Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Reactive Power control" wg kryterium: Temat


Tytuł:
The Large Customer Reactive Power Control Possibilities
Wykorzystanie możliwości regulacyjnych mocy biernej wielkich odbiorców
Autorzy:
Małkowski, R.
Szczerba, Z.
Powiązania:
https://bibliotekanauki.pl/articles/397060.pdf
Data publikacji:
2014
Wydawca:
ENERGA
Tematy:
voltage control
reactive power control
large customer
Opis:
In this paper the authors wish to draw attention to the rationale for, and the possibility of, the use of local reactive power sources by the Transmission Node Master Controller (TNMC). Large Customers (LC) are one of the possible reactive power sources. The paper presents the issues related to the need for coordination between the control systems installed in the LC network, and coordination between control systems of the LC as well as master control systems in the network.
Autorzy artykułu zwracają uwagę na celowość i możliwość wykorzystania lokalnych źródeł mocy biernej przez układy regulacji grupowej węzła przesyłowego (RGWP). Jednym z takich źródeł są wielcy odbiorcy (WO). W artykule przedstawiono również zagadnienia związane z potrzebą koordynacji pomiędzy układami regulacji zainstalowanymi w sieci WO oraz koordynacji pomiędzy układami regulacji WO a układami regulacji nadrzędnej w sieci.
Źródło:
Acta Energetica; 2014, 1; 114-125
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Coordination of voltage and reactive power control in the extra high voltage substations based on the example of solutions applied in the national power system
Koordynacja regulacji napięcia i mocy biernej w stacjach najwyższych napięć na przykładzie rozwiązań stosowanych w KSE
Autorzy:
Kołodziej, D.
Klucznik, J.
Powiązania:
https://bibliotekanauki.pl/articles/397624.pdf
Data publikacji:
2012
Wydawca:
ENERGA
Tematy:
system elektroenergetyczny
regulacja mocy biernej
regulacja napięcia
power system
reactive power control
voltage control
Opis:
This paper presents examples of coordination between automatic voltage and reactive power control systems (ARST) covering adjacent and strongly related extra high voltage substations. Included are conclusions resulting from the use of these solutions. The Institute of Power Engineering, Gdańsk Division has developed and deployed ARST systems in the national power system for a dozen or so years.
W artykule przedstawiono przykłady koordynacji pracy układów regulacji napięć i mocy biernych (ARST) obejmują- cych sąsiednie, silnie powiązane stacje najwyższych napięć. Zawarto wnioski wynikające ze stosowania tych rozwiązań. Instytut Energetyki Oddział Gdańsk od  kilkunastu lat opracowuje i  wdraża układy ARST w  krajowym systemie elektroenergetycznym.
Źródło:
Acta Energetica; 2012, 2; 43-50
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie możliwości regulacyjnych mocy biernej wielkich odbiorców
The large customer reactive power control possibilities logic
Autorzy:
Małkowski, R.
Szczerba, Z.
Powiązania:
https://bibliotekanauki.pl/articles/266984.pdf
Data publikacji:
2013
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
regulacja napięcia
regulacja mocy biernej
wielcy odbiorcy
Voltage Control
Reactive Power control
large customer
Opis:
W niniejszej pracy autorzy pragną zwrócić uwagę na celowości, i możliwości wykorzystania lokalnych źródeł mocy biernej przez układy Regulacji Grupowej Węzła Przesyłowego (RGWP). Jednym z takich źródeł są Wielcy Odbiorcy (WO). W pracy przedstawiono również zagadnienia związane z potrzebą koordynacji pomiędzy układami regulacji zainstalowanymi w sieci WO oraz koordynacji pomiędzy układami regulacji WO a układami regulacji nadrzędnej w sieci.
In this paper, the authors wish to draw attention to the purpose, and the possibility of using local reactive power sources by Transmission Node Master Controller (TNMC). Large Customers (LC) are one of the possible reactive power sources. The paper presents the issues related to the need for coordination between the control systems installed in the LC network, and coordination between control systems the LC as well as master control systems in the network.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2013, 32; 123-126
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Usage of Wind Farms in Voltage and Reactive Power Control Based on the example of Dunowo Substation
Wykorzystanie farm wiatrowych do regulacji napięcia i mocy biernej na przykładzie węzła Dunowo
Autorzy:
Kołodziej, D.
Klucznik, J.
Powiązania:
https://bibliotekanauki.pl/articles/396918.pdf
Data publikacji:
2014
Wydawca:
ENERGA
Tematy:
voltage control
reactive power control
wind farms
ARST
URST
regulacja napięcia
regulacja mocy biernej
farmy wiatrowe
Opis:
The article describes a control system designed at the Institute of Power Engineering Gdańsk Division, which has been applied in Dunowo substation and nearby wind farms. Control systems use wind farms in the process of voltage and reactive power control. The device structure, rules of control and requirements described in the Instruction of Transmission System Operation and Maintenance (grid code) released by Polskie Sieci Elektroenergetyczne Operator SA the Transmission System Operator in Poland are presented.
W artykule przedstawiono opracowany i zrealizowany przez Instytut Energetyki system regulacji napięć i mocy biernych dla węzła Dunowo, obejmujący stację elektroenergetyczną najwyższych napięć oraz dwie spośród wielu farm wiatrowych. Zaprezentowano aktualne wymagania OSP dotyczące regulacji napięcia z wykorzystaniem farm wiatrowych. Przedstawiono budowę i strukturę systemu, reguły działania jego składników, a także zasady koordynacji regulacji transformatorowej w stacji najwyższych napięć i generatorowej w farmach wiatrowych.
Źródło:
Acta Energetica; 2014, 1; 59-71
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie farm wiatrowych do regulacji napięcia i mocy biernej na przykładzie węzła Dunowo
Usage of wind farms in voltage and reactive power control based on dunowo substatnion example
Autorzy:
Kołodziej, D.
Klucznik, J.
Powiązania:
https://bibliotekanauki.pl/articles/269033.pdf
Data publikacji:
2013
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
ARST
URST
regulacja napięcia
regulacja mocy biernej
farmy wiatrowe
voltage control
reactive power control
wind farms
Opis:
W artykule przedstawiono opracowany i zrealizowany przez Instytut Energetyki system regulacji napięć i mocy biernych dla węzła Dunowo obejmujący stację elektroenergetyczną najwyższych napięć oraz dwie, spośród wielu, przyłączone farmy wiatrowe. W treści zaprezentowano aktualne wymagania OSP dotyczące regulacji napięcia z wykorzystaniem farm wiatrowych. Przedstawiono budowę i strukturę wykonanego systemu, zasadę działania jego składników a także zasady koordynacji regulacji transformatorowej w stacji najwyższych napięć i generatorowej w farmach wiatrowych.
Article describes control system designed in Institute of Power Engineering Gdańsk Division, which has been applied in substation Dunowo and nearby wind farms. Control systems uses wind farms in process of voltage and reactive power control. Presented are device structure, rules of control and requirements described in Instruction of Transmission System Operation and Maintenance (grid code) released by the Polish Transmission System Operator.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2013, 32; 119-122
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie obiektów danych zgodnych z IEC 61850 w układach regulacji napięcia i mocy biernej
Data objects modelling of voltage and reactive power control systems according to standard IEC 61850
Autorzy:
Kołodziej, Dariusz
Opala, Ksawery
Ogryczak, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/267869.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
norma IEC 61850
regulacja napięcia
regulacja mocy biernej
ARST
ARNE
standard IEC 61850
voltage power control
reactive power control
Opis:
W pracy opisano przykład modelowania prototypowego układu regulacji napięcia i mocy biernej zgodnie z rozwiązaniami zawartymi w normach IEC 61850 (PN-EN 61850). Typowe urządzenia stosowane w energetyce oraz funkcje przez nie realizowane (zabezpieczenia, regulatory itp.) zostały ustandaryzowane i ujęte w normach jako kompatybilne klasy węzłów logicznych. Wiele urządzeń, zwłaszcza prototypowych lub stosowanych w mniejszej skali, nie posiada swojej reprezentacji w normach IEC 61850. Autorzy tych układów samodzielnie tworzą modele obiektów danych a następnie własne definicje węzłów logicznych postępując zgodnie z określonymi w normach zasadami. W Polsce takim przykładem są układy regulacji napięcia i mocy biernej dla stacji najwyższych napięć oraz elektrowni (ARST lub ARST/ARNE).
The paper presents the example of modelling prototype voltage and reactive power control device according to the solutions contained in the standards IEC 61850 (PN-EN 61850). Typical devices used in power engineering and their implemented functions (protections, controllers, etc.) have been standardized and defined in the standards as a compatible class of logical nodes. Many devices, especially prototype devices or those used on a lesser scale, do not have their representation in IEC 61850 standards. The authors of these systems create models of data objects independently and next, their own definitions of logical nodes following the rules defined in the standards. In Poland, such examples are voltage and reactive power control systems for the highest voltage substations and power plants (ARST or ARST/ARNE).
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 62; 143-147
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analysis of power control schemes in dfig for wind energy generation
Analiza porównawcza metod stosowanych do regulacji mocy czynnej i biernej w dwustronnie zasilanym generatorze indukcyjnym
Autorzy:
Jedut, L.
Rosołowski, E.
Powiązania:
https://bibliotekanauki.pl/articles/410545.pdf
Data publikacji:
2011
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
wind generation
doubly-fed induction generator
active and reactive power control
stator flux reference frame
Opis:
This paper describes two algorithms applied for active and reactive power control in wind turbine driven doubly fed induction generator (DFIG). The first proposed method applies the PI controllers for regulation of DFIG power and the rotor current while the second one utilizes a difference approximation of a given flux derivative. Both algorithms are based on the model description with reference to the stator flux linkage frame. General description of the analyzed methods is delivered and some results of simulations are included.
W artykule przedstawiona jest analiza dwóch algorytmów stosowanych do regulacji mocy czynnej i biernej w elektrowniach wiatrowych z dwustronnie zasilanymi generatorami indukcyjnymi. W pierwszej rozważanej metodzie stosowane są regulatory PI do kontroli mocy i prądu wirnika, podczas gdy w drugiej - całkowanie ciągłe jest aproksymowane za pomocą zależności przyrostowych. W obu algorytmach model maszyny jest zapisany względem układu współrzędnych związanych ze strumieniem stojana. Zamieszczony jest opis rozważanych modeli oraz wyniki przeprowadzonych symulacyjnych testów.
Źródło:
Present Problems of Power System Control; 2011, 1; 75-88
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Expedience of using reactive power sources installed in an MV grid for V and Q control
Celowość wykorzystania źródeł mocy biernej zainstalowanych w sieci SN do regulacji U i Q
Autorzy:
Małkowski, R.
Szczerba, Z.
Powiązania:
https://bibliotekanauki.pl/articles/397130.pdf
Data publikacji:
2012
Wydawca:
ENERGA
Tematy:
voltage control
reactive power control
medium voltage network
distributed generation
regulacja napięć
źródła mocy biernej
sieć średniego napięcia
generacja rozproszona
Opis:
The paper contains comments on the expedience, feasibility, and potential manner of using reactive power sources for V and Q control in an MV grid. Also indicated is the expedience of quality control verifi cation of 110 kV / MV transformers supplying the grid.
W artykule zawarto uwagi dotyczące celowości, możliwości oraz ewentualnego sposobu wykorzystania źródeł mocy biernej w celu regulacji U i Q w sieci SN. Wskazano również na celowość weryfikacji jakości sterowania transformatorów zasilających sieć 110 kV/SN.
Źródło:
Acta Energetica; 2012, 3; 36-44
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie baterii kondensatorów zainstalowanych w sieci SN do ograniczenia strat mocy w sieci
Activity coordination of capacitor banks and power transformer controllers in order to reduce power losses in the MV grid
Autorzy:
Dzionk, A.
Małkowski, R.
Włas, M.
Powiązania:
https://bibliotekanauki.pl/articles/269090.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
regulacja napięcia
regulacja mocy biernej
straty mocy
regulator transformatora
regulator baterii kondensatorów
voltage control
reactive power control
Power Losses
transformer controller
capacity banks controller
Opis:
W artykule przedstawiono wyniki badań pokazujące możliwości wykorzystania baterii kondensatorów zainstalowanych wewnątrz sieci SN (w odbiorców przemysłowych), w celu zminimalizowania strat mocy w sieci elektroenergetycznej. Wyniki analizy pozwoliły określić, które ze stosowanych obecnie kryteriów regulacji jest najbardziej korzystne. Wskazywano również na konieczność koordynacji działań regulatorów transformatora i baterii kondensatorów.
One of the main issues related to the optimization of the MV network is to reduce losses of active and reactive power. Lower losses of active and reactive power give not only economic advantage, but also improvement of energy quality. The object of regulation that can be used for these purposes are transformer with On-Load Tap Changer and capacitor's banks. This paper presents results of analysis of the possibility of using capacitor banks installed inside the MV network (in industrial consumer) in order to minimize power losses in the power network. The results of analysis allowed to determine which of the criteria adjustment: constant voltage or maintain constant values tgφ, in individual buses is better. It was also pointed to the necessity of the coordination between actions of regulators of the transformer and capacitor banks.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 47; 47-50
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Koncepcja wyceny kosztów świadczenia usługi kompensacji mocy biernej przez jednostki wytwórcze
The concept for valuation of the costs for the provision of reactive power compensation service by manufacturing units
Autorzy:
Czarnecki, Bogdan
Magulski, Rafał
Powiązania:
https://bibliotekanauki.pl/articles/266970.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
regulacja napięcia
regulacja mocy biernej
usługi systemowe
koszty świadczenia usług
wymagane przychody
voltage power control
reactive power control
system services
costs of providing services
required revenues
Opis:
Rozwój krajowej struktury wytwarzania energii oraz związanej z nią topologii sieci przesyłowej może skutkować w szczególnych przypadkach problemami z utrzymaniem wymaganych poziomów napięć i zwiększonym zapotrzebowaniem na regulację mocy biernej. Zapotrzebowanie na regulację mocy biernej ma charakter lokalny i wobec ograniczonej liczby potencjalnych dostawców, kontraktacja usługi przez OSP na zasadach konkurencyjnych jest trudna do przeprowadzenia. Jednostki wytwórcze zlokalizowane w KSE mają nieodpłatny obowiązek zapewnienia zdolności do generacji mocy biernej w określonym przepisami zakresie. Płatną usługą jest grupowa regulacja napięcia i mocy biernej w systemie ARNE. Obecny katalog usług regulacyjnych nie przewiduje zachęt ekonomicznych do oferowania zwiększonego w stosunku do wymagań zakresu regulacji mocy biernej. Mając na uwadze powyższe względy w referacie przedstawiono koncepcję wynagradzania za gotowość jednostek wytwórczych do udostępnienia szerszego zakresu regulacji mocy biernej, bazującą na wycenie kosztów związanych z utrzymaniem i eksploatacją majątku produkcyjnego zaangażowanego w świadczenie usługi.
The development of the national energy generation structure (the concentration of wind energy in the northern part of Poland at the location majority of conventional power plants in the central and southern part) and the related topology of the transmission network may result in specific problems with maintaining the required voltage levels and increased demand for reactive power regulation. The planned implementation of projects for the construction of offshore wind farms in the Baltic Sea may deepen the above challenges. The demand for reactive power regulation is local and due to a limited number of potential suppliers that may use their market power, contracting a service by a TSO on a competitive basis is difficult to implement. The generating units located in the National Power System have a free obligation to ensure the capability of reactive power generation in the specified scope. Paid service is group regulation of voltage and reactive power in the ARNE system, provided by centrally available units. The current catalog of regulatory services does not provide for economic incentives to offer increased reactive power control in relation to the requirements. Bearing in mind the above considerations, the paper presents the concept of rewarding for the readiness of generating units to provide a wider range of reactive power regulation, based on the valuation of costs related to the maintenance and operation of the productive assets involved in providing the service.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 63; 57-60
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Symulacja pracy przesuwnika fazowego w sieci elektroenergetycznej przy połączeniu transformatora szeregowego w gwiazdę
A computer simulation of the phase shifter effects in the power system with wye connection of the series transformer
Autorzy:
Sarnicki, M.
Tarakan, B.
Zajczyk, R.
Powiązania:
https://bibliotekanauki.pl/articles/268014.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
przesuwnik fazowy
regulacja przepływu mocy czynnej i biernej
regulacja kąta mocy
Phase Shifter
active and reactive power flow control
power angle
Opis:
Poniższy artykuł prezentuje sposób regulacji mocy czynnej i biernej za pomocą przesuwnika fazowego, którego uzwojenie transformatora dodawczego (szeregowego) jest połączone w gwiazdę. W artykule pokazano regulację mocy czynnej i biernej na przykładzie wybranego systemu elektroenergetycznego. Omawiany przesuwnik fazowy reguluje jednocześnie przepływem mocy czynnej i biernej w danym systemie elektroenergetycznym.
The following article describes the adjustment of the active and reactive power using the phase shifter. The winding of the booster transformer (series) is wye connected. The article shows the regulation of the active and reactive power for selected power system that is 10 bus system with phase shifter. The phase shifter also regulates flow of the active and reactive power simultaneously in the power system. The most common situation is when the both power regulation are independent and it is a better way to have control of both of them. The simultaneous regulation of the active and reactive power is possible by adding transformed voltage from different phases.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 47; 167-169
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie możliwości przesyłowych dwóch układów regulacyjnych: transformatorów z regulacją poprzeczną oraz transformatorów z regulacją wzdłużną
A comparison transmission capacity of two regulation transformers with quadrature regulation and in-phase regulation
Autorzy:
Sarnicki, M.
Zajczyk, R.
Tarakan, B.
Tarakan, K.
Powiązania:
https://bibliotekanauki.pl/articles/267801.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
przesuwnik fazowy
regulacja przepływu mocy czynnej
regulacja przepływu mocy biernej
regulacja kąta mocy
transformator dodawczy
Phase Shifter
active power flow control
reactive power flow control
power angle
booster transformer connections
Opis:
Poniższy artykuł przedstawia możliwość regulacji mocy czynnej i biernej przepływającej pomiędzy podsystemami elektroenergetycznymi. Do regulacji przepływów wykorzystano przesuwnik fazowy i transformator dodający napięcie w fazie. Zilustrowana została regulacja mocy czynnej i biernej w badanym systemie elektroenergetycznym. Istotna jest zależność regulacji danej mocy od układu połączeń strony SN transformatora dodawczego (czy układ działa, jako przesuwnik czy jako transformator dodający napięcie w fazie).
This paper describes the regulation of active and reactive power between the subsystems in larger power system. To regulate the flow were used phase shifters and booster transformer which adds voltages in phase. The regulation of the active power and reactive in considered power system was shown in this article. Important is the way to regulate a certain kind of power (active or reactive), which strongly depends of MV side connections of booster transformer (whether the system acts as a phase shifter or as a transformer which adds the voltage in phase).
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 42; 89-91
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental Investigations of the Upqc Arrangement
Autorzy:
Benysek, G.
Powiązania:
https://bibliotekanauki.pl/articles/262602.pdf
Data publikacji:
2006
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
power quality
power flow control
harmonics compensation
reactive power compensation
Opis:
This paper presents the fundamental properties and dependences describing the UPQC (Unified Power Quality Conditioner) arrangements. The UPQC devices simultaneously permit to fulfill the following functions: voltage and current harmonics compensation, network voltage and load current symmetrization as well as network voltage stabilization and power flow control. The selected results of the experimental investigations conducted on the small power laboratory model have been described. Applied method for DC link capacity selection was talked over in details and confirmed with experimental results. Results of experimental investigations, including operation of the UPQC arrangement in case of thyristor rectifier load were also introduced.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2006, 12, 1; 27-34
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An optimization model for reactive power control of super high voltage grid systems
Autorzy:
Shaban, M. A.
Powiązania:
https://bibliotekanauki.pl/articles/377699.pdf
Data publikacji:
2012
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
MVAR
super high voltage grid systems
power control
voltage control
reactive power
Opis:
This paper develops an optimization model to control the excessive (MVAR) generation by super high voltage gird systems for maintaining the nodal voltages within the required acceptable margin. The model enhances an approximate solution on the condition of balanced real power. The pseudo-inverse method of optimization is implemented as an optimal optimization is implemented as an optimal means of solving non-square systems of equations based on LaGrange's theory of optimization. It recommends the locations and ratings of the minimum required reactors from the preinstalled ones that to be in service for optimum nodal reactive power and voltage controls.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2012, 69; 89-93
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sterowanie bilansem mocy biernej wielkiego odbiorcy przemysłowego w układzie regulacji grupowej ARNE/ARST
Controlling of the reactive power balance by a great industrial receiver in ARNE/ARST group control system
Autorzy:
Kolendo, Piotr
Klucznik, Jarosław
Drop, Mateusz
Powroźnik, Marek
Powiązania:
https://bibliotekanauki.pl/articles/267463.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
układ regulacji grupowej ARNE
sterowanie bilansem mocy biernej
układ ARST
ARNE group control system
control of reactive power balance
ARST system
Opis:
W ostatnich latach niektórzy wielcy odbiorcy (WO) przemysłowi przyłączeni do Krajowej Sieci Elektroenergetycznej (KSE) budują bloki energetyczne dużych mocy przeznaczone do zasilania własnych zakładów przemysłowych, jak również produkcji energii na sprzedaż do sieci elektroenergetycznej. Nowe bloki połączone są więc równocześnie z zakładem przemysłowym, jak i z siecią nadrzędną, co powoduje znaczną komplikację algorytmów regulacji dla układów automatyki. Pomimo zmiany profilu zakładów przemysłowych z odbioru na wytwarzanie zakłady te zmuszone są do utrzymywania odpowiedniego bilansu mocy biernej z SEE ze względu na wymagania rozliczeniowe. W artykule autorzy przedstawiają sposób sterowania bilansem mocy biernej oraz sposób koordynacji algorytmów w układach regulacji grupowej dla istniejącego węzła elektroenergetycznego w KSE.
In recent years, some Great Industrial Receivers connected to the National Power System have been building high-power energy blocks intended to supply their own industrial factories as well as to sell energy to the transmission network. The new blocks are thus connected at the same time with an industrial plant as well as with a transmission network, which causes a significant complication of regulation algorithms for automation systems. Despite the change in the profile of industrial factories to production, these factories are forced to maintain an adequate balance of reactive power with transmission network due to settlement requirements. As part of the work, the authors will present the method of controlling the reactive power balance and the method of algorithms coordination in group control systems for the existing power node in KSE.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 62; 155-162
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies