Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Staw kolanowy" wg kryterium: Temat


Tytuł:
The maximum principle of Pontryagin in control of twolegged robot based on human walking system
Autorzy:
Żur, K. K.
Powiązania:
https://bibliotekanauki.pl/articles/955163.pdf
Data publikacji:
2014
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
staw kolanowy
mięśnie stawu kolanowego
cykl Hamiltona
state equations
maximum principle
optimal conditions
discrete Hamilton function
Opis:
In the paper a hypothesis about state equations of human gait is presented. Instantaneous normalized power developed by human muscles at particular joints of a leg is a control vector in state equations of the human walking system. The maximum principle of Pontryagin in analysis of dynamic human knee joint was presented. The discrete Hamilton function of a knee joint is similar to a discrete square function of normalized power developed by muscles at the knee joint. The results satisfy optimal conditions and could be applied in control of exoskeleton and DAR type robot.
Źródło:
International Journal of Applied Mechanics and Engineering; 2014, 19, 2; 407-417
1734-4492
2353-9003
Pojawia się w:
International Journal of Applied Mechanics and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effectiveness of deep transverse friction massage for the treatment of medial meniscotibial ligament injury in a female football player: a case study
Skuteczność głębokiego masażu poprzecznego w leczeniu uszkodzenia więzadła łąkotkowo-piszczelowego przyśrodkowego u zawodniczki piłki nożnej: studium przypadku
Autorzy:
Zaworski, K.
Powiązania:
https://bibliotekanauki.pl/articles/2048964.pdf
Data publikacji:
2020
Wydawca:
Akademia Bialska Nauk Stosowanych im. Jana Pawła II w Białej Podlaskiej
Tematy:
knee joint
massage
ligament
meniscotibial ligament
injury
staw kolanowy
masaż
więzadło
więzadło łąkotkowo-piszczelowe
uraz
Opis:
Background. The injury to medial meniscotibial ligament (MTL) is a cause of pain in the medial articulatio genus which is rarely discussed in the literature. The paper examines the effectiveness of deep transverse friction massage (DTFM) in the treatment of injury to the medial meniscus-tibial ligament in a female football player. Material and methods. A case study concerned a patient ( 22 years old) who is a football player on the position of striker. She has been complaining about the pain in the right, medial articulatio genus for five days. Deep transverse friction massage (DTFM) was applied in the treatment. A total of 9 procedures was conducted (3 times a week) throughout three weeks. The first DTFM session lasted 2 minutes and the time was systematically extended during further sessions until it reached 15 minutes. Visual Analogue Scale (VAS), modified Laitinen Pain Questionnaire and countermovement jump test (CMJ) on the dynamometric platform were applied to evaluate the effectiveness of the treatment. Results. Having completed the treatment, a decrease of pain measured by the means of VAS and Laitinen Pain Questionnaire was reported. There was also improvement in limb symmetry index in all phases of the test carried out on the dynamometric platform. Conclusions. The results demonstrate that DTFM may be an effective method of treatment for MTL injuries. Conducting further research on a bigger study group is necessary.
Wprowadzenie. Rzadko opisywaną w literaturze przyczyną bólu strony przyśrodkowej stawu kolanowego jest uszkodzenie więzadła łąkotkowo-piszczelowego przyśrodkowego (MTL). Celem artykułu jest przedstawienie skuteczność głębokiego masażu poprzecznego (GMP) w leczeniu uszkodzenia więzadła łąkotkowo-piszczelowego przyśrodkowego u zawodniczki piłki nożnej. Materiał i metody. Studium przypadku dotyczyło pacjentki (22 lata) będącej zawodniczką piłki nożnej na pozycji napastniczki. Od pięciu dni skarżyła się na ból przyśrodkowej strony stawu kolanowego prawego. W leczeniu wykorzystano głęboki masaż poprzeczny (GMP). Łącznie wykonano 9 zabiegów (3 razy w tygodniu) przez okres trzech tygodni. Czas GMP w trakcie pierwszej sesji wynosił 2 minuty i był systematycznie wydłużany w trakcie kolejnych spotkań do 15 min. Do oceny skuteczności zastosowanej metody wykorzystano skalę VAS, zmodyfikowany kwestionariusz Laitinena oraz test skoku pionowego (CMJ) na platformie dynamometrycznej. Wyniki. Po zakończeniu leczenia odnotowano spadek dolegliwości bólowych mierzony za pomocą VAS i kwestionariusza Laitinena oraz poprawę wskaźnika symetryczności we wszystkich fazach testu przeprowadzonego na platformie dynamometrycznej. Wnioski. Uzyskane wyniki w badaniach własnych wskazują, że GMP może być skuteczną metodą leczenia uszkodzeń MTL. Istnieje potrzeba prowadzenia dalszych badań na większej grupie badanej.
Źródło:
Health Problems of Civilization; 2020, 14, 2; 141-147
2353-6942
2354-0265
Pojawia się w:
Health Problems of Civilization
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the accuracy of the postural stability measurement with the Y-Balance Test based on the levels of the biomechanical parameters
Autorzy:
Walaszek, R.
Chwała, W.
Walaszek, K.
Burdacki, M.
Błaszczuk, J.
Powiązania:
https://bibliotekanauki.pl/articles/306519.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
biomechanika
staw kolanowy
stabilność postawy
testy
biomechanics
motor control
postural stability
Y-Balance Test
structure test
Opis:
The testing of dynamic balance involves tests that assess the muscle control of spatial changes of the position of the centre of gravity over the base of support. The purpose of this work was to determine the structure of the Y-balance test and its accuracy based on the measurements of strength performance of the muscles acting on the knee joint, as well as the flexibility and balance in boys aged 14 years. Methods: The study included 43 schoolboys regularly participating in physical education lessons. The examination of postural stability was conducted with the use of the Y-balance test. The measurements of muscle strength and of resistance to fatigue of the extensors and flexors of knee joints in isometric contraction were performed on a measurement stand in a standard position with the use of tensometric sensors. The measurement of mobility range of the lower extremity joints was performed according to the SFTR. The examination of balance was performed with the use of the modified ‘Flamingo balance test’. Results: The factor structure of the Y-balance test results for the left and right lower extremities is similar and includes five principal independent factors that characterise the structure of analysed variables. They explain 76% and 74% of communality in total for the left and the right extremity, respectively. Conclusions: The extracted factor structure points to a hybrid structure of the Y-balance test and shows its accuracy in the measurements of the lower limb joint mobility and strength performance of knee joint extensors.
Źródło:
Acta of Bioengineering and Biomechanics; 2017, 19, 2; 121-128
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluating measurement accuracy and repeatability with a new device that records spatial knee movement
Autorzy:
Tian, Fei
Huang, Qiuyue
Zheng, Zhi
Li, Ningwei
Zhu, Ting
Dai, Wei
Wang, Shaobai
Powiązania:
https://bibliotekanauki.pl/articles/27324129.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
gait analysis
repeatability
motion analysis
three-dimensional
knee joint
analiza chodu
powtarzalność
analiza ruchu
trójwymiarowy
staw kolanowy
Opis:
Purpose: A novel portable system has been used to evaluate spatial knee movement, but its accuracy and repeatability is not known. The aim of this study was to investigate the accuracy and repeatability of the measurement. Methods: Ten healthy participants were included, and the knee motion trajectory during walking were assessed. Six evaluations were conducted (three days by two raters) for each participant. The motion parameters at the key points and the range of motion were statistically analyzed. Intraclass correlation coefficients (ICC), standard error of the measurement (SEM), and the Bland–Altman method were used. Results: For intra-rater repeatability, 1) the ICC values range from 0.75 to 0.9 for rotations; and 0.64 to 0.96 for translations. Among the ICC values, 100% of rotations and 90% of translations were not less than 0.70; 2) among the SEM values, 100% of rotations were not more than 5°, while 73.3% of translations were less than 3 mm. For inter-rater repeatability, 1) the ICC values range from 0.68 to 0.99 for rotations; and 0.57 to 0.93 for translations. Among the ICC values, 95.6% of rotations and 82.2% of translations were not less than 0.70; 2) among the SEM values, 100% of rotations were not more than 5°, and 48.9% of translations were less than 3 mm. The Bland–Altman plots showed good agreement for intra- and inter-repeatability. Conclusions: The results indicated that the accuracy and repeatability of the measurement were acceptable, except for the inter-rater repeatability for translation. This may help researchers and physicians better interpret the measurement data.
Źródło:
Acta of Bioengineering and Biomechanics; 2020, 22, 3; 55--67
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wytrzymałościowa endoprotezy stawu kolanowego
Strength analysis of total knee prosthesis
Autorzy:
Tejszerska, D
Długoszewski, T.
Gąsiorek, D
Powiązania:
https://bibliotekanauki.pl/articles/99077.pdf
Data publikacji:
2010
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
analiza wytrzymałościowa
endoproteza
staw kolanowy
ANSYS
strength analysis
endoprosthesis
knee joint
Opis:
W artykule przedstawiono analizę wytrzymałościową endoprotezy stawu kolanowego z wyłączeniem elementu udowego dla kilku wariantów obciążenia. Analiza ta pozwala na obserwację wpływu obciążenia na stan naprężeń i odkształceń w kości i endoprotezie. Model i jego analizę przeprowadzono metodą elementów skończonych w programie Ansys Workbench.
Numerical strength analysis of total knee prosthesis without femur element for few variants of load was presented in this paper. This analysis allow us observe the influence of load on the state of stress and strain in tibia bone and prosthesis . The model and its finite element analysis was performed in ANSYS Workbench.
Źródło:
Aktualne Problemy Biomechaniki; 2010, 4; 213-218
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Poziom rozwijanego statycznego momentu siły a wysokość skoku CMJ studentów AWF we Wrocławiu
The level of the static moment of force and cmj height of university school of physical education students
Autorzy:
Struzik, A.
Pietraszewski, B.
Powiązania:
https://bibliotekanauki.pl/articles/99255.pdf
Data publikacji:
2010
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
moment siły
staw kolanowy
własności biomechaniczne
moment of force
knee joint
biomechanical properties
Opis:
W pracy poszukiwano związku między statycznym momentem siły prostowników i zginaczy stawu kolanowego (sumy prostowników i sumy zginaczy) a wysokością skoku CMJ. Rejestracji sił reakcji podłoża dokonano używając platformy dynamometrycznej firmy Kistler i oprogramowania BioWare. Badania przeprowadzono na grupie 30 studentów IV roku AWF we Wrocławiu w Pracowni Analiz Biomechanicznych. Badanymi były osoby uprawiające sport wyczynowo od minimum 5 lat. Badania miały na celu ocenę własności biomechanicznych (mierzonych w działaniach statycznych i dynamicznych) kończyn dolnych człowieka.
The purpose of the research was to determine the relationship between the static moment of force of knee joint flexors and extensors (sum of flexors and sum of extensors) and the height of CMJ jump. Dynamometric Kistler plate and BioWare software were applied to record the ground reaction force. 30 University School of Physical Education students participated in the study. The research was conducted in the Laboratory of Biomechanical Analysis in Wroclaw. Subjects have been performing professional sport no less than 5 years. The purpose of the research was to assess the biomechanical properties of the lower limbs (measured during static and dynamic exercises).
Źródło:
Aktualne Problemy Biomechaniki; 2010, 4; 179-184
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ratios of torques of antagonist muscle groups in female soccer players
Autorzy:
Struzik, A.
Siemieński, A.
Bober, T.
Pietraszewski, B.
Powiązania:
https://bibliotekanauki.pl/articles/307148.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
staw kolanowy
asymetria
ścięgna
asymmetry
knee joint
hamstring-to-quadriceps ratio
Opis:
An increase in the value of the hamstring-to-quadriceps (H/Q) ratio with an increase in angular velocity may effectively prevent injuries of the back of the thigh. Previous studies have found that the conventional H/Q ratio was unaltered along with an increasing angular velocity in females. Therefore, this study aimed to investigate the relationships between the conventional H/Q ratio and angular velocity in a group of female soccer players. Methods: The study was carried out on a group of 16 female soccer players (age: 20.7 ± 3.9 years, body height: 166.1 ± 5.8 cm, body mass: 58.4 ± 6.2 kg, training experience: 8.8 ± 4.1 years). Measurements of peak torque of extensors and flexors of the knee joint under static conditions and under isokinetic conditions (at angular velocities of 30°/s, 60°/s, 90°/s and 120°/s) were carried out using a Biodex dynamometer. Results: There was a statistically significant increase in the conventional H/Q ratio with an increase in angular velocity. These differences occurred between measurements at angular velocities of 0°/s and 30°/s, and 30°/s and 60°/s. Conclusions: As previously found for males, an increase in conventional H/Q ratio with increased angular velocity was also present in this group of female players. This phenomenon should reduce the number of injuries of the muscles of back of the thigh. Coaches should pay attention to increasing the level of strength in the group of knee joint flexor muscles so as to make the value of the H/Q ratio appropriately high and increasing with increasing angular velocity.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 1; 153-158
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of fatigue loads of the knee joint during gait
Autorzy:
Stępniewski, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/306291.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
staw kolanowy
chód
kości
zmiany strukturalne
knee joint
support phase
gait
accumulation of lesions
structural changes in the bone
Opis:
The aim of the work was to show that the fatigue load of bone tissue causes permanent structural changes in it. Methods: On the basis of the movie recording of gait, the time courses of angular changes in the joints of the lower limb were determined. Using the method of transforming Denavit–Hartenberg coordinate systems, the course of force loading the hip joint and, after that, the course of normal contact reaction of the femoral head of the knee joint during gait for the support phase were determined. On the basis of the Hertz formula, the course of contact stresses in the femoral joint head and the damage coefficient were determined according to the Palmgren–Miner damage accumulation hypothesis. Results: A calculation example was made using own software. The course of the obtained damage factor was compared to the image fixed in the X-ray image after its appropriate processing. The thesis of the work has been confirmed to a satisfactory degree. Conclusions: The nature of the lesions is similar to the image of structural changes in the head of the joint. It should be assumed that the image fixed in the bone is the result of the stored history of loads. Analysis of the obtained image can be used to determine the state of bone strength.
Źródło:
Acta of Bioengineering and Biomechanics; 2019, 21, 3; 159-167
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza geometryczna i ruchowa stawu kolanowego człowieka
Geometrical and mobility analysis of knee joint of man
Autorzy:
Stępniewski, A. A.
Powiązania:
https://bibliotekanauki.pl/articles/972139.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
analiza strukturalna
analiza kinematyczna
staw kolanowy
structural analysis
kinematical analysis
knee joint
Opis:
W pracy przeprowadzono analizę strukturalną i geometryczno-ruchową płaskiego modelu stawu kolanowego. Wyznaczono ruchliwość i zidentyfikowano więzy bierne. Określono podstawowe wymiary, konieczne do opisania geometrii stawu. Do analizy ruchowej przyjęto uproszczony model płaski. Wykorzystując przekształcenia układów współrzędnych Denavita-Hartenberga, wyznaczono wektory położeń charakterystycznych punktów kości udowej względem kości piszczelowej. Wyznaczono linię styku kości piszczelowej z udową dla pełnego zakresu ruchu w stawie. Opracowano algorytm wyznaczania współrzędnych położenia punktu przytwierdzenia więzadeł pobocznych do kości udowej dla zadanego położenia punktu przytwierdzenia względem kości piszczelowej. Zamieszczono przykład obliczeniowy będący ilustracją omówionego algorytmu.
The paper presents the structural, geometric and mobility analysis of flat mechanism of the knee joint model. The mobility was determined and passive bonds were identified. The basic dimensions, necessary for description of the joint geometry, were defined. The simplified flat model was assumed for the mobility analysis. Using the transformation of Denavit-Hartenberg systems of coordinates, vectors of position of the femoral bone characteristic points in relation to the tibial bone were determined. The shape of the tibial bone pan assuring solid contact of the bone during full range of movement in the joint was defined. There was worked out an algorithm for determining the position coordinates of the point of attaching marginal ligaments to the femoral bone for the given position of the attaching point in relation to the tibial bone. The example of computations illustrating the algorithm discussed is presented in the paper. It can be stated that in the joint flat model there appear three passive fetters: the point of the bone junction, two marginal ligaments along with the kinematic pair. The relative movement along circle of marginal ligaments ends is loaded with the radial error equal to 0,7 mm.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 6, 6; 342-345
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza strukturalna, geometryczna i statyczna mechanizmu stawu kolanowego
Analysis of structural, geometrical and static of knee-joint mechanism
Autorzy:
Stępniewski, A.
Powiązania:
https://bibliotekanauki.pl/articles/386350.pdf
Data publikacji:
2010
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
staw kolanowy
biomechanika
analiza strukturalna
knee joint
biomechanics
structural analysis
Opis:
W pracy przeprowadzono analizę strukturalną, geometryczną i statyczną mechanizmu wzorowanego na budowie stawu kolanowego człowieka. Wyznaczono ruchliwość, zidentyfikowano więzy bierne i sklasyfikowano mechanizm stawu. Określono podstawowe wymiary, konieczne do opisania geometrii stawu. Do analizy przyjęto uproszczony model płaski. Wykorzystując przekształcenia układów współrzędnych Denavita-Hartenberga, wyznaczono wektory położeń charakterystycznych punktów kości udowej i rzepki względem kości piszczelowej. Wyznaczono obciążenia elementów stawu. Zamieszczono przykład obliczeniowy będący ilustracją omówionego algorytmu obliczeniowego.
This article shows structural, geometrical and static analysis of the knee-joint. Mobility was determined and passive bonds were identified. The basic dimensions were defined, neces- sary for description of geometry of joint. Simplified flat model was accepted for mobility analysis. Using the transformation of arrangement co-ordinate Denavit-Hartenberg, vectors of sites characteristic of bones of femoral bone, according to tibial bone were defined. Loads of elements of the pond were set. Computational being example was put illustration of discussed algorithm.
Źródło:
Acta Mechanica et Automatica; 2010, 4, 1; 80-85
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efekty usprawniania pacjentów po endoprotezoplastyce stawu kolanowego w zależności od typu zastosowanego implantu
Results of physiotherapeutic treatment of patients after knee-joint endoprothesoplastic burgery depending on the type of the implant
Autorzy:
Skiba, M.
Skiba, G.
Czerner, M.
Króliński, J.
Powiązania:
https://bibliotekanauki.pl/articles/261141.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
staw kolanowy
zmiany zwyrodnieniowe
endoprotezoplastyka całkowita stawu kolanowego
endopimplanty jedno- i wieloosiowe
fizjoterapia
zakres ruchomości
knee
arthrosis
total knee arthroplasty
single- and multi-axis implants
physiotherapy
range of motion
Opis:
Endoprotezoplastyka jest obecnie podstawową metodą leczenia osób z zaawansowanymi zmianami zwyrodnieniowymi stawu kolanowego. Głównym celem zabiegu jest redukcja dolegliwości bólowych, poprawa zakresu ruchomości oraz przywrócenie stabilności stawu, co ma doprowadzić do polepszenia jakości życia chorych. Celem pracy była ocena efektów usprawniania pacjentów po wszczepieniu jedno- lub wieloosiowej endoprotezy stawu kolanowego. Badaniem objęto grupę 60 osób (45 kobiet i 15 mężczyzn) z zaawansowaną gonartrozą. Średnia wieku wynosiła 66,4 lata. 30 pacjentom wszczepiono jednoosiową endoprotezę SCORPIO CR a pozostałym 30 pacjentom endoprotezę wieloosiową PFC SIGMA. We wszystkich przypadkach zachowano więzadło krzyżowe tylne PCL (ang. Posterior Cruciate Ligament). Program leczenia usprawniającego we wczesnym okresie pooperacyjnym był taki sam u wszystkich chorych. Po około 3 miesiącach od zabiegu pacjenci byli usprawniani na Oddziale Rehabilitacji Narządu Ruchu przez okres 3 tygodni, korzystając z odpowiednio dobranego programu kinezy- i hydroterapii. Oceny zakresu ruchomości stawu kolanowego dokonano przed zabiegiem operacyjnym oraz po zakończeniu rehabilitacji. Wyniki wskazują na poprawę zakresu zgięcia oraz wyprostu operowanego stawu, zarówno u pacjentów z jedno-, jak i wieloosiowym implantem.
Total arthroplasty is currently the main treatment of patients with advanced knee degeneration. The basic goal of the surgery is to reduce pain, improve range of motion (ROM), restore join stability, what can lead to the improved quality of life.The aim of this study was to examine the effects of rehabilitation of patients after single- or multi-axis total knee arthroplasty (TKA). The research was performed on a group of 60 people (45 women and 15 men) with advanced gonarthrosis (mean age 66,4 years). In 30 patients single-axis SCORPIO CR prostheses and in 30 multi-axis PFC Sigma prostheses, were implanted. In all cases the posterior cruciate ligament (PCL) has been retained. Physical therapy in the immediate postoperative period was the same in all groups. The patients were exposed to kinesi- and hydrotherapy 3 months after surgery. The functional status of the knee before surgery and after rehabilitation, were evalutaed. It was stated that the knee flexion and extension were improved. There was no significant difference between these 2 groups.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2013, 19, 2; 104-107
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of measurement position on brachial–ankle pulse wave velocity
Autorzy:
Shimawaki, S.
Toda, M.
Nakabayashi, M.
Sakai, N.
Powiązania:
https://bibliotekanauki.pl/articles/306488.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
postawa ciała
prędkość
sztywność
staw kolanowy
posture
pulse wave velocity
vascular stiffness
knee flexion angle
Opis:
Arterial stiffness measurements are primarily used for the early detection of arteriosclerosis. Methods and devices that can easily measure arterial stiffness at home are in demand. We propose a simple method for measuring brachial–ankle pulse wave velocity (baPWV) at home using a reclining chair and investigate the effects of positioning on baPWV measurement. We measured baPWV in 50 healthy men (21–70 years) in seven different measurement positions, including the supine position, sitting, sitting with the knees flexed at 45°, sitting with the knees flexed at 0°, reclining at 37°, reclining at 50°, and standing. BaPWV was significantly lower in the supine position (P < 0.01) than in the other positions. It was significantly higher in the sitting position (P < 0.01) than in the reclining position (37°). No changes in baPWV were seen changing the knee flexion angle alone while sitting. Strong correlations were also observed between baPWV in the supine position and that in other positions. We showed that baPWV in the supine position can be calculated by making corrections to baPWV measured in the sitting position at a reclining angle. Utilizing this corrected value would allow easy measurement at home using a reclining chair.
Źródło:
Acta of Bioengineering and Biomechanics; 2015, 17, 1; 111-116
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microscopic tribological analysis of the knee joint
Mikroskopowa analiza tribologiczna w stawie kolanowym
Autorzy:
Ryniewicz, A. M.
Ryniewicz, A.
Pukaluk, A.
Pałka, P.
Powiązania:
https://bibliotekanauki.pl/articles/188937.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
knee joint
meniscus
articular cartilage
SEM
AFM
staw kolanowy
łąkotka
chrząstka stawowa
Opis:
The aim of the conducted research was the evaluation of the topography and the structure of the superficial layer of meniscus and articular cartilage. These are surfaces that optimise the friction and lubrication process in the knee joint. The animal samples of the menisci and the articular cartilage were examined. The research was performed using scanning electron microscopes and an atomic force microscope. The structure of the surface of meniscus and articular cartilage is very regular. The collagenous fibres, which are embedded in the ground substance, are parallel to the surface. The undulation of the surface was observed. In the area of the anterior horn on tibia side of both menisci as well as in the anterior area of tibial plateau, the concavity and convexity pattern is evident. The observed cavities enable the accumulation of the synovial fluid. The synovial fluid plays the role of the lubricant in the knee joint, and its presence is highly desired during the load transmission.
Celem przeprowadzonych badań była ocena topografii i struktury łąkotek oraz powierzchni stawowych, które zabezpieczają i optymalizują proces tarcia i smarowania w stawie kolanowym. Materiałem badań były łąkotki pobrane z prawidłowych stawów zwierzęcych oraz tkanka chrzęstna wypreparowana z powierzchni stawowych. Badania były realizowane na mikroskopach skaningowych oraz mikroskopie sił atomowych. Struktura warstwy wierzchniej chrząstki włóknistej oraz szklistej wykazała dużą regularność. Włókna kolagenowe biegnące równolegle do powierzchni i zatopione w substancji podstawnej tworzą łagodnie pofalowaną strukturę. Układ wgłębień i wzniesień jest najbardziej wyraźny na części przedniej plateau kości piszczelowej oraz w obszarze rogu przedniego łąkotek, po stronie kontaktującej się z plateau kości piszczelowej. W zaobserwowanych wgłębieniach może gromadzić się ciecz synowialna, która pełni rolę środka smarnego, i której obecność jest wysoce pożądana podczas przenoszenia obciążeń wewnątrz stawu kolanowego.
Źródło:
Tribologia; 2017, 273, 3; 147-154
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary parametrów morfologiczno-czynnościowych stawu kolanowego z wykorzystaniem obrazowania rezonansem magnetycznym
Measurements of morphological and functional parameters of the knee joint using magnetic resonance imaging
Autorzy:
Ryniewicz, A.
Ryniewicz, A. M.
Sładek, J.
Knapik, R.
Powiązania:
https://bibliotekanauki.pl/articles/157400.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
staw kolanowy
parametry morfologiczno-czynnościowe
identyfikacja kształtu
rezonans magnetyczny
chrząstka stawowa
knee joint
morphological and functional parameters
shape identification
magnetic resonance
joint cartilage
Opis:
Celem była identyfikacja kształtu i położenia struktur stawu kolanowego obrazowanego rezonansem magnetycznym (MR) w stabilizowanej pozycji, w aspekcie rozkładu grubości chrząstki stawowej. Badano prawidłowe stawy kolanowe. Obrazowanie przeprowadzono przy wykorzystaniu aparatu MR typu otwartego ze stabilizatorem kąta zgięcia kolana w przekrojach strzałkowych, czołowych i horyzontalnych, w wybranych pozycjach kątowych. Pomiary chrząstki budującej powierzchnie stawowe stawu kolanowego wykazały znaczne zróżnicowanie jej grubości oraz pofalowania z charakterystycznym przesunięciem fali.
The aim of the study was to use the MRI to identify the shape and position of the structures of knee joints in a stabilized position, in terms of the analysis of joint cartilage thickness on femoral condyles, tibia condyles and the patella. There were studied normal knee joints. Imaging was performed with use of an open-type gradient coil MR apparatus with a knee bending angle stabilizer. The research strategy consisted of imaging: sagittal sections in a fixed position of the femoral bone relative to tibia, in selected sagittal sections for stabilized position of the femur relative to tibia for angles ranged from -10 degrees to 50 degrees, at 5 degree intervals, in the frontal sections with physiological extension, in the horizontal sections with physiological extension. Based on the MR imaging, there was measured the distribution of the thickness of joint cartilage that covered the femoral condyles, condyles of tibia and patella. The measurements of the cartilage building the surfaces of the knee joint showed significant variation in its thickness and folds with a characteristic wavelength shift in the tested sections. Variable thickness and uneven structures can substantially affect the conditions of joint lubrication and transfer of the locomotive load. Introduction of the stabilized position of the femur relative to tibia to the MR imaging allows useful identification of particular cartilage layers that work together.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 3, 3; 200-203
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Return of TKA knee arthroplasty patients to driving a car. Comparative systematics
Powrót pacjentów po endoprotezoplastyce stawu kolanowego TKA do prowadzenia samochodu. Systematyka porównawcza
Autorzy:
Pawłowska, Justyna
Gądek, Artur
Wodka-Natkaniec, Ewa
Powiązania:
https://bibliotekanauki.pl/articles/2152189.pdf
Data publikacji:
2021-05-05
Wydawca:
Fundacja Edukacji Medycznej, Promocji Zdrowia, Sztuki i Kultury Ars Medica
Tematy:
arthroplasty
knee joint
driving a car
rehabilitation
alloplastyka
staw kolanowy
powadzenie samochodu
rehabilitacja
Opis:
Background. Despite the availability of numerous articles and analyses carried out in many healthcare centres, there is still no specific guidelines for both orthopaedic surgeons, and physical therapists for patients preparation after total knee arthroplasty to return to driving a car. The influence of many factors should be taken into account, such as: the operated side, the pain associated with the injury and surgery, the lack of sufficient force to slow down in extreme conditions, the patient’s reaction time and the lack of self-confidence when making such an important decision. Both the patient and the doctor who decides to let the patient drive a car must be aware that this is a very complex and responsible action. This may have an impact on the safety of the patient himself as well as other road users. The aim of the study was to analyse the research carried out so far and to help doctors and physiotherapists in taking the decision of returning the patient to driving a car. Most of the available studies are based on driving simulators and automatic gearboxes where a safe braking element is achieved in three to six weeks, where left-sided TKA patients can return to driving after 4 weeks. The most promising research seems to be in real driving, which allows them to return to driving just 3 weeks after the procedure. Material and metods. The medical databases, i.e. PubMed and Medline were searched for articles concerning the studied issue. The search have covered all databases until April 2020. Most of the work presented is based on a 1994 study and article made by Spalding, who was the first who conduct a study concerning the return of TKA patients to driving. Results and Conclusions. Safe, possible return to driving in patients after TKA is possible 6 weeks after the procedure.
Wstęp. Pomimo dostępnych w bazach bibliograficznych artykułów i prowadzonych analizach, w dalszym ciągu nie ma konkretnych wytycznych zarówno dla lekarzy ortopedów, jak i fizjoterapeutów, kiedy pacjent po endoprotezoplastyce stawu kolanowego (TKA) może wrócić do prowadzenia samochodu. Wpływ wielu czynników takich jak: strona operowana, dolegliwości bólowe, brak odpowiedniej siły potrzebnej do wyhamowania w warunkach ekstremalnych, czas reakcji pacjenta czy brak pewności siebie muszą być wzięte pod uwagę przy podejmowaniu tak ważnej decyzji. Zarówno pacjent, jak i lekarz podejmując decyzję o powrocie pacjenta do prowadzenia samochodu musi mieć świadomość, że jest to czynność złożona i odpowiedzialna, gdyż od niej może zależeć bezpieczeństwo pacjenta, jak i innych uczestników drogi. Celem pracy była analiza przeprowadzonych do tej pory badań i pomoc lekarzom oraz fizjoterapeutom w odpowiedzi pacjentowi na to pytanie. Większość dostępnych badań opiera się na symulatorach jazdy i automatycznych skrzyniach biegu, w których bezpieczny element hamowania jest osiągnięty w 3-6 tygodniu, gdzie pacjenci po lewostronnej TKA mogą wrócić do prowadzenia pojazdu po 4 tygodniach. Najbardziej obiecujące wydają się badania w jeździe rzeczywistej, która pozwala na powrót do jazdy już po 3 tygodniach od zabiegu. Materiał i metody. Poprzez medyczne bazy danych tj., PubMed i Medline wyselekcjonowano artykuły dotyczące badanego zagadnienia. Zakres wyszukiwania obejmował całość baz danych do kwietnia 2020 roku. Większość przedstawionych prac opiera się na badaniach i artykule Spaldinga z 1994 roku, który jako pierwszy przeprowadził badania dotyczące powrotu pacjentów po TKA do prowadzenia samochodu. Wyniki i Wnioski. Bezpieczny, możliwy powrót do powadzenia samochodu u pacjentów po TKA jest możliwy po 6 tygodniu od zabiegu.
Źródło:
Polish Journal of Sports Medicine; 2021, 37(1); 23-28
1232-406X
2084-431X
Pojawia się w:
Polish Journal of Sports Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies