Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Pollutants" wg kryterium: Temat


Tytuł:
Emission Assessment at the Štěpánovice Municipal Solid Waste Landfill Focusing on Ch4 Emissions
Autorzy:
Adamcová, D.
Vaverková, M.
Břoušková, E.
Powiązania:
https://bibliotekanauki.pl/articles/123605.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
municipal solid waste landfill
landfill gas
Integrated Register of Pollutants
waste
Opis:
The study was conducted to measure the emission from landfill in the years 2005– 2011. The results are used to diagnose the emissions of CH4. The mean value of CH4 in vol. % in the collection wells ranged from 0 to 2.14 vol. % the mean concentration of CH4 in mg/m3 ranged from 0 to 25 251 mg/m3, the average concentration of CH4 in mg/Nm3 at the measuring and control points ranged from 2.2 to 24.1 mg/Nm3. CH4 emissions from the landfill do not exceed the reporting thresholds the landfill does not meet conditions for being included in the Integrated Register of Pollutants.
Źródło:
Journal of Ecological Engineering; 2016, 17, 3; 9-17
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the Dispersion of Nitrogen Dioxide and Carbon Monoxide in the Indoor Café – Case Study
Autorzy:
Al-Sultan, Ammar A.
Jumaah, Ghufran F.
Al-Ani, Faris H.
Powiązania:
https://bibliotekanauki.pl/articles/124047.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
indoor air pollutants
nitrogen dioxide
carbon monoxide
global standard
smoker
Opis:
A popularity café in Baghdad city was chosen to measure the dispersion of nitrogen dioxide (NO2) and carbon monoxide (CO) as examples of the Indoor Air Pollutants (IAPs) which are considered a significant environmental problem. The aims of this research were, firstly, to measure the variation of NO2 and CO concentrations; secondly, to examine the effect of the seasonal variation of indoor temperature (°C) and relative humidity (%) on the dispersion of both NO2 and CO and finally to compare the results with those of the global standards. The volume of café was about 360 m3 and the number of smokers was about 25-35 smoker/day. This work was divided into two parts where the first part includes the experimental work which comprised the measurement of NO2 and CO by GIGs devices. It was lasted about five months commencing from November 2017 to March 2018 and the readings were taken during two intervals at partial time and during peak time. The second part includes the analysis of obtained results and compared the results of those of the global standards for the Indoor Air Quality suggested by WHO, EPA, and European criteria in order to achieve the goals of this work. The results from this research have highlighted a clear increase in the concentrations of NO2 and CO along with the growing numbers of smokers. Furthermore, the concentrations of NO2 and CO were close to some global standard values of short-term exposure at peak time.
Źródło:
Journal of Ecological Engineering; 2019, 20, 4; 256-261
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Urban soil contamination with lead and cadmium in the playgrounds located near busy streets in Cracow (South Poland)
Autorzy:
Aleksander-Kwaterczak, U.
Rajca, A.
Powiązania:
https://bibliotekanauki.pl/articles/184374.pdf
Data publikacji:
2015
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
urban soil
heavy metals
traffic pollutants
playgrounds
Opis:
The pollution of urban soil with heavy metals caused by traffic activity is increasingly becoming a great threat to human health and environmental quality. This paper presents results of research of lead (Pb) and cadmium (Cd) distribution in land on playgrounds situated near busy streets in Cracow (Poland). Samples of sand and soil were collected from the most top layer (0–10 cm). Concentrations of examined metals are: Pb from 6.80 to 54.04 mg/kg and Cd from 1.60 to 2.61 mg/kg, respectively. The highest concentrations were found in sampling points near the busiest roads, and are particularly visible in the case of lead concentration in soil samples. For sand samples, metal concentrations are much lower. Although the results have not determined a high degree of soil’s contamination, they indicate the problem of the children’s exposure to toxic metals. Urban soil should be monitored particularly in such special places as playgrounds.
Źródło:
Geology, Geophysics and Environment; 2015, 41, 1; 7-16
2299-8004
2353-0790
Pojawia się w:
Geology, Geophysics and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Baza danych obiektów topograficznych w projektach Urzędu Marszałkowskiego Województwa Małopolskiego oraz jego jednostkach
The topographic objects database in projects of the Marshal Office of the Malopolska Voivodeship and its units
Autorzy:
Bachowska, J
Łyczko, P
Powiązania:
https://bibliotekanauki.pl/articles/346451.pdf
Data publikacji:
2012
Wydawca:
Polskie Towarzystwo Informacji Przestrzennej
Tematy:
baza danych obiektów topograficznych
emisja zanieczyszczeń
kompozycja mapowa
Topographic Objects Database
emission of pollutants
map composition
Opis:
Baza Danych Obiektów Topograficznych stanowi cenne źródło informacji o obiektach, ale przede wszystkim zawiera wektorowe dane topograficzne. Dane te są podstawowym źródłem przestrzennych opracowań tematycznych na poziomie wojewódzkim. W artykule przedstawiono projekty, które zostały wykonane w 2011 roku przez Urząd Marszałkowski Województwa Małopolskiego, jak i Zarząd Dróg Wojewódzkich w Krakowie, oraz projekty będące w tracie realizacji przez te instytucje. W sposób szczegółowy został przedstawiony jeden z projektów o charakterze środowiskowym, tj. „Inwentaryzacja emisji zanieczyszczeń do powietrza na potrzeby aktualizacji Programu ochrony powietrza dla województwa małopolskiego”. Obecnie BDOT w dużej mierze wykorzystywana jest w projektach środowiskowych, takich jak opracowywanie map akustycznych, mapy proponowanych zabezpieczeń akustycznych i obszarów ograniczonego użytkowania, mapy stężeń zanieczyszczeń czy mapy narażenia mieszkańców na złą jakość powietrza. Doświadczenia z wykorzystania BDOT pozwalają na sformułowanie wniosku, iż baza ta jest odpowiednim źródłem do realizacji zadań o charakterze przestrzennym w skali województwa.
The Topographic Objects Database constitutes a precious source of information about objects, but it predominantly contains topographic vector data which is a basic source of thematic studies at the voivodeship (provincial) level. The paper presents projects carried out in 2011 by the Marshal’s Office of the Małopolska Voivodeship and the Provincial Road Authority in Kraków as well as projects in progress executed by the above mentioned institutions. One of the environmental projects has been presented in detail, namely: “The inventory of pollution emission carried out for the purpose of updating the air protection programme in Małopolska Voivodeship.” Currently, the Topographic Objects Database is to a large extent used in environmental projects, such as drafting acoustic maps, drafting maps of the proposed acoustic protection and the areas of limited use, drafting maps of pollution concentration or maps of inhabitants’ exposure to poor quality air. Experience with the use of Topographic Objects Database allows to formulate a conclusion that the database presents an appropriate source for carrying out tasks of spatial planning at the voivodeship level.
Źródło:
Roczniki Geomatyki; 2012, 10, 6; 17-26
1731-5522
2449-8963
Pojawia się w:
Roczniki Geomatyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Percepcja jakości powietrza oraz jej skutków zdrowotnych jako przedmiot badań w obszarze zdrowia publicznego
Perception of air quality and its health effects, as an topic in public health research
Autorzy:
Balcerzak, Bartosz
Ścibor, Monika
Malinowska-Cieślik, Marta
Powiązania:
https://bibliotekanauki.pl/articles/635095.pdf
Data publikacji:
2012
Wydawca:
Uniwersytet Jagielloński. Wydawnictwo Uniwersytetu Jagiellońskiego
Tematy:
air pollutants
air quality
behaviors related to health
environmental risk acceptance
environmental risk perception
akceptacja środowiskowego ryzyka dla zdrowia
jakość powietrza
percepcja zagrożeń
środowiskowe ryzyko dla zdrowia
zachowania związane ze zdrowiem
zanieczyszczenie powietrza
Opis:
Perceived air quality is an important measure for evaluating the health impact and quality of life in studies that have been carried out in the area of public health for years. The aim of this paper is to review and sum up the multidisciplinary knowledge regarding this topic, as well as to outline some main insights presented in the field of risk perception research. The literature on the perception of air pollution risks is structured around the five topics, proposed by the authors. Particular attention is focused on research that explores such issues as: factors influencing the air quality perception, the association between the subjective assessment of air pollutants and their objectively measured levels, the influence that perception of air quality has on human attitudes and activities. The paper concludes by evaluating the relevance of the reviewed knowledge for the future research and the field of public health practice.
Źródło:
Zdrowie Publiczne i Zarządzanie; 2012, 10, 1; 13-24
2084-2627
Pojawia się w:
Zdrowie Publiczne i Zarządzanie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prognozowanie kumulacji trudno biodegradowalnych zanieczyszczeń w odciekach ze składowisk odpadów
Forecast of the accumulation of pollutants resistant to biodegradation in leachates from landfill
Autorzy:
Baran, W.
Adamek, E.
Sochacka, J.
Sobczak, A.
Makowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/126718.pdf
Data publikacji:
2009
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
odcieki
składowisko odpadów
kumulacja zanieczyszczeń
leachates
landfill
accumulation of pollutants
Opis:
Często stosowanym procesem do oczyszczania odcieków ze składowisk odpadów jest odwrócona osmoza (RO). Wadą tego procesu jest generowanie znacznej ilości odpadów, które ponownie trafiają na składowisko. W pracy przedstawiono model ilustrujący wzrost stężenia substancji trudno biodegradowalnych w odciekach ze składowisk odpadów po ich uprzednim oczyszczeniu metodą RO z refluksem. Model ten zakłada, że procesy biodegradacyjne opisuje równanie kinetyczne pierwszego rzędu. Stwierdzono, że zastosowanie RO z refluksem w przypadku, gdy czas półtrwania substancji jest dłuższy od czasu retencji, powoduje wzrost ilości tej substancji na składowisku odpadów. Postępująca w dłuższym przedziale czasowym kumulacja zanieczyszczeń odpornych na biodegradację może stwarzać poważne zagrożenie dla środowiska.
Leachates from landfills have been often treated using physical processes eg reverse osmosis method (RO). However, this process generates a significant amount of wastes which get again onto landfills. In this study it was established the potential model illustrated an increase of concentration of substances resistant to biodegradation in leachates after their pre-treated using of RO and reflux methods. This model is based on generally accepted assumption that biodegradation processes are described according to the first-order kinetic equation. The results obtained show that using of RO with reflux, in the case when half-life of a compound is longer than a retention time, one observe the increased amount of this substance in landfill. In other words, pollutants resistant to biodegradation will accumulate there. Therefore, the use of reflux in a longer time intervals causes a serious environmental hazard.
Źródło:
Proceedings of ECOpole; 2009, 3, 1; 121-125
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Physical and numerical modeling of heat-flow processes in tangentially pulverized fuel-fired boiler
Autorzy:
Barański, J.
Stąsiek, J.
Blasiak, W.
Powiązania:
https://bibliotekanauki.pl/articles/1955747.pdf
Data publikacji:
2003
Wydawca:
Politechnika Gdańska
Tematy:
combustion
experimental modelling
air pollutants reduction
Opis:
The paper presents results of three-dimensional physical modeling and computer simulations of fluid-flow structures, mixing and combustion processes in a 125 MW tangentially fuel-fired boiler and additional fuel - natural gas. This method is commonly called the reburning process, with an emphasis on the reduction of CO, NOx and SOx. The co-firing process is realized between the main coal burners and additional fuel nozzles. To improve the mixing and combustion processes, a physical technique, the so-called acid/alkali technique, is used to optimize the placement and direction of additional air and fuel nozzles. The best result obtained from physical modeling experiments is studied using numerical simulations with the FLUENT commercial code. Numerical modeling results are then used to analyze the performance of an industrial boiler. These results, compared with measurements in a real boiler, seem to be in good agreement with each other.
Źródło:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk; 2003, 7, 3; 347-362
1428-6394
Pojawia się w:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wspomaganie proekologicznego zarządzania zakładem energetycznym
Pro-ecological power plant management support
Autorzy:
Białecka, B.
Powiązania:
https://bibliotekanauki.pl/articles/340543.pdf
Data publikacji:
2002
Wydawca:
Główny Instytut Górnictwa
Tematy:
elektrownia
zarządzanie proekologiczne
emisja zanieczyszczeń
zanieczyszczenia gazowe
modernizacja
power plant
pro-ecological management
pollutant emission
gaseous pollutants
modernization
Opis:
Wprowadzenie nowych, drastycznych norm emisji, zgodnych z wymogami UE, może w niedalekiej przyszłości spowodować zamykanie elektrowni opalanych węglem kamiennym, obciążających środowisko naturalne. Aby elektrownie te nie musiały być zamykane możliwe jest przystosowanie ich instalacji do obowiązujących norm środowiskowych, przez modernizację i inwestycje doposażeniowe. Działania te, oprócz zaangażowania znacznych środków inwestycyjnych, wymagają także pełnej informacji o wdrożonych technologiach obejmujących ich wycenę w powiązaniu z efektywnością ekologiczną oraz o przydatności do dalszej eksploatacji posiadanych przez elektrociepłownię środków technicznych. Z tych przesłanek wyniknął cel pracy, który dotyczył sporządzenia modelu umożliwiającego zwiększenie (podwyższenie) trafności decyzji dotyczących wyboru technologii redukcji zanieczyszczeń gazowych w określonej sytuacji ekonomicznej i technicznej zakładu. Przy rozwiązywaniu problemów związanych z modernizacją elektrociepłowni wymagana jest optymalizacja decyzji, zaś matematyczne ujęcie tematu w postaci modelu decyzyjnego gwarantuje prawidłową procedurę i kompleksowe uwzględnienie dominujących zmiennych decyzyjnych i dominujących parametrów w procesie doboru trafnych rozwiązań. Sporządzenie modelu decyzyjnego wymagało zdefiniowania, w układzie sekwencyjnym, następujących elementów: głównych celów, funkcji kryterialnej, warunku optymalizacyjnego podstawowych zmiennych decyzyjnych. Czynnikami warunkującymi podejmowanie trafnych decyzji inwestycyjnych dotyczących modernizacji EC jest znajomość aktualnie stosowanych technologii produkcji, stanu technicznego maszyn i urządzeń oraz dostępnych technologii chroniących środowisko naturalne. Istotne znaczenie mają przyjęte w modelu mierniki i kryteria oceny efektywności działań modernizacyjnych. Do podstawowych kryteriów, od których był uzależniony wybór technologii, zaliczono: skuteczność ekologiczną, efektywność ekonomiczną oraz sprawność energetyczną. Do realizacji przyjętego celu badawczego podstawowe znaczenie miało zebranie danych będących podstawą baz wiedzy dostępnych w programie, jak również zebranie i przygotowanie danych empirycznych do weryfikacji modelu. Model opracowano zgodnie ze zdefiniowanymi celami i zadaniami, przyjętymi założeniami dotyczącymi jego struktury, z rodzajem wykorzystywanych danych oraz scenariuszami badawczymi. W artykule przedstawiono strukturę i opis matematyczny zbudowanego modelu, jego implementację komputerową i weryfikację pod kątem poprawności działania.
The introduction of new, drastic, consistent with EU requirements, emission standards may cause in near future the closure of hard coal-fired power plants, affecting the natural environment. In order to avoid the closure of these power plants, possible is the adaptation of their installation to being in force environmental standards by means of modernization and equipment-related investments. These activities, apart form the engagement of considerable investment funds, require also complete information on the implemented technologies, comprising their valuation in connection with ecological ecological efficiency and the suitability of technical means, being in the power plant's possession, for further exploitation. From these promises arose the aim of the work, which concerned the development of a model enabling to improve the accuracy of decisions regarding the selection of technologies relating to the reduction of gaseous pollutions in a determined economic and technical situation of the plant. In case of solving problems connected with the modernization of a thermal-electric power station, optimization of decisions is required, and a mathematical approach to the problem in the form of a decision-making model guarantees correct procedure and comprehensive consideration of predominant decisive variables and predominant parameters in the process of accurate solution selection. The development of the decisive model has required to define, in a sequential system, the following elements: main objectives, criterial function, optimization condition of basic decisive variables. The factors conditioning accurate investment decision taking, concerning the modernization of thermal-electric power stations, is the knowledge of currently applied production technologies, technical state of machines and devices, and accessible technologies, protecting the natural environment. Essential significance have the measuring instruments and efficiency criteria of modernization activities, adopted in the model. To the basic criteria, relating to technology selection, belong: ecological efficiency, economic effectiveness and power efficiency. For the realization of the adopted investigation objective, the basic significance had the collection of data, which constituted the basis of data bases available in the programme, as well as actions aiming at the collection and preparation of empirical data for model verification. The model has been performed in accordance with defined objectives and targets, adopted assumptions concerning its structure, with the kind of data use and research scenarios. The article presents the structure and mathematical description of the constructed model, its computer implementation and verification regarding the correctness of action.
Źródło:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa; 2002, 4; 17-31
1643-7608
Pojawia się w:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transport zanieczyszczeń w rzece z uwzględnieniem dyfuzji dwukierunkowej
Transport of pollutants in a the river with bi-directional diffusion
Autorzy:
Bielski, A
Powiązania:
https://bibliotekanauki.pl/articles/297421.pdf
Data publikacji:
2012
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
zanieczyszczenia
woda
rzeka
adwekcja
dyfuzja dwukierunkowa
stany nieustalone
pollutants
water
river
advection
two-way diffusion
unsteady state
Opis:
Transport zanieczyszczeń w rzece z uwzględnieniem dyfuzji dwukierunkowej W pracy zaprezentowano metodę analitycznego rozwiązywania równania różniczkowego opisującego adwekcyjny transport masy z dwukierunkową dyfuzją w płaszczyźnie normalnej do przepływu w stanach nieustalonych. W metodzie tej funkcję stężenia zapisano w postaci iloczynu trzech funkcji dotyczących czasu oraz dwóch współrzędnych liniowych. Taki sposób reprezentacji funkcji stężenia umożliwia przedstawienie równania transportu masy w postaci trzech równań różniczkowych, odnoszących się tylko do jednej współrzędnej. Rozwiązanie równania transportu masy odnosi się do przypadku równomiernego, prostokątnego rozkładu stężeń zanieczyszczeń w przekroju rzeki. Rozwiązanie umożliwia określenie rozkładu stężeń zanieczyszczeń w przekroju rzeki. Podano również rozwiązania dla przypadku wypływu zanieczyszczeń z nieskończenie małego otworu oraz nieskończenie wąskiej pionowej lub poziomej szczeliny. Sformułowano przybliżone zależności, umożliwiające wyznaczenie czasu przemieszczenia maksymalnego stężenia przekroju do naroża przekroju prostokątnego koryta rzeki oraz czasu wystąpienia stężenia maksymalnego, jakie w ogóle pojawi się w narożu przekroju. Opisano własności otrzymanych rozwiązań. Określono względne momenty wystąpienia maksymalnych zmian stężenia w czasie w wybranym miejscu przekroju koryta rzeki. W przypadku koryta rzeki o przekroju prostokątnym maksymalne zmiany stężeń pojawiają się w przybliżeniu w około 10/47 czasu wystąpienia maksymalnego stężenia w narożu przekroju lub w chwili wystąpienia stężenia stanowiącego 10/32 stężenia maksymalnego, jakie pojawi się w tym narożu. W przypadku ośrodka nieograniczonego maksymalne zmiany stężeń pojawiają się wcześniej, to jest w 10/34 czasu wystąpienia maksymalnego stężenia w tym samym miejscu co w ośrodku ograniczonym. W przypadku ośrodka nieograniczonego maksymalne zmiany stężeń pojawiają się w chwili wystąpienia stężenia stanowiącego 10/33 stężenia maksymalnego, jakie pojawi się w tym samym miejscu co w ośrodku ograniczonym. Ułamek 10/33 wyznaczony dla ośrodka nieograniczonego jest zbliżony do ułamka 10/32 wyznaczonego dla ośrodka ograniczonego (rzeka). Oznacza to, że przebieg zmian stężeń w czasie w tym samym punkcie w obu ośrodkach ma ten sam charakter, a krzywe przedstawiające zmiany stężeń są podobne.
The paper presents an analytical method for solving the differential equation describing the advection mass transport with bi-directional diffusion in the plane perpendicular to the flow in the unsteady state. In this method, a function of concentration is represented through the products of three functions related to coordinates of time and two linears. This manner allows the presentation of the mass transport equation in the form of three differential equations relating to a single coordinate. The solution of mass transport equation refers to the case of uniform, rectangular concentration distribution of pollutants in the river section. The solution allows to specify the distribution of pollutants concentrations in the river section. It also gives solutions for the discharge of pollutants from the infinitely small holeand the infinitely narrow horizontal or vertical gap. It presents formulas to determine the approximate time displacement of peak con-centration of section to a corner of a rectangular cross-section of the river and the time of the maximum concentration at all appears in the corner of the section. In the paper there were de-scribed the properties of obtained solutions. The relative moments of appearance of the maxi-mum changes of concentration with time at a specific location in the river cross-section were described. In the case of rectangular riverbed maximum concentration changes occur approximately at about 10/47 of time of to maximum concentration in a corner section or at the time of the concentration being 10/32 of the maximum concentration that will appear in the corner. In the unlimited space maximum changes of concentration occur earlier at 10/34 time to maximum concentration in the same place than as in the limited space (river). In the unlimited space maximum concentrations occur at the time when concentration is 10/33 of the maximum concentration which will be in the same place as in the limited space. Fraction 10/33 set for unlimited space is close to the fraction 10/32 obtained for limited space (river). This means that the changes of the concentrations at the same point in the two spaces are the same in nature, and the curves of changes in concentration are similar.
Źródło:
Inżynieria i Ochrona Środowiska; 2012, 15, 3; 307-332
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ zrzutu nieoczyszczonych ścieków na środowisko wodne cieku
Influence of untreated sewage discharge on the aquatic environment of the watercourse
Autorzy:
Bielski, A.
Powiązania:
https://bibliotekanauki.pl/articles/297758.pdf
Data publikacji:
2012
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
ścieki
zanieczyszczenia
woda
rzeka
kinetyka przemian zanieczyszczeń
sewage
pollutants
water
river
transformation kinetics of pollutants
Opis:
Przedstawiono sposób oceny wpływu na środowisko wodne nieoczyszczonych ścieków zawierających osad czynny. Odległe w czasie, incydentalne zrzuty ścieków, w szczególności miejskich, wykazują szybki zanik oddziaływania na fazę wodną cieku. W celu wykazania faktu odprowadzenia ścieków, bez względu na ich korzystny czy też niekorzystny wpływ na odbiornik, konieczne było przeprowadzenie badań własności osadów dennych zdeponowanych bezpośrednio powyżej i poniżej przekroju zrzutu ścieków. Zmiana niektórych własności osadu może być wykazana tylko za pomocą modelu matematycznego, opisującego przebiegi procesów zachodzących w próbce wody i próbce wody z osadami. Model matematyczny zawiera równania różniczkowe opisujące zmiany w czasie wskaźników jakości wody oraz koncentracji mikroorganizmów. Równania opisują przebiegi następujących procesów: biochemiczne utlenianie związków organicznych, nitryfikację pierwszego i drugiego stopnia, denitryfikację, amonifikację, defosfatację. W równaniach wzrostu mikroorganizmów uwzględniono asymilację azotu i fosforu. W opisie kinetyki wzrostu organizmów heterotroficznych uwzględniono także respirację endogenną oraz zamieranie komórek. Model matematyczny umożliwił określenie maksymalnych szybkości przemian zanieczyszczeń w próbkach wody i wody z osadami pobranych w przekrojach położonych powyżej i poniżej zrzutu ścieków. Na podstawie informacji o stężeniach wybranych substancji oraz szybkościach procesów biochemicznych w próbkach wody i wody z osadami wykazano istnienie w przeszłości zrzutu ścieków do potoku i jego wpływ na osady denne cieku. Próbki wody zawierające osady, pobrane powyżej i poniżej zrzutu ścieków zawierających osad czynny, miały różne własności. Dodanie osadów do próbki wody powoduje zmianę szybkości procesów biologicznych w porównaniu z tymi, jakie obserwowano w próbkach wody bez osadów. Próbka osadów pobranych w przekroju poniżej zrzutu ścieków, dodana do próbki wody, powoduje wystąpienie gwałtownego zużycia tlenu (procesy chemiczne i/lub biochemiczne) w ciągu pierwszych 6 godzin inkubacji próbki wody z osadem. Zużycie to jest większe od zużycia tlenu w próbce z osadem pobranym powyżej zrzutu ścieków. Warunki beztlenowe, jakie panowały w osadzie pobranym w przekroju poniżej zrzutu ścieków, przyczyniły się do wzrostu organizmów denitryfikujących. Dodanie tego osadu do próbki wody spowodowało wystąpienie procesu denitryfikacji.
The paper presents a method to assess the impact of untreated sewage containing activated sludge on the aquatic environment. Distant in time, incidental sewage discharges, particularly urban show the rapid disappearance of the impact on the aqueous phase of watercourse. In order to demonstrate the fact of sewage discharge, regardless of their beneficial or adverse effect on the receiver, it was necessary to study properties of the deposited sediments directly above and below the cross section of discharge. Amendment of certain properties of sediment can be demonstrated only by means of a mathematical model describing the phenomena in a water sample and in a water sample with the sediments. The mathematical model includes differential equations describing the changes in water quality indicators and concentration of microorganisms with time. The equations describe the following processes: the biochemical oxidation of organic compounds, nitrification of the first and second degree, denitrification, ammonification, defosfatation. The equations of the microbial growth include assimilation of nitrogen and phosphorus. Description of the kinetics of growth of heterotrophic organisms also includes endogenous respiration and decay of cells. The mathematical model allowed the determination of the maximum transformation rates of pollutants in water samples and water samples with sediments collected in sections located above and below the sewage discharge. On the basis of information on concentrations of selected substances and rates of biochemical processes in water samples and water samples with the sediments there has been demonstrated existence in the past the discharge of sewage into the stream and its impact on the stream bottom sediments. Water samples containing sediments above and below the improved discharge wastewater containing activated sludge had different properties. The addition of sediment to the water sample changed the speed of biological processes in comparison with those observed in water samples without the deposits. Sediment sample taken at the discharge section below, added to the samples of water, causes a rapid consumption of oxygen (chemical and/or biochemical processes) during the first 6 hours of incubation of water samples with the sediment. Consumption is greater than the oxygen consumption in a sample of sediment collected above the discharge. Anaerobic conditions that prevailed in the sediment collected in the section below the discharge of sewage contributed to the growth of denitrifying organisms. The addition of sediment to the water sample caused the occurrence of denitrification.
Źródło:
Inżynieria i Ochrona Środowiska; 2012, 15, 2; 119-142
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ tlenków azotu na jakość powietrza w pomieszczeniach
Impact of nitrogen oxides on the indoor air quality
Autorzy:
Bieniek, M.
Powiązania:
https://bibliotekanauki.pl/articles/340741.pdf
Data publikacji:
2008
Wydawca:
Główny Instytut Górnictwa
Tematy:
tlenki azotu
IAQ
jakość powietrza
zanieczyszczenia powietrza
nitrogen oxides
air quality
atmospheric pollutants emission
Opis:
Z uwagi na fakt, że przeważająca większość ludzi spędza około 70% czasu w pomieszczeniach (budynkach mieszkalnych, pomieszczeniach pracy i nauki, obiektach handlowych), konieczna jest ich ochrona przed bezpośrednim wpływem zmiennych zewnętrznych warunków klimatycznych, a także zapewnienie poczucia względnego komfortu przebywania, warunkowane stworzeniem właściwego mikroklimatu pomieszczenia IAQ (Indoor Air Quality). Dominujący wpływ na jakość powietrza wewnątrz budynków mają powstające w pomieszczeniach wentylowanych zanieczyszczenia. Ich źródłem są użytkownicy pomieszczeń oraz urządzenia stanowiące wyposażenie pomieszczeń, a także materiały budowlane użyte do wykończenia wnętrza (farby, lakiery, dywany, wykładziny syntetyczne). Odrębną grupę stanowią zanieczyszczenia wprowadzane do pomieszczeń wraz z powietrzem zewnętrznym, przy czym za zanieczyszczenie powietrza uważa się każdy jego składnik, który powoduje odstępstwa od klasycznego składu powietrza atmosferycznego. Do zanieczysz-czeń powietrza atmosferycznego zalicza się więc związki zawarte w spalinach, pyłki roślin, parę wodną, ale także jego naturalne składniki (O2, N2, CO2), jeżeli ich udział w powietrzu zewnętrznym jest różny od określonego dla klasycznego składu powietrza. Badania przeprowadzone przez amerykańską Agencję Ochrony Środowiska (???) wykazały, że w powietrzu wewnętrznym stężenia wielu zanieczyszczeń mogą być kilka razy większe niż w powietrzu zewnętrznym. Obowiązujące w Polsce przepisy prawne nie poruszają problemu jakości powietrza wewnątrz pomieszczeń, dotyczą jedynie wymaganej ilości powietrza wentylacyjnego i dopuszczalnych wartości stężeń substancji zanieczyszczających. Bardziej szczegółowo opracowano normy stężeń zanieczyszczeń na stanowiskach pracy, w których wyszczególniono dopuszczalne wartości normatywne dla 352 substancji chemicznych i 17 rodzajów pyłów, podczas gdy w przepisach dotyczących pomieszczeń przeznaczonych na stały pobyt ludzi wzięto pod uwagę jedynie 35 substancji zanieczyszczających. Ustawodawca pominął wiele zanieczyszczeń, co do których obecności i negatywnego wpływu na użytkowników pomieszczeń mieszkalnych nie ma wątpliwości, jak np. dwutlenek azotu. Postanowiono więc przybliżyć tę problematykę. Podjęto badania w celu określenia wpływu tlenków azotu na jakość powietrza w pomieszczeniach. Ich wyniki zostały omówione w niniejszym artykule.
Due to the fact, that predominantly most people spend ca. 70% of time indoors (dwelling buildings, rooms for work and learning, trade objects), their protection is necessary against direct changing of external climatic conditions. And also assuring of feeling of relative comfort of habitation conditioned by creation of proper indoor microclimate IAQ (Indoor Air Quality). Pollution arising in ventilated rooms has predominant impact on the indoor air quality. Its source are users of rooms as well as devices being equipment of rooms, and also building materials used to finish interior (paints, varnishes, carpets, synthetic facings). A separate group form the pollutants introduced to rooms together with an external air, and each component, which causes departures from classic composition of atmospheric air, is considered as a pollutant. Therefore, compounds contained in fumes, pollens of plants, water vapor are classified to be atmospheric air pollutants, but also its natural components (O2, N2, CO2), if their part in the external air differs from defined for classic composition of air. Researches conducted by U.S. Environmental Protection Agency (EPA) showed that concentrations of many pollutants in the indoor air could be few times higher than in the outdoor air. Legal regulations valid in Poland do not refer to the problem of indoor air quality, and concern required quantities of ventilating air and admissible values of polluting substances concentrations only. In more details there were developed standards of pollutants' concentrations at working posts, where admissible standardized values were specified for 352 chemical substances and 17 kinds of dusts. Whereas, only 35 polluting substances were taken into account in regulations related to rooms designed for permanent stay of people. Legislator skipped many contaminants, which presence and negative impact on users of habitable rooms is undoubted, e.g. nitrogen dioxide. Therefore, it was decided to study closer these problems and to conduct researches in this area. In this connection, researches were undertaken to define the nitrogen oxides' impact on the indoor air quality. Their results were discussed in the present article.
Źródło:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa; 2008, 2; 5-17
1643-7608
Pojawia się w:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmienność stężeń zanieczyszczeń zewnętrznych a jakość powietrza w pomieszczeniach budownictwa mieszkalnego
Variability of concentration of external pollutants and quality of air in the rooms of dwelling houses
Autorzy:
Bieniek, M.
Powiązania:
https://bibliotekanauki.pl/articles/340444.pdf
Data publikacji:
2005
Wydawca:
Główny Instytut Górnictwa
Tematy:
powietrze zewnętrzne
budownictwo mieszkalne
zanieczyszczenia
wentylacja
powietrze
jakość
outside air
dewelling houses
pollutants
ventilation
air
quality
Opis:
Inżynieria środowiska poświęca wiele uwagi jakości powietrza zewnętrznego. Ponieważ większość czasu człowiek spędza w pomieszczeniach, równie istotna jest jakość powietrza wewnętrznego. W przeważającej większości pomieszczeń budownictwa mieszkalnego wymiana powietrza realizowana jest za pomocą wentylacji naturalnej (grawitacyjnej). Intensywność wymiany powietrza jest wypadkową wielu jednocześnie oddziałujących parametrów mających charakter sił napędowych oraz zakłóceń. Jednym z nich są zanieczyszczenia powietrza wentylacyjnego. Zanieczyszczenia powstające wewnątrz pomieszczeń, ich źródła i charakter oddziaływania zostały w przeważającej większości dość dobrze opisane i rozeznane, natomiast dużym i ciągle niedocenianym problemem dla funkcjonowania wentylacji w pomieszczeniach budownictwa mieszkalnego są zanieczyszczenia powietrza zewnętrznego. Zakładanie, że w przypadku wentylacji naturalnej strumień powietrza wentylacyjnego dopływającego do pomieszczeń to powietrze "świeże" jest dużym uproszczeniem. Zbadanie wpływu tych nie branych dotąd pod uwagę zmiennych wartości oraz oszacowanie wielkości ich zmian może w znaczący sposób wpłynąć na stan naszej wiedzy o jakości powietrza wewnątrz pomieszczeń mieszkalnych i sposobach jej poprawy dla ochrony zdrowia użytkowników.
The quality of outside air is a great concern of environmental engineering. As the man passes most of his time in the rooms, of comparable importance is also the quality of internal atmosphere. In most rooms of dwelling houses, the exchange of air is realised by means of natural (gravitational) ventilation. The intensity of air exchange is a resultant of many simultaneously influencing parameters having a character of driving forces and disturbance. One of them are the pollutants of atmospheric air. The pollutants originating inside the rooms, their sources and character of influence have been, in most cases, fairly adequately described and recognised while a big and still underestimated problem for functioning of ventilation in the rooms of dwelling houses are the pollutants of the external atmosphere. The assumption that in the case of natural ventilation the stream of ventilation air flowing into the rooms is the stream of "fresh" air is a big simplifications. Investigating the influence of those, not considered so far, variables and evaluating the size of their changes can significantly influence the level of our knowledge about the quality of air inside the dwelling rooms, and about the methods of its improvement in favour of protection of health of inhabitants.
Źródło:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa; 2005, 4; 51-60
1643-7608
Pojawia się w:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie elementów uczenia maszynowego do modelowania stężenia zanieczyszczeń atmosferycznych: studium przypadku pyłu pm2.5 w Szczecinie
Application of machine learning in air pollutants modeling: a case study of pm2.5 in Szczecin (Poland)
Autorzy:
Bihałowicz, Jan Stefan
Powiązania:
https://bibliotekanauki.pl/articles/2175572.pdf
Data publikacji:
2022
Wydawca:
Szkoła Główna Służby Pożarniczej
Tematy:
modelowanie matematyczne
uczenie maszynowe
zanieczyszczenia atmosferyczne
PM2.5
pożar
mathematical modeling
machine learning
air pollutants
fire
Opis:
W pracy przedstawiono możliwość modelowania stężeń zanieczyszczeń w lokalizacji o określonym, stałym profilu emisji przy wykorzystaniu modeli uczenia maszynowego. Jako zanieczyszczenie wybrano pył PM2.5,a jako zmienne objaśniające przyjęto parametry metrologiczne mierzone na stacji synoptycznej. Przeprowadzono uczenie i walidację sześciu różnych modeli na podstawie obserwacji meteorologicznych zarejestrowanych w latach 2013–2018 na stacji IMGW-PIB w Szczecinie (Polska) oraz średniodobowych stężeń pyłu PM2.5 z tego samego okresu zmierzonych na stacji GIOŚ w Szczecinie przy ul. Andrzejewskiego, podzielonych na trzy równoliczne klasy stężeń. Dwa modele, które dawały najdokładniejsze wyniki, zostały szczegółowo przedstawione. Czułość tych modeli, w zależności od klasy stężenia pyłu, zawierała się pomiędzy 0,484 a 0,711. Te dwa modele zostały zastosowane do identyfikacji wzrostu średniodobowych stężeń w trakcie zdarzenia nietypowego – pożaru składowisk odpadów. Stężenia przewidziane w dniach, w których trwał pożar, były zaniżone względem faktycznych stężeń, co pozwala na zastosowanie modeli w identyfikacji zjawisk atypowych, które mają wpływ na stężenia zanieczyszczeń w danym miejscu.
The work presents the possibilities of using machine learning in modeling pollutant concentra tions at locations with defined constant sources of emission. The PM2.5 was chosen as the pollutant to be studied with meteorological variables as exogenous variables measured at a weather station. Six different models were implemented and cross-validated on meteorological data recorded in 2013-2018 at the Institute of Meteorology and Water Management station in Szczecin, Poland, and PM2.5 concentrations from the same period divided into three classes, measured at the air quality station of the Chief Inspectorate of Environmental Protection (Poland) located at Andrzejewskiego Street in Szczecin. Two best-performing models were described in detail. The sensitivity of the models was found to vary from 0.484 to 0.711 depending on the class of PM2.5 concentration. Those two models were then applied to identify increases in PM concentrations that were caused by an extraordinary incident – landfill fire. It was proven that the predicted values of concentration that occur during the fire were underestimated as compared to actual concentration levels and hence such models can be applied in the identification of abnormal phenomena that may affect the concentrations of pollutants in a given location.
Źródło:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej; 2022, 81; 7--28
0239-5223
Pojawia się w:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cosmetic wastewater treatment using dissolved air flotation
Oczyszczenie ścieków kosmetycznych z wykorzystaniem procesu flotacji ciśnieniowej
Autorzy:
Bogacki, J. P.
Marcinowski, P.
Naumczyk, J.
Wiliński, P.
Powiązania:
https://bibliotekanauki.pl/articles/205185.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wastewater treatment
GC-MS
gas chromatography
cosmetic wastewater
dissolved air flotation
PPCPs
pharmaceutical and personal care pollutants
oczyszczanie ścieków
chromatografia gazowa
ścieki kosmetyczne
flotacja ciśnieniowa
Opis:
Five cosmetics wastewater samples were treated by Dissolved Air Flotation (DAF) assisted by coagulation. Different aluminum based coagulants were used: (Al2(SO4)3, Al 1019, Al 3010, Al 3030, Al 3035, PAX 16 and PAX 19). The raw wastewater COD values were in the range 285–2124 mg/l. The efficiency of DAF depended on different coagulants and production profile of factory. COD removal was varied from 11.1 to 77.7%. The efficiency of coagulants was similar during treatment of particular sample. The best results were obtained with Al2(SO4)3 and for sample 5 – lotions and shampoos production. The wastewater from UV filter creams production (sample 4) was resistant to treatment by DAF regardless of used coagulant. HS-SPME-GC-MS analysis can be a confirmation of DAF effectiveness.
Pięć próbek ścieków kosmetycznych zostało poddanych oczyszczaniu z wykorzystaniem flotacji ciśnieniowej wspomaganej koagulacją. Stosowano różne koagulanty na bazie glinu: Al2(SO4)3, Al 1019, Al 3010, Al 3030, Al 3035, PAX 16 and PAX 19. Wartość ChZT ścieków surowych była w zakresie 285–2124 mg/l. Skuteczność procesu flotacji ciśnieniowej była zależna od zastosowanego koagulantu i profilu produkcji fabryki kosmetyków. Skuteczność usunięcia wartości ChZT była w przedziale 11,1–77,7%. Skuteczność wszystkich koagulantów podczas oczyszczania każdej z próbek ścieków była podobna. Najlepsze rezultaty uzyskano z wykorzystaniem koagulantu Al2(SO4)3 , dla próbki 5 – ścieki pochodzące z produkcji szamponów i logionów. Ścieki z produkcji kremów z filtrem UV (próbka 4) były oporne na oczyszczanie za pomocą procesu flotacji ciśnieniowej, niezależnie od zastosowanego koagulantu. Zastosowana analiza HS-SPME-GC-MS potwierdziła skuteczność oczyszczania z wykorzystaniem flotacji ciśnieniowej.
Źródło:
Archives of Environmental Protection; 2017, 43, 2; 65-73
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of effectiveness of advanced treatment of municipal wastewater by sorption and nanofiltration. Separate processes and integrated systems
Autorzy:
Bohdziewicz, J.
Kamińska, G.
Pawlyta, M.
Łukowiec, D.
Powiązania:
https://bibliotekanauki.pl/articles/208002.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
effluent treatment
carbon
effluents
nanofiltration
pollution
sorption
wastewater treatment
water filtration
inorganic pollutants
municipal effluents
municipal wastewaters
nitrogen
phosphorus
oczyszczanie ścieków
węgiel
ścieki
nanofiltracja
zanieczyszczenia
sorpcja
filtracja wody
zanieczyszczenia nieorganiczne
ścieki komunalne
azot
fosfor
Opis:
The feasibility of effluent treatment in separate processes and in integrated systems has been compared. In the sorption process, carbon nanotubes were used in a pressure installation, enabling execution of the process of sorption with nanofiltration in a cross-flow system. Evaluation of treatment effects based on the measurement of typical pollution parameters (COD, TOC, phenolic index, forms of nitrogen and phosphorus) and concentration of bisphenol A. The results show poor feasibility of sorption as a process for advanced treatment of municipal effluent. Effluent polishing in integrated sorption-nanofiltration systems, however, guaranteed high removal rates of organic and inorganic pollutants.
Źródło:
Environment Protection Engineering; 2015, 41, 2; 119-132
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies