Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Sludge" wg kryterium: Temat


Tytuł:
Sludge as an agent improving soil properties
Autorzy:
Bartkowska, I
Powiązania:
https://bibliotekanauki.pl/articles/125365.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
sludge
digestion of sludge
sanitation of sludge
natural utilization of sludge
agent improving properties of sludge
Opis:
Sewage-treatment plants generate sludge which needs to be neutralized for legal, esthetical, and practical reasons. Economical and ecological concerns indicate that sludge, as long as it is possible, should be returned to the natural environment. The article presents the process of autothermal thermophilic aerobic digestion (ATAD) as a measure to produce biomass, which can be naturally utilized. The description of theoretical principles of the process in question is accompanied by presentation of an ATAD installation which has been functioning since 2009 at the municipal sewagetreatment plant in Olecko. Results of microbiological and chemical tests carried out in the years 2010–2012 have been analyzed. Examinations embraced sludge which was the final product of the aforementioned sewage-treatment plant.
Źródło:
Journal of Ecological Engineering; 2013, 14, 2; 63-67
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of metal content in sewage sludge and sewage sludge ash to find opportunities to use them in the construction industry
Autorzy:
Świerczek, Lesław
Cieślik, Bartłomiej
Powiązania:
https://bibliotekanauki.pl/articles/1163144.pdf
Data publikacji:
2018
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
heavy metals
sewage sludge
sewage sludge ash
sewage sludge management
Opis:
Sewage sludge management is becoming an increasing problem in developed and developing countries. Due to their physicochemical properties (mainly high content of heavy metals) a safe method of utilization is sought. Considering environmental protection, energy recycling, reduction in use of the raw materials and the possibility of immobilization hazardous substances, the use of ashes in building materials becomes a very good way of utilization. Both unprocessed sewage sludge and ashes after their thermal utilization can be used in the construction industry. Before using sediments and ashes, it is necessary to analyze the content of heavy metals, because they can have a negative effect, for example, on cement-stabilized products. The purpose of this work was to determine selected metals (Cd, Cu, Ni, Pb, Zn, Cr, Mg, Mn, Fe) in the primary, dehydrated, digested, excess sludge and ash after his incineration to check and compare heavy metal content. The obtained data can be used to optimize the production process of cement products that contain sewage sludge at differ form, and confirm the environmental safety of proposed approaches.
Źródło:
World Scientific News; 2018, 110; 227-235
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Techniczne i ekonomiczne rozwiązania gospodarki osadami w oczyszczalniach komunalnych
Technical and economical solution in sewage sludge management of the municipal wastewater treatment plants
Autorzy:
Pasterak, N.
Mrowiec, B. M.
Powiązania:
https://bibliotekanauki.pl/articles/400328.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
osady ściekowe
przeróbka osadów
gospodarka osadami
ilość osadów
jakość osadów
sewage sludge
sludge disposal
sludge management
quantity sludge
quality sludge
Opis:
W pracy zaprezentowano porównanie prowadzonej gospodarki osadami ściekowymi w 6 oczyszczalniach ścieków komunalnych o RLM od 50 000 do 400 000. Dla prowadzonej oceny istotnymi zagadnieniami były ilość i jakość oczyszczanych ścieków, funkcjonujący ciąg technologiczny przeróbki osadów, ilość i jakość produkowanych osadów oraz ich ostateczne zagospodarowanie. Znaczącym elementem oceny było również działanie w zakresie wprowadzania nowoczesnych technologii w aspekcie ograniczenia składowania osadów.
The paper presents a comparison of realized wastewater sludge disposal processes in six municipal wastewater treatment plants with a pe of 50 000 to 400 000. For that evaluation, quantity and quality of raw wastewater, functioning line of sludge disposal, the quantity and quality of the produced sludge and their utilization were the important issues. A significant element of the assessment was also action in introducing modern technologies in the aspect of reducing the sludge storage.
Źródło:
Inżynieria Ekologiczna; 2015, 43; 7-14
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Drop in Conductivity of Sewage Sludge in the Process of Autothermal Thermophilic Aerobic Digestion
Autorzy:
Bartkowska, I.
Powiązania:
https://bibliotekanauki.pl/articles/123193.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
autothermal stabilization of sewage sludge
conductivity of sewage sludge
neutralization of sewage sludge
sanitation of sewage sludge
sewage sludge processing
Opis:
The article presents research on the assessment of electrolytic conductivity changes of sludge during the process of its autothermal thermophilic aerobic digestion (ATAD), which takes place in a two-stage installation system, operating in a municipal sewage-treatment plant. In the years 2012–2014 sludge was studied and the results were analyzed. Thickened sludge in the intermediate tank, which was then directed to installation reactors, was examined. Conductivity was measured in each tank. In this manner collected results made it possible to follow the changes of this index at consecutive stages of the system. The results were statistically analyzed and it was determined to what degree, as a result of an objective process, the values of processed sludge conductivity would change. The conclusions from the carried-out studies and from own experiments are also presented.
Źródło:
Journal of Ecological Engineering; 2017, 18, 4; 67-75
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of the excess sludge pretreatment on biogas productivity
Autorzy:
Bernat, Katarzyna
Zielińska, Magdalena
Kulikowska, Dorota
Cydzik-Kwiatkowska, Agnieszka
Wojnowska-Baryła, Irena
Waszczyłko-Miłkowska, Beata
Piotrowicz, Beata
Powiązania:
https://bibliotekanauki.pl/articles/298334.pdf
Data publikacji:
2019
Wydawca:
Uniwersytet Warmińsko-Mazurski w Olsztynie
Tematy:
biogas production
sludge pretreatment
activated sludge
aerobic granular sludge
ultrasound disintegration
homogenization
Opis:
To intensify biogas production during anaerobic stabilization of organic matter in sludge, pretreatment is applied. The effect of pretreatment of excess activated sludge (AS) and excess aerobic granular sludge (GS) on biogas productivity (BP) and composition was investigated. The sludge was pretreated with homogenization (6,500 rpm for 0.5 min (H0.5) and 1 min (H1.0)) or ultrasound disintegration at 20 kHz (50% amplitude for 2 min (D50%_2.0) and 4 min (D50%_4.0), and 100% amplitude for 4 min (D100%_4.0)). BP of AS of GS without pretreatment was 603.3±5 dm3/kg TS (793.4±7 dm3/kg VS); that was 200.6±4 dm3/kg TS (480.8±6 dm3/kg VS). With disintegration, the BP of AS increased by 7.8% (650.4±10 dm3/kg TS) (D50%_2.0) and 16.1% (700.6±11 dm3/kg TS) (D100%_4.0), and that of GS increased by 7.0% (214.0±5 dm3/kg TS) (D50%_2.0) and 16.0% (232.8±5 dm3/kg TS) (D100%_4.0). With homogenization, BP increased by 2.0-3.0% (AS) and 1.6-3.2% (GS).
Źródło:
Technical Sciences / University of Warmia and Mazury in Olsztyn; 2019, 22(1); 75-86
1505-4675
2083-4527
Pojawia się w:
Technical Sciences / University of Warmia and Mazury in Olsztyn
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the Quality of Stabilized Municipal Sewage Sludge
Autorzy:
Bartkowska, Izabela
Biedka, Paweł
Tałałaj, Izabela Anna
Powiązania:
https://bibliotekanauki.pl/articles/124921.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
autothermal thermophilic aerobic digestion
digestion of sludge
natural utilization of sludge
sludge
Opis:
The sludge management of many wastewater treatment plants in Poland has not been properly solved yet. The exploiters and designers often have to cope with the dilemma of choosing the method of processing and neutralizing sewage sludge. The method discussed in the article is only one of the options that fully fits in the trends of implementing good practices in the management of sewage sludge. It is a technologically and economically effective as well as environmentally friendly process. It contributes significantly to minimizing the amount of sewage sludge and allows the production of organic fertilizer instead of waste. The work discusses the quality of sewage sludge after autothermal thermophilic stabilization (ATAD). The results of investigations pertaining to the reaction of sludge, dry mass, dry organic matter, content of biogenic substances, calcium and magnesium compounds and heavy metals were analyzed.
Źródło:
Journal of Ecological Engineering; 2019, 20, 2; 200-208
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Changes in hydrogen ion exponent of sewage sludge in the process of autothermal thermophilic aerobic digestion
Autorzy:
Bartkowska, I.
Powiązania:
https://bibliotekanauki.pl/articles/124965.pdf
Data publikacji:
2014
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
activated sludge
hydrogen ion exponent
sewage sludge
sludge processing
thermophilic aerobic digestion
Opis:
This paper presents a study on the evaluation of digested sewage sludge during the process of Autothermal Thermophilic Aerobic Digestion (ATAD), taking place as a three-tank process at a municipal waste water treatment plant in Luban, Poland. ATAD installation was manufactured by FUCHS Enprotec GmbH Mayen-Deutschland. Over the period from June 2006 to February 2010 sewage sludge digested by tha ATAD-Process was examined. The hydrogen ion exponent was measured in every tank. The results obtained indicated changes in the composition of the digesting sludge at successive stages of the process. Over the study period the ATAD-installation was in both a two- and a three-stage process. pH of sludge under study during the process of the thermophilic stabilisation changes and its value grows significantly, with the installation working in a two-stage arrangement from 6,63 to 7,99, and when the installation was operated as a three-stage system from 6,60 to 8,14. The results collected were subject to the statistical analysis. The paper presents conclusions drawn from the study and own experience.
Źródło:
Journal of Ecological Engineering; 2014, 15, 1; 32-37
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of the Influence of Evaporation and Evapotranspiration on the Volume of Sludge Accumulation in the Sludge Drying Beds
Autorzy:
Velychko, Svitlana
Dupliak, Olena
Powiązania:
https://bibliotekanauki.pl/articles/1839097.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
sludge drying beds
evaporation
evapotranspiration
sludge
sewage
Opis:
At present, the sludge drying beds of the Kyiv wastewater treatment plants are operated as a sludge accumulator in an emergency mode, practically without free volume. The purpose of the work was to determine the equation for the evaporation losses calculation from sludge drying beds and the required free volume for sludge accumulation for the next 7 years. The required free volume was calculated using the water budget method which takes into account evaporation from the water surface and evapotranspiration during the vegetation. The total losses from sludge drying beds is 1076 mm/year in normal year and is 920 mm/year in a cold year. The required free volume was calculated considering the trend of increasing average temperature over the last decade and considering the significant environmental risk. A correction was made for one unfavourable year with cold summer and warm winter and an additional rain rate of 1% probability. The additional free volume required is 3.24 million m3 for 7 years if all three sludge drying beds are operated.
Źródło:
Journal of Ecological Engineering; 2021, 22, 2; 63-69
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the Variability of the Composition of Sewage Sludge Before and After Drying Treatment – SEM Studies
Autorzy:
Kiper, Justyna
Głowacka, Anna
Rucińska, Teresa
Powiązania:
https://bibliotekanauki.pl/articles/124107.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
sewage sludge
sewage sludge management
SEM observation
Opis:
The aim of the study was to determine the physical and chemical properties of the sewage sludge from “Pomorzany” and “Zdroje” municipal wastewater treatment plants located in Szczecin, Poland. The paper presents the outcomes of SEM observation of dried and stabilized sewage sludge. The research on the obtained materials was conducted using reference methods; the images from a scanning electron microscope were used. The amount of sewage sludge produced with the methods of its management was presented. The technology of sludge management is based on its dehydration up to dry weight content of roughly 20% and then drying in contact dryers up to 90–92% dry weight, separately in both plants. Dried sewage sludge is subsequently burned in mechanical grid boilers at “Pomorzany” WWTP. The analyzed materials were characterized by the pH of 7.90–8.42, dry mass and average organic matter content were 18.949% and 68.903%, respectively. The elements identified in the largest amount on the surface of analyzed materials included calcium, iron, phosphorus, sulphur and silicon. The amount of phosphorus ranging from 1.82 to 3.44% indicates the possibility of using sewage sludge as organic fertilizer product or an alternative source of phosphorus.
Źródło:
Journal of Ecological Engineering; 2019, 20, 7; 45-52
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mechaniczne odwadnianie osadów ściekowych wspomagane wybranym koagulantem i polielektrolitem
Mechanical dewatering of sewage sludge aided by both coagulant and polyelectrolyte
Autorzy:
Bień, B.
Bień, J. D.
Powiązania:
https://bibliotekanauki.pl/articles/126830.pdf
Data publikacji:
2018
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
osady ściekowe
kondycjonowanie
filtracja
efekt odwadniania
nadźwiękawianie
sewage sludge
sludge conditioning
filtration
effect of sludge dewatering
sludge sonication
Opis:
Osady poddawane są wstępnemu przygotowaniu (kondycjonowaniu), aby zwiększyć efekty odwadniania. Kondycjonowanie ma na celu poprawę szybkości odwadniania w wyniku zmniejszenia oporu właściwego oraz ściśliwości osadów. Stopień odwodnienia osadów ściekowych wpływa na sposoby dalszej ich przeróbki, zagospodarowania oraz transportu. Celem badań było określenie możliwości zwiększenia wydajności odwadniania osadów ściekowych przy zastosowaniu metod łączonych wykorzystujących pole ultradźwiękowe oraz środki chemiczne. Zakres pracy obejmował: badania odwadniania osadów w procesie filtracji ciśnieniowej z zastosowaniem nieorganicznego koagulantu i kationowego polielektrolitu oraz czasu ssania kapilarnego. Filtrację ciśnieniową prowadzono w warunkach laboratoryjnych. Ponadto w cieczy osadowej analizowano: ChZT (chemiczne zapotrzebowanie tlenu), zawiesinę ogólną i fosfor. Osady przefermentowane należą do grupy osadów trudno odwadnianych, co odzwierciedla pomiar CSK, wynoszący 2639 s. Najmniejszą wartość CSK - 88 s uzyskano dla nienadźwiękawianych osadów preparowanych PIX-em 113 w dawce 7,0 mg/g s.m.o. Zarówno dawka, jak i rodzaj zastosowanych środków chemicznych, a także czas sonifikacji mają wpływ na procesy zachodzące w osadach. Wzrost skuteczności mechanicznego odwadniania otrzymano przez zastosowanie w preparowaniu osadów metod łączonych, w których wykorzystano wstępne nadźwiękawianie osadów, a nastepnie dawkowanie substancji chemicznych. Spowodowało to obniżenie uwodnienia końcowego oraz zmiany pozostałych parametrów procesu filtracji ciśnieniowej podczas odwadniania osadów ściekowych w odniesieniu do parametrów osadów nienadźwiękawianych. Ponadto łączne działanie pola ultradźwiękowego, PIX-u 113 i Zetagu 8180 pozwoliło na zmniejszenie zawartości zawiesin, ChZT oraz fosforu w cieczach osadowych.
To increase the dewatering effect the sewage sludge should be properly prepared before dewatering. Sludge conditioning is a such process whereby sludge solids are treated with chemicals or various other means to improve dewatering characteristics of the sludge by reducing the specific resistance and the compressibility of the sludge. The aim of the research was to determine the possibility of increasing in the efficiency of sewage sludge dewatering by applying chemical agents and ultrasonic field. The scope of work included dewatering of prepared sludge in a pressure filtration process which was carried out under laboratory conditions. Also some parameters, such: suspension, COD, phosphorus content in sludge supernatant were analyzed. Digestated sludge belonged to the group of hardly dewatered sludge, its CST was of high value (2639 s). The lowest CST value (88.5 s) was obtained for the unsonicated sludge prepared only with PIX-113 at a dose of 7.0 mg/g d.m.o. Both the dose and the type of chemicals used, as well as the time of sonification had an impact on the changes occurring in sludge properties. The increase in the mechanical dewatering efficiency was obtained by using the combined methods applied for sludge preparation, where the sonication of sludge was used at the preliminary stage and then dosing of chemical substances. This resulted in the reduction of the sludge final hydration and changes of other parameters. In addition the combined action of PIX 113 and Zetag 8180 allowed to reduce the content of suspended solids and COD in sludge supernatant.
Źródło:
Proceedings of ECOpole; 2018, 12, 2; 421-432
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zagospodarowanie komunalnych osadów ściekowych metodami termicznymi w obliczu zakazu składowania po 1 stycznia 2016
Utilisation of municipal sewage sludge by thermal methods in the face of storage disallowing
Autorzy:
Bień, J. D.
Bień, B.
Powiązania:
https://bibliotekanauki.pl/articles/399498.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
osady ściekowe
suszenie
spalanie
instalacje termicznego przekształcania
sewage sludge
sludge drying
sludge incineration
thermal methods of sludge utilization
Opis:
Z dniem 1 stycznia 2016 r. zacznie obowiązywać zakaz składowania komunalnych osadów ściekowych na składowiskach odpadów. Modernizacja i budowa nowych oczyszczalni ścieków spowodowała wzrost ilości wytwarzanych komunalnych osadów ściekowych w ostatnich kilkunastu latach. Ich ilość kształtuje się obecnie na poziomie powyżej 500 tys. Mg s.m i zakładany jest dalszy ich wzrost, choć z pewnością nie tak znaczący jak przewidywano jeszcze parę lat temu. Realizując strategię określoną w Krajowym Planie Gospodarki Odpadami (KPGO) polegającą na całkowitym zaniechaniu składowania osadów ściekowych a zdecydowanym zwiększeniu ilości komunalnych osadów ściekowych przetwarzanych przed wprowadzeniem do środowiska oraz osadów przekształcanych metodami termicznymi wielu eksploatatorów oczyszczalni wybrało ten ostatni kierunek. W artykule przedstawiono aktualny stan w zakresie termicznego przekształcania komunalnych osadów ściekowych w Polsce.
According to the data announced by the Central Statistical Office (GUS) in 2014 in Poland, there are more than three thousands municipal wastewater treatment plants. Most of them are relatively new. Modern and highly efficient wastewater treatment systems produce significant amounts of municipal sewage sludge. The amount of sludge starts to create huge problems in their proper management. In addition, from 1st of January 2016 storage of sewage sludge, which so far has been one of the popular methods of sludge management will be impossible. Thermal methods of disposal are currently considered as an interesting option in sludge management. Currently, in Poland there are several plants where sewage sludge is incinerated or dried. The paper presents the status of thermal method of municipal sewage sludge utilization before the date of storage disallowing.
Źródło:
Inżynieria Ekologiczna; 2015, 45; 36-43
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zagospodarowanie komunalnych osadów ściekowych metodami termicznymi
Utilisation of sewage sludge in Poland by thermal method
Autorzy:
Bień, J. D
Powiązania:
https://bibliotekanauki.pl/articles/297623.pdf
Data publikacji:
2012
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
komunalne osady ściekowe
metody termiczne
suszenie
spalanie
współspalanie
sewage sludge
thermal methods
sludge drying
sludge incineration
sludge co-incineration
Opis:
Według danych GUS w 2011 r. ilość komunalnych osadów ściekowych wytworzonych w Polsce wyniosła 519, 2 tys. Mg s.m. Z kolei prognozowana, wg KPGO2014 na 2015 r. ilość suchej masy komunalnych osadów ściekowych osiągnie poziom 642, 4 tys. Mg i będzie wykazywać tendencję wzrostową w kolejnych latach. Tak duża masa osadów będzie stwarzać ogromne problemy w ich zagospodarowaniu. W celu rozwiązania tego problemu stawia się na wykorzystanie termicznych metod unieszkodliwiania osadów. Zgodnie z zapisami Krajowego Planu Gospodarki Odpadami (KPGO2014) przewiduje się, że w perspektywie do 2020 r. ponad 30% osadów będzie termicznie zagospodarowywane. W publikacji przedstawiono aktualny stan prawny oraz metody ostatecznego zagospodarowania osadów w Polsce. Szczególną uwagę zwrócono na metody termiczne, które w świetle ograniczeń innych metod zagospodarowania osadów są traktowane priorytetowo. Potwierdzeniem tego jest choćby ilość budowanych suszarni oraz stacji termicznego przekształcania komunalnych osadów ściekowych.
According to the data announced by the Central Statistical Office (GUS) in 2011 in Poland there were 3143 municipal wastewater treatment plants, and actually sewegerage system is serving more than twenty-five million inhabitants. Most of the wastewater treatment plants are relatively new. The modern and highly efficient wastewater treatment systems produce significant amounts of municipal sewage sludge. The amount of sludge starts to create huge problems in their proper management. In addition, from 1st of January 2016 storage of sewage sludge, which so far has been one of the most popular methods of sludge management will be virtually impossible. Thermal methods of disposal are currently being considered as an interesting way of sludge management. Thermal sludge disposal methods include incineration, co-incineration and so called alternative methods, such as: gasification, pyrolysis or wet oxidation. In Poland generally incineration and co-incineration are used for sludge utilization. Currently there are eleven plants where sewage sludge is incinerated. Seven of them are using fluidized bed technology, in four cases the sewage sludge is burned on the grate. Poland's first plant for sludge incineration was launched in 1997 in Gdynia - Dębogórze and we had to wait more than ten years for the second one. Now as it was mentioned we have 11 installations in Poland. The biggest one is located in Warsaw and it is currently in the start-up process. Sewage sludge is also managed by the co-firing in the cement industry. This is particularly evident in the Cemex group. However, it should be noted that it has been implemented four years ago. In 2009 co-firing of sewage sludge was launched in Chełm cement plant. In Rudniki plant co-incineration started one year later. Nowadays sewage sludge is given to the cement kiln together with coal. Of course the amount of sewage sludge is not a significant volume in the total amount of alternative fuels use, but its share is growing from year to year. Co-combustion of sludge in power boilers is at the stage of technical trial. Sludge is a waste and the process of sludge co-incineration is a thermal waste utilization process what implies certain legal consequences. This reason causes that energy sector is currently not interested in sludge co-incineration.
Źródło:
Inżynieria i Ochrona Środowiska; 2012, 15, 4; 439-449
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Co-digestion of waste from the salmon aquaculture sector with regional sewage sludge: effects on methane yield and digestate nutrient content
Autorzy:
Estevez, M. M.
Tomczak-Wandzel, R.
Akervold, K.
Tornes, O.
Powiązania:
https://bibliotekanauki.pl/articles/1190195.pdf
Data publikacji:
2019
Wydawca:
Gdańska Szkoła Wyższa
Tematy:
fish sludge
co-digestion
sewage sludge
methane
nutrients
Opis:
In Western Norway, the availability of aquaculture waste resources is relevant for both biogas production and nutrients recovery. In this study, fish sludge from the farming of salmon was tested as co-digestion substrate in the anaerobic digestion of municipal sewage sludge from different regional treatment plants. Additions of 5, 10, 25 and 30% of fish sludge in volume were evaluated. Fish sludge did not improve the methane yield of Grødaland sewage sludge. In contrast, Bergen plant’s sewage sludge yield increased up to 40% with additions of 25% fish sludge. Co-digestion mixtures are being further tested in semi-continuous reactors for its long-term process stability, methane yield, and the effects that fish sludge may have on the final digestate’s nutrient content.
Źródło:
Eco-Energetics: technologies, environment, law and economy; 2019, 2; 29--34
2657-5922
2657-7674
Pojawia się w:
Eco-Energetics: technologies, environment, law and economy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Removal of Octyl Phenol Ethoxylate (OPE) Using Processed and Unprocessed Industrial Biological Waste Sludge
Autorzy:
Dinçer, Ali Rıza
Aral, İbrahim Feda
Powiązania:
https://bibliotekanauki.pl/articles/1845422.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
waste sludge
adsorption
octyl phenol ethoxylate
pyrolyzed sludge
Opis:
This study investigated the Octyl Phenol Ethoxylate (OPE) removal potentials of raw and treated industrial treatment sludges (ITS) at different pH. Experiments were conducted in a set of 500 ml Erlenmeyer flasks, into which OPE solutions of 300 ml with different initial concentrations (50-300 μg/l) were added into. Adsorption of Octyl Phenol Ethoxylate from an aqueous solution into ITS105 (T=105°C), ITS300 (T=300°C), ITS600 (T=600°C) and ITS450 (pyrolyzed, T=450°C) was carried out at a room temperature. The OPE adsorption rate increase in the treatment sludge processed at 600°C. As opposed to the sludge treated at 105°C, the adsorption rate decreased as the concentration increased. The reason for this was that the porous structure was degraded at 600°C, and the surface charge balance was disrupted. ITS300 had a lower adsorption capacity for Octyl Phenol Ethoxylate removal than ITS105, ITS600 and ITS450 (pyrolyzed). The treatment sludge pyrolyzed at 450°C conformed with the Freundlich isotherm at pH 4 (R2=0.94) and pH 7 (R2=0.89). The treatment sludge heat-treated at 600°C conformed with the Freundlich isotherm at pH 4 (R2=0.97), pH 7 (R2=0.98) and pH 10 (R2=0.99). Additionally, for ITS600, the Brunauer, Emmett and Teller (BET) isotherm was valid at neutral pH. The OPE adsorption coefficient for ITS600 at pH 4 and pH 7 was calculated as 1.05 L/μg and 1.083 L/μg, respectively. According to the BET isotherm (for ITS600) the qm values at pH 4 and pH 7 were respectively 8.21 μg/g and 2.92 μg/g. The temperature of the adsorption value obtained with the Temkin isotherm showed that the interaction between the OPE and the adsorbent substances was not a chemical or ionic interaction but probably a physical interaction.
Źródło:
Archives of Environmental Protection; 2021, 47, 1; 53-60
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sewage sludge management – a case study
Zarządzanie osadami ściekowymi - studium przypadku
Autorzy:
MIŁEK, Dorota
LATOSIŃSKA, Jolanta
DYK, Zbigniew
Powiązania:
https://bibliotekanauki.pl/articles/435250.pdf
Data publikacji:
2018-06-01
Wydawca:
Uniwersytet Opolski
Tematy:
sludge management
local development
BIONOR SLUDGE technology
gospodarka osadowa
rozwój lokalny
technologia BIONOR SLUDGE.
Opis:
Currently, the constantly growing problem in the municipal economy is the management of sewage sludge. According to the law, it is the local government that is responsible for the utilization of sewage sludge and is obliged to select optimal technologies, obtain funds and convince the community of the necessity of its implementation. BIONOR Company has developed an innovative concept for the separation and utilization of sewage sludge in the BIONOR SLUDGE compact installation. This innovative technology is effective from the perspective of reducing the waste amount and can be used to solve the problem of utilization of sewage sludge produced in small, rural wastewater treatment plants. The aim of the article is the characterization of the BIONOR SLUDGE technology, a comparative analysis of costs of sludge disposal using a variety of methods and an indication of the importance of sludge management for the local development. To achieve the goal set in the article, a discriminative method was used - a description of the BIONOR SLUDGE technological line as well as a case study method - a comparative analysis of the costs of operation of BIONOR SLUDGE technological line and the costs of landfilling and utilizing of sewage sludge. The research results confirm that the monthly operational costs of the BIONOR SLUDGE technological line are lower than the costs of monthly landfilling or disposal. For potential municipalities, the introduction of BIONOR innovative technology is economical. Moreover, its usage is currently essential for many municipalities due to the introduction of a ban on landfilling of this type of waste from 1 January 2016. This technology can be used to solve the problem of utilization of sewage sludge generated in small, rural wastewater treatment plants.
Aktualnie wciąż narastającym problemem w gospodarce komunalnej jest zagospodarowanie osadów ściekowych. Zgodne z prawem to gmina jest odpowiedzialna za ich zagospodarowanie i na niej ciąży obowiązek doboru optymalnych technologii ich zagospodarowania, pozyskania na ten cel funduszy i przekonania społeczności gminy o konieczności ich realizacji. Przedsiębiorstwo Bionor Sp. z o.o. opracowało nowatorską koncepcję separacji i unieszkodliwiania osadów ściekowych w kompaktowej instalacji BIONOR SLUDGE. Ta innowacyjna technologia jest efektywna z punktu widzenia zmniejszania ilości odpadów. Może być wykorzystana w celu rozwiązania problemu zagospodarowania osadów ściekowych wytwarzanych w małych, wiejskich oczyszczalniach ścieków. Celem artykułu jest scharakteryzowanie innowacyjnej technologii BIONOR SLUDGE, analiza porównawcza kosztów unieszkodliwiania osadów ściekowych różnymi metodami oraz wskazanie znaczenia gospodarki osadowej w rozwoju lokalnym. Dla realizacji celu artykułu wykorzystano metodę deskryptywną – opis linii technologicznej BIONOR SLUDGE oraz metodę studium przypadku – analiza porównawcza kosztów eksploatacji linii technologicznej BIONOR SLUDGE z kosztami składowania i utylizacji osadów ściekowych. Wyniki badań potwierdzają, że miesięczne koszty eksploatacji linii technologicznej BIONOR SLUDGE są niższe od miesięcznych kosztów składowania lub utylizacji. Dla potencjalnych gmin wprowadzenie nowatorskiej technologii firmy Bionor jest opłacalne. Ponadto jej wykorzystanie jest aktualnie konieczne dla wielu gmin ze względu na wprowadzenie od 01.01.2016 roku zakazu składowania tego rodzaju odpadów. Technologia ta może być wykorzystana w celu rozwiązania problemu zagospodarowania osadów ściekowych wytwarzanych w małych, wiejskich oczyszczalniach.
Źródło:
Economic and Environmental Studies; 2018, 18, 2; 733-746
1642-2597
2081-8319
Pojawia się w:
Economic and Environmental Studies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fecal sludge management : Insights from selected cities in Sub-Saharan Africa
Autorzy:
Odey, Emmanuel Alepu
Abo, Bodjui Olivier
Giwa, Abdulmoseen Segun
Li, Zifu
Powiązania:
https://bibliotekanauki.pl/articles/205486.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
sanitation
fecal sludge
sludge management
West Africa
urban environment
Opis:
Recent studies have shown that over half of the world’s population lives in urban areas, with the number of people living in slums growing by over 20 million per year and people living in urban areas lacking access to adequate sanitation. This study presents a review of the challenges facing fecal sludge management (FSM). A globally relevant issue in developing urban centers, especially in selected developing countries in West Africa was discussed. Some key findings of the review are that effective sanitation in developing areas depends on the chain of services and that one of the largest problems in sanitation is FSM. This study presents the initial steps toward understanding the main issues involving FSM in developing cities of West Africa. Results are intended to be used as a support for decisions on policies, strategies for FSM, and investments for improved treatment facilities in the region. The study suggests that governments and private sector organizations should develop adequate measures for handling fecal sludge.
Źródło:
Archives of Environmental Protection; 2019, 45, 2; 50-57
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie osadów potechnologicznych z uzdatniania wody do poprawy właściwości sedymentacyjnych osadu czynnego
Use of Post-technological Sludge from Water Treatment to Improve Sedimentation Properties of Activated Sludge
Autorzy:
Masłoń, A.
Opaliński, I.
Powiązania:
https://bibliotekanauki.pl/articles/1813892.pdf
Data publikacji:
2017
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
osad pokoagulacyjny
popłuczyny
osad czynny
osad spęczniały
post-coagulation sludge
backwash water
activated sludge
sludge bulking
Opis:
Przedmiotem opracowania jest określenie wpływu osadów potechnologicznych z uzdatniania wody na właściwości sedymentacyjne osadu czynnego. Przetestowane zostały popłuczyny z uzdatniania wód podziemnych oraz osad pokoagulacyjny z uzdatniania wód powierzchniowych. Badania przeprowadzono w warunkach laboratoryjnych na podstawie obserwacji opadalności osadu czynnego z dodatkiem zróżnicowanych objętości materiałów. Do oceny efektywności zastosowanych osadów potechnologicznych określono opadalność V30 i V60 (objętość osadu odpowiednio po 30 i 60 min. sedymentacji), indeks osadu czynnego, indeksu Donaldsona (indeksu gęstości osadu) oraz prędkość sedymentacji vs. Dodatkowo w celu weryfikacji poprawy opadalności z dodatkiem reagentów wprowadzono wskaźnik opadalności Wo będący ilorazem V30/V60. Badania wykazały przydatność zastosowania osadów potechnologicznych z uzdatniania wody do poprawy właściwości sedymentacyjnych osadu czynnego. Popłuczyny z uzdatniania wód podziemnych osiągnęły najwyższe efekty wspomagania osadu czynnego. Odnotowano maksymalnie 21,6% oraz 26,4% zmniejszenie indeksu osadu czynnego odpowiednio przy dawkowaniu osadu pokoagulacyjnego i popłuczyn. Maksymalny stopień poprawy prędkości sedymentacji osiągnięto przy najwyższych dawkach osadów technologicznych, odpowiednio 58,1% (OP) oraz 75,3% (PP). Mechanizm poprawy sedymentacji osadu czynnego z dodatkiem osadów potechnologicznych jest trudny do określenia, bowiem z jednej strony osad pokoagulacyjny i popłuczyny stanowią zawiesinę, w której obecne są cząstki mineralne o wielkości poniżej 200 µm będące obciążnikiem kłaczków osadu czynnego. Z drugiej jednak strony obecność żelaza w popłuczynach i glinu w osadach pokoagulacyjnych może wpływać na proces opadalności w analogiczny sposób jak koagulanty chemiczne PIX i PAX.
The aim of the paper is the evaluation of post-technological sludge from Water Treatment Plant on improvement of sedimentation properties of activated sludge. The post-coagulation sludge from surface water treatment (OP) and backwash water from groundwater treatment (PP) were used in this study. The studies were performed in the laboratory scale by observing the settleability of activated sludge with the addition of different volume of post-technological sludge. The activated sludge quality used in this study was characterised by a strong sludge bulking and a wide range of sludge volume index. For the evaluation of the efficiency of tested materials in activated sludge the settleability after 30 V30 and V60 minutes, the sludge volume index SVI, the Donaldson index SDI (Sludge Density Index) and value settling velocity vs were determined. Additionally, in order to verify of activated sludge settleability with the addition of post-technological sludge was appointed a sludge settling ratio (Wo) which is a quotient of V30 and V60. Studies showed the usefulness of the application of post-technological sludge from water treatment to improve of sedimentation properties of the activated sludge. Settling tests showed different efficiencies in the activated sludge settleability, depending on the type and amount of post-technological sludge. At a dosage of post-coagulation sludge and backwash water was observed up to 21.6% and 26.4% reduction of sludge volume index. The maximum level of improvement of settling velocity at the highest doses of post-technological sludge amounted to 58.1% (OP) and 75.3% (PP). Better effects of improvement of activated sludge sedimentation were obtained using backwash water than post-coagulation sludge. The mechanism of improvement of sedimentation properties of the activated sludge containing post-technological sludge is difficult to determine. On the one hand the post-coagulation sludge and backwash water are a suspension, wherein the mineral particles are present, which is a weight of activated sludge flocs. The incorporation of particles into flocs of activated sludge increases its relative density On the other hand, the presence of iron ions in backwash water and aluminum ions in post-coagulation sludge may affect the sedimentation activated sludge in the same manner as the chemical coagulant. The backwash water or post-coagulation sludge may be a new effective reagent in activated sludge technology.
Źródło:
Rocznik Ochrona Środowiska; 2017, Tom 19; 745-759
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Selected Technical and Technological Parameters of the Sewage Sludge Stability Process
Autorzy:
Bartkowska, I.
Wawrentowicz, D.
Powiązania:
https://bibliotekanauki.pl/articles/123847.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
autothermal thermophilic stabilization
sewage sludge
dry mass
organic substances
sewage sludge hygienization
sewage sludge in agriculture
Opis:
The article presents the results of the analysis, which was carried out in 2015-2017 on the example of autothermal installation of thermophilic sludge stabilization (ATAD) in a sewage treatment plant in Giżycko. The installation was created in 2003 as the first of its kind and still remains operational. The purpose of the conducted research was to assess the suitability of the analyzed technological parameters as tools that can be used by operators to determine the actual possibilities of changing the operating conditions of the installation or to develop an optimization strategy to reduce the energy demand. The dry mass content and organic dry mass content was used as the assessment indicators. In the analysed period, the sludge from the process contained from 47.47% to 60.80% of organic matter in the dry mass of the sludge. The organic dry matter decrease due to the process was also calculated, and it ranged from 26.4% to 48.7%. The amount of sludge undergoing the process and the amount of electricity consumption were also analysed. On this basis, the energy consumption indicators in the ATAD process were calculated.
Źródło:
Journal of Ecological Engineering; 2018, 19, 4; 69-74
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Municipal Sewage Sludge Processing Method Effect on the Content of Polycyclic Aromatic Hydrocarbons
Wpływ przeróbki osadów ścieków komunalnych na zawartość wielopierścieniowych węglowodorów aromatycznych
Autorzy:
Wiater, Józefa
Wróblewska, Agata
Ofman, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/1811760.pdf
Data publikacji:
2019
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
PAH
sewage sludge
sludge disposal
WWA
osady ściekowe
unieszkodliwianie osadów
Opis:
The aim of the study was to determine PAH content and the share of their individual groups in municipal sewage sludge at individual stages of their production and processing in a municipal wastewater treatment plant. Sludge samples were collected in three study cycles: autumn (November), winter (February) and spring (April) in 2017 and 2018. In each cycle the samples of initial sludge, excessive sludge after press, digestate sludge and digested dehydrated sludge were analyzed. Three samples were taken from each sludge for further analysis. The content of 16 PAH (naphthalene, acenaphthylene, acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, benzo(a)anthracene, chrysene, benzo(b)fluoranthene, benzo(k)fluoranthene, benzo(a)-pyrene, dibenzo(a,h)anthracene, benzo(g,h,i)perylene and indeno(1,2,3-c, d)pyrene) was determined in the samples in the Faculty Chemical Laboratory at Białystok University of Technology. For this purpose, a gas chromatography method coupled to mass spectrometry using a GC/MS Agilent 7890B chromatograph was used. The results were given as single PAH compounds, which were then grouped by the number of aromatic rings. It was found that the total content of 16 PAHs depended on the type of sewage sludge and the highest one occurred in the initial sludge, and much lower in other sediments. The fermentation process, and more drainage of the fermentation sludge, reduced the content of 16 PAHs. The transformation processes had an influence on the hydrocarbon content in particular groups. The share of PAH groups depending on the number of rings in total 16 depended on the date of collection of studied sludges. In the studied sludges, a group of three and four-ring hydrocarbons dominated, and the least was two- and six-ring hydrocarbons. PAH content in all analyzed sludges did not exceed the norm for the total of 11 PAHs proposed by the European Commission for sludge used for agriculture.
Celem pracy było określenie zawartości WWA i udziału poszczególnych grup w komunalnych osadach ściekowych na poszczególnych etapach ich produkcji i przetwarzania w oczyszczalni ścieków komunalnych. Próbki osadów pobrano w trzech cyklach badań: jesienią (listopad), zimą (luty) i wiosną (kwiecień) w 2017 i 2018 roku. W każdym z cykli badano próbki osadu wstępnego, osadu nadmiernego po prasie, osadu przefermentowanego i osadu przefermentowanego poddanego dehydratacji. Z każdego osadu pobrano trzy próbki do dalszej analizy. Zawartość 16 WWA (naftalen, acenaften, acenaften, acenaften, fluoren, fenantren, antracen, fluoranten, piren, benzo(a)antracen, chryzen, benzo(b)fluoranten, benzo(k)fluoranten, benzo(a)piren, dibenzo(a,h)antracen, benzo(g,h,i)perylen i indeno(1,2,3-c, d)piren) zostały zbadane w próbkach w Wydziałowym Laboratorium Chemicznym Politechniki Białostockiej. W tym celu zastosowano metodę chromatografii gazowej sprzężonej ze spektrometrią mas przy użyciu chromatografu GC/MS Agilent 7890B. Wyniki podano jako pojedyncze związki WWA, które następnie pogrupowano według liczby pierścieni aromatycznych. Stwierdzono, że łączna zawartość 16 WWA zależy od rodzaju osadu ściekowego, przy czym najwyższa z nich występuje w osadach wstępnych, a znacznie niższa w innych osadach. Proces fermentacji i dalsze odwadnianie osadu fermentacyjnego zmniejszyły zawartość 16 WWA. Procesy transformacji wpłynęły na zawartość węglowodorów w poszczególnych grupach. Udział grup WWA w zależności od liczby pierścieni w sumie 16 zależał od terminu poboru badanych osadów. W badanych osadach dominowała grupa węglowodorów trój- i czteropierścieniowych, a najmniej dwu- i sześciopierścieniowych. Zawartość WWA we wszystkich analizowanych osadach nie przekraczała normy dla 11 WWA zaproponowanej przez Komisję Europejską dla osadów wykorzystywanych w rolnictwie.
Źródło:
Rocznik Ochrona Środowiska; 2019, Tom 21, cz. 1; 556-565
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sposoby wykorzystania osadów z Oczyszczalni Ścieków w Białymstoku
Ways of sewage sludge use from urban waste water treatment in Bialystok
Autorzy:
Wiater, J.
Butarewicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/296728.pdf
Data publikacji:
2014
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
osady ściekowe
gospodarka osadami ściekowymi
sewage sludge
sewage sludge management
Opis:
W pracy przedstawiono gospodarkę osadową prowadzoną w Oczyszczalni Ścieków w Białymstoku oraz kierunki zagospodarowania osadów wytwarzanych przez oczyszczalnię. Oczyszczalnia Ścieków w Białymstoku jest oczyszczalnią mechaniczno-biologiczną, która stosuje metodę osadu czynnego w procesie oczyszczania ścieków i przeróbkę osadów ściekowych. Biogaz wytwarzany w komorach fermentacyjnych przeznaczany jest na wytwarzanie energii cieplnej i elektrycznej na potrzeby oczyszczalni. Energia cieplna wykorzystywana jest do ogrzania komór fermentacyjnych. Zapewnia to oczyszczalni obniżenie kosztów wynikających z poboru energii z sieci miejskiej oraz zabezpiecza inwestycję w przypadku awarii sieci. Właściwości osadów ściekowych z oczyszczalni w Białymstoku mają zmienny charakter, kształtowany przez rodzaj oczyszczanych ścieków i zastosowane metody przeróbki osadów. Ze względu na swoje właściwości odwodnione osady ściekowe z Oczyszczalni Ścieków w Białymstoku są wykorzystywane do procesu kompostowania, a także do uprawy roślin przeznaczonych na kompost. Po wysuszeniu do postaci granulatu są stosowane do nawożenia lub współspalane jako dodatek do paliw.
The paper presents the sludge management in the wastewater treatment plant in Bialystok and the guidelines of sludge usage produced by this plant. Sewage treatment plant in Bialystok is a mechanical-biological plant, which uses the method of activated sludge in the wastewater treatment process, sludge treatment and the utilization of biogas. Biogas produced in the digesters is used in the production of heat and electricity for the sewage treatment plant. Thermal energy is used to heat the digester. Therefore it reduces the costs of energy consumption from the urban network and protects the investment in case of network breakdown. Sludge properties from the sewage treatment plant in Bialystok have changeable character, shaped by the type of treated wastewater and sludge treatment methods. Due to its properties, dehydrated sludge from wastewater treatment plant in Bialystok is used to: compost, grow plants intended for the production of compost and dried sludge in form of granulate - to fertilize and co-incinerate.
Źródło:
Inżynieria i Ochrona Środowiska; 2014, 17, 2; 282-292
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody zagospodarowania osadów ściekowych. Zagrożenia i szanse
Sewage sludge management methods. Challenges and opportunities
Autorzy:
Cieślik, B.
Konieczka, P.
Powiązania:
https://bibliotekanauki.pl/articles/357611.pdf
Data publikacji:
2016
Wydawca:
Politechnika Śląska
Tematy:
sewage sludge
sewage sludge management
osady ściekowe
zagospodarowanie osadów ściekowych
Opis:
All sludge management methods can be divided into two basic groups: high-temperature processing, and biological and chemical stabilization. The most popular management methods include: drying, disinfection, agricultural use, burning or pyrolysis with the recovery of solid and liquid process residues, phosphorus recovery, biogas recovery, use in the construction industry, and the least pro-ecological landfilling. At present, burning and landfilling are the most popular methods. Sewage sludge management method is determined by compliance with the law connected with management methods. EU directives contain information concerning highest allowable concentrations of contaminants and main statement concerning sewage sludge management methods and their monitoring.
Wszystkie metody zagospodarowania osadów ściekowych można zaliczyć do dwóch podstawowych grup: przetwarzanie wysokotemperaturowe oraz biologiczną i chemiczną stabilizację. Do najbardziej popularnych metod zagospodarowania należą: suszenie, dezynfekcja wykorzystanie w rolnictwie, spopielanie lub piroliza z odzyskiem stałych i płynnych pozostałości procesowych, odzysk fosforu, odzysk biogazu, wykorzystanie w budownictwie oraz, najmniej proekologiczne, składowanie. Obecnie do najbardziej popularnych metod zagospodarowania należą spopielanie i składowanie. Metoda zagospodarowania osadów ściekowych jest uwarunkowana przestrzeganiem aktów prawnych dotyczących zagospodarowania osadów ściekowych. W dyrektywach UE zestawione są informacje o najwyższych dopuszczalnych stężeniach substancji zanieczyszczających, które mogą być wprowadzane do środowiska oraz najważniejsze deklaracje dotyczące zagospodarowania osadów ściekowych oraz ich monitoringu.
Źródło:
Archiwum Gospodarki Odpadami i Ochrony Środowiska; 2016, 18, 1; 15-32
1733-4381
Pojawia się w:
Archiwum Gospodarki Odpadami i Ochrony Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Liming of Acidic Soils with Belite Sludge
Autorzy:
Isakov, A. E.
Barygina, K. V.
Powiązania:
https://bibliotekanauki.pl/articles/124174.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
belite sludge
nepheline sludge
liming
acidic soils
recycling
metallurgical wastes
Opis:
The metallurgical enterprises are a major source of large-tonnage industrial wastes containing valued components. A significant discrepancy between the volumes of waste formations and its utilisation leads to the necessity of large-scale sludge dumping. The article describes a recycling method for belite sludge that is the waste of the alumina production from nepheline concentrate. The physical and chemical properties of belite sludge were analysed and the conclusions about the possibility and outlook of its using as an ameliorant were drown. The main results show that adding the belite sludge to acidic soils provides a certain positive effect. The main conclusions allow to say that belite sludges are an ecologically safe substance that can be used as a liming material for acidic soils.
Źródło:
Journal of Ecological Engineering; 2017, 18, 6; 95-102
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of respirometric tests for assessment of methanogenic bacteria activity in wastewater sludge processing
Autorzy:
Cimochowicz-Rybicka, M
Rybicki, S
Powiązania:
https://bibliotekanauki.pl/articles/124522.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
sewage sludge
methanogenic activity
sludge digestion
renewable energy
energy recovery
Opis:
Production of a methane-rich gas (‘biogas’) is contemporary popular sludges processing technology which allows to generate thermal and/or electric energy. Formal requirements issued by the European Union to promote so called renewable energy resources made these process more attractive leading to its application in WWTPs which were designed based on different sludge handling processes. Authors (as active design engineers) noted that dimensioning sludge digestion chamber is usually based on SRT assessment without any emphasis on sludge characteristics. Bio-mass characteristics and the estimation of its activity with respect to methane production are of great importance, from both scientific and practical points of view, as anaerobic digestion appears to be one of crucial processes in municipal wastewater handling and disposal. The authors propose respirometric tests to estimate a biomass potential to produce ‘a biogas’ and several years’ laboratory and full scale experience proved its usefulness and reliability both as a measurement and a design tool applicable in sludge handling. Dimensioning method proposed by authors, allows to construct and optimize operation of digestion chambers based on a methanogenic activity.
Źródło:
Journal of Ecological Engineering; 2013, 14, 3; 44-52
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Alternating Aerobic and Anoxic Conditions to Eliminate Sludge Accumulation in the Oxidation Ditch System
Autorzy:
El-Morsy, Ahmed
Ayoub, Mohamed
Powiązania:
https://bibliotekanauki.pl/articles/24201600.pdf
Data publikacji:
2023
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
activated sludge
denitrification
nitrification
oxidation ditch
sludge accumulation
upgrade
wastewater treatment
Opis:
The purpose of the present study is to investigate the performance of an upgraded oxidation ditch (OD) system, which was designed and implemented to solve the problem of sludge accumulation at the bottom as well as to get the best removal efficiency of total nitrogen (TN). The upgrading concept is based on dividing the operating volume of the upgraded OD to achieve interchanging between aerobic and anoxic circumstances in order to provide simultaneous nitrification and denitrification (SND). The obtained results indicated that the average TN removal efficiency was 60%, which could be obtained due to a highly efficient SND approach. In addition, the better TN removal efficiency corresponds to the lower sludge volume index (SVI), which reflects the efficiency of the upgraded OD in preventing the accumulation of sludge at the bottom. Effluent ammonium-nitrogen (NH4+-N) and nitrate (NO3--N) concentrations corresponding to a minimum SVI of 41.9 mL/g were 8.6 mg/L for NH4+-N and 8.6 mg/L for NO3--N, respectively. Furthermore, the upgraded OD successfully removes 5-day biochemical oxygen demand (BOD5), chemical oxygen demand (COD), and total suspended solids (TSS) below the permissible limit for final effluent of 60, 80, and 50 mg/L respectively.
Źródło:
Journal of Ecological Engineering; 2023, 24, 3; 304--314
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of Aerobic Stabilization of Sewage Sludge on PAHs Concentration in Reject Waters
Autorzy:
Kozak, Jolanta
Włodarczyk-Makuła, Maria
Popenda, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/1839628.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
PAHs
municipal sewage sludge
coking sewage sludge
reject water
aerobic stabilization
Opis:
In the paper, the results of studies on changes in the concentration of selected polycyclic aromatic hydrocarbons (PAHs) in the reject water coming from aerobic stabilization of sewage sludge process were given. The sewage sludge samples originating from a treatment of municipal wastewater treatment plant and an industrial coking wastewater treatment plant were investigated. A technological study was conducted using a municipal sewage sludge (control sample) and a mixture of municipal and industrial sewage sludge simultaneously. Aerobic stabilization of sewage sludge process was carried out for 21 days. The concentration of PAHs was determined at the beginning of the experiment (day 0) and in seven-day intervals: after 7, 14 and 21 days. The initial concentration of PAHs in the reject water coming from the municipal sewage sludge was over 44 g/dm3. Industrial sewage sludge was heavily loaded with polycyclic aromatic hydrocarbons. In a reject water of the mixture of municipal and industrial sludge, the initial content of PAHs reached over 5200 g/dm3. During aerobic stabilization of sewage sludge, a decrease in PAHs concentration in reject water was observed. After 21 days of the experiment, the decrease of the sum of analyzed PAHs was in the range of 62–98%.
Źródło:
Journal of Ecological Engineering; 2021, 22, 4; 27-35
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies