill such high performance criteria (presence of complex biomechanical loads), and in particular taking into account the evaluation of biocompatibility, is the subject of discussion not only in the environment of scientists, but also the producers of dental alloys.The aim of the study was to investigate resistance to corrosive wear of dental cobalt alloy containing post-production scrap. The commercial dental alloy Wironit extra-hard with cobalt matrix has been used in this research. The study was based on a conducted polarity by means of potentiodynamic method in a solution of artificial saliva. Tested alloy samples, containing different percentage intake of post-production scrap, were cast by two casting methods - centrifugal and vacuum-pressure. Average values of parameters of Wironit extra – hard alloy resistance to corrosive wear: corrosion potential – Ecor , corrosion current Icor, polarisation resistance Rpol and pitting potential – Epit were determined. In order to assess alloy surface after corrosion microscopic observation was made. The results of research confirm high resistance of alloy to corrosive wear in environment of artificial saliva. Castings made using centrifugal methods provide lower current density in the passive state than those carried out by vacuum – pressure method, which suggests greater durability of passive layer confirmed by analysis of microstructure of samples after corrosion. Determination of correlation between content of post-production scrap and resistance to corrosion is ambiguous.
Eksploatacji stomatologicznych protez na podbudowie metalowej towarzyszy nie tylko zużycie wskutek obciążeń biomechanicznych, występujących podczas procesu żucia, ale również zużycie korozyjne mające miejsce w agresywnym środowisku jamy ustnej. Zużycie korozyjne metalowych elementów protezy skutkować może wyłączeniem jej z dalszego użytkowania wskutek wystąpienia u pacjenta reakcji alergicznych lub nawet kancerogennych, będących rezultatem uwalniania do organizmu toksycznych jonów metali. Częstą praktyką w laboratoriach protetycznych stosowaną w celu obniżania kosztów produkcji protez jest stosowanie tzw. złomu poprodukcyjnego do kolejnych odlewów. Złom ten stanowią elementy kanałów odlewniczych, wadliwie wykonane szkielety protez bądź metalowe pozostałości po obróbce protetycznej. Zastosowanie złomu poprodukcyjnego do wytwarzania elementów mających spełniać tak wysokie kryteria eksploatacyjne (występowanie złożonego stanu obciążeń biomechanicznych), a zwłaszcza biorąc pod uwagę ocenę biokompatybilności otrzymanych wyrobów, jest tematem dyskusyjnym nie tylko w środowisku naukowców, ale również i samych producentów stopów stomatologicznych. Celem pracy było zbadanie odporności na zużycie korozyjne stomatologicznego stopu kobaltu zawierającego złom poprodukcyjny. Do badań zastosowano komercyjny stop stomatologiczny Wironit extra – hard na osnowie kobaltu. Badanie polegało na przeprowadzeniu polaryzacji metodą potencjodynamiczną w środowisku roztworu sztucznej śliny. Próbki stopu poddane badaniu, zawierające różny udział procentowy złomu poprodukcyjnego, odlane zostały dwiema metodami odlewniczymi - odśrodkową i próżniowo-ciśnieniową. Wyznaczono średnie parametrów określających odporność stopu Wironit extra – hard na zużycie korozyjne: potencjał korozji – Ekor, prąd korozji Ikor, opór polaryzacyjny Rpol i potencjał przebicia – Epit. W celu oceny powierzchni stopu po korozji dokonano obserwacji mikroskopowych. Wyniki badań potwierdzają dużą odporność stopu na zużycie korozyjne w środowisku sztucznej śliny. Odlewy wykonane za pomocą metody odśrodkowej cechują się niższą gęstością prądu w stanie pasywnym niż te wykonane metodą próżniowo – ciśnieniową, co sugeruje większą trwałość warstwy pasywnej potwierdzoną analizą mikrostruktury próbek po korozji. Wyznaczenie zależności pomiędzy zawartością złomu poprodukcyjnego a odpornością na korozję jest niejednoznaczne.
Źródło:
Eksploatacja i Niezawodność; 2015, 17, 1; 90-94
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie właściwości mechanicznych i mikrostruktury stomatologicznych stopów kobaltu i niklu po zastosowaniu złomu poprodukcyjnego
Comparison of mechanical properties and microstructure of cobalt and nickel dental alloys after post-production scrap application
Autorzy:
Beer, K.
Walczak, M.
Powiązania:
https://bibliotekanauki.pl/articles/284101.pdf
Data publikacji:
2013
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
stopy kobaltu
stopy niklu
biomateriały
złom poprodukcyjny
twardość
węgliki
cobalt alloys
nickel alloys
biomaterials
post-production scrap
hardness
carbides
Opis:
Celem pracy było dokonanie analizy wpływu ilości materiału przetapianego wtórnie dodanego do fabrycznie nowego stopu na właściwości mechaniczne i mikrostrukturę stopów stomatologicznych CoCrMo oraz NiCrMo. Stopy te wykorzystywane są w stomatologii do wytwarzania podbudów metalowych protez częściowych. Ze względów ekonomicznych większość laboratoriów protetycznych korzysta z tzw. złomu poprodukcyjnego jako części wsadu do kolejnego procesu odlewania protez. Złom ten stanowić mogą metale lub ich stopy, które były już raz użyte w procesie odlewania, jak również pozostałości po obróbce protetycznej. Doniesienia literaturowe wskazują, iż procedura ta może powodować zmianę właściwości mechanicznych i mikrostrukturalnych uzyskanych odlewów i wpływać na końcową jakość wytworzonych protez. Praca ta powstała w odpowiedzi na problem uzyskiwania różnych wyników przez badaczy. Jako próbki do badań zastosowano jednokrotne przetopy stopu kobaltu i niklu o zawartości wyjściowej odpowiednio: 100, 50, 25% stopu fabrycznego oraz technologię odlewania odśrodkowego. Wykonano próbę zginania, pomiar makrotwardości oraz badania mikrostruktury. Dla badanych stopów zaobserwowano zmianę badanych właściwości mechanicznych, w zależności od udziału odpadów poprodukcyjnych. Zidentyfikowano typy faz występujące strukturze badanych stopów.
The aim of this study was to analyze the impact of the amount of remelted material added to the new alloy on mechanical properties and microstructure of CoCrMo and NiCrMo dental alloys. These alloys are used to manufacture the metal partial frameworks of the dental prostheses. For economic reasons, most dental laboratories use a post-production scrap as part of the batch for the next process of casting dentures. This scrap are metals or their alloys, which have already been used once in the casting process, as well as the residues after prosthetic treatment. Literature reports suggest that this procedure affects the mechanical and structural properties and could affect the quality of the final prosthesis. This work was created in response to the problem of getting different results by the researchers. As the test sample disposable cobalt and nickel alloys were used with a starting composition: 100, 50, 25% of the brand new material and centrifugal casting technology was applied. Bending test as well as macrohardness test and microstructural analysis were performed. For tested castings changes of the mechanical properties were noticed depending on the amount of postproduction scrap in castings. The types of phases occurring in the alloys microstructures were also identified.
Źródło:
Engineering of Biomaterials; 2013, 16, 118; 5-11
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microstructure and Functional Properties of Prosthetic Cobalt Alloys CoCrW
Mikrostruktura i właściwości użytkowe protetycznych stopów kobaltu CoCrW
Autorzy:
Nadolski, M.
Golański, G.
Klimas, J.
Szota, M.
Szymański, J.
Powiązania:
https://bibliotekanauki.pl/articles/355916.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cobalt alloy
microstructure
properties
stopy kobaltu
mikrostruktury
właściwości
Opis:
The material subject to investigation was two commercial alloys of cobalt CoCrW (No. 27 and 28) used in prosthodontics. The scope of research included performing an analysis of microstructure and functional properties (microhardness, wear resistance and corrosion resistance), as well as dilatometric tests. The examined alloys were characterized by diverse properties, which was considerably influenced by the morphology of precipitates in these materials. Alloy No. 27 has a higher corrosion resistance, whereas alloy No. 28 shows higher microhardness, better wear resistance and higher coefficient of linear expansion. Lower value of the expansion coefficient indicates less probability of initiation of a crack in the facing ceramic material.
Badaniu poddano dwa komercyjne stopy kobaltu CoCrW (nr 27 i 28) stosowane w protetyce stomatologicznej. Zakres badań obejmował przeprowadzenie analizy mikrostrukturalnej, właściwości użytkowych (mikrotwardość, odporność na ścieranie i odporność korozyjna) oraz badania dylatometryczne. Badane stopy charakteryzowały się zróżnicowanymi właściwościami na co zasadniczy wpływ miała morfologia wydzieleń w tych materiałach. Stop nr 27 posiada wyższą odporność korozyjną natomiast stop nr 28 wykazuje: wyższą mikrotwardość, lepszą odporność na ścieranie oraz niższy współczynnik rozszerzalności liniowej. Niższa wartość współczynnika rozszerzalności liniowej wskazuje na mniejsze prawdopodobieństwo inicjacji pęknięcia licującego materiału ceramicznego.
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 3A; 1999-2003
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of tungsten content on the corrosion resistance of the cobalt base PTA cladding layers
Wpływ zawartości wolframu w stopach kobaltu na odporność korozyjną warstw napawanych plazmowo
Autorzy:
Kończewicz, W.
Smoleńska, H.
Powiązania:
https://bibliotekanauki.pl/articles/243229.pdf
Data publikacji:
2007
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
napawanie plazmowe PTA
stopy kobaltu
korozja gazowa
PTA cladding
cobalt alloy
gaseous corrosion
Opis:
The cobalt base PTA cladding layers which were built up on the exhaust valve head face of the heavy loaded marine diesel engine have been investigated. The layers were produced from three sort of the powders of different tungsten amounts (4.9, 5.3 and 9 wt. %). Multilayer cobalt base clads after turning and grinding underwent the treatment at the high temperature and different aggressive atmospheres. The oxidation at 650 centigrade for 100 hours and corrosion in exhaust gas condition at temperature about 700 centigrade for similar times were investigated. In order to describe the influence of tungsten on clads properties the cross sections microstructures were observed both close to the surface and to the steel/clad interface as clad and after corrosion, the distribution maps of the alloying elements and chemical microanalysis of the different regions and conditions were performed and also micro hardness distributions were made. It was found that different amount of tungsten did not influence significantly on the microstructure neither as clad state nor after corrosion treatment. However the higher tungsten amount resulted in higher hardness of the layer.
Badaniom poddano napawane plazmowo warstwy wytworzone na powierzchni przylgni zaworów wylotowych silnie obciążonych silników Diesla stosowanych w okrętownictwie. Jako materiał do napawania zastosowano trzy rodzaje proszków wykonanych ze stopów na bazie kobaltu i chromu zawierających różne ilości wolframu (4.9, 5.3 i 9% masowych). Wykonane napoiny wielowarstwowe po odpowiednim przygotowaniu poddano działaniu podwyższonej temperatury i środowisk korozyjnych. Badania przeprowadzono w powietrzu - utlenianie w temperaturze 650 C przez 100 godzin i w środowisku spalin w temperaturze ok. 700 C w zbliżonym czasie. Dla określenia wpływu zwartości wolframu na własności warstw napawanych przeprowadzono badania mikrostruktury na przekroju warstw po napawaniu i po korozji, określono mapy rozkładu pierwiastków w strefie przypowierzchniowej napoin w na granicy napina podłoże stalowe, określono składy chemiczne w mikroobszarach w różnych rejonach napoin dla poszczególnych stanów warstwy oraz zmierzono mikrotwardość na przekroju warstwy w różnych stanach. Stwierdzono, że różnice w składzie chemicznym proszków nie wpływają w sposób znaczący na strukturę warstwy ani w stanie wyjściowym ani po korozji w różnych środowiskach gazowych. Natomiast obserwuje się wyższą twardość warstw wykonanych z proszku o wyższej zawartości wolframu.
Źródło:
Journal of KONES; 2007, 14, 2; 247-252
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of recasting on the useful properties CoCrMoW alloy
Wpływ powtórnego przetapiania na właściwości użytkowe stopu CoCrMoW
Autorzy:
Walczak, M.
Pieniak, D.
Niewczas, A. M.
Powiązania:
https://bibliotekanauki.pl/articles/301158.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
stopy kobaltu
trwałość aparatów protetycznych
powtórne przetapianie
cobalt alloys
durability of prosthetic devices
recasting
Opis:
Przetapianie uprzednio odlanego metalu może spowodować zmianę składu chemicznego nowopowstałego materiału, co w końcowym efekcie może oddziaływać na właściwości użytkowestopu stomatologicznego. Do badań zastosowano stop stomatologiczny CoCrMoW o nazwie handlowej Remanium 2001.Przygotowano 3 grupy stopu stomatologicznego przez zmieszanie 50% fabrycznie nowego stopu ze stopem po poprzednim przetopieniu. Grupę pierwszą odlano w 100% z nowego fabrycznie stopu jako grupę kontrolną (R1). Grupa druga (R2) została odlana z mieszaniny jednakowych ilości nowegostopu oraz stopu odlanego tylko raz. Grupa trzecia (R3) zawierała 50% świeżego stopu oraz stopu odlanego 2 razy.Wykonano analizę mikrostrukturalną oraz składu chemicznego, badania XRD, pomiary twardości, badania tribologiczne oraz badania przyczepności wg ISO 9693.Wykazano, że w odlewaniu należy używać nowego materiału a w przypadku wykorzystania materiału wcześniej używanego należy go wymieszać z materiałem nowym.Wykorzystanie procedury przetapiania może obniżyć koszty odlewów CoCrMoW oraz może być bezpieczne w stomatologii.
Recasting of the previously cast metal can change the chemical composition of the newly formed material, which ultimately could affect the properties of a dental alloy. The research used a dental alloy CoCrMoW trade name Remanium 2001. Three groups of dental alloy were prepared by mixing 50% fresh alloy to alloy remnants from previous castings. The specimens in the first casting group used 100% fresh alloy and served as control (R1). The second group consisted of equal amounts of fresh alloy and alloy remnants cast only once (R2). The third group contained 50% fresh alloy and alloy cast twice (R3). Microstructural analysis was performed and the chemical composition, XRD studies, hardness, and tribological test and the metal–ceramic bond strength was investigated according to ISO9693 standard. New material should be used in casting, and if previously casted material is used, it should be mixed with new material. The use of the recasting procedure can lower the costs of CoCrMoW castings and can be safely in dentistry.
Źródło:
Eksploatacja i Niezawodność; 2014, 16, 2; 330-336
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Corrosion Resistance of Co-Cr-Mo Alloy Used in Dentistry
Odporność korozyjna stopu Co-Cr-Mo wykorzystywanego w stomatologii
Autorzy:
Łukaszczyk, A.
Augustyn-Pieniążek, J.
Powiązania:
https://bibliotekanauki.pl/articles/353547.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cobalt alloys
corrosion resistance
method of wasted wax
microstructure
stopy kobaltu
odporność na korozję
metoda traconego wosku
mikrostruktura
Opis:
The presented paper studies the effect of the casting technology on the corrosion resistance of Co-Cr-Mo alloy. The investigations were conducted on a commercial alloy with the brand name ARGELOY N.P SPECIAL (Co-Cr-Mo) produced by Argen as well as the same alloy melted and cast by the lost wax casting method performed by a dental technician. The corrosion behavior of the dental alloys in an artificial saliva was studied with the use of the following electrochemical techniques: open circuit potential and voltammetry. After the electrochemical tests, studies of the surface of the examined alloys were performed by means of a scanning electron microscope with an X-ray microanalyzer. The results of the electrochemical studies show that the dependence of the corrosion resistance on the microstructure associated with the recasting process is marginal. The results of the electrochemical studies of the considered alloy clearly point to their good corrosion resistance in the discussed environment.
Zbadano wpływ technologii odlewania na odporność korozyjną stopu Co-Cr-Mo. Badaniom poddano stop komercyjny o nazwie handlowej ARGELOY N.P SPECIAL (Co-Cr-Mo) firmy Argen oraz ten sam stop przetopiony i odlany przez technika dentystycznego metodą traconego wosku. Zachowanie korozyjne badanego stopu w środowisku sztucznej śliny zostało zbadane przy użyciu technik elektrochemicznych: pomiaru potencjału bezprądowego, woltamperometrii cyklicznej. Po przeprowadzeniu badań elektrochemicznych wykonano badania powierzchni badanego stopu przy pomocy elektronowego mikroskopu skaningowego z mikroanalizatorem rentgenowskim. Wyniki badań elektrochemicznych wskazują, że na odporność korozyjną oraz mikrostrukturę stopu proces powtórnego odlania wpływa jedynie w niewielkim stopniu. Wyniki badań elektrochemicznych rozpatrywanego stopu wskazują jednoznacznie na ich dobrą odporność korozyjną w rozpatrywanym środowisku.
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 1; 523-528
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Corrosion Resistance and Microstructure of Recasting Cobalt Alloys Used in Dental Prosthetics
Autorzy:
Loch, J.
Krzykała, A.
Łukaszczyk, A.
Augustyn-Pieniążek, J.
Powiązania:
https://bibliotekanauki.pl/articles/380935.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
investment casting technology
ceramic moulds
dental prosthetics
cobalt alloys
corrosion resistance
technologia odlewania
formy ceramiczne
protetyka stomatologiczna
stopy kobaltu
odporność na korozję
Opis:
The work presents the results of the studies of Co-Cr-Mo casting alloys used in the production of frame casts of removable dentures, crowns and bridges in dental prosthetics. The studies were performed on four Co-Cr-Mo alloys of different contents of Mo, W and other additives. Electrochemical tests were performed, which aimed at examining the corrosion resistance of the alloys and observing the alloy structure after chronoamperometric tests with the potential in the area of the occurrence of the passive layer breakpoint. The alloy microstructure images after chronoamperometric tests show the presence of non-uniformly distributed general corrosion. Moreover, a project of cobalt alloy casting was elaborated using a ceramic mold casting. Additionally, analysis of the obtained microstructure was performed. The microstructure of the examined alloys was of the dendrite type. This microstructure was chemically inhomogeneous and consisted of an austenitic matrix formed by a solid cobalt solution and chromium in the core dendritic structure.
Źródło:
Archives of Foundry Engineering; 2017, 17, 2; 63-68
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania tribologiczne stopów kobaltu stosowanych jako biomateriały
Tribological research of cobalt alloys used as biomaterials
Autorzy:
Karpiński, R.
Walczak, M.
Śliwa, J.
Powiązania:
https://bibliotekanauki.pl/articles/101804.pdf
Data publikacji:
2015
Wydawca:
Politechnika Lubelska. Polskie Towarzystwo Promocji Wiedzy
Tematy:
stopy kobaltu
biomateriały
tribologia
cobalt alloys
biomaterials
tribology
Opis:
Poniższe opracowanie zawiera informacje dotyczące stopów kobaltu stosowanych w stomatologii oraz medycynie. Praca zawiera przegląd literatury opisujący ogólne właściwości stopów kobaltu. Opisano także wpływ warunków wytwarzania i wykorzystywanych dodatków stopowych na strukturę oraz właściwości mechaniczne tych stopów. W opracowaniu umieszczona została metodyka przeprowadzonych badań oraz uzyskane wyniki. Do badań wybrane zostały dwa stopy na osnowie kobaltu Co-CrMo-W oraz Co-Cr-Ni-Mo. Pierwszy z nich wytworzony został techniką odlewniczą drugi natomiast wyniku obróbki plastycznej. Przeprowadzona została analiza składu chemicznego, a następnie badania tribologiczne in vitro zrealizowane na tribotesterze typu „ball-on-disc”. Przedstawiona została porównawcza charakterystyka tribologiczna tych stopów.
This study provides information about the cobalt alloys used in dentistry and medicine. The work includes a review of the literature describing the general properties of cobalt alloys. In addition it describes the impact of the manufacturing conditions and alloy additives used , on the structure and mechanical properties of these alloys. The research methodology and the results obtained has been presented in the study. Two cobalt-based alloys Co-CrMo-W and Co-Cr-Ni-Mo were selected for the tests. The first one was prepared with the use of casting technique whereas the second was obtained due to plastic forming. An analysis of the chemical composition and in vitro tribological tests with the use of tribotester of "ball-on-disc" type was conducted. Comparative tribological characteristics of these alloys has been presented.
Źródło:
Journal of Technology and Exploitation in Mechanical Engineering; 2015, 1, 1-2; 17-32
2451-148X
Pojawia się w:
Journal of Technology and Exploitation in Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania materiałowe i korozyjne konwencjonalnych stopów Co-Cr-Mo-W przeznaczonych na odlewy konstrukcji szkieletowych w protetyce dentystycznej
Material and corrosion studies of conventional Co-Cr-Mo-W alloys for frame construction casts in dental prosthetics
Autorzy:
Augustyn-Pieniążek, J.
Łukaszczyk, A.
Loch, J.
Powiązania:
https://bibliotekanauki.pl/articles/285880.pdf
Data publikacji:
2015
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
konwencjonalne stopy na osnowie kobaltu
protetyka dentystyczna
roztwór sztucznej śliny
odporność korozyjna
woltamperometria liniowa
conventional cobalt-based alloys
dental prosthetics
artificial saliva solution
corrosion resistance
linear sweep voltammetry
Opis:
Podstawowe cechy jakimi powinny charakteryzować się materiały stosowane na protezy szkieletowe w stomatologii to biotolerancja w środowisku tkanek i płynów ustrojowych oraz duża odporność na korozję wżerową i szczelinową. Ważna jest również stabilność zespołu określonych własności fizyczno-mechanicznych (wysoka wytrzymałość, odpowiednia ciągliwość, twardość i odporność na ścieranie) oraz jednorodność składu chemicznego W pracy przedstawiono wyniki badań konwencjonalnych stopów odlewniczych Co-Cr-Mo-W stosowanych do wykonywania odlewów szkieletów protez ruchomych, koron i mostów w protetyce dentystycznej. Badania wykonano na czterech stopach Co-Cr-Mo-W o różnej zawartości Mo, W oraz innych domieszek. W pracy dokonano analizy mikrostruktury stopów z zastosowaniem mikroskopu świetlnego oraz elektronowego mikroskopu skaningowego. Dodatkowo wykonano pomiary mikrotwardości metodą Vickersa oraz badania odporności korozyjnej. Dla każdego z badanych stopów Co-Cr-Mo-W wykreślono zależność potencjału stacjonarnego w funkcji czasu oraz wykonano badania woltamperometryczne w środowisku sztucznej śliny. Przeprowadzone obserwacje metalograficzne pozwoliły stwierdzić, że analizowane materiały charakteryzowały się budową dendrytyczną typową dla stopów odlewanych. Mikrostruktura ta jest chemicznie niejednorodna, złożona z austenitycznej osnowy składającej się z roztworu stałego kobaltu oraz chromu w rdzeniowej strukturze dendrytycznej. Stopy charakteryzowały się wysoką twardością. Wzrost mikrotwardości jest silnie determinowany występowaniem wydzieleń węglikowych M23C6, które zapewniają dużo silniejsze umocnienie stopu. Analizowane stopy wykazywały zbliżone przebiegi krzywych polaryzacji. Zachowanie elektrochemiczne stopów Co-Cr-Mo-W w dużej mierze zależy od zawartości w stopie chromu i molibdenu, pierwiastków, które przyczyniają się do pasywacji stopów.
The basic characteristics of skeletal prosthetic materials used in dentistry are: biotolerance with tissues and body fluids, as well as high pitting and crevice corrosion resistance. Also important are such characteristics as: high strength, adequate ductility, hardness and abrasion resistance, as well as homogeneity of the chemical composition. The work presents the results of the studies of conventional Co-Cr-Mo-W casting alloys used in the production of frame casts of removable dentures, crowns and bridges in dental prosthetics. The studies were performed on four Co-Cr-Mo-W alloys of different contents of Mo, W and other additives. The work analyzes the alloys microstructures with the use of a light microscope and a scanning electron microscope. Additionally, hardness measurements were made by means of the Vickers method and corrosion resistance tests were conducted. For each examined Co-Cr-Mo-W alloy, the open circuit potential as a function of time was determined and voltamperometric tests were performed in artificial saliva. The microstructure of the examined alloys was of the dendrite type. This microstructure was chemically inhomogeneous and consisted of an austenitic matrix formed by a solid cobalt solution and chromium in the core dendritic structure. The investigated alloys were characterized by high hardness. The increase in the microhardness was depended on the presence of carbide precipitates M23C6, which provide a much stronger reinforcement of the alloy. The analyzed materials exhibited a similar progress of the polarization curves. The electrochemical corrosion of Co-Cr-Mo-W alloys was depended on the content of chromium and molybdenum, which largely contributed to alloy passivation.
Źródło:
Engineering of Biomaterials; 2015, 18, 130; 2-9
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu zewnętrznego pola magnetycznego na zmianę właściwości magnetycznych stopu Co-Cr-Ni
The analysis of influence of magnetic field on change of magnetic properties of Co-Cr-Ni alloy
Autorzy:
Błaszczak, M.
Powiązania:
https://bibliotekanauki.pl/articles/395465.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
biomateriały
stopy kobaltu
właściwości magnetyczne
biomaterials
melts of cobalt
magnetic proprieties
Opis:
W części analitycznej artykułu przedstawiono podstawy teoretyczne wyjaśniające wpływ budowy wewnętrznej biomateriałów na bazie kobaltu na zmianę własności magnetycznych. Szczególny nacisk położono na analizę struktury domenowej jako cechy mającej istotny wpływ na zachowanie się biomateriałów w silnym zewnętrznym polu magnetycznym. W części badawczej przedstawiono wyniki pomiarów koercji z których wynika że materiał ten znajduje się na pograniczu diamagnetyzmu i paramagnetyzmu.
Theoretical basis explaining the influence of internal structure of biomaterials based on cobalt on the change of magnetic properties were introduced in the analytic part of the article. The special emphasis was placed on the analysis of the domain structure as the attribute essentially influencing the behavior of biomaterials in strong external magnetic field. The results of the measurements of coercive force, Curi temperature and magnetic susceptibility which prove that the investigated material can be placed on the borderland between diamagnetism and paramagnetism were presented in research part of paper.
Źródło:
Postępy Nauki i Techniki; 2011, 10; 49-60
2080-4075
Pojawia się w:
Postępy Nauki i Techniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A quality assessment of casting dental prosthesis elements
Ocena jakościowa odlewanych elementów protetycznych
Autorzy:
Beer, K.
Pałka, K.
Surowska, B.
Walczak, M.
Powiązania:
https://bibliotekanauki.pl/articles/1366170.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
trwałość aparatów protetycznych
wady odlewnicze
stopy kobaltu
durability of prosthetic devices
casting defects
cobalt alloys
Opis:
Properties of fixed and mobile dentures, as well as their design have a significant impact on their durability in a complex state of biomechanical loads that occur in the oral cavity during the chewing process. Elements that are usually mechanical damaged (cracking) in skeletal prostheses are metal clamps. Damage of fixation of dentures not only results in the inability to further operation, but also is causing discomfort in the patient and can lead to injury of the oral cavity, teeth and risk of complications in case of access into the digestive system.The aim of this study was to evaluate the quality of items of prostheses manufactured using available techniques and the analysis of the causes of premature loss of functional quality of these elements. Dental cobalt matrix alloy - Wironit Extra-hard was used for the study. Qualitative research consisted of the evaluation of the nature and intensity of internal casting defects and evaluation of macro-and microstructure of manufactured castings using microscopic techniques. Research of breakthroughs indicate the occurrence of casting shrinkages. Microstructural research revealed the presence of a typical dendritic structure of the matrix in form of solid solution Co-Cr-Mo and eutectic. Strength test results achieved in the relation to the macro and microstructure were also carried out. A quantitative assessment of the intensity of casting defects using image analysis was realized. Potential risks of casting technology were identified and a methodology of monitoring the state of elements of dentures was proposed.
Właściwości stosowanych uzupełnień protetycznych stałych i ruchomych oraz ich konstrukcja mają istotny wpływ na ich trwałość w warunkach złożonego stanu obciążeń biomechanicznych, jakie występują w jamie ustnej w trakcie procesu żucia. Elementami, które najczęściej ulegają uszkodzeniom mechanicznym (pękaniu) w protezach szkieletowych są metalowe klamry. Uszkodzenie mocowania protezy skutkuje nie tylko brakiem możliwości jej dalszej eksploatacji, ale również jest przyczyną uczucia dyskomfortu dla pacjenta i może powodować skaleczenia jamy ustnej, uszkodzenia zębów oraz ryzyko powikłań w przypadku przedostania się do układu pokarmowego. Celem pracy była ocena jakościowa elementów protez wytwarzanych dostępnymi technikami oraz analiza przyczyn przedwczesnej utraty funkcjonalności tych elementów. Do badań zastosowano stop stomatologiczny na osnowie kobaltu Wironit Extra-hard. Badania jakościowe polegały na ocenie rodzaju i nasilenia wewnętrznych wad odlewniczych oraz ocenie makro- i mikrostruktury wytworzonych odlewów z wykorzystaniem technik mikroskopowych. Badania przełomów wskazują na występowanie rzadzizn spowodowanych skurczem odlewniczym. Badania mikrostrukturalne wykazały obecność typowej struktury dendrytycznej z osnową w postaci roztworu stałego Co-Cr-Mo i eutektyką. Wykonano również analizę wyników badań wytrzymałościowych w powiązaniu z uzyskiwaną makro i mikrostrukturą. Dokonano oceny ilościowej nasilenia wad odlewniczych wykorzystując analizę obrazu. Wskazano potencjalne zagrożenia technologii odlewania oraz zaproponowano metodykę monitorowania stanu elementów protez.
Źródło:
Eksploatacja i Niezawodność; 2013, 15, 3; 230-236
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-13 z 13

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies