Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Physico-chemical Parameters" wg kryterium: Temat


Tytuł:
Synthesis and Physico-chemical Studies of Base Catalyzed Methanolysis of Some Virgin Tropical Seed Oils
Autorzy:
Esonye, Chizoo
Onukwuli, Okechukwu Dominic
Ofoefule, Akuzuo Uwaoma
Powiązania:
https://bibliotekanauki.pl/articles/1113573.pdf
Data publikacji:
2017
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Extraction
Physico-chemical Parameters
Transesterification; Biodiesel
Vegetable oils
Opis:
The physico-chemical characterization of Prunus amygdalus, Dacryodes edulis and Chrysophillum albidium seed oils were investigated, together with their methyl esters. The vegetable oils were extracted by applying the solvent extraction method, using n-hexane. Prunus amygdalus had the highest oil yield (60.1%), followed by Dyacrodes edulis (55.76 %) and least from Chrysophillum albidium (13.67%). The oils and their biodiesel were then analyzed for acid value, free fatty acid, specific gravity, ash content, iodine value, peroxide value, saponification value, kinematic viscosity, flash point, smoke point, titre value, cloud point, moisture content and refractive index. Accordingly, Dyacrodes edulis seed oil had the highest acid value of 6.57 and required two-step transesterifictaion. The produced biodiesels were discussed in the light of ASTM D 9751, ASTMD 6751 and DIN 14214. These showed yields of 94.36%, 93.03% and 86.49%, cetane numbers of 70.40, 55.20 and 64.57 and calorific values of 31,178.39 KJ/kg, 34,421.50 KJ/kg and 32,838.38 KJ/kg for Prunus amygdalus, Dacryodes edulis and Chrysophyllum albidium, respectively. Other fuel-related properties showed highly improved qualities upon transesterification and compared well with ASTM and EU standards. The overall results showed that the seed oils are viable for biodiesel production.
Źródło:
World News of Natural Sciences; 2017, 15; 112-128
2543-5426
Pojawia się w:
World News of Natural Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of the Actual Status of the Cikapundung River Waters in the Densely-Inhabited Slum Area, Bandung City
Autorzy:
Rusdiyanto, Edi
Sitorus, Santun R. P.
Noorachmat, Bambang Pramudya
Sobandi, Ramalis
Powiązania:
https://bibliotekanauki.pl/articles/2028189.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
densely inhabited slum
microbiological parameters
physico-chemical parameters
water quality
Opis:
This research was intended to analyze the water quality of the Cikapundung River in Bandung City around the densely-inhabited slums and also to analyze the total number of bacteria coliform and Escherichia coli in the Cikapundung River, Bandung City. The research data was obtained by observing and performing a laboratory analysis through the assessment of environmental quality standard threshold based on the Government Regulation (PP) No. 82 of 2001. The results of laboratory analysis show that the actual condition of water quality of the Cikapundung River is overall classified as polluted, indicating 7 microbiological and physico-chemical parameters which have exceeded the quality standard such as: TSS, DO, BOD, COD, detergent/surfactant, total coliform, and Escherichia coli. In the upper part, there are 6 parameters below the quality standard, consisting of 4 physicochemical parameters and 2 microbiological parameters. In the middle part, there are 8 parameters below the quality standard consisting of 6 physico-chemical parameters and 2 microbiological parameters. In the lower part, there are 6 parameters that exceeded the quality standard consisting of 4 physico-chemical parameters and 2 microbiological parameters. The seasonal difference of parameters averagely has shown that the water quality in the rainy season is better than in the dry season. However, on average, the water sampling taken before flowing to the village has a better quality than past the village.
Źródło:
Journal of Ecological Engineering; 2021, 22, 11; 198-208
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of shallow groundwater suitability for irrigation purposes : A case study from Doornfontein area, South Africa
Autorzy:
Moges, Simeneh S.
Dinka, Megersa O.
Powiązania:
https://bibliotekanauki.pl/articles/28411663.pdf
Data publikacji:
2023
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
irrigation
Johannesburg
physico-chemical parameters
shallow groundwater
water quality
Opis:
The present study aims at evaluating the quality of shallow groundwater (SGW) and its suitability for irrigation purpose in the most urbanised part of Johannesburg city, South Africa. The SGW samples were collected in three consecutive years and analysed for 20 selected physicochemical parameters, and heavy metals. The results were compared with the South African water quality, and Food and Agricultural Organization irrigation water quality guidelines, and standard indices derived from laboratory outputs. The results of the study show that all physiochemical parameters and heavy metals were within the limits set by both guidelines for irrigation purposes, except for potassium (3.58 mg∙dm-3) and manganese levels (3.152 mg∙dm-3). The calculated irrigation parameter values of sodium adsorption ratio (SAR), sodium percentage (Na%), residual sodium carbonate (RSC), magnesium hazard (MH), Kelly’s ratio (KR) and permeability index (PI) were within the permissible range of irrigation water quality standards. The findings of this study provide helpful information for decision-makers such as utilisation of the studied groundwater for irrigation uses.
Źródło:
Journal of Water and Land Development; 2023, 58; 189--197
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the Impact of Ferronicel Industrial Activity on Drenica River Quality
Autorzy:
Abazi, Albona Shala
Gashi, Barie
Spahiu, Mimoza Hyseni
Bytyçi, Pajtim
Dreshaj, Adem
Powiązania:
https://bibliotekanauki.pl/articles/2173260.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
assessment
physico-chemical parameters
impact
industrial activity
Drenica river
Opis:
Today, environmental water degradation all over the world comes about due to the growth of urban, industrial and agricultural activities. As a result of these discharges without any prior treatment, the quality of river waters in Kosovo has deteriorated greatly. On the basis of the research that has been done so far in the rivers of Kosovo, it was shown that Drenica is one of the rivers that are constantly exposed to the discharge of industrial waters. Therefore, the purpose of this research was to analyze the impact of water discharged from Feronikeli on the water quality of the Drenica River and the possibility of its protection. The realization of this study is focused on the evaluation of physico-chemical parameters of the water of the Drenica River, the content of heavy metals in the water, the analysis and comparison of the results obtained using the standard for the assessment of the ecological status of surface waters of Romania (GD 161). Laboratory assays were developed according to standard analysis methods (APHA). The results obtained, analyzed and compared with the values of the parameters according to the standard referred to in this research, confirm that the water of the Drenica River belongs to the class of water with “good quality” only in the source area, while in other flow stations river, especially in the third station S3 (Ferronikel industrial zone), water has “poor quality”, passing into the category of “very poor quality”. Therefore, in order to improve the current situation, it is recommended to apply the best environmental practices and proper management of industrial waste.
Źródło:
Journal of Ecological Engineering; 2022, 23, 7; 312--322
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Physico-chemical parameter analysis of water in Musiri Taluk, Tamil Nadu, India
Autorzy:
Anbarasu, K.
Anbuselvan, G.
Powiązania:
https://bibliotekanauki.pl/articles/1119186.pdf
Data publikacji:
2017
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Musiri
Physico-chemical parameters
Total hardness
Turbidity
Water quality
Opis:
An analysis of the physico-chemical parameters of ground and surface water of Musiri Taluk (Tamil Nadu, India) were carried out to study the quality of water and suitability for domestic purpose. Cauvery water, well water and bore wells are the water resources of the study area. The parameters included pH, EC, TDS, Turbidity, Total hardness and content of Fluoride, Sulphate and Chloride were also assessed and compared with the standard values prescribed by BIS. The present investigation revealed that the quality of water of Cauvery water is suitable for drinking purposes, but the well water and bore well water samples are unfit for drinking and utility purpose.
Źródło:
World News of Natural Sciences; 2017, 6; 28-35
2543-5426
Pojawia się w:
World News of Natural Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Spatial Variability Analysis of Some Groundwater Physico-Chemical Parameters in Parts of Akwa-Ibom State, Nigeria
Autorzy:
Emujakporue, Godwin O.
Ngwueke, Marcel I.
Powiązania:
https://bibliotekanauki.pl/articles/1191777.pdf
Data publikacji:
2016
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Water analysis
Akwa Ibom
Physico-chemical parameters
Semi-variogram
Kriging
Opis:
The groundwater physico-chemical parameters of Parts of Akwa Ibom state and their spatial distribution have been examined in this study. The physico-chemical parameters analysed are Ph, total dissolved solids, electrical conductivity and water hardness. The average pH, electrical conductivity, water hardness and total dissolved solids obtained are 6.4, 163.4242 μS/cm, 83.81 mg/l and 90.5 mg/l respectively. The computed values are within the permissible limit set by World Health Organisation (WHO). Semi-variogram and ordinary kriging were used for the spatial distribution analysis. The semi variogram of the pH, total dissolved solids, electrical conductivity and water hardness were model with Gaussian, spherical, linear functions respectively. The pH map is dominated with values ranging from 6.2 to 6.6 while the total dissolved solids map is associated mainly with values ranging from 90 to 95 mg/l. The water hardness and electrical conductivity values increases from central part toward the west and eastern regions. The geostatical modelling has been used to estimate the values of the parameters at unsampled points.
Źródło:
World Scientific News; 2016, 50; 20-32
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
State Diagnosis of Macrozoobenthic Biodiversity in the Intertidal Zone of the Sandy Coast of Taghazout (Southwestern of Morocco)
Autorzy:
Haddad, Mohamed Ben
Lamine, Imane
Moukrim, Abdellatif
Bergayou, Hafida
Abou Oualid, Jaouad
Ait Alla, Aicha
Powiązania:
https://bibliotekanauki.pl/articles/1839588.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
Taghazout coasts
biodiversity
macro-zoobenthic structure
physico-chemical parameters
sediment
Opis:
The present work is a part of the impact study of the tourist resort "Taghazout Bay" installation on the coast of Taghazout (North of the Agadir bay). The purpose of this study was to assess the initial state of the macrozoobenthic structure present in the intertidal sands at the three study stations over the 2016 and 2017 seasons. The biological approach was accompanied by the study of some physico-chemical parameters of the seawater (temperature, pH, salinity and dissolved oxygen) and the study of the sediment (grading structure, classification, and contents in organic matter). PCA analysis identified a perfect correlation between the physico-chemical parameters. The sediment contains three grading classes only (medium sand, fine sand, and very fine sand), very well classified with normal proportions of organic matter. The study of intertidal benthic macrofauna of the sandy substrate shows ten species and spatiotemporal variations with a clear dominance of the Donax trunculus bivalve species. The authors noticed – from the DIMO model – that the variation profile of the spring and summer (2016 and 2017) shows a community dynamics called "Diversity type". In winter and in autumn, they are known as the "Evenness type". The rank-frequency diagram explains that the benthic community of Taghazout sandy coast exists in the stage "Pioneer 1". The ascending hierarchical clustering gave three logical gatherings of seasons. The faunistic structure of this benthic community revealed the M>C>P shape. The authors also noticed that there is diversity in regimes in this ecosystem.
Źródło:
Journal of Ecological Engineering; 2021, 22, 4; 126-137
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elucidation of tidal spatial-temporal variation of physico-chemical and nutrient parameters of estuarine water at South Gujarat
Autorzy:
Desai, Nisheeth C.
Kukadiya, Nipul B.
Mehta1, Jignasu P.
Godhani, Dinesh R.
Lakhmapurkar, Jayendra
Dave, Bharti P.
Powiązania:
https://bibliotekanauki.pl/articles/1030123.pdf
Data publikacji:
2020
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Estuary water
Nutrients
Physico-chemical parameters
Principal component analysis
Tidal variation
Opis:
In the present study, the four estuaries were selected from the South Gujarat region to appraise the impact of industrial pollution in the estuarine water samples. The study focused on the tidal variation of nutrients, which disclosed that concentrations of NO2–N, NO3–N, NH4–N, TN, and reactive silicates were higher in low-tide whereas pH, salinity, and dissolved oxygen were higher in high-tide water samples. The results of high BOD and low DO expose the anthropogenic inputs in these estuaries during the low-tide. The results of physico-chemical and nutrients parameters of water showed that the pollution level is strongly influenced by tidal and seasonal changes. Pearson’s correlation matrix and principal component analysis (PCA) are applied to a hydrological and hydrographical dataset for finding the spatial-temporal variation during the tidal difference. This study suggested that there is an impact of industrial pollution and anthropogenic inputs on the estuarine water of the study area.
Źródło:
World Scientific News; 2020, 143; 79-102
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Jakość wód cieku Bogdanka
Quality water in Bogdanka stream
Autorzy:
Janicka, E.
Kanclerz, J.
Borowiak, K.
Wiatrowska, K.
Lisiak, M.
Powiązania:
https://bibliotekanauki.pl/articles/400495.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
ciek
zbiorniki
jakość wody
parametry fizykochemiczne
watercourse
reservoirs
water quality
physico-chemical parameters
Opis:
W pracy przedstawiono wyniki badań jakości wody cieku Bogdanka oraz zbiorników przez które przepływa, w okresach wegetacyjnych lat 2011–2012. Próbki do analiz laboratoryjnych pobierane były w siedmiu punktach pomiarowo-kontrolnych i obejmowały oznaczenie wybranych elementów fizykochemicznych tj. O2, BZT5, ChZT, pH, przewodność w 20° C, N-NO3, N-NH4 i PO43-. Analiza otrzymanych wyników wykazała, że jakość wody w górnym biegu Bogdanki była lepsza niż w jej dolnym biegu – poniżej jeziora Rusałka oraz Stawu Sołackiego. Wielkość stężeń niektórych badanych wskaźników fizykochemicznych (ChZT, BZT5 i PO43-) przekraczały wartości graniczne klasy II i dlatego stan cieku określono jako poniżej dobrego.
The paper concerns with water quality of Bogdanka Stream and its reservoirs, which flow trough it, during vegetation period of 2011–2012. The water samples for physico-chemical analysis were collected from seven control points and analyzed for: O2, BOD5, COD, pH, EC, N-NO3, N-NH4 and PO43-. Results obtained showed that water quality in the upper-course of Bogdanka was better than in the lower-course – bellow Rusałka and Staw Sołacki Lakes. Some parameters such as: COD, BOD5 and PO43- exceeded threshold values for second class and classified water as below good.
Źródło:
Inżynieria Ekologiczna; 2017, 18, 1; 202-208
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of soil properties of a lentic ecosystem in semiarid region: Nakki Lake, Mount Abu, India
Autorzy:
Gothwal, Rakesh
Jangir, O. P.
Powiązania:
https://bibliotekanauki.pl/articles/1031871.pdf
Data publikacji:
2020
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Lentic ecosystem
Mount Abu
Nakki Lake
alkaline
physico-chemical parameters
phytoplanktons
semiarid region
zooplanktons
Opis:
Soil parameter balances the ecological symmetry in a lake-ecosystem. It determines the portability of water through its inter-relationship among phytoplanktons and zooplanktons. The purpose of the study is to identify the status of soil parameters in different seasons across the surrounding area of Nakki Lake, Mount Abu (2017-19). The soil parameters were analyzed and based on the results of the physico-chemical parameters of the soil; it confirms that the soil in the surrounding area of Nakki Lake in winter season can be classified as moderately alkaline soil. The soil analysis shows a linear positive correlation found with undeviating pattern (r = 1.000) of Clay with Bulk density and nitrogen; chloride with sulphur. Permeability is showing strong negative correlation with most of the soil parameters and shows linear trend in negative correlation (r = -1.000) with potassium.
Źródło:
World Scientific News; 2020, 149; 81-91
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wastewater reuse and mapping of irrigable soils: Case of Sidi Bel Abbes City, Algeria
Autorzy:
Mahfoud, Zakaria
Khaldi, Abdelkader
Korichi, Khaled
Powiązania:
https://bibliotekanauki.pl/articles/293066.pdf
Data publikacji:
2020
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
bacteriology
physico-chemical parameters
reuse
soil
Sidi Bel Abbes City
wastewater
wastewater treatment plant (WWTP)
Opis:
This work aims to evaluate the treated wastewater from the activated sludge treatment plant in the City of Sidi Bel Abbes (North-Western Algeria) which is required for reuse in irrigation. The control of irrigated areas downstream is done based on a pedological study. Physico-chemical analysis such as (pH, BOD5, COD and SS) indicate results in Algerian and international standards required by the WHO. The Sodium Adsorption Ratio and Electrical Conductivity values of the treated wastewater belong to the C3-S1 class. The treated wastewater has a fairly good microbiological quality that meets Algerian standards. The helminth eggs are practically absent. The concentrations of heavy metals are much lower than the limits prescribed in the Algerian decrees. Therefore, the overall processing plant efficiency is satisfactory and has the characteristics of a good treated water quality for reuse in the field of irrigation while protecting the environment. The pedological study of the soil samples shows that the most dominant fraction is undeveloped calcimagnetic. The planned irrigation plain covers an area of about two thousand hectares. Depending on the crops to irrigate; the development and nature of the necessary or recommended improvements, the proposed irrigation perimeter could be classified into five categories in which only three categories are irrigable. Water projects have been proposed to ensure the irrigation of three subdivided sectors.
Źródło:
Journal of Water and Land Development; 2020, 46; 153-161
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena jakości wód powierzchniowych na terenie Łodzi
Surface water quality assessment in Lodz
Autorzy:
Krężel, S.
Wira, K.
Olejnik, D.
Powiązania:
https://bibliotekanauki.pl/articles/412665.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Przemysłu Skórzanego
Tematy:
woda
wody powierzchniowe
klasy jakości
parametry fizyko-chemiczne
water
surface water
quality classes
physico-chemical parameters
Opis:
Wody powierzchniowe są czynnikiem krajobrazowym, rekreacyjnym, a także środowiskiem bytowania organizmów żywych i dlatego niezwykle ważne jest przeprowadzanie badań w celu określenia ich jakości i oceny wpływu oddziaływania na środowisko oraz życie człowieka. Na terenie Łodzi znajduje się wiele zbiorników pochodzenia naturalnego, jak i antropogenicznego o różnorodnym przeznaczeniu - od krajobrazowego, poprzez wędkarskie, aż po kąpieliskowe. Wody na terenie Łodzi charakteryzują się dużą zmiennością składu fizyko-chemicznego, jednakże pod względem jakości, najlepsze umiejscowione są w północnej i wschodniej części Łodzi.
Surface waters are a landscaping and recreational factor, as well as an environment of living organisms, and therefore it is extremely important to carry out research in order to determine their quality and assess the impact on the environment and human life. There are many natural and anthropogenic reservoirs in Lodz for various purposes-from the landscape, through fishing, bathing. Water in Lodz are characterized by high variability of chemical and physical composition, however, in terms of the quality of the best are located in the northern and eastern parts of the city.
Źródło:
Technologia i Jakość Wyrobów; 2018, 63; 85-94
2299-7989
Pojawia się w:
Technologia i Jakość Wyrobów
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmiany wybranych parametrów paliw w procesach utleniania
Changes of selected fuel parameters in oxidation processes
Autorzy:
Bukrejewski, P.
Skolniak, M.
Wardzińska, D.
Powiązania:
https://bibliotekanauki.pl/articles/142899.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Przemysłu Chemicznego. Zakład Wydawniczy CHEMPRESS-SITPChem
Tematy:
utlenianie
benzyna
olej napędowy
parametry fizykochemiczne paliw
oxidation
gasoline
diesel fuel
physico-chemical parameters of fuels
Opis:
W artykule przedstawiono wyniki badań mających na celu określenie zmian wybranych parametrów fizykochemicznych paliw zachodzących w procesach ich utleniania. W badaniach własnych wykorzystano handlowe oleje napędowe i benzyny, które poddano procesom przyśpieszonego utleniania. Analizowano zmiany takich parametrów, jak: gęstość, współczynnik załamania światła, stabilność oksydacyjna, okres indukcyjny, zawartość żywic i tendencja do blokowania filtra (FBT).
The article presents results of research aimed at identifying changes in selected physico-chemical parameters of fuels occurring in the process of their oxidation. In own research, commercial diesel fuels and gasolines, which undergone accelerated oxidation processes, were used. The changes of parameters such as density, refractive index, oxidation stability, induction period, the content of gum, and filter blocking tendency (FBT) were analysed.
Źródło:
Chemik; 2015, 69, 11; 759-770
0009-2886
Pojawia się w:
Chemik
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie wybranych parametrów fizyczno-chemicznych wód ze studni głębinowych z terenu Łodzi
Study of selected physical and chemical parameters of waters from deep wells in Lodz area
Autorzy:
Olejnik, D.
Czubakowska, P.
Powiązania:
https://bibliotekanauki.pl/articles/412764.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Przemysłu Skórzanego
Tematy:
woda
wody podziemne
parametry fizyko-chemiczne
jakość wody
water
ground water
physico-chemical parameters
water quality
Opis:
Wody ze studni głębinowych cieszą się zwykle dużym zainteresowaniem okolicznych mieszkańców, pobierają oni wodę z tych ujęć przede wszystkim w celach konsumpcyjnych, twierdząc, że jest ona smaczniejsza i zdrowsza od dostępnej w kranach. Niestety wody podziemne mogą zawierać substancje mineralne i organiczne w stężeniach przekraczających wartości dopuszczalne dla wód do picia i na potrzeby gospodarcze. Przeprowadzone badania wykazały, że pobieranie wody z ujęć głębinowych przez mieszkańców Łodzi na cele konsumpcyjne jest uzasadnione. Należy pamiętać jednak o tym, że woda ze studni głębinowych nadaje się tylko do spożycia bezpośredniego gdyż w wyniku długotrwałego przechowywania istnieje ryzyko rozwoju organizmów mogących szkodzić zdrowiu.
Water from deep wells is usually very attractive to local residents, and they collect water from these sources primarily for consumption purposes, claiming that it is tastier and healthier than available in taps. Unfortunately, ground water may contain mineral and organic substances in concentrations exceeding the limit values for drinking water and household use. The conducted research has shown that the collection of water from deep wells for consuming purposes is justified. However, it is important to remember that water from wells is only suitable for direct consumption since long-term storage can produce health hazards.
Źródło:
Technologia i Jakość Wyrobów; 2017, 62; 161-169
2299-7989
Pojawia się w:
Technologia i Jakość Wyrobów
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena jakości olejów napędowych wykorzystywanych do zasilania silników o ZS z wybranych olsztyńskich stacji paliw
Evaluation of the quality of diesel fuels used for powering diesel engines received from Olsztyn selected petrol stations
Autorzy:
Ambrosewicz-Walacik, M.
Piętak, A.
Powiązania:
https://bibliotekanauki.pl/articles/133743.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Naukowe Silników Spalinowych
Tematy:
olsztyński rynek paliw
oleje napędowe
parametry fizykochemiczne
petrol stations from Olsztyn
diesel fuels
physico-chemical parameters
Opis:
Celem pracy była ocena parametrów fizyko-chemicznych 10 próbek olejów napędowych zakupionych na olsztyńskich stacjach paliw. Próbki scharakteryzowano pod względem zawartości wody, lepkości kinematycznej w temp. 40°C, gęstości w temp. 15°C, liczby kwasowej, zawartości siarki, temperatury zapłonu i zablokowania zimnego filtra, stabilności oksydacyjnej w temp. 110°C oraz zawartości zanieczyszczeń stałych. Na podstawie przeprowadzonych analiz wykazano, że zakupione paliwa nie spełniły wymogu stabilności oksydacyjnej, której dopuszczalna wartość jest określona na poziomie powyżej 20 h. Pozostałe badane wyróżniki jakościowe były zgodne z wymaganiami norm.
The aim of the study was to evaluate physico-chemical parameters of 10 samples of diesel fuel purchased from Olsztyn stations. The samples were characterized for water content, kinematic viscosity at 40°C, density at 15°C, acid number, sulfur content, flash point and cold filter plugging point, oxidative stability at 110°C and solids content. Based on the analyzes it was shown that the fuel purchased did not meet the requirement oxidation stability, which limit value is set at a level above 20 hours. Other tested discriminants of quality were consistent with the requirements of the standards.
Źródło:
Combustion Engines; 2015, 54, 3; 963-967
2300-9896
2658-1442
Pojawia się w:
Combustion Engines
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies